Surface modification of silicone rubber membrane by plasma induced graft copolymerization as artificial cornea.

Abstract:

:In this study a highly biocompatible polymer membrane was prepared by surface modification. An artificial cornea was also developed for clinical applications. Silicone rubber (SR) membrane was grafted with hydrophilic monomers such as 2-hydroxyethyl methacrylate (HEMA) and acrylic acid by plasma induced grafted polymerization. Surface properties of the SR were characterized using secondary ions mass spectra, Fourier transform infrared/attenuated total reflection, and element spectra for chemical analysis. The corneal epithelial (CE) cell was cultured in vitro, and penetrating keratoplasty of albino rabbit cornea (in vivo) was performed to evaluate biological properties of modified SR membranes. The ability of the CE cell to attach onto various SR membranes was observed by inverted microscopy. The proliferation of CE cell was conducted in approximately 96 h. Experimental results indicated that the attachment and growth of CE onto SR-g-pHEMA (75 micrograms/ cm2) is enhanced. The morphologies of an attached CE cell are similar to those of a primary CE cell. In the in vivo study, the depth of anterior chamber was maintained 2 weeks after penetrating keratoplasty was performed with a SR grafted with pHEMA (210 micrograms/cm2). This phenomenon displayed a high biocompatibility of modified SR membrane with the CE cell. Furthermore, results in this study provide a valuable reference for application of the modified SR for an artificial cornea.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Hsiue GH,Lee SD,Chang PC

doi

10.1111/j.1525-1594.1996.tb00661.x

subject

Has Abstract

pub_date

1996-11-01 00:00:00

pages

1196-207

issue

11

eissn

0160-564X

issn

1525-1594

journal_volume

20

pub_type

杂志文章
  • The roles of vascular smooth muscle cells in the aortic wall thinness under prolonged continuous flow left heart bypass.

    abstract::Aortic wall thinness was one of the most characteristic changes observed in experimental animals under prolonged continuous flow left heart bypass. The goal of this study was to determine the roles of smooth muscle cells in the vascular remodeling process in cases demonstrating aortic wall thinness under prolonged con...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2003.00022.x

    authors: Mizuno T,Nishinaka T,Ohnishi H,Tatsumi E,Tsukiya T,Oshikawa M,Shioya K,Takewa Y,Homma A,Takano H,Kitamura S,Taenaka Y

    更新日期:2003-10-01 00:00:00

  • Multi-field surface electrode for selective electrical stimulation.

    abstract::We designed a 24-field array and an on-line control box that selects which and how many of 24 fields will conduct electrical charge during functional electrical stimulation. The array was made using a conductive microfiber textile, silver two-component adhesive, and the conductive ink imprint on the polycarbonate. The...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2005.29075.x

    authors: Popović-Bijelić A,Bijelić G,Jorgovanović N,Bojanić D,Popović MB,Popović DB

    更新日期:2005-06-01 00:00:00

  • Modified DALI LDL-apheresis using trisodium citrate anticoagulation plus bicarbonate or lactate-buffered hemofiltration substitution fluids as primers.

    abstract:BACKGROUND:DALI (direct adsorption of lipids) is the first LDL-apheresis technique able to adsorb low-density lipoprotein (LDL) and lipoproteina) directly from whole blood. In the standard procedure, acid citrate dextrose (ACD-A) is used as anticoagulation and the adsorber is rinsed with a specially manufactured primin...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1046/j.1525-1594.2003.07104.x

    authors: Bosch T,Wendler T,Maschke H

    更新日期:2003-06-01 00:00:00

  • Temporary right heart assist: a minimally invasive approach.

    abstract::A surgical method for the implantation of a mechanical right ventricular assist device which avoids resternotomy/thoracotomy and related complications at the time of explantation is presented. In order to support the failing right heart, a Dacron vascular graft was sewn to the pulmonary artery. For venous drainage, a ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2012.01520.x

    authors: Schopka S,Haneya A,Rupprecht L,Camboni D,Schmid C,Hilker M

    更新日期:2012-08-01 00:00:00

  • Electrical pulse train and single pulse stimulation of the small intestine: acute and chronic studies in the dog.

    abstract::In vitro tests have shown that electric currents may lead either to relaxation or contraction of the bowel wall. Because voluntary changes of the intestinal motility could be useful in the treatment of intestinal disorders, we investigated the reactions elicited by electrostimulation of the small intestine in the inta...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1989.tb02846.x

    authors: Moritz A,Grundfest-Broniatowski S,Ilyes L,Kasick J,Jacobs G,Olsen E,Nosé Y

    更新日期:1989-04-01 00:00:00

  • Application of a pressure-relieving air compliance chamber in a single-pulsatile extracorporeal life support system: an experimental study.

    abstract::Nonpulsatile blood pumps are mainly used in extracorporeal life support systems. Although pulsating blood flow is known to be physiological, a pulsatile pump is not commonly applied in a circuit with a membrane oxygenator because of damage to the blood cells. The hypothesis that the placement of a pressure-relieving c...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2004.07341.x

    authors: Kim TS,Sun K,Lee KB,Lee HW,Baek KJ,Park SY,Son HS,Kim KT,Kim HM

    更新日期:2004-12-01 00:00:00

  • Percutaneous introduction of left atrial cannula for left heart bypass: utility of biplane transesophageal echocardiographic guidance for transseptal puncture.

    abstract::For introduction of a left atrial (LA) cannula by the transseptal puncture technique, we examined the feasibility of using biplane transesophageal echocardiography (B-TEE). A transseptal puncture was performed on 15 patients (3 male; 12 female; mean age, 48.9 +/- 11.2 years) by B-TEE guide during percutaneous transven...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1992.tb00537.x

    authors: Kyo S,Motoyama T,Miyamoto N,Noda H,Dohi Y,Omoto R

    更新日期:1992-08-01 00:00:00

  • Central Extracorporeal Life Support With Left Ventricular Decompression to Berlin Heart Excor: A Reliable "Bridge to Bridge" Strategy in Crash and Burn Patients.

    abstract::The aim of this study was to compare patients with severe biventricular heart failure who underwent Berlin Heart Excor implantation with (cardiogenic shock [CS] status) or without the need for preoperative extracorporeal life support (ECLS) as a bridge to long-term device. A total of 40 consecutive patients with sever...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12792

    authors: Weymann A,Farag M,Sabashnikov A,Fatullayev J,Zeriouh M,Schmack B,Arif R,Müller F,Alt C,Raake P,Prakash Patil N,Popov AF,Rüdiger Simon A,Karck M,Ruhparwar A,Heidelberg-Cologne-Harefield Cardiothoracic Transplantation & Mecha

    更新日期:2017-06-01 00:00:00

  • How to comply with the Food and Drug Administration's "Investigational Device Exemption (IDE)" regulations including an application form (revised January 1982).

    abstract::This is a revision of the IDE Application Form, "How to Comply with the Food and Drug Administration's New 'Investigational Device Exemption (IDE)' Regulations, Including an Application Form" originally published in Artificial Organs, Volume 4, Number 4, November 1980. This publication updates the IDE application form...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors:

    更新日期:1982-02-01 00:00:00

  • Implantation of the total artificial heart by lateral thoracotomy.

    abstract::Progress in the techniques for surgical implantation of the artificial heart has progressed in parallel with the technology and design of the prosthesis. In the author's first experience with total artificial heart (TAH) implantation (1968) a trans-sternal split was used opening the sixth intercostal space on the righ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1977.tb00984.x

    authors: Olsen DB,Fukumasu H,Kolff J,Nakagaki M,Finch LR,Kolff WJ

    更新日期:1977-11-01 00:00:00

  • A new technique to increase coronary flow. Preliminary report.

    abstract::This study was planned to investigate whether part of the energy produced by cardiac contraction to propel blood toward the systemic circulation can be used to increase the coronary flow in systole. Ten devices (I-X) designed to divert laterally part of a flow column (without substantially increasing resistance to flo...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1979.tb01080.x

    authors: Moulopoulos S,Stamatelopoulos S,Boufas D,Yannopoulos C,Marousis G,Kouvaras G

    更新日期:1979-11-01 00:00:00

  • Development of a flow estimation and control system of an implantable centrifugal blood pump for circulatory assist.

    abstract::A bypass flow rate estimation and control system (BECS) for an implantable centrifugal blood pump (ICBP) has been developed in our institute. The estimated flow rate (EF) of the ICBP was derived from the electric power consumption, the rotating speed of a motor, and the blood viscosity presumed by the hematocrit and b...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.06130.x

    authors: Wakisaka Y,Okuzono Y,Taenaka Y,Chikanari K,Endo S,Masuzawa T,Takano H

    更新日期:1998-06-01 00:00:00

  • Acceleration of peritoneal mass transport by drugs and hormones.

    abstract::The major restrictions to the transport of solute and solvent across the peritoneum are the limited peritoneal blood flow, area and permeability. Recent investigations have demonstrated that several vasoactive drugs influence transport parameters. Isoproterenol, nitroprusside, dipyridamole and dopamine exemplify drugs...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1979.tb01052.x

    authors: Maher JF

    更新日期:1979-08-01 00:00:00

  • Pump Speed Waveform Analysis to Detect Aortic Valve Opening in Patients on Ventricular Assist Device Support.

    abstract::As the aortic valve (AV) opens, the pump pressure head remains constant, which is reflected as a "notch/plateau" in pump pressure and flow signals. However, instantaneous flow estimation may be influenced by friction and is particularly difficult in axial pumps. Therefore, a new method to determine the duration of AV ...

    journal_title:Artificial organs

    pub_type: 杂志文章,多中心研究

    doi:10.1111/aor.12570

    authors: Hayward C,Lim CP,Schima H,Macdonald P,Moscato F,Muthiah K,Granegger M

    更新日期:2015-08-01 00:00:00

  • Venoarterial extracorporeal membrane oxygenation for postcardiotomy cardiogenic shock-A six-year service evaluation.

    abstract::Only a small number of English hospitals provide postcardiotomy venoarterial extracorporeal membrane oxygenation (VA-ECMO) and there are doubts about its efficacy and safety. The aim of this service evaluation was to determine local survival rates and report on patient demographics. This was a retrospective service ev...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13647

    authors: Charlesworth M,Garcia M,Head L,Barker JM,Ashworth AD,Barnard JB,Feddy L,Venkateswaran RV

    更新日期:2020-07-01 00:00:00

  • Behavior of endothelial cells cultured on Silastic and Dacron velour under flow conditions in vitro: implications for prelining vascular grafts with cells.

    abstract::Tissue-cultured bovine aortic endothelial cells were subjected to flow in an in vitro circulatory loop designed to simulate the flow and pressure conditions in the aorta. The cells were cultured under stationary conditions on tubes of fibronectin-coated Silastic or of Dacron velour. The tubes were then added to the fl...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1983.tb04156.x

    authors: Eskin SG,Navarro LT,O'Bannon W,DeBakey ME

    更新日期:1983-02-01 00:00:00

  • Double filtration plasmapheresis for the treatment of rheumatoid arthritis: a study of 21 cases.

    abstract::The treatment of rheumatoid arthritis remains difficult and often controversial. Plasma exchange has been advocated in some cases. In the present study 71 sessions of double filtration plasmapheresis (DFPP) were performed in 21 patients with rheumatoid arthritis in an average of 3.7 +/- 1.1 sessions per patient within...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb00344.x

    authors: Liu JD,Zhang C,Li WS,Lun LD

    更新日期:1997-02-01 00:00:00

  • Performance of baffled bubble blood oxygenators.

    abstract::Bubble blood oxygenators equipped with baffles of various types in the oxygenating column were studied. The rate of hemolysis, the volumetric coefficient for oxygen absorption into blood, and the fractional gas holdup were found to be affected mainly by the superficial gas velocity. When compared with the conventional...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1979.tb01032.x

    authors: Ohshima N,Yoshido F

    更新日期:1979-05-01 00:00:00

  • Transcutaneous monitoring of blood gas tensions in patients on intermittent peritoneal dialysis.

    abstract::A relative contraindication to intermittent peritoneal dialysis (IPD) is chronic lung disease. To evaluate whether the instillation of 2 L of fluid into the peritoneal cavity affects respiratory function, five IPD patients were studied in the supine position during the first 4 h of a routine IPD session. Blood gas ten...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1988.tb02768.x

    authors: Korzets Z,Pomeranz A,Shachor Y,Bernheim J

    更新日期:1988-06-01 00:00:00

  • Charged compounds of the glomerular filter and their role in normal and disordered permselectivity.

    abstract::Infusion into rats of the polycation hexadimethrine (HDM) leads to onset of massive proteinuria, which recovers when the infusion is stopped. Several lines of evidence indicate that the proteinuria results from binding of HDM to polyanions of the glomerular filter, with neutralization of shielding of their charges. To...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1987.tb02712.x

    authors: Hunsicker LG,Bertolatus JA

    更新日期:1987-12-01 00:00:00

  • Hepatocyte culture between woven capillary networks: a microscopy study.

    abstract::A multi-compartment capillary membrane culture model with independently perfused three-dimensionally woven capillaries was developed for immobilization of hepatocytes in bioreactors. This enables spatial restructuring of cells and enhanced mass transfer performance with more efficient oxygenation and metabolite exchan...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1994.tb02181.x

    authors: Gerlach J,Schnoy N,Smith MD,Neuhaus P

    更新日期:1994-03-01 00:00:00

  • Adult polycystic kidney disease: who needs hospital follow-up?

    abstract::Clinical data from 120 adult patients with genetically undifferentiated polycystic kidney disease who had been followed up for more than 3 months (range 3-172) were reviewed in order to try to identify clinical indicators that might predict deterioration in renal function. They were split into two groups dependent on ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2012.01441.x

    authors: Griveas I,Bishop K,World M

    更新日期:2012-07-01 00:00:00

  • Cellulose acetate beads activate the complement system but inactivate the anaphylatoxins generated.

    abstract::The generation of anaphylatoxins, particularly C5a, is important in extracorporeal circulation therapies such as granulocyte/monocyte apheresis, which activates the complement system and elevates C5a levels. However, no side effects of granulocyte/monocyte apheresis using cellulose acetate beads have been reported. To...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00995.x

    authors: Takeda Y,Ohba M,Ueno M,Saniabadi AR,Wakabayashi I

    更新日期:2010-12-01 00:00:00

  • Influence of flow design on microcirculation in conditions of undulation pump-left ventricle assist device testing.

    abstract::To study the microvessels in bulbar conjunctiva, we conducted an experiment in goat with a pneumatically driven left heart bypass pump, which was replaced with an undulation pump-left ventricle assist device for 9 days. Three flow patterns were tested: complete pulsatile, continuous, and percentage of pulsatile. We st...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2006.00244.x

    authors: Dobsák P,Novakova M,Baba A,Vasku J,Isoyama T,Saito I,Abe Y,Chinzei T,Imachi K

    更新日期:2006-06-01 00:00:00

  • The human genome efforts and the cDNA project.

    abstract::Molecular biology has been moving swiftly toward clarifying the entire genome of organisms, including human. The human genome efforts that promote this transaction are characterized by the large-scale, high throughput production of data about the structure of the genome of the molecular level and its computer-assisted...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1111/j.1525-1594.1996.tb04553.x

    authors: Matsubara K

    更新日期:1996-08-01 00:00:00

  • Motor control in the human spinal cord.

    abstract::Features of the human spinal cord motor control are described using two spinal cord injury models: (i) the spinal cord completely separated from brain motor structures by accidental injury; (ii) the spinal cord receiving reduced and altered supraspinal input due to an incomplete lesion. Systematic studies using surfac...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2005.29038.x

    authors: Dimitrijevic MR,Persy I,Forstner C,Kern H,Dimitrijevic MM

    更新日期:2005-03-01 00:00:00

  • Clinical Assessment of Histidine-Tryptophan-Ketoglutarate Solution and Modified St. Thomas' Solution in Pediatric Cardiac Surgery of Tetralogy of Fallot.

    abstract::The objective of this study is to compare the myocardium protective effect of Bretschneider's histidine-tryptophan-ketoglutarate (HTK) solution versus Modified St. Thomas' (STH) solution in pediatric cardiac surgery of Tetralogy of Fallot (TOF). Seventy-seven pediatric patients of TOF who received the total surgical r...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12771

    authors: Wang ZH,An Y,Du MC,Qin TJ,Liu YB,Xu HZ,Yang LQ

    更新日期:2017-05-01 00:00:00

  • Plasma administration to defibrinogenated dogs during extracorporeal circulation.

    abstract::Plasma, in an amount corresponding to 0.05 gm fibrinogen/Kg of body weight, was administered during one hour to defibrinogenated dogs subjected to extracorporeal circulation. Four blood filters included in the extracorporeal circuit were removed one by one at 30-minute intervals. The prefilter pressures rose gradually...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1979.tb03809.x

    authors: Berglin E,Hansson HA,William-Olsson G

    更新日期:1979-02-01 00:00:00

  • Antimicrobial Wound Dressing Containing Silver Sulfadiazine With High Biocompatibility: In Vitro Study.

    abstract::Many patients all over the world suffer from acute wounds caused by traumas or burns. In most crucial cases, skin regeneration cannot be promoted spontaneously, and skin grafts are applied as the main treatment. However, this therapy has some drawbacks which motivate researchers to develop wound dressings. In this stu...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12682

    authors: Mohseni M,Shamloo A,Aghababaei Z,Vossoughi M,Moravvej H

    更新日期:2016-08-01 00:00:00

  • A novel in vitro assessment of tissue valve calcification by a continuous flow type method.

    abstract::A dynamic flow type testing to study calcification was self-designed to investigate calcification in bioprosthetic heart valves. The apparatus consists of a container into which leaflets from a porcine aortic valve are placed, a chamber that contains calcium solution, and a peristaltic pump that provides a continuous ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06482-2.x

    authors: Park JC,Hwang YS,Han DW,Suh H

    更新日期:2000-02-01 00:00:00