Evaluation of membrane oxygenators and reservoirs in terms of capturing gaseous microemboli and pressure drops.

Abstract:

:An increasing amount of evidence points to cerebral embolization during cardiopulmonary bypass (CPB) as the principal etiologic factor of neurologic complications. In this study, the capability of capturing and classification of gaseous emboli and pressure drop of three different membrane oxygenators (Sorin Apex, Terumo Capiox SX25, Maquet QUADROX) were measured in a simulated adult model of CPB using a novel ultrasound detection and classification quantifier system. The circuit was primed with 1000 mL heparinized human packed red blood cells and 1000 mL lactated Ringer's solution (total volume 2000 mL, corrected hematocrit 26-28%). After the injection of 5 mL air into the venous line, an Emboli Detection and Classification Quantifier was used to simultaneously record microemboli counts at post-pump, post-oxygenator, and post-arterial filter sites. Trials were conducted at normothermic (35 degrees C) and hypothermic (25 degrees C) conditions. Pre-oxygenator and post-oxygenator pressure were recorded in real time and pressure drop was calculated. Maquet QUADROX membrane oxygenator has the lowest pressure drops compared to the other two oxygenators (P < 0.001). The comparison among the three oxygenators indicated better capability of capturing gaseous emboli with the Maquet QUADROX and Terumo Capiox SX25 membrane oxygenator and more emboli may pass through the Sorin Apex membrane oxygenator. Microemboli counts uniformly increased with hypothermic perfusion (25 degrees C). Different types of oxygenators and reservoirs have different capability of capturing gaseous emboli and transmembrane pressure drop. Based on this investigation, Maquet QUADROX membrane oxygenator has the lowest pressure drop and better capability for capturing gaseous microemboli.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Guan Y,Palanzo D,Kunselman A,Undar A

doi

10.1111/j.1525-1594.2009.00955.x

subject

Has Abstract

pub_date

2009-11-01 00:00:00

pages

1037-43

issue

11

eissn

0160-564X

issn

1525-1594

pii

AOR955

journal_volume

33

pub_type

杂志文章
  • Testosterone and hemoglobin in hemodialysis male and female patients.

    abstract::It has been speculated that testosterone stimulates erythropoiesis. We hypothesized that hemoglobin levels in hemodialysis (HD) patients are associated with serum testosterone concentrations. Testosterone, hemoglobin, and other biochemical parameters were measured in a representative sample of 98 chronic HD patients (...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12218

    authors: Ekart R,Taskovska M,Hojs N,Bevc S,Hojs R

    更新日期:2014-07-01 00:00:00

  • Gas-exchange function of a preprimed pediatric oxygenator stored for one year for emergency cardiopulmonary bypass.

    abstract::To save priming time and perform more rapid initiation of emergency cardiopulmonary bypass for acute cardiopulmonary failure, an extracorporeal circuit with a hollow-fiber oxygenator (EL-2000 for pediatric use; Kurary Co. Ltd., Osaka, Japan) was preprimed, and the gas-exchange function was evaluated after 1 year of st...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1992.tb00331.x

    authors: Otsu T,Terasaki H,Choi H,Tajiri A,Okamoto T,Matsuyama K,Morioka T

    更新日期:1992-10-01 00:00:00

  • Complication profile of the Berlin Heart EXCOR biventricular support in children.

    abstract::In chronic cardiomyopathy, mechanical circulatory support (MCS) plays an increasingly important role for children as the shortage of suitable donor hearts increases waiting time on the transplant list. We report our experience with the paracorporal Berlin Heart EXCOR System (Berlin Heart AG, Berlin, Germany) used as a...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12062

    authors: Schweiger M,Schrempf J,Sereinigg M,Prenner G,Tscheliessnigg KH,Wasler A,Krumnikel J,Gamillschegg A,Knez I

    更新日期:2013-08-01 00:00:00

  • Evaluation of Combined Extracorporeal Life Support and Continuous Renal Replacement Therapy on Hemodynamic Performance and Gaseous Microemboli Handling Ability in a Simulated Neonatal ECLS System.

    abstract::The objective of this study was to evaluate the hemodynamic performance and gaseous microemboli (GME) handling ability of a simulated neonatal extracorporeal life support (ECLS) circuit with an in-line continuous renal replacement therapy (CRRT) device. The circuit consisted of a Maquet RotaFlow centrifugal pump or HL...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12987

    authors: Shank KR,Profeta E,Wang S,O'Connor C,Kunselman AR,Woitas K,Myers JL,Ündar A

    更新日期:2018-04-01 00:00:00

  • Biological evaluation of liposome-encapsulated hemoglobin surface-modified with a novel PEGylated nonphospholipid amphiphile.

    abstract::Traumatic injury is often associated with hemorrhagic shock. Liposome-encapsulated hemoglobin (LEH) is being developed as an artificial oxygen carrier to address post-hemorrhage oxygen and volume deficit. Here, we report a new composition of LEH based on the use of polyethylene glycol (PEG2K ) conjugated with nonphosp...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12304

    authors: Yadav VR,Nag O,Awasthi V

    更新日期:2014-08-01 00:00:00

  • Percutaneous introduction of left atrial cannula for left heart bypass: utility of biplane transesophageal echocardiographic guidance for transseptal puncture.

    abstract::For introduction of a left atrial (LA) cannula by the transseptal puncture technique, we examined the feasibility of using biplane transesophageal echocardiography (B-TEE). A transseptal puncture was performed on 15 patients (3 male; 12 female; mean age, 48.9 +/- 11.2 years) by B-TEE guide during percutaneous transven...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1992.tb00537.x

    authors: Kyo S,Motoyama T,Miyamoto N,Noda H,Dohi Y,Omoto R

    更新日期:1992-08-01 00:00:00

  • Intravascular micropump for augmented liver perfusion: first in vivo experience.

    abstract::The aim of this study was to assess the in vivo performance of a new microaxial rotary blood pump developed for long-term intraportal implantation. The pump, measuring 7 mm in diameter, has a single stage impeller and is powered by a microelectric motor. The pump was implanted into the portal vein in 13 large white pi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2001.06772.x

    authors: Havlík R,Kerkhoffs W,Jiao LR,Schumacher O,Reul H,Habib N

    更新日期:2001-05-01 00:00:00

  • Quantification of the secondary flow in a radial coupled centrifugal blood pump based on particle tracking velocimetry.

    abstract::Secondary flow in the centrifugal blood pump helps to enhance the washout effect and to minimize thrombus formation. On the other hand, it has an adverse effect on pump efficiency. Excessive secondary flow may induce hemolytic effects. Understanding the secondary flow is thus important to the design of a compact, effi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2004.29012.x

    authors: Watanabe N,Masuda T,Iida T,Kataoka H,Fujimoto T,Takatani S

    更新日期:2005-01-01 00:00:00

  • Role of the BioMedicus pump and distal aortic perfusion in thoracoabdominal aortic aneurysm repair.

    abstract::We reviewed the role of the BioMedicus pump in the reduction of neurologic complications following the repair of Type 1 and Type 2 thoracoabdominal aortic aneurysms. Since 1991, we have used several different methods for the repair of thoracoabdominal aortic aneurysms including simple cross-clamping, selective use of ...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:

    authors: Safi HJ

    更新日期:1996-06-01 00:00:00

  • Implantation of the total artificial heart by lateral thoracotomy.

    abstract::Progress in the techniques for surgical implantation of the artificial heart has progressed in parallel with the technology and design of the prosthesis. In the author's first experience with total artificial heart (TAH) implantation (1968) a trans-sternal split was used opening the sixth intercostal space on the righ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1977.tb00984.x

    authors: Olsen DB,Fukumasu H,Kolff J,Nakagaki M,Finch LR,Kolff WJ

    更新日期:1977-11-01 00:00:00

  • High cell-density culture system of hepatocytes entrapped in a three-dimensional hollow fiber module with collagen gel.

    abstract::A compact three-dimensional (3D) module is needed for hepatocyte culture in order to develop an effective hybrid artificial liver system that can retain hepatocellular structure and differentiated functions. We treated the 3D module with collagen gel to entrap rat hepatocytes. This method yielded a high hepatocellular...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1995.tb02310.x

    authors: Takeshita K,Ishibashi H,Suzuki M,Yamamoto T,Akaike T,Kodama M

    更新日期:1995-02-01 00:00:00

  • Influence of Instruments Used in Root Canal Preparation on Amount of Apically Extruded Debris.

    abstract::The aim of the present study was to compare the effects of ProTaper Gold, WaveOne Gold, ProTaper Universal, and WaveOne instruments on the amount of apically extruded debris. Eighty mandibular premolar teeth with straight root canals were selected and assigned to four groups (n = 20). The root canals were instrumented...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12675

    authors: Karataş E,Ersoy İ,Gündüz HA,Uygun AD,Kol E,Çakıcı F

    更新日期:2016-08-01 00:00:00

  • Oral treatment for jaundice using immobilized bilirubin oxidase.

    abstract::Jaundice is characterized by an excessive accumulation of bilirubin in the blood and tissues. A novel approach to reduce plasma levels of bilirubin by blocking its enterohepatic circulation was investigated. The treatment consisted of oral administration of immobilized bilirubin oxidase, which could oxidize bilirubin ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1992.tb00527.x

    authors: Soltys PJ,Mullon C,Langer R

    更新日期:1992-08-01 00:00:00

  • The mitroflow pericardial valve. First results of a follow-up study.

    abstract::One hundred eighty-eight Mitroflow pericardial valves, implanted on 166 patients from March 1983 to December 1986, have been followed for a total of 4316 patients x months. Mortality rate in the first three postoperative months is approximately 10% related to noncardiac complications. One hundred forty-nine patients a...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1988.tb02781.x

    authors: Loisance D,Hillion ML,Cachera JP

    更新日期:1988-08-01 00:00:00

  • Heart valve inspired and multi-stream aortic cannula: Novel designs for cardiopulmonary bypass improvement in neonates.

    abstract::In a typical open-heart surgery, the blood flow through the aortic cannula is a critical element of the cardiopulmonary bypass (CPB) procedure. Especially for the neonatal and pediatric CPB flow conditions, the need for small hydraulic diameter and large blood flow results confined turbulent jet flow regimes that exac...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13462

    authors: Rasooli R,Pekkan K

    更新日期:2019-10-01 00:00:00

  • Mathematical modeling of fluid dynamics in pulsatile cardiopulmonary bypass.

    abstract::The design criteria of an extracorporeal circuit suitable for pulsatile flow are quite different and more entangled than for steady flow. The time and costs of the design process could be reduced if mutual influences between the pulsatile pump and other extracorporeal devices were considered without experimental trial...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2003.47197.x

    authors: Pennati G,Fiore GB,Laganà K,Fumero R

    更新日期:2004-02-01 00:00:00

  • Use of clinical guidelines for treatment of anemia among hemodialysis patients.

    abstract::Changing financial incentives have strongly influenced dosing patterns of recombinant human erythropoietin (rHuEPO) since its introduction in 1989. Although guidelines for prescribing rHuEPO exist, the extent to which they are adhered to is unknown. Using a retrospective cohort observational study design, the factors ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06495.x

    authors: Thamer M,Richard CM,Klinkmann J,Ivanovich P,Lang G,Cotter DJ

    更新日期:2000-02-01 00:00:00

  • In Vitro Evaluation of an Alternative Neonatal Extracorporeal Life Support Circuit on Hemodynamic Performance and Bubble Trap.

    abstract::The objective of this study was to evaluate an alternative neonatal extracorporeal life support (ECLS) circuit with a RotaFlow centrifugal pump and Better-Bladder (BB) for hemodynamic performance and gaseous microemboli (GME) capture in a simulated neonatal ECLS system. The circuit consisted of a Maquet RotaFlow centr...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12748

    authors: Spencer SB,Wang S,Woitas K,Glass K,Kunselman AR,Ündar A

    更新日期:2017-01-01 00:00:00

  • Hemodynamic evaluation of a new left ventricular assist device: an integrated cardioassist catheter as a pulsatile left ventricle-femoral artery bypass.

    abstract::We developed a new left ventricular (LV) assist catheter (transaortic valve from LV to femoral artery) that is implemented percutaneously and exerted as a synchronous pulsatile partial LV flow support with conventional intraaortic balloon pump (IABP) driving system and centrifugal pump system. We investigated whether ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1992.tb00311.x

    authors: Ide H,Yamaguchi A,Ino T,Matsumoto H,Fujimasa I

    更新日期:1992-06-01 00:00:00

  • Development of cellulose-DNA immunoadsorbent.

    abstract::The aim of this study was to prepare a DNA immunoadsorbent for the specific, extracorporeal removal of anti-DNA antibodies from the blood of patients with systemic lupus erythematosus (SLE) and rheumatoid arthritis (RA). Two kinds of cellulose beads were applied as a carrier. Calf thymus DNA was covalently coupled to ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2002.06721.x

    authors: Kong D,Schuett W,Dai J,Kunkel S,Holtz M,Yamada R,Yu Y,Klinkmann H

    更新日期:2002-02-01 00:00:00

  • Reduction of driveline infections through doubled driveline tunneling of left ventricular assist devices.

    abstract::The durability of ventricular assist device (VAD) therapy improved steadily over the past years. However, driveline infections remain a challenge. To test whether an improved surgical implantation technique may lower the incidence of infections, we analyzed all patients receiving a VAD implantation in the years 2008 a...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12036

    authors: Fleissner F,Avsar M,Malehsa D,Strueber M,Haverich A,Schmitto JD

    更新日期:2013-01-01 00:00:00

  • Rotary blood pump flow spontaneously increases during exercise under constant pump speed: results of a chronic study.

    abstract::Many types of rotary blood pumps and pump control methods have recently been developed with the goal of clinical use. From experiments, we know that pump flow spontaneously increases during exercise without changing pump control parameters. The purpose of this study was to determine the hemodynamics associated with th...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06426.x

    authors: Akimoto T,Yamazaki K,Litwak P,Litwak KN,Tagusari O,Mori T,Antaki JF,Kameneva MV,Watach MJ,Umezu M,Tomioka J,Kormos RL,Koyanagi H,Griffith BP

    更新日期:1999-08-01 00:00:00

  • Forward osmosis process for dialysis fluid regeneration.

    abstract::In a preliminary experiment, 38% of the spent dialysis fluid water was reclaimed by a forward osmosis process through a cellulose triacetate membrane. The simplicity of forward osmosis and its minimal external energy requirements may allow the construction of a small bulk device that can reclaim a considerable portion...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00816.x

    authors: Talaat KM

    更新日期:2009-12-01 00:00:00

  • Pulsatile in vitro simulation of the pediatric univentricular circulation for evaluation of cardiopulmonary assist scenarios.

    abstract::The characteristic depressed hemodynamic state and gradually declining circulatory function in Fontan patients necessitates alternative postoperative management strategies incorporating a system level approach. In this study, the single-ventricle Fontan circulation is modeled by constructing a practical in vitro bench...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00951.x

    authors: Dur O,Lara M,Arnold D,Vandenberghe S,Keller BB,DeGroff C,Pekkan K

    更新日期:2009-11-01 00:00:00

  • Cerebral oxygen metabolism during total body flow and antegrade cerebral perfusion at deep and moderate hypothermia.

    abstract::The aim of this study is to evaluate the effect of temperature on cerebral oxygen metabolism at total body flow bypass and antegrade cerebral perfusion (ACP). Neonatal piglets were put on cardiopulmonary bypass (CPB) with the initial flow rate of 200mL/kg/min. After cooling to 18°C (n=6) or 25°C (n=7), flow was reduce...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2010.01131.x

    authors: Sasaki T,Boni L,Riemer RK,Yeung JT,Ramamoorthy C,Beckman R,Gisner C,Shuttleworth P,Hanley FL,Reddy VM

    更新日期:2010-11-01 00:00:00

  • The application of immobilized enzymes in an artificial liver support system.

    abstract::A novel method of extracorporeal support for fulminant liver failure is reported whereby the most important detoxification processes of the liver are reproduced in an enzyme reactor. Most of the endogenous toxins involved in hepatic coma can be deactivated directly by conjugation with a hydrophilic residue such as glu...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1979.tb03801.x

    authors: Brunner G,Holloway CJ,Lösgen H

    更新日期:1979-02-01 00:00:00

  • The influence of the dialysate flow rate on hollow fiber hemodialyzer performance.

    abstract::The clearance characteristics of two sizes of hemodialyzers (0.9 m2 and 1.5 m2) from the same range of products have been studied over the dialysate flow range of 500-3,000 ml/min to establish the device's overall mass transfer resistance characteristics. The results obtained demonstrate a difference in the overall ma...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1995.tb02279.x

    authors: Allen R,Frost TH,Hoenich NA

    更新日期:1995-11-01 00:00:00

  • The type of aortic cannula and membrane oxygenator affect the pulsatile waveform morphology produced by a neonate-infant cardiopulmonary bypass system in vivo.

    abstract::Although the debate still continues over the effectiveness of pulsatile versus nonpulsatile perfusion, it has been clearly proven that there are several significant physiological benefits of pulsatile perfusion during cardiopulmonary bypass (CPB) compared to nonpulsatile perfusion. However, the components of the extra...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.06017.x

    authors: Undar A,Lodge AJ,Daggett CW,Runge TM,Ungerleider RM,Calhoon JH

    更新日期:1998-08-01 00:00:00

  • Chaotic dynamics in circulation with Tohoku University vibrating flow pump.

    abstract::For the development of a totally implantable ventricular assist system (VAS), we have been developing the vibrating flow pump (VFP), which can generate oscillated blood flow with a relative high frequency (10-50 Hz) for a totally implantable system. In this study, the effects of left ventricular assistance with this u...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06288.x

    authors: Nitta S,Yambe T,Kobayashi S,Hashimoto H,Yoshizawa M,Mastuki H,Tabayashi K,Takeda H

    更新日期:1999-01-01 00:00:00

  • Visual three-dimensional representation of beat-to-beat electrocardiogram traces during hemodiafiltration.

    abstract::This study evaluated the usefulness of the three-dimensional representation of electrocardiogram traces (3DECG) to reveal acute and gradual changes during a full session of hemodiafiltration (HDF) in end-stage renal disease (ESRD) patients. Fifteen ESRD patients were included (six men, nine women, age 46 ± 19 years ol...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2011.01382.x

    authors: Rodriguez-Fernandez R,Infante O,Perez-Grovas H,Hernandez E,Ruiz-Palacios P,Franco M,Lerma C

    更新日期:2012-06-01 00:00:00