Abstract:
:Stents are small, usually metallic tubes that are intended to prop open arteries blocked with atherosclerotic plaques. While stents have been used successfully in recent years, they still suffer from failure due to development of new tissue in stented segment (restenosis). Variations in the failure rates associated with different stent designs have led researchers to investigate the role of near-wall flow patterns. While there is no direct evidence yet, the patterns of flow stagnation as the blood flows past the stent struts may affect the restenosis process. Computational fluid dynamics (CFD) approaches are well suited for obtaining detailed information on stent flow patterns. Many CFD simulations make use of a two-dimensional model. The strong dependence of flow stagnation on stent strut spacing has been clearly demonstrated. These results have been employed to interpret the results of in vitro experiments designed to elucidate the mechanisms of restenosis.
journal_name
Artif Organsjournal_title
Artificial organsauthors
Frank AO,Walsh PW,Moore JE Jrdoi
10.1046/j.1525-1594.2002.07084.xsubject
Has Abstractpub_date
2002-07-01 00:00:00pages
614-21issue
7eissn
0160-564Xissn
1525-1594pii
aor7084journal_volume
26pub_type
杂志文章,评审abstract::A microcapsule suspension, a substitute for animal blood in hemolysis tests, has been developed for evaluation of the absolute hemolytic properties of circulatory artificial organs. The microcapsule suspension was made by dispersing microcapsule slurry into an ethylene glycol sodium chloride solution. The microcapsule...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.1999.06316.x
更新日期:1999-03-01 00:00:00
abstract::This study demonstrates in a novel way how volume and shape are restored to denervated degenerated muscles due to a special pattern of electrical stimulation. To this purpose, Spiral Computer Tomography (CT) and special image processing tools were used to develop a method to isolate the rectus femoris from other muscl...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2008.00610.x
更新日期:2008-08-01 00:00:00
abstract::Magnevad II is an improved version of Magnevad I and both are fourth-generation axial flow left ventricular assist devices. A major simplification has been implemented and tested. Magnevad I used a magnetically suspended rotor requiring active axial control. Magnevad II is completely passive but otherwise similar. A s...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2005.29113.x
更新日期:2005-10-01 00:00:00
abstract::As a preliminary investigation to establish a cryopreservation method suited for bioartificial livers (BALs), three-dimensional (3-D) cryopreservation experiments with fibroblasts were performed, in which the cells were firstly seeded into a porous scaffold, and the scaffold containing the cells was then cryopreserved...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2009.00933.x
更新日期:2010-07-01 00:00:00
abstract::The aim of the present study was to compare the effects of ProTaper Gold, WaveOne Gold, ProTaper Universal, and WaveOne instruments on the amount of apically extruded debris. Eighty mandibular premolar teeth with straight root canals were selected and assigned to four groups (n = 20). The root canals were instrumented...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.12675
更新日期:2016-08-01 00:00:00
abstract::For introduction of a left atrial (LA) cannula by the transseptal puncture technique, we examined the feasibility of using biplane transesophageal echocardiography (B-TEE). A transseptal puncture was performed on 15 patients (3 male; 12 female; mean age, 48.9 +/- 11.2 years) by B-TEE guide during percutaneous transven...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1992.tb00537.x
更新日期:1992-08-01 00:00:00
abstract::Twelve patients, 8 male and 4 female, aged from 26 to 70 years were studied. They were on hemodialysis (HD) 4 h three times weekly with cuprophan hollow fiber dialyzers (Gambro 120M) and dialysate containing 35 mEq/L of acetate. The study compares two random HD sessions on each patient. Sixty minutes prior to one rand...
journal_title:Artificial organs
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1111/j.1525-1594.1989.tb01551.x
更新日期:1989-10-01 00:00:00
abstract::The purpose of this study was the investigation of the usability and ergonomics of ventricular assist devices (VADs) in everyday usage. Patients with four different VAD types were observed. After implantation, instruction, and discharge from the hospital, the patients returned on a regular basis to the outpatient clin...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2009.00844.x
更新日期:2009-09-01 00:00:00
abstract::Cardiovascular disorders are the leading causes of mortality and morbidity in the developed world. Cell-based modalities have received considerable scientific attention over the last decade for their potential use in this clinical arena. This review was intended as a brief overview on the subject of therapeutic potent...
journal_title:Artificial organs
pub_type: 杂志文章,评审
doi:10.1111/j.1525-1594.2006.00209.x
更新日期:2006-04-01 00:00:00
abstract::Tissue engineering can improve the former limitations of artificial organs. This article reports the long-term clinical results of grafts constructed with fragmented autologous adipose tissue. We did a retrospective analysis of a series of 53 patients with lower leg ischemia that received 69 fragmented adipose tissue ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.2001.025003218.x
更新日期:2001-03-01 00:00:00
abstract::The treatment of rheumatoid arthritis remains difficult and often controversial. Plasma exchange has been advocated in some cases. In the present study 71 sessions of double filtration plasmapheresis (DFPP) were performed in 21 patients with rheumatoid arthritis in an average of 3.7 +/- 1.1 sessions per patient within...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1997.tb00344.x
更新日期:1997-02-01 00:00:00
abstract::Rotary blood pumps are emerging as a viable technology for total artificial hearts, and the development of physiological control algorithms is accelerated with new evaluation environments. In this article, we present a novel hybrid mock circulation loop (HMCL) designed specifically for evaluation of rotary total artif...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.12380
更新日期:2014-09-01 00:00:00
abstract::Oxidative stress is crucial in red blood cell (RBC) damage induced by activated neutrophils in in vitro experiments. The aim of the study was to evaluate whether the bioincompatibility phenomena occurring during hemodialysis (HD) (where neutrophil activation with increased free radical production is well documented) m...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.2000.06432.x
更新日期:2000-01-01 00:00:00
abstract::Bovine pericardium is a widely utilized biomaterial. Usually, after harvesting, it is advantageous that the pericardium be immersed in glycerol to improve its shelf life. This can induce some degree of toxicity in the material. The studies were performed in compliance with the rules of ISO 10993 and OECD 487, in the b...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2008.00542.x
更新日期:2008-04-01 00:00:00
abstract::We aim to evaluate clinical outcomes of emergent extracorporeal membrane oxygenation (ECMO) implantation in newborns with life-threatening meconium aspiration syndrome (MAS) in peripheral hospitals with Hub and Spoke (HandS) setting. We retrospectively reviewed all neonates presenting with MAS, with no other comorbidi...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.13270
更新日期:2019-01-01 00:00:00
abstract::Using an ex vivo model, the effects of membrane composition and surface area on both the complement system (as reflected by plasma C3a levels) and platelets [as indicated by plasma concentrations of thromboxane B2 (TXB2) and platelet factor 4 (PF4)] were studied. In this model, polyacrylonitrile (PAN) was associated w...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1987.tb02648.x
更新日期:1987-04-01 00:00:00
abstract::To overcome the weak mechanical properties of cell/hydrogel composites, a poly(DL-lactic-co-glycolic acid) sandwiched adipose-derived stem cell (ADSC)/fibrin construct was fabricated using a step-by-step mold/extraction method to generate the middle smooth muscle layer of natural blood vessels. A pulse bioreactor with...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2010.01137.x
更新日期:2011-06-01 00:00:00
abstract::Implantation of left ventricular assist devices typically requires cardiopulmonary bypass support, which is associated with postoperative complications. A novel suture-less inflow cannula, which can be implanted without bypass, uses mild myocardial compression to seal the interface, however, this may lead to necrosis ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.13018
更新日期:2018-05-01 00:00:00
abstract::Sponge-type small-diameter vascular grafts were fabricated from a medical-grade polyurethane, Pellethane 2363-80A, by utilization of a salt casting technique. The grafts were compliance matched with a storage modulus of 0.53 +/- 0.08 MPa. The luminal surface of grafts was modified with a thin layer ( approximately 40 ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2003.07141.x
更新日期:2003-12-01 00:00:00
abstract::For the last few years we have attempted to separate and isolate from biological fluids the uremic Middle Molecules (MM). The first step in the treatment of plasma is an ultrafiltration through AN69 membrane. The samples are fractionated by Sephadex G-15 chromatography into 9 peaks "a" to "i' under precise conditions ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:
更新日期:1981-01-01 00:00:00
abstract::In chronic cardiomyopathy, mechanical circulatory support (MCS) plays an increasingly important role for children as the shortage of suitable donor hearts increases waiting time on the transplant list. We report our experience with the paracorporal Berlin Heart EXCOR System (Berlin Heart AG, Berlin, Germany) used as a...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.12062
更新日期:2013-08-01 00:00:00
abstract::The purpose of this paper is to review the pathways of hydrogen ion production and removal due to intermediary metabolism. The principal method of analysis employed was one based on a theoretical approach because it is the most accurate and has the broadest application. In the absence of hypoxia and insulin deficiency...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1982.tb04126.x
更新日期:1982-11-01 00:00:00
abstract::Thousands of ventricular assist devices (VADs) currently provide circulatory support to patients worldwide, and dozens of heart pump designs for adults and pediatric patients are under various stages of development in preparation for translation to clinical use. The successful bench-to-bedside development of a VAD inv...
journal_title:Artificial organs
pub_type: 杂志文章,评审
doi:10.1111/aor.12600
更新日期:2016-06-01 00:00:00
abstract::A magnetically levitated (maglev) centrifugal blood pump (CBP), intended for use as a ventricular assist device, needs to be highly durable and reliable for long-term use without any mechanical failure. Furthermore, maglev CBPs should be small enough to be implanted into patients of various size and weight. We have de...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2006.00202.x
更新日期:2006-03-01 00:00:00
abstract::Recent studies show that oxytocin has various effects on cellular behaviors. Oxytocin is reported to stimulate cardiomyogenesis of embryonic stem cells and endothelial cell proliferation. Mesenchymal stem cells (MSCs) are widely used for cardiac repair, and we elucidated the effect of oxytocin on umbilical cord derive...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2009.00894.x
更新日期:2010-06-01 00:00:00
abstract::This study deals with the design of a controller for cycling induced by functional electrical stimulation. The controller will be exploitable in the rehabilitation of hemiparetic patients who need to recover motor symmetry. It uses the pulse width as the control variable in the stimulation of the two legs in order to ...
journal_title:Artificial organs
pub_type: 临床试验,杂志文章
doi:10.1111/j.1525-1594.2009.00941.x
更新日期:2010-08-01 00:00:00
abstract::Capillary membrane filters are devices commonly used for plasmapheresis and recirculating detoxification systems, including plasmaseparation units. Besides clinical trials and case reports, research on plasmafiltration techniques is carried out using in vitro systems. Notably, such hemoperfused in vitro systems requir...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.2003.07132.x
更新日期:2003-07-01 00:00:00
abstract::Experiments have been successfully performed culminating in functional, vascularized, three-dimensional cardiac muscle tissue. Past experience in tissue engineering has led us to the understanding that cell seeding density plays a critical role in the formation and function of both in vitro and in vivo engineered tiss...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2008.00591.x
更新日期:2008-09-01 00:00:00
abstract::Temporary and immediately usable vascular access is a vital need in treating uremic patients. Subclavian vein cannulation, although a major progress, has been associated with significant morbidity and mortality. Accordingly, for the last 2.5 years the authors have been developing an alternative technique consisting of...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1986.tb02587.x
更新日期:1986-10-01 00:00:00
abstract::Although the debate still continues over the effectiveness of pulsatile versus nonpulsatile perfusion, it has been clearly proven that there are several significant physiological benefits of pulsatile perfusion during cardiopulmonary bypass (CPB) compared to nonpulsatile perfusion. However, the components of the extra...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.1998.06017.x
更新日期:1998-08-01 00:00:00