Estimation of maximum ventricular elastance under assistance with a rotary blood pump.

Abstract:

:The maximum ventricular elastance is a reliable index for assessing the cardiac function from changes in its pressure-volume relationship. The advantage of this index is that it can represent the contractility of either unassisted hearts or native hearts assisted with rotary blood pumps. However, there are situations in which changes in the ventricular load required for the conventional estimation method might be risky. For example, in a bridge-to-recovery the cardiac function should also be continuously observed after the implantation of a rotary blood pump. In this article, we present the results of the estimation of the maximum elastance with in vivo data using the parameter optimization method, which is a single-beat estimation method. The estimated values for the normal cardiac function (6.8 +/- 0.6, 4.5 +/- 0.9, 4.2 +/- 1.8 mm Hg/mL) were significantly different from those for the low cardiac function (3.2 +/- 1.5, 1.9 +/- 1.0, 1.9 +/- 1.2 mm Hg/mL) from the data of the three animals that were analyzed. Besides, the maximum elastance values were independent of the pump rotational speed. These results indicate that this index might be useful for the detection of the myocardial recovery.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Sugai TK,Tanaka A,Yoshizawa M,Shiraishi Y,Yambe T,Nitta S,Baba A

doi

10.1111/j.1525-1594.2009.00876.x

subject

Has Abstract

pub_date

2010-05-01 00:00:00

pages

442-6

issue

5

eissn

0160-564X

issn

1525-1594

pii

AOR876

journal_volume

34

pub_type

杂志文章
  • Evaluation of membrane oxygenators and reservoirs in terms of capturing gaseous microemboli and pressure drops.

    abstract::An increasing amount of evidence points to cerebral embolization during cardiopulmonary bypass (CPB) as the principal etiologic factor of neurologic complications. In this study, the capability of capturing and classification of gaseous emboli and pressure drop of three different membrane oxygenators (Sorin Apex, Teru...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00955.x

    authors: Guan Y,Palanzo D,Kunselman A,Undar A

    更新日期:2009-11-01 00:00:00

  • Treatment of thyrotoxic crisis with plasmapheresis and single pass albumin dialysis: a case report.

    abstract::Thyrotoxic crisis (thyroid storm) is a life-threatening condition. Standard therapy is based on thiamazole, prednisolone, and nonselective beta-blockers. Extracorporeal plasmapheresis is an additional tool for removing circulating thyroxine in patients who do not respond quickly to conventional standard therapy. As th...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00924.x

    authors: Koball S,Hickstein H,Gloger M,Hinz M,Henschel J,Stange J,Mitzner S

    更新日期:2010-02-01 00:00:00

  • Atrial versus ventricular cannulation for a rotary ventricular assist device.

    abstract::The ventricular assist device inflow cannulation site is the primary interface between the device and the patient. Connecting these cannulae to either atria or ventricles induces major changes in flow dynamics; however, there are little data available on precise quantification of these changes. The objective of this i...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2010.01093.x

    authors: Timms D,Gregory S,Hsu PL,Thomson B,Pearcy M,McNeil K,Fraser J,Steinseifer U

    更新日期:2010-09-01 00:00:00

  • Nonsymmetric leaflet motion of St. Jude Medical mitral valves simulated with a computer-controlled hydraulic mock circulator.

    abstract::Since the introduction of high-performance prosthetic heart valves, particularly bileaflet valves and monoleaflet valves with larger opening angles, we have observed in vivo complex leaflet motion which has not been experimentally confirmed yet. We developed a computer-controlled hydraulic mock circulator to study the...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb00373.x

    authors: Ohta Y,Okamoto K,Sonderegger M,Dohi T,Matsumoto H,Horiuchi T

    更新日期:1997-04-01 00:00:00

  • Binding of antithrombin to immobilized heparin under varying flow conditions.

    abstract::Rheologic factors are likely to influence the balance between thrombotic and antithrombotic forces at the level of the vascular wall. In this study, the effects of flow-velocity/wall shear stress on the interaction of antithrombin (AT) with surface-immobilized heparin were investigated. The binding of AT to low-affini...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors: Pasche B,Elgue G,Olsson P,Riesenfeld J,Rasmuson A

    更新日期:1991-12-01 00:00:00

  • Reduction of early postoperative morbidity in cardiac surgery patients treated with continuous veno-venous hemofiltration during cardiopulmonary bypass.

    abstract::Cardiac surgery with cardiopulmonary bypass is associated with a systemic inflammatory response syndrome. The major clinical features of this include a reduction of pulmonary compliance and increased extracellular fluids, with increased pulmonary shunt fraction similar to acute respiratory distress syndrome, thus resu...

    journal_title:Artificial organs

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/j.1525-1594.2009.00777.x

    authors: Luciani R,Goracci M,Simon C,Principe F,Fazzari L,Punzo G,Menè P

    更新日期:2009-08-01 00:00:00

  • Totally Endoscopic Robotic-Assisted Cardiac Surgery in Children.

    abstract::Robotic surgery for intracardiac pathologies in children is relatively uncommon. This study presents our initial experience with robotic-assisted cardiac surgery in children. We also present the feasibility and safety of robotic surgery in children. From May 2013 to June 2018, 30 children underwent totally endoscopic ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13357

    authors: Onan B,Aydin U,Kadirogullari E,Onan IS,Sen O

    更新日期:2019-04-01 00:00:00

  • Pulsatile in vitro simulation of the pediatric univentricular circulation for evaluation of cardiopulmonary assist scenarios.

    abstract::The characteristic depressed hemodynamic state and gradually declining circulatory function in Fontan patients necessitates alternative postoperative management strategies incorporating a system level approach. In this study, the single-ventricle Fontan circulation is modeled by constructing a practical in vitro bench...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00951.x

    authors: Dur O,Lara M,Arnold D,Vandenberghe S,Keller BB,DeGroff C,Pekkan K

    更新日期:2009-11-01 00:00:00

  • New versatile dual-support pediatric heart pump.

    abstract::Mechanical circulatory support (MCS) devices for pediatric patients continue to lag in development behind those for adults. There is no heart pump with the design innovation to support dysfunctional states of heart failure and the anatomic heterogeneity of cardiac defects in pediatric patients. To address this unmet n...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13507

    authors: Fox C,Sarkisyan H,Stevens R,Arabia F,Fischer W,Rossano J,Throckmorton A

    更新日期:2019-11-01 00:00:00

  • Circulatory support for patients experiencing postcardiotomy cardiogenic shock: analysis of risk factors for death and long-term follow-up.

    abstract::Over the last 5 years, 12 patients received ventricular assist devices (VADs) while in postcardiotomy cardiogenic shock. There were 7 male and 5 female patients ranging in age from 22 to 73 years (average age, 54). Eight patients underwent surgery for valve replacements, 3 for coronary artery bypass graftings, and 1 f...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1993.tb00608.x

    authors: Murakami T,Nakayama H,Irie H,Kino K,Hisamochi K,Koomoto T,Takagaki M,Sugawara E,Senoo Y,Teramoto S

    更新日期:1993-07-01 00:00:00

  • Artificial liver: present and future.

    abstract::Early in 1956, the first model of a biological artificial liver, using a live dog's liver incorporated in a cross-hemodialyzer, was placed in an experimental animal with portocaval encephalopathy. This "biological artificial liver," a hybrid artificial liver in the present terminology, was the first in the world. In O...

    journal_title:Artificial organs

    pub_type: 历史文章,杂志文章

    doi:10.1111/j.1525-1594.1986.tb02548.x

    authors: Hori M

    更新日期:1986-06-01 00:00:00

  • In Vitro Evaluation of Pediatric Hollow-Fiber Membrane Oxygenators on Hemodynamic Performance and Gaseous Microemboli Handling: An International Multicenter/Multidisciplinary Approach.

    abstract::The objective of this study was to compare the hemodynamic performances and gaseous microemboli (GME) handling ability of two pediatric oxygenators in a simulated pediatric cardiopulmonary bypass (CPB) model and the importance of adding an arterial filter in the circuit. The circuit consisted of a Braile Infant oxygen...

    journal_title:Artificial organs

    pub_type: 杂志文章,多中心研究

    doi:10.1111/aor.12912

    authors: Wang S,Caneo LF,Jatene MB,Jatene FB,Cestari IA,Kunselman AR,Ündar A

    更新日期:2017-09-01 00:00:00

  • Anionic collagen: polymer composites with improved dielectric and rheological properties.

    abstract::This work describes the preparation and characterization of anionic collagen composites with rhamsan and vinylidene fluoride-trifluorethylene with improved rheological and dielectric properties without loss of collagen secondary structure with an interaction occurring between both macromolecules of the composites. On ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.06109.x

    authors: Goissis G,Piccirili L,Goes JC,de Guzzi Plepis AM,Das-Gupta DK

    更新日期:1998-03-01 00:00:00

  • Pseudoendothelium formation in expanded polytetrafluoroethylene grafts implanted in the inferior vena cava of normal and defibrinogenated dogs.

    abstract::The outgrowth of endothelial cells in an expanded polytetrafluoroethylene graft implanted in the canine inferior vena cava was studied by scanning electron microscopy. The adjacent endothelial cells of the vena cava started to invade the anastomotic area three days after the implantation and reached approximately the ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1981.tb04020.x

    authors: Ishimaru S,Berglin E,Hansson HA,Teger-Nilsson AC,William-Olsson G

    更新日期:1981-11-01 00:00:00

  • Quantification of the secondary flow in a radial coupled centrifugal blood pump based on particle tracking velocimetry.

    abstract::Secondary flow in the centrifugal blood pump helps to enhance the washout effect and to minimize thrombus formation. On the other hand, it has an adverse effect on pump efficiency. Excessive secondary flow may induce hemolytic effects. Understanding the secondary flow is thus important to the design of a compact, effi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2004.29012.x

    authors: Watanabe N,Masuda T,Iida T,Kataoka H,Fujimoto T,Takatani S

    更新日期:2005-01-01 00:00:00

  • A new technique to increase coronary flow. Preliminary report.

    abstract::This study was planned to investigate whether part of the energy produced by cardiac contraction to propel blood toward the systemic circulation can be used to increase the coronary flow in systole. Ten devices (I-X) designed to divert laterally part of a flow column (without substantially increasing resistance to flo...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1979.tb01080.x

    authors: Moulopoulos S,Stamatelopoulos S,Boufas D,Yannopoulos C,Marousis G,Kouvaras G

    更新日期:1979-11-01 00:00:00

  • Cooling device for bradycardia based on Peltier element for accurate anastomosis of off-pump coronary artery bypass grafting.

    abstract::Upon introducing off-pump coronary artery bypass grafting (CABG), the indications for CABG were expanded to include patients who previously had no operative indications. For accurate anastomosis, various devices and methods have been developed. Bradycardia is easily induced by drug administration. However, this method...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2002.07087.x

    authors: Kuniyoshi Y,Koja K,Miyagi K,Shimoji M,Uezu T,Arakaki K,Yamashiro S,Mabuni K,Senaha S

    更新日期:2002-10-01 00:00:00

  • Cytotoxicity of two novel formulations of calcium phosphate cements: a comparative in vitro study.

    abstract::The purpose was to evaluate the cytotoxicity of two novel formulations (alpha and beta) of calcium phosphate cements. Positive control, represented by a commercial hydroxyapatite cement, and negative control were included for comparative purposes. A continuous lineage of fibroblastic cells was used, and the effect of ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2005.29022.x

    authors: Rossa C Jr,Marcantonio E Jr,Santos LA,Boschi AO,Raddi MS

    更新日期:2005-02-01 00:00:00

  • Effect of electrolyzed water on wound healing.

    abstract::Electrolyzed water accelerated the healing of full-thickness cutaneous wounds in rats, but only anode chamber water (acid pH or neutralized) was effective. Hypochlorous acid (HOCl), also produced by electrolysis, was ineffective, suggesting that these types of electrolyzed water enhance wound healing by a mechanism un...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06557-3.x

    authors: Yahagi N,Kono M,Kitahara M,Ohmura A,Sumita O,Hashimoto T,Hori K,Ning-Juan C,Woodson P,Kubota S,Murakami A,Takamoto S

    更新日期:2000-12-01 00:00:00

  • The status of pacemaker implantations in Japan.

    abstract::It has been over 40 years since the initial clinical application of a cardiac pacemaker. Currently, approximately 300 per million patients in the United States and Europe are kept alive owing to the benefit of implantable pacemakers. Recently, the Japanese Cardiac Pacing Society and the Japanese Society of Artificial ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1994.tb03303.x

    authors: Kojima R

    更新日期:1994-01-01 00:00:00

  • Thrombogenicity of deflated intraaortic balloon: impact of heparin coating.

    abstract::In a calf model, 3 standard and 3 heparin coated intraaortic balloons (IAB) were inserted and left deflated in the descending aorta during 20 min to simulate balloon rupture. At the end of the experiment, the IAB were examined, and 3 samples of each were collected for scanning electron microscopy (SEM) analysis. None ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06228.x

    authors: Mueller XM,Tevaearai HT,Hayoz D,von Segesser LK

    更新日期:1999-02-01 00:00:00

  • Behavior of endothelial cells cultured on Silastic and Dacron velour under flow conditions in vitro: implications for prelining vascular grafts with cells.

    abstract::Tissue-cultured bovine aortic endothelial cells were subjected to flow in an in vitro circulatory loop designed to simulate the flow and pressure conditions in the aorta. The cells were cultured under stationary conditions on tubes of fibronectin-coated Silastic or of Dacron velour. The tubes were then added to the fl...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1983.tb04156.x

    authors: Eskin SG,Navarro LT,O'Bannon W,DeBakey ME

    更新日期:1983-02-01 00:00:00

  • Influence of Instruments Used in Root Canal Preparation on Amount of Apically Extruded Debris.

    abstract::The aim of the present study was to compare the effects of ProTaper Gold, WaveOne Gold, ProTaper Universal, and WaveOne instruments on the amount of apically extruded debris. Eighty mandibular premolar teeth with straight root canals were selected and assigned to four groups (n = 20). The root canals were instrumented...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12675

    authors: Karataş E,Ersoy İ,Gündüz HA,Uygun AD,Kol E,Çakıcı F

    更新日期:2016-08-01 00:00:00

  • A novel in vitro assessment of tissue valve calcification by a continuous flow type method.

    abstract::A dynamic flow type testing to study calcification was self-designed to investigate calcification in bioprosthetic heart valves. The apparatus consists of a container into which leaflets from a porcine aortic valve are placed, a chamber that contains calcium solution, and a peristaltic pump that provides a continuous ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06482-2.x

    authors: Park JC,Hwang YS,Han DW,Suh H

    更新日期:2000-02-01 00:00:00

  • Development of an intravascular pumping oxygenator using a new silicone membrane.

    abstract::A new intravascular pumping oxygenator (IVPO) was developed for intravascular gas exchange and circulatory assistance in critically ill patients with respiratory and circulatory failure. The IVPO utilizes new silicone hollow fibers (diameter, 1 mm; membrane width, 50 microns) and consists of two driving tubes for the ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb00703.x

    authors: Sueda T,Fukunaga S,Morita S,Sueshiro M,Hirai S,Okada K,Orihashi K,Matsuura Y

    更新日期:1997-01-01 00:00:00

  • Effects of atrial arrhytmias on the regurgitation of a monoleaflet prosthetic heart valve.

    abstract::Many patients who receive a prosthetic heart valve also have or acquire cardiac arrhythmias. However, most in vitro studies of prosthetic valves examine them under normal rhythms. In this study, a monoleaflet prosthetic heart valve was tested in vitro under conditions that simulated normal sinus rhythm, first degree a...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2005.29101.x

    authors: Zapanta CM

    更新日期:2005-08-01 00:00:00

  • Pulse push/pull hemodialysis: in vitro study on new dialysis modality with higher convective efficiency.

    abstract::Midsize molecule retention is related with renal-failure-associated mortality. Here, the authors describe a new dialysis modality, pulse push/pull hemodialysis (PPPHD), which increases convective clearance. Blood and dialysate are circulated by a pulsatile pump, but with pulsatile flow patterns that are 180 degrees ou...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00561.x

    authors: Lee K,Lee SR,Mun CH,Min BG

    更新日期:2008-05-01 00:00:00

  • Initial experience with Impella RP in a quaternary transplant center.

    abstract::Right ventricular failure is one of the most common complications encountered after left ventricular assist device implantation and heart transplantation. It has been reported to have an incidence up to 30%. It increases morbidity and short-term mortality. Impella RP is a small pump that can provide up to 4L/min of fl...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13610

    authors: Monteagudo-Vela M,Simon A,Panoulas V

    更新日期:2020-05-01 00:00:00

  • Prediction of mechanical hemolysis in medical devices via a Lagrangian strain-based multiscale model.

    abstract::This work introduces a new Lagrangian strain-based model to predict the shear-induced hemolysis in biomedical devices. Current computational models for device-induced hemolysis usually utilize empirical fitting of the released free hemoglobin (Hb) in plasma from damaged red blood cells (RBCs). These empirical correlat...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13663

    authors: Nikfar M,Razizadeh M,Zhang J,Paul R,Wu ZJ,Liu Y

    更新日期:2020-08-01 00:00:00

  • Computational fluid dynamics and stent design.

    abstract::Stents are small, usually metallic tubes that are intended to prop open arteries blocked with atherosclerotic plaques. While stents have been used successfully in recent years, they still suffer from failure due to development of new tissue in stented segment (restenosis). Variations in the failure rates associated wi...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1046/j.1525-1594.2002.07084.x

    authors: Frank AO,Walsh PW,Moore JE Jr

    更新日期:2002-07-01 00:00:00