Influence of Instruments Used in Root Canal Preparation on Amount of Apically Extruded Debris.

Abstract:

:The aim of the present study was to compare the effects of ProTaper Gold, WaveOne Gold, ProTaper Universal, and WaveOne instruments on the amount of apically extruded debris. Eighty mandibular premolar teeth with straight root canals were selected and assigned to four groups (n = 20). The root canals were instrumented using ProTaper Gold, WaveOne Gold, ProTaper Universal, and WaveOne systems. Eppendorf tubes containing apically extruded debris were weighed three times, and mean values were calculated. The net mass of the extruded debris was calculated by subtracting the initial mass from the final mass. The groups were compared using one-way analysis of variance and Tukey's post hoc tests at a significance level of P < 0.05. The PTG group extruded less debris than the PTU group, and the WOG group extruded less debris than the WO group (P < 0.05). All the instrumentation systems tested in the present study were associated with apical extrusion of debris.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Karataş E,Ersoy İ,Gündüz HA,Uygun AD,Kol E,Çakıcı F

doi

10.1111/aor.12675

subject

Has Abstract

pub_date

2016-08-01 00:00:00

pages

774-7

issue

8

eissn

0160-564X

issn

1525-1594

journal_volume

40

pub_type

杂志文章
  • Plasma administration to defibrinogenated dogs during extracorporeal circulation.

    abstract::Plasma, in an amount corresponding to 0.05 gm fibrinogen/Kg of body weight, was administered during one hour to defibrinogenated dogs subjected to extracorporeal circulation. Four blood filters included in the extracorporeal circuit were removed one by one at 30-minute intervals. The prefilter pressures rose gradually...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1979.tb03809.x

    authors: Berglin E,Hansson HA,William-Olsson G

    更新日期:1979-02-01 00:00:00

  • Novel approach for designing a low weight hip implant used in total hip arthroplasty adopting skeletal design techniques.

    abstract::Aseptic loosening is the major cause of failure of hip implants after total hip arthroplasty. Stress shielding of the femur is known to be the principal factor involved in the aseptic loosening of hip implants. Solid stems are found to have a greater rigidity; therefore, they transfer less load proximally, which resul...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2010.01145.x

    authors: Sivarasu S,Beulah P,Mathew L

    更新日期:2011-06-01 00:00:00

  • Plasma exchange and immunoadsorption for removal of antibodies prior to ABO incompatible bone marrow transplant.

    abstract::ABO incompatible allogeneic bone marrow transplants can be performed successfully to treat patients with leukemia or aplastic anemia. These transplants carry no great risk of rejection or graft-versus-host disease, however, some method must be used to avoid acute hemolysis at the time of infusion of ABO incompatible m...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1981.tb03998.x

    authors: Bensinger WI

    更新日期:1981-08-01 00:00:00

  • Intra-Aortic Balloon Pump Support in the Isolated Beating Porcine Heart in Nonischemic and Ischemic Pump Failure.

    abstract::The blood pressure changes induced by the intra-aortic balloon pump (IABP) are expected to create clinical improvement in terms of coronary perfusion and myocardial oxygen consumption. However, the measured effects reported in literature are inconsistent. The aim of this study was to investigate the influence of ische...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12470

    authors: Schampaert S,van Nunen LX,Pijls NH,Rutten MC,van Tuijl S,van de Vosse FN,van 't Veer M

    更新日期:2015-11-01 00:00:00

  • Melt Electrospun Bilayered Scaffolds for Tissue Integration of a Suture-Less Inflow Cannula for Rotary Blood Pumps.

    abstract::Implantation of left ventricular assist devices typically requires cardiopulmonary bypass support, which is associated with postoperative complications. A novel suture-less inflow cannula, which can be implanted without bypass, uses mild myocardial compression to seal the interface, however, this may lead to necrosis ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13018

    authors: Liao S,Theodoropoulos C,Blackwood KA,Woodruff MA,Gregory SD

    更新日期:2018-05-01 00:00:00

  • Reduction of driveline infections through doubled driveline tunneling of left ventricular assist devices.

    abstract::The durability of ventricular assist device (VAD) therapy improved steadily over the past years. However, driveline infections remain a challenge. To test whether an improved surgical implantation technique may lower the incidence of infections, we analyzed all patients receiving a VAD implantation in the years 2008 a...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12036

    authors: Fleissner F,Avsar M,Malehsa D,Strueber M,Haverich A,Schmitto JD

    更新日期:2013-01-01 00:00:00

  • Association among serum fetuin-A level, coronary artery calcification, and bone mineral densitometry in maintenance hemodialysis patients.

    abstract::Patients with end-stage renal disease have a very high prevalence and extent of arterial calcification. A number of studies suggest that similar pathophysiologic mechanisms are responsible for development and progression of calcification of atherosclerotic plaque and bone formation. Fetuin-A is a potent calcification ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00814.x

    authors: Kirkpantur A,Altun B,Hazirolan T,Akata D,Arici M,Kirazli S,Turgan C

    更新日期:2009-10-01 00:00:00

  • The role of PI3K/Akt signaling pathway in non-physiological shear stress-induced platelet activation.

    abstract::The PI3K/Akt signaling pathway has been implicated in playing an important role in platelet activation during hemostasis and thrombosis involving platelet-matrix interaction and platelet aggregation. Its role in non-physiological shear stress (NPSS)-induced platelet activation relevant to high-shear blood contacting m...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13465

    authors: Chen Z,Li T,Kareem K,Tran D,Griffith BP,Wu ZJ

    更新日期:2019-09-01 00:00:00

  • Outcome analysis for prediction of intraaortic balloon pump support failure and long-term survival in high-risk patients undergoing mitral valve surgery.

    abstract::The outcome predictors of intra-aortic balloon pump (IABP) in patients who undergo mitral valve surgery remain unknown. This study aimed to retrospectively review valvular surgery in patients who received an IABP to identify the predictors of failure of IABP support and anticipate the necessary therapy. This retrospec...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13669

    authors: Liang M,Wang C,Feng K,Chen G,Wang K,Wu Z

    更新日期:2020-08-01 00:00:00

  • Usability and safety of ventricular assist devices: human factors and design aspects.

    abstract::The purpose of this study was the investigation of the usability and ergonomics of ventricular assist devices (VADs) in everyday usage. Patients with four different VAD types were observed. After implantation, instruction, and discharge from the hospital, the patients returned on a regular basis to the outpatient clin...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00844.x

    authors: Geidl L,Zrunek P,Deckert Z,Zimpfer D,Sandner S,Wieselthaler G,Schima H

    更新日期:2009-09-01 00:00:00

  • The SlideReactor--a simple hollow fiber based bioreactor suitable for light microscopy.

    abstract::Most bioartificial liver support systems are based on hollow fiber capillaries within modified dialysis cartridges or more sophisticated bioreactor constructions. Due to their design microscopic follow-up of reorganization and growth of tissue between the hollow fibers is not possible. The SlideReactor is a simple hol...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2005.29049.x

    authors: Sauer IM,Schwartlander R,Schmid J,Efimova E,Vondran FW,Kehr D,Pless G,Spinelli A,Brandenburg B,Hildt E,Neuhaus P

    更新日期:2005-03-01 00:00:00

  • Ferritin: a reliable indicator of iron supplementation in patients on chronic hemodialysis/hemofiltration treatment?

    abstract::Four hundred and forty-two serum ferritin determinations were performed in 144 patients on chronic intermittent hemodialysis treatment with intravenous iron substitution and/or oral iron substitution. Iron substitution should be done individually according to regular serum ferritin determinations. Intravenous iron sub...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1981.tb03980.x

    authors: Müller HA,Schneider H,Hövelborn U,Streicher E

    更新日期:1981-05-01 00:00:00

  • Research of flow dynamics and occlusion condition in roller pump systems used for ventricular assist.

    abstract::Roller pumps have been widely used in the ventricular assist field for many years, while the significant hemolysis caused by its mechanical stress is still a fundamental problem. Although the usual under-occlusion setting was considered as an effective method to reduce the hemolysis rate, its nonocclusive condition of...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13790

    authors: Zhou Y,Sun B,Chen M,Cui C

    更新日期:2020-07-31 00:00:00

  • Artificial cells with emphasis on cell encapsulation of genetically engineered cells.

    abstract::Artificial cells are prepared in the laboratory for medical and biotechnological applications. Encapsulated cells are being studied for the treatment of diabetes, liver failure, and other conditions. More recently, there have been extensive studies into the use of encapsulated genetically engineered cells for gene the...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.06243.x

    authors: Chang TM

    更新日期:1998-11-01 00:00:00

  • Hemodynamic evaluation of a new left ventricular assist device: an integrated cardioassist catheter as a pulsatile left ventricle-femoral artery bypass.

    abstract::We developed a new left ventricular (LV) assist catheter (transaortic valve from LV to femoral artery) that is implemented percutaneously and exerted as a synchronous pulsatile partial LV flow support with conventional intraaortic balloon pump (IABP) driving system and centrifugal pump system. We investigated whether ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1992.tb00311.x

    authors: Ide H,Yamaguchi A,Ino T,Matsumoto H,Fujimasa I

    更新日期:1992-06-01 00:00:00

  • Analysis of left ventricular impedance in comparison with ultrasound images.

    abstract::Cardiac monitoring of ventricular assist devices (VADs) is important for detecting heart failure risks, such as critical arrhythmia and ventricular fibrillation, and for supplying data that are useful for hemodynamic control. Specifically, impedance cardiograms (ICGs) are especially beneficial because they have no eff...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2011.01381.x

    authors: Choi SW,Park SM

    更新日期:2012-05-01 00:00:00

  • The use of electrolyzed solutions for the cleaning and disinfecting of dialyzers.

    abstract::Recently, the use of electrolyzed solutions has attracted considerable interest in Japan. This study investigates the efficiency of electrolyzed solutions as disinfecting agents (DA) in the reuse of dialyzers and compares their efficiency to that of other disinfectants currently in use. The following 3 methods were em...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06611.x

    authors: Tanaka N,Tanaka N,Fujisawa T,Daimon T,Fujiwara K,Yamamoto M,Abe T

    更新日期:2000-12-01 00:00:00

  • Paper is a compatible bed for rat hepatocytes.

    abstract::To develop an effective hybrid bioartificial liver (BAL) device, the material of the scaffold is very important to support hepatocytes that have both growth ability and hepatic differentiated functions. In this study we used paper (Kimwipe, Kimberly-Clark Corp., Roswell, GA, U.S.A.) as a scaffold. Primary hepatocytes ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06506.x

    authors: Mizuguchi T,Mitaka T,Sato F,Mochizuki Y,Hirata K

    更新日期:2000-04-01 00:00:00

  • LDL apheresis: a novel technique (LIPOCOLLECT 200).

    abstract::Therapeutic means to lower Lp(a) are limited. The most effective method to reduce plasma Lp(a) concentration significantly is therapeutic apheresis, namely, low-density lipoprotein (LDL) lipoprotein(a) (Lp(a)) apheresis. A novel technique based on reusable LDL adsorber called Lipocollect 200 (Medicollect, Rimbach, Ger...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00959.x

    authors: Stefanutti C,Di Giacomo S,Mazzarella B,Castelli A

    更新日期:2009-12-01 00:00:00

  • Feasibility of extracorporeal on-line large-scale plasma adsorptions on protein A-sepharose columns in cancer patients.

    abstract::The feasibility of extracorporeal adsorption of 1.5-3 L plasma on protein A-Sepharose was investigated in six patients with advanced cancer. Anticoagulation with heparin was associated with respiratory distress syndrome in two patients, most likely caused by complement activation as indicated by a transient leukopenia...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1984.tb04247.x

    authors: Wallmark A,Grubb A,Freiburghaus C,Flodgren P,Husberg B,Lindholm T,Lindström C,Thysell H,Sjögren HO

    更新日期:1984-02-01 00:00:00

  • Improved mechanism for capturing muscle power for circulatory support.

    abstract::Although it is now understood that trained skeletal muscle can generate enough steady-state power to provide significant circulatory support, there are currently no means by which to tap this endogenous energy source to aid the failing heart. To that end, an implantable muscle energy converter (MEC) has been construct...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1111/j.1525-1594.2005.29108.x

    authors: Trumble DR,Melvin DB,Byrne MT,Magovern JA

    更新日期:2005-09-01 00:00:00

  • Multi-field surface electrode for selective electrical stimulation.

    abstract::We designed a 24-field array and an on-line control box that selects which and how many of 24 fields will conduct electrical charge during functional electrical stimulation. The array was made using a conductive microfiber textile, silver two-component adhesive, and the conductive ink imprint on the polycarbonate. The...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2005.29075.x

    authors: Popović-Bijelić A,Bijelić G,Jorgovanović N,Bojanić D,Popović MB,Popović DB

    更新日期:2005-06-01 00:00:00

  • Double filtration plasmapheresis for the treatment of rheumatoid arthritis: a study of 21 cases.

    abstract::The treatment of rheumatoid arthritis remains difficult and often controversial. Plasma exchange has been advocated in some cases. In the present study 71 sessions of double filtration plasmapheresis (DFPP) were performed in 21 patients with rheumatoid arthritis in an average of 3.7 +/- 1.1 sessions per patient within...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb00344.x

    authors: Liu JD,Zhang C,Li WS,Lun LD

    更新日期:1997-02-01 00:00:00

  • Myocardial protection in pediatric cardiac surgery.

    abstract::The combination of hypothermia and potassium cardioplegic arrest has become the most common method of myocardial protection in the evolution of myocardial protection. This review focuses on myocardial protection in pediatric cardiac surgery. In the 1980s, blood was added to cardioplegia solution in order to supply the...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1111/aor.12029

    authors: Turkoz R

    更新日期:2013-01-01 00:00:00

  • Baroreflex sensitivity of an arterial wall during rotary blood pump assistance.

    abstract::It is well known that the baroreflex system is one of the most important indicators of the pathophysiology in hypertensive patients. We can check the sensitivity of the baroreflex by observing heart rate (HR) responses; however, there is no simple diagnostic method to measure the arterial behavior in the baroreflex sy...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00864.x

    authors: Yambe T,Imachi K,Shiraishi Y,Yamaguchi T,Shibata M,Kameyama T,Yoshizawa M,Sugita N

    更新日期:2009-09-01 00:00:00

  • Estimation of theophylline clearance during continuous arteriovenous hemofiltration.

    abstract::Pharmacologic agents and other non-protein-bound compounds smaller than 5,000 daltons have the potential to be removed by continuous arteriovenous hemofiltration (CAVH). A proposed method for estimating drug clearance by CAVH (ClCAVH) equates ultrafiltrate clearance to the product of the sieving coefficient and the av...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1990.tb02997.x

    authors: Horton MW,Godley PJ,Moore ES,Fineg J,Gillespie WR

    更新日期:1990-12-01 00:00:00

  • Antithrombin replacement during extracorporeal membrane oxygenation.

    abstract::Heparin remains the predominant anticoagulant during extracorporeal membrane oxygenation (ECMO). Heparin acts by potentiating the anticoagulant effect of antithrombin (ATIII). Acquired ATIII deficiency, common in pediatric patients requiring ECMO, may result in ineffective anticoagulation with heparin. ATIII replaceme...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2011.01384.x

    authors: Niebler RA,Christensen M,Berens R,Wellner H,Mikhailov T,Tweddell JS

    更新日期:2011-11-01 00:00:00

  • Femoro-femoral versus atrio-aortic extracorporeal membrane oxygenation: selecting the ideal cannulation technique.

    abstract::Veno-arterial extracorporeal membrane oxygenation (ECMO) may be implanted using peripheral ECMO (pECMO) or central ECMO (cECMO) cannulation techniques. The aim of this study was to compare the outcome between these two cannulation techniques. A retrospective study was performed at Düsseldorf University Hospital from O...

    journal_title:Artificial organs

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/aor.12245

    authors: Saeed D,Stosik H,Islamovic M,Albert A,Kamiya H,Maxhera B,Lichtenberg A

    更新日期:2014-07-01 00:00:00

  • Transient rise in serum soluble Fas (APO-1/CD95) in patients undergoing cardiac surgery.

    abstract::The Fas molecule, also designated APO-1/CD95, belongs to the tumor necrosis factor (TNF) receptor family. It is a widely expressed membrane-anchored protein that induces apoptosis by Fas/Fas ligand (Fas-L) mediation. It was reported that Fas-mediated apoptosis plays an important role in regulation of the immune system...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06591.x

    authors: Kawahito K,Misawa Y,Fuse K

    更新日期:2000-08-01 00:00:00

  • Results of the European clinical trial of Arrow CorAide left ventricular assist system.

    abstract::The aim of this study was to evaluate the safety and performance of the Arrow CorAide left ventricular assist system (LVAS) (Arrow International, Reading, PA, USA), a continuous-flow left ventricular assist device, as bridge to transplantation or recovery as well as destination therapy in patients with New York Heart ...

    journal_title:Artificial organs

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1111/j.1525-1594.2012.01539.x

    authors: Saeed D,Arusoglu L,Gazzoli F,Hetzer R,Morshius M,Alloni A,Viganò M,Koerfer R,Golding LA,El Banayosy A

    更新日期:2013-02-01 00:00:00