Cytotoxicity of two novel formulations of calcium phosphate cements: a comparative in vitro study.

Abstract:

:The purpose was to evaluate the cytotoxicity of two novel formulations (alpha and beta) of calcium phosphate cements. Positive control, represented by a commercial hydroxyapatite cement, and negative control were included for comparative purposes. A continuous lineage of fibroblastic cells was used, and the effect of the tested materials on both cell proliferation and viability was assessed by counting cell number on hemocytometer and by the trypan blue exclusion test, respectively. Study design attempted to simulate clinical use by allowing direct and indirect contact of cells and cements. Results were analyzed by the Kruskal-Wallis test and indicated that the beta formulation was extremely cytotoxic (P < 0.001), because this material induced the greatest reduction on cell proliferation and viability. The alpha formulation behaved similarly to the positive control regarding its effect on cell proliferation and viability. Thus, it is concluded that alpha formulation has promise for further evaluation of its behavior in vivo.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Rossa C Jr,Marcantonio E Jr,Santos LA,Boschi AO,Raddi MS

doi

10.1111/j.1525-1594.2005.29022.x

subject

Has Abstract

pub_date

2005-02-01 00:00:00

pages

114-21

issue

2

eissn

0160-564X

issn

1525-1594

pii

AOR29022

journal_volume

29

pub_type

杂志文章
  • Ferritin: a reliable indicator of iron supplementation in patients on chronic hemodialysis/hemofiltration treatment?

    abstract::Four hundred and forty-two serum ferritin determinations were performed in 144 patients on chronic intermittent hemodialysis treatment with intravenous iron substitution and/or oral iron substitution. Iron substitution should be done individually according to regular serum ferritin determinations. Intravenous iron sub...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1981.tb03980.x

    authors: Müller HA,Schneider H,Hövelborn U,Streicher E

    更新日期:1981-05-01 00:00:00

  • Experimental high-volume hemofiltration with predilutional tris-hydroxymethylaminomethane for correction of low tidal volume ventilation-induced acidosis.

    abstract::The most common method of controlling acidemia during lung-protective ventilation is CO₂ removal with an extracorporeal lung assist (ECLA) system. Another possibility to prevent acidemia is based on intravenous (i.v.) application of tris-hydroxymethyl-aminomethane (3 mol/L, THAM) buffer, which can bind hydrogen proton...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2011.01204.x

    authors: Russ M,Deja M,Ott S,Bedarf J,Keckel T,Hiebl B,Wagner JJ,Unger JK

    更新日期:2011-06-01 00:00:00

  • Aortic root physiology late after a "perfect" ross operation: magnetic resonance imaging study of three operative techniques.

    abstract::In order to define physiological properties of the autograft root, magnetic resonance imaging (MRI) findings relative to three different operative techniques were compared with those of control subjects. Twenty-three patients, 18/5 M/F, aged 32 ± 9 years, underwent MRI assessment of the aortic root. Patients with norm...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2011.01202.x

    authors: Luciani GB,Viscardi F,Puppini G,Faggian G,Mazzucco A

    更新日期:2011-12-01 00:00:00

  • A bridge from short-term to long-term left ventricular assist device--experimental verification of a physiological controller.

    abstract::A physiological controller is a key component to optimize the performance of left ventricular assist devices (LVADs) from short term to long term (10-20 years). The difficulties of its design lie in the inaccurate modeling of any particular human cardiovascular system because of limited knowledge, the large fluctuatio...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2004.07381.x

    authors: Wu Y,Allaire PE,Tao G,Adams M,Liu Y,Wood H,Olsen DB

    更新日期:2004-10-01 00:00:00

  • Estimation of phosphene spatial variability for visual prosthesis applications.

    abstract::Visual prostheses are the focus of intensive research efforts to restore some measure of useful vision to blind or near-blind patients. The development of such technology is being guided to an extent by tools that simulate prosthesis behavior for healthy sighted subjects in order to assess system requirements and conf...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00878.x

    authors: Obeid I,Veraart C,Delbeke J

    更新日期:2010-05-01 00:00:00

  • High cell-density culture system of hepatocytes entrapped in a three-dimensional hollow fiber module with collagen gel.

    abstract::A compact three-dimensional (3D) module is needed for hepatocyte culture in order to develop an effective hybrid artificial liver system that can retain hepatocellular structure and differentiated functions. We treated the 3D module with collagen gel to entrap rat hepatocytes. This method yielded a high hepatocellular...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1995.tb02310.x

    authors: Takeshita K,Ishibashi H,Suzuki M,Yamamoto T,Akaike T,Kodama M

    更新日期:1995-02-01 00:00:00

  • Hemolytic evaluation using polyurethane microcapsule suspensions in circulatory support devices: normalized index of hemolysis comparisons of commercial centrifugal blood pumps.

    abstract::We have been developing some types of microcapsule suspensions with polyurethane membranes to evaluate the absolute hemolytic characteristics of the centrifugal blood pumps used in circulatory support devices such as artificial hearts. In order to facilitate/realize hemolysis testing on centrifugal blood pumps that ha...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2007.00503.x

    authors: Maruyama O,Yamaguchi K,Nishida M,Onoguchi T,Tsutsui T,Jikuya T,Yamane T

    更新日期:2008-02-01 00:00:00

  • Measurement of the closing behavior of the björk-shiley monoleaflet mechanical heart valve with an electrohydraulic total artificial heart.

    abstract::When cavitation occurs near a material surface of a mechanical heart valve (MHV), pits on the surface of the MHV and hemolysis are caused. Therefore, it is very important to investigate the possibility of the occurrence of cavitation in an MHV. To study the possibility of cavitation occurrence in a 25 mm Björk-Shiley ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2003.06981.x

    authors: Lee H,Tsukiya T,Homma A,Taenaka Y,Tatsumi E,Takano H

    更新日期:2003-08-01 00:00:00

  • A Meta-Analysis of Renal Function After Adult Cardiac Surgery With Pulsatile Perfusion.

    abstract::The aim of this meta-analysis was to determine whether pulsatile perfusion during cardiac surgery has a lesser effect on renal dysfunction than nonpulsatile perfusion after cardiac surgery in randomized controlled trials. MEDLINE, EMBASE, and the Cochrane Central Register of Controlled Trials were used to identify ava...

    journal_title:Artificial organs

    pub_type: 杂志文章,meta分析

    doi:10.1111/aor.12452

    authors: Nam MJ,Lim CH,Kim HJ,Kim YH,Choi H,Son HS,Lim HJ,Sun K

    更新日期:2015-09-01 00:00:00

  • End-point temperature of rewarming after hypothermic cardiopulmonary bypass in pediatric patients.

    abstract::In an attempt to find an adequate end-point rewarming temperature after hypothermic cardiopulmonary bypass (CPB), 50 pediatric patients who underwent cardiac surgery were randomly assigned for the end-point rectal rewarming temperature at either 35.5 (Group 1) or 37.0 degrees C (Group 2). The patients' rectal temperat...

    journal_title:Artificial organs

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/j.1525-1594.2005.00149.x

    authors: Kim WG,Yang JH

    更新日期:2005-11-01 00:00:00

  • A newly designed adapter for testing an ex vivo mitral valve apparatus.

    abstract::Few instruments are currently available to test mitral valve function in an ex vivo state due to the technical difficulties involved. To investigate the native ex vivo mitral valve or prosthetic mitral valve with chordae, we developed a mitral valve adapter with an annulus suturing portion and 2 papillary muscle sutur...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06293.x

    authors: Katoh T,Ikeda N,Nishi K,Gohra H,Hamano K,Noda H,Fujimura Y,Esato K

    更新日期:1999-10-01 00:00:00

  • Eosinophilia in hemodialysis patients.

    abstract::Thirteen percent of 99 patients undergoing maintenance hemodialysis showed an increased predialysis peripheral blood eosinophil count (mean value of 828 cells/mm3, range 410-2,710). Patients with eosinophilia were predominantly male and evidenced more frequent elevation of total plasma IgE levels. Otherwise, no differ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1987.tb02635.x

    authors: Friedberg M,Joffe P,Nielsen B,Nielsen LP

    更新日期:1987-04-01 00:00:00

  • Potential mechanisms for muscle-powered cardiac support.

    abstract::Biomechanical actuation of an implanted ventricular assist device (VAD) is an attractive means of providing long-term circulatory support. Studies show that energy from electrically stimulated skeletal muscle can, in principle, be used to provide tether-free cardiac assistance without the need for percutaneous driveli...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2010.01170.x

    authors: Trumble DR

    更新日期:2011-07-01 00:00:00

  • Assessment of skeletal muscle ventricle tissue blood flow using positron emission tomography.

    abstract::In this pilot study, we assessed the feasibility of using positron emission tomography (PET) imaging for in vivo measurement of skeletal muscle ventricle (SMV) tissue blood flow. In 4 dogs, with SMVs prepared from their latissimus dorsi muscle, we quantified SMV tissue blood flow by PET and related it to the tissue fl...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors: Singh TP,Greer K,Muzik O,Hammond RL,Stephenson LW,Di Carli MF

    更新日期:2001-04-01 00:00:00

  • Central Extracorporeal Life Support With Left Ventricular Decompression to Berlin Heart Excor: A Reliable "Bridge to Bridge" Strategy in Crash and Burn Patients.

    abstract::The aim of this study was to compare patients with severe biventricular heart failure who underwent Berlin Heart Excor implantation with (cardiogenic shock [CS] status) or without the need for preoperative extracorporeal life support (ECLS) as a bridge to long-term device. A total of 40 consecutive patients with sever...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12792

    authors: Weymann A,Farag M,Sabashnikov A,Fatullayev J,Zeriouh M,Schmack B,Arif R,Müller F,Alt C,Raake P,Prakash Patil N,Popov AF,Rüdiger Simon A,Karck M,Ruhparwar A,Heidelberg-Cologne-Harefield Cardiothoracic Transplantation & Mecha

    更新日期:2017-06-01 00:00:00

  • Cellulose acetate beads activate the complement system but inactivate the anaphylatoxins generated.

    abstract::The generation of anaphylatoxins, particularly C5a, is important in extracorporeal circulation therapies such as granulocyte/monocyte apheresis, which activates the complement system and elevates C5a levels. However, no side effects of granulocyte/monocyte apheresis using cellulose acetate beads have been reported. To...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00995.x

    authors: Takeda Y,Ohba M,Ueno M,Saniabadi AR,Wakabayashi I

    更新日期:2010-12-01 00:00:00

  • Surface modification of silicone rubber membrane by plasma induced graft copolymerization as artificial cornea.

    abstract::In this study a highly biocompatible polymer membrane was prepared by surface modification. An artificial cornea was also developed for clinical applications. Silicone rubber (SR) membrane was grafted with hydrophilic monomers such as 2-hydroxyethyl methacrylate (HEMA) and acrylic acid by plasma induced grafted polyme...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1996.tb00661.x

    authors: Hsiue GH,Lee SD,Chang PC

    更新日期:1996-11-01 00:00:00

  • Influence of hydration state on plasma volume changes during ultrafiltration.

    abstract::To assess the influence of hydration state on plasma volume (PV) changes during ultrafiltration, 11 clinically normhydrated patients on maintenance hemodialysis were studied intraindividually during 2 hydration states differing by 2-15% of lean body mass (LBM). Plasma volume was measured continually during a 15-min ul...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1995.tb02352.x

    authors: Wizemann V,Leibinger A,Mueller K,Nilson A

    更新日期:1995-05-01 00:00:00

  • Effect of heparin, platelets, activated platelets, platelet fragments, and hematocrit on activated clotting time.

    abstract::Activated clotting time (ACT) is the most commonly used laboratory test to control the heparin effect during extracorporeal techniques. The study was undertaken in order to test in vitro the influence of heparin, platelet count, hematocrit, platelet fragmentation, and platelet activation on ACT. Blood was drawn from v...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06552.x

    authors: Girardi L,Sudi K,Muntean W

    更新日期:2000-07-01 00:00:00

  • Microcirculation and artificial heart research.

    abstract::Small blood vessels may play a more important role in artificial heart (AH) recipients than ever suspected before. Observations of elevated total peripheral resistance, low hematocrit, reduced oncotic pressure, high circulating blood volume, and arterial pulsations with nonpulsatile devices require consideration of pe...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1988.tb01529.x

    authors: Lübbe AS

    更新日期:1988-02-01 00:00:00

  • Development of a DNA immunoadsorbent: coupling DNA on sepharose 4FF by an efficient activation method.

    abstract::To remove anti-DNA antibodies from a patient's plasma with systemic lupus erythematosus (SLE), a DNA immunoadsorbent was developed by covalently coupling calf thymus DNA on activated Sepharose 4FF. Sepharose 4FF was activated with 5-norbornene-2,3-dicarboximido carbonochloridate (Cl-CO-ONB), which was proven to be a v...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06618.x

    authors: Kong DL,Schuett W,Boeden HF,Kunkel S,Holtz M,Matic G,Yamada R,Yu YT,Klinkmann H

    更新日期:2000-11-01 00:00:00

  • Angiographic and pathological studies on regression of coronary atherosclerosis of FH patients who received LDL-apheresis treatment.

    abstract::We report on the most recent data confirming the angiographic and pathological efficacy of LDL-apheresis for coronary atherosclerosis of a familial hypercholesterolemia (FH) patient using collected data of a large number of cases and especially of one autopsy case. Changes in coronary artery stenosis have been assesse...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1992.tb00289.x

    authors: Koga N,Iwata Y,Yamamoto A

    更新日期:1992-04-01 00:00:00

  • Research of flow dynamics and occlusion condition in roller pump systems used for ventricular assist.

    abstract::Roller pumps have been widely used in the ventricular assist field for many years, while the significant hemolysis caused by its mechanical stress is still a fundamental problem. Although the usual under-occlusion setting was considered as an effective method to reduce the hemolysis rate, its nonocclusive condition of...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13790

    authors: Zhou Y,Sun B,Chen M,Cui C

    更新日期:2020-07-31 00:00:00

  • Intensive Home Hemodialysis: An Eye at the Past Looking for the Hemodialysis of the Future.

    abstract::Multiple observational studies along with a limited number of randomized clinical trials suggest that intensive hemodialysis (IHD) not only improves outcomes for uremic patients undergoing chronic dialysis but does so with a more favorable cost/benefit ratio compared with conventional hemodialysis. As a result of this...

    journal_title:Artificial organs

    pub_type: 历史文章,杂志文章,评审

    doi:10.1111/aor.12458

    authors: Naso A,Scaparrotta G,Naso E,Calò LA

    更新日期:2015-09-01 00:00:00

  • Intestinal tissue oxygenation and tumor necrosis factor-alpha release during systemic blood flow changes in pigs with left ventricular assist devices.

    abstract::We previously demonstrated that tumor necrosis factor-alpha (TNF-alpha) increased following a reduction in systemic blood flow to 60% or less of the original cardiac output using a left ventricular assist device (LVAD). The aim of this study was to investigate the effect of reducing systemic blood flow on tissue oxyge...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2001.025001053.x

    authors: Uozaki Y,Dihmis WC,Yamauchi H,Moczar M,Miyama M,Pasteau F,Tixier D,Bambang SL,Loisance DY

    更新日期:2001-01-01 00:00:00

  • Prevention of right heart failure after left ventricular assist device implantation by phosphodiesterase 5 inhibitor.

    abstract::Right ventricular (RV) function immediately after left ventricular assist device (LVAD) implantation is a crucial prognostic factor. RV failure is linked to increased mortality and worse outcome. A phosphodiesterase 5 inhibitor, sildenafil, was shown to decrease pulmonary vascular resistance and pulmonary artery press...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12277

    authors: Hamdan R,Mansour H,Nassar P,Saab M

    更新日期:2014-11-01 00:00:00

  • Evaluation of double filtration plasmapheresis, thermofiltration, and low-density lipoprotein adsorptive methods by crossover test in the treatment of familial hypercholesterolemia patients.

    abstract::A comparative assessment has been made regarding efficacy and safety of the double filtration plasmapheresis (DFPP), thermofiltration (TFPP), and low-density lipoprotein (LDL) adsorptive (PA) methods by making a crossover test on heterozygous familial hypercholesterolemia patients. Treatments by DFPP, TFPP (secondary ...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1525-1594.1996.tb04448.x

    authors: Suzuki M,Yamane S,Matsugane T,Nobuto T,Azuma N,Nishide T,Shinomiya M,Saito K,Sasaki N,Nosé Y

    更新日期:1996-04-01 00:00:00

  • Development of an intravascular pumping oxygenator using a new silicone membrane.

    abstract::A new intravascular pumping oxygenator (IVPO) was developed for intravascular gas exchange and circulatory assistance in critically ill patients with respiratory and circulatory failure. The IVPO utilizes new silicone hollow fibers (diameter, 1 mm; membrane width, 50 microns) and consists of two driving tubes for the ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb00703.x

    authors: Sueda T,Fukunaga S,Morita S,Sueshiro M,Hirai S,Okada K,Orihashi K,Matsuura Y

    更新日期:1997-01-01 00:00:00

  • Estimation of maximum ventricular elastance under assistance with a rotary blood pump.

    abstract::The maximum ventricular elastance is a reliable index for assessing the cardiac function from changes in its pressure-volume relationship. The advantage of this index is that it can represent the contractility of either unassisted hearts or native hearts assisted with rotary blood pumps. However, there are situations ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00876.x

    authors: Sugai TK,Tanaka A,Yoshizawa M,Shiraishi Y,Yambe T,Nitta S,Baba A

    更新日期:2010-05-01 00:00:00

  • Renal osteodystrophy in dialysis patients: diagnosis and treatment.

    abstract::This article reviews the clinical, biological, radiological, and pathological procedures and their respective indications for the practical diagnosis of the following various histological patterns of renal osteodystrophy: osteitis fibrosa due to parathyroid hormone (PTH) hypersecretion: osteomalacia or rickets due to ...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1046/j.1525-1594.1998.06198.x

    authors: Fournier A,Oprisiu R,Hottelart C,Yverneau PH,Ghazali A,Atik A,Hedri H,Said S,Sechet A,Rasolombololona M,Abighanem O,Sarraj A,El Esper N,Moriniere P,Boudailliez B,Westeel PF,Achard JM,Pruna A

    更新日期:1998-07-01 00:00:00