Results of the European clinical trial of Arrow CorAide left ventricular assist system.

Abstract:

:The aim of this study was to evaluate the safety and performance of the Arrow CorAide left ventricular assist system (LVAS) (Arrow International, Reading, PA, USA), a continuous-flow left ventricular assist device, as bridge to transplantation or recovery as well as destination therapy in patients with New York Heart Association (NYHA) class IV heart failure. Twenty-one patients were implanted with the CorAide LVAS between February 2005 and February 2006 in a prospective, multicenter, nonrandomized trial. Seventeen patients (81%) survived to >180 days or to transplantation. The cumulative time on device was 16.58 patient years (range 23-796 days, median 192 days). No intraoperative technical issues were observed at the time of implantation. Of the 21 implants, nine patients died on device, two were converted to other devices, and 10 were transplanted. Three patient deaths were attributed to pump polymer coating delamination. Postmortem device inspection determined delamination of the polymer coating on the pump's internal surface to be the cause of the late hemolysis and sudden fatal pump stops. No embolic or driveline infection event was recorded. The automatic flow control algorithm functioned reliably throughout the trial. Primary performance trial endpoint was achieved with 81% survival to 180 days or transplantation. Delamination of the polymer coating on the internal surface of the pump with resultant hemolysis and pump stops was the sole major device event in this trial. Elimination of the polymer coating and replacement with an amorphous carbon coating has resolved this in preclinical testing, prior to initiation of further clinical testing of this device.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Saeed D,Arusoglu L,Gazzoli F,Hetzer R,Morshius M,Alloni A,Viganò M,Koerfer R,Golding LA,El Banayosy A

doi

10.1111/j.1525-1594.2012.01539.x

subject

Has Abstract

pub_date

2013-02-01 00:00:00

pages

121-7

issue

2

eissn

0160-564X

issn

1525-1594

journal_volume

37

pub_type

杂志文章,多中心研究,随机对照试验
  • Ultrasonic pulsed Doppler blood flowmeter for use in extracorporeal circulation.

    abstract::In cardiac surgeries, it is frequently necessary to make the external blood circulation and oxygenation artificially. This procedure is called extracorporeal circulation (EC) or heart-lung bypass. During EC, one of the most important parameters, which demands continuous monitoring, is the blood flow. In many cases, th...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06532.x

    authors: Dantas RG,Costa ET

    更新日期:2000-03-01 00:00:00

  • Controlled delivery of low-dose bone morphogenetic protein-2 using heparin-conjugated fibrin in the posterolateral lumbar fusion of rabbits.

    abstract::The heparin-conjugated fibrin (HCF) system has been developed to deliver bone morphogenetic proteins (BMPs) for a long-term period and thus enhance bone regeneration. In the present study, we tested the effectiveness of the delivery system for spinal fusion with a very low dose of BMP-2. A total of 15 rabbits underwen...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2012.01578.x

    authors: Koo KH,Lee JM,Ahn JM,Kim BS,La WG,Kim CS,Im GI

    更新日期:2013-05-01 00:00:00

  • Investigation of the inherent left-right flow balancing of rotary total artificial hearts by means of a resistance box.

    abstract::With the incidence of end-stage heart failure steadily increasing, the need for a practical total artificial heart (TAH) has never been greater. Continuous flow TAHs (CFTAH) are being developed using rotary blood pumps (RBPs), leveraging their small size, mechanical simplicity, and excellent durability. To completely ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13631

    authors: Nestler F,Timms DL,Stevens M,Bradley AP,Wilson SJ,Kleinheyer M,Lovell N,Frazier OH,Cohn WE

    更新日期:2020-06-01 00:00:00

  • Intrinsic coagulation pathway in end-stage renal disease associated with spinal cord injury treated with hemodialysis.

    abstract::Plasma procoagulant activities of factors XII, XI, IX, and VIII and plasma concentrations of factor XII antigen and high molecular weight kininogen (HMK) were determined in nine men with chronic renal failure (CRF) associated with long-standing spinal cord injury (SCI) treated with hemodialysis. The results were compa...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1985.tb04366.x

    authors: Vaziri ND,Winer RL,Toohey J,Danviriyasup K,Alikhani S,Eltorai I,Gordon S,Paule P

    更新日期:1985-05-01 00:00:00

  • The analysis of driving mode influence on energy dissipation in pneumatic artificial heart chambers.

    abstract::The energy dissipated in blood or on a total artificial heart (TAH) chamber's elements directly or indirectly decreases the biological or technical safety of the TAH's work. The energetic analysis of the Polish total artificial heart (POLTAH) external work with the objective of estimating the valve and membrane roles ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.05074.x

    authors: Nawrat Z,Malota Z

    更新日期:1998-10-01 00:00:00

  • Development and characterization of a new stationary phase for an immunoadsorption wall.

    abstract::This study introduces a newly developed method for the formation of a stationary phase superficially embedded with immunoadsorbent, that is partially incomplete two-stage polymerization of acrylamide. Preliminary experimental studies show that binding activity of the immunoadsorbent was satisfactorily maintained after...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2005.29071.x

    authors: Yang TH

    更新日期:2005-05-01 00:00:00

  • Improved retention of endothelial cells seeded on polyurethane small-diameter vascular grafts modified by a recombinant RGD-containing protein.

    abstract::Sponge-type small-diameter vascular grafts were fabricated from a medical-grade polyurethane, Pellethane 2363-80A, by utilization of a salt casting technique. The grafts were compliance matched with a storage modulus of 0.53 +/- 0.08 MPa. The luminal surface of grafts was modified with a thin layer ( approximately 40 ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2003.07141.x

    authors: Hsu SH,Sun SH,Chen DC

    更新日期:2003-12-01 00:00:00

  • A computational study of the effects of inlet guide vanes on the performance of a centrifugal blood pump.

    abstract::This article presents computational studies on the effects of inlet guide vanes (IGVs) on the flow pattern and shear stress in a centrifugal blood pump. The effect of IGVs is to introduce a pre-swirl to fluid particles entering the impeller with the intention that the fluid particles will travel along the blade profil...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2002.06917.x

    authors: Chan WK,Wong YW,Yu SC,Chua LP

    更新日期:2002-06-01 00:00:00

  • Fluctuations of the hemodynamic derivatives during left ventricular assistance using oscillated blood flow.

    abstract::To analyze the autonomic nervous system during left heart bypass with a vibrating flow pump (VFP), fluctuations in hemodynamic derivatives were evaluated by the spectral analysis method using fast fourier transform methodology. After the left pleural cavity was opened through the fourth intercostal space under general...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors: Yambe T,Kobayashi S,Nanka S,Naganuma S,Nitta S,Matsuki H,Abe K,Yoshizawa M,Fukuju T,Tabayashi K,Takeda H,Hashimoto H

    更新日期:1996-06-01 00:00:00

  • Chronic animal experiment with magnetically suspended centrifugal pump.

    abstract::We have been developing a new type of centrifugal pump for long-term use. The magnetically suspended centrifugal pump (MSCP) contains no shaft and seal so that long life expectancy is predicted. Paracorporeal left ventricular (LV) assist circulation between the left atrium and the descending aorta was instituted using...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb03713.x

    authors: Yamada T,Nishimura K,Park CH,Kono S,Yuasa S,Tsukiya T,Akamatsu T,Matsuda K,Ban T

    更新日期:1997-07-01 00:00:00

  • Is low-intensity anticoagulant therapy possible with an open pivot valve?: analysis of its development.

    abstract::In 1976, the authors became the codevelopers of the first successful bileaflet heart valve which has become the standard in valvular surgery. However, there still remains a significant rate of thromboembolism and thrombosis which can be attributed to the inherent design of cavities in the pivot area. These cavities co...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2002.06999.x

    authors: Nicoloff DM,Friedberg HD,Villafaña MA

    更新日期:2002-05-01 00:00:00

  • Effects of hemodynamic conditions and valve sizing on leaflet bending stress in self-expanding transcatheter aortic valve: An in vitro study.

    abstract::Transcatheter aortic valve (TAV) replacement has become a viable alternative to surgery for high and intermediate risk patients with severe aortic stenosis. This technology may extend to the younger and lower risk patients. In this population, long-term durability of the TAV is key. Increased leaflet mechanical stress...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13654

    authors: Stanová V,Zenses AS,Thollon L,Kadem L,Barragan P,Rieu R,Pibarot P

    更新日期:2020-07-01 00:00:00

  • Use of Bedside Ultrasonography and Saline Flush Technique for Evaluation of Central Venous Catheter Placement in Children.

    abstract::Our study investigated the reliability of appearance of rapid atrial swirl flow (RASF) by ultrasonography (US) in the right atrium (RA), which occurred as a result of rapid isotonic saline infusion (RISI) into the central venous catheter (CVC), in predicting catheter tip position. This prospective observational study ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13281

    authors: Yesilbas O,Sevketoglu E,Kihtir HS,Talip Petmezci M,Akcay N,Kocoglu Barlas U,Palabiyik F

    更新日期:2018-12-01 00:00:00

  • Immunologic studies of hollow-fiber dialyzer extracts.

    abstract::Testing failed to detect free isocyanates in dialyzer rinses or significant levels of immunoglobulin E antibodies to isocyanate-protein conjugates in the serum of individuals reacting during hemodialysis with dialyzers containing Cuprophan membranes. Extended immunization of rabbits with Limulus lysate-reactive materi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1984.tb04298.x

    authors: Butcher BT,Reed MA,O'Neil CE,Leech S,Pearson FC

    更新日期:1984-08-01 00:00:00

  • The roles of vascular smooth muscle cells in the aortic wall thinness under prolonged continuous flow left heart bypass.

    abstract::Aortic wall thinness was one of the most characteristic changes observed in experimental animals under prolonged continuous flow left heart bypass. The goal of this study was to determine the roles of smooth muscle cells in the vascular remodeling process in cases demonstrating aortic wall thinness under prolonged con...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2003.00022.x

    authors: Mizuno T,Nishinaka T,Ohnishi H,Tatsumi E,Tsukiya T,Oshikawa M,Shioya K,Takewa Y,Homma A,Takano H,Kitamura S,Taenaka Y

    更新日期:2003-10-01 00:00:00

  • Complication profile of the Berlin Heart EXCOR biventricular support in children.

    abstract::In chronic cardiomyopathy, mechanical circulatory support (MCS) plays an increasingly important role for children as the shortage of suitable donor hearts increases waiting time on the transplant list. We report our experience with the paracorporal Berlin Heart EXCOR System (Berlin Heart AG, Berlin, Germany) used as a...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12062

    authors: Schweiger M,Schrempf J,Sereinigg M,Prenner G,Tscheliessnigg KH,Wasler A,Krumnikel J,Gamillschegg A,Knez I

    更新日期:2013-08-01 00:00:00

  • Binding of antithrombin to immobilized heparin under varying flow conditions.

    abstract::Rheologic factors are likely to influence the balance between thrombotic and antithrombotic forces at the level of the vascular wall. In this study, the effects of flow-velocity/wall shear stress on the interaction of antithrombin (AT) with surface-immobilized heparin were investigated. The binding of AT to low-affini...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors: Pasche B,Elgue G,Olsson P,Riesenfeld J,Rasmuson A

    更新日期:1991-12-01 00:00:00

  • Clinical evaluation of a new type of centrifugal pump.

    abstract::The major problems with existing centrifugal pumps are leakage, mechanical trauma, and thrombus formation. In consideration of these problems, a new compact centrifugal pump system was developed. The purpose of this study was to evaluate the new centrifugal pump system clinically. Ten patients underwent open heart sur...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1994.tb03403.x

    authors: Ninomiya J,Shoji T,Tanaka S,Ikeshita M,Ochi M,Yamauchi S,Yajima T,Yamauchi H,Sugimoto T,Aizawa T

    更新日期:1994-09-01 00:00:00

  • Effect of filtration leukocytapheresis therapy: modulation of white blood cell enzyme activities in patients with rheumatoid arthritis.

    abstract::We treated 12 patients with rheumatoid arthritis by filtration leukocytapheresis (FLCP) and evaluated its effect on leukocyte enzyme activities. We calculated the number of leukocytes removed and assessed the clinical response. We also evaluated the cellular enzyme activities of elastase and dipeptidylpeptidase IV (DP...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2002.06834.x

    authors: Yamasaki S,Ueki Y,Nakamura H,Yano M,Matsumoto K,Miyake S,Tominaga T,Tominaga M,Eguchi K

    更新日期:2002-04-01 00:00:00

  • Probing expert opinions on the future of kidney replacement therapies.

    abstract::Patients with kidney failure can only survive with some form of kidney replacement (transplant or dialysis). Unfortunately, innovations in kidney replacement therapy lag behind many other medical fields. This study compiles expert opinions on candidate technologies for future kidney replacement therapies. A worldwide ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13784

    authors: Pereira Cabral B,Bonventre JV,Wieringa F,Mota FB

    更新日期:2020-07-22 00:00:00

  • LDL apheresis: a novel technique (LIPOCOLLECT 200).

    abstract::Therapeutic means to lower Lp(a) are limited. The most effective method to reduce plasma Lp(a) concentration significantly is therapeutic apheresis, namely, low-density lipoprotein (LDL) lipoprotein(a) (Lp(a)) apheresis. A novel technique based on reusable LDL adsorber called Lipocollect 200 (Medicollect, Rimbach, Ger...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00959.x

    authors: Stefanutti C,Di Giacomo S,Mazzarella B,Castelli A

    更新日期:2009-12-01 00:00:00

  • Computational fluid dynamics and stent design.

    abstract::Stents are small, usually metallic tubes that are intended to prop open arteries blocked with atherosclerotic plaques. While stents have been used successfully in recent years, they still suffer from failure due to development of new tissue in stented segment (restenosis). Variations in the failure rates associated wi...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1046/j.1525-1594.2002.07084.x

    authors: Frank AO,Walsh PW,Moore JE Jr

    更新日期:2002-07-01 00:00:00

  • Effect of moisture on and kinetic features of the ultrafiltration rate of dialysis membrane.

    abstract::The kinetic features of ultrafiltration of cellulose dialysis membrane stored under various humidity and temperature conditions were studied to obtain basic information of shelf-life characteristics of dialyzers. The ultrafiltration rate (UFR) decreased with time and the UFR-time curve suggested that the UFR would app...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1981.tb04003.x

    authors: Sato H,Kidaka T

    更新日期:1981-08-01 00:00:00

  • Determination of plasma C3a des Arg levels after blood contact with foreign surfaces.

    abstract::The products of complement activation, including C3a, C4a, C5a, and their des Arg derivatives, have been used by many investigators as indicators of blood or foreign surface bioincompatibility, e.g., during hemodialysis. One problem encountered is that after extracorporeal circulation over some dialysis membranes very...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1986.tb02518.x

    authors: Spencer PC,Schmidt B,Gurland HJ

    更新日期:1986-02-01 00:00:00

  • Percutaneous introduction of left atrial cannula for left heart bypass: utility of biplane transesophageal echocardiographic guidance for transseptal puncture.

    abstract::For introduction of a left atrial (LA) cannula by the transseptal puncture technique, we examined the feasibility of using biplane transesophageal echocardiography (B-TEE). A transseptal puncture was performed on 15 patients (3 male; 12 female; mean age, 48.9 +/- 11.2 years) by B-TEE guide during percutaneous transven...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1992.tb00537.x

    authors: Kyo S,Motoyama T,Miyamoto N,Noda H,Dohi Y,Omoto R

    更新日期:1992-08-01 00:00:00

  • Research into the development of a wearable bioartificial kidney with a continuous hemofilter and a bioartificial tubule device using tubular epithelial cells.

    abstract::Current hemodialysis treatment is insufficient because of intermittent treatment and loss of tubular function. In order to overcome the loss of tubular function, a bioartificial kidney has been developed consisting of continuous hemofiltration (CHF) with 10 L/day of filtrate and a bioartificial tubule device using pro...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1525-1594.2004.07323.x

    authors: Saito A

    更新日期:2004-01-01 00:00:00

  • Metabolism and acid-base physiology.

    abstract::The purpose of this paper is to review the pathways of hydrogen ion production and removal due to intermediary metabolism. The principal method of analysis employed was one based on a theoretical approach because it is the most accurate and has the broadest application. In the absence of hypoxia and insulin deficiency...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1982.tb04126.x

    authors: Halperin ML

    更新日期:1982-11-01 00:00:00

  • An implantable two channel drop foot stimulator: initial clinical results.

    abstract::This article reports preliminary results of pilot studies of a new implantable two channel drop foot stimulator. The stimulator consists of an externally worn transmitter inductively coupled to an implanted receiver unit located in the lower leg, lateral and distal to the knee. The receiver is connected to electrodes ...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1046/j.1525-1594.2002.06949.x

    authors: Kenney L,Bultstra G,Buschman R,Taylor P,Mann G,Hermens H,Holsheimer J,Nene A,Tenniglo M,van der Aa H,Hobby J

    更新日期:2002-03-01 00:00:00

  • Ozone Prevents Cochlear Damage From Ischemia-Reperfusion Injury in Guinea Pigs.

    abstract::The cochlea is an end organ, which is metabolically dependent on a nutrient and oxygen supply to maintain its normal physiological function. Cochlear ischemia and reperfusion (IR) injury is considered one of the most important causes of human idiopathic sudden sensorineural hearing loss. The aim of the present study w...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12863

    authors: Onal M,Elsurer C,Selimoglu N,Yilmaz M,Erdogan E,Bengi Celik J,Kal O,Onal O

    更新日期:2017-08-01 00:00:00

  • Intravenous prostacyclin mitigates inhaled nitric oxide rebound effect: A case control study.

    abstract::Although extracorporeal membrane oxygenation (ECMO) improves oxygenation, pulmonary vascular resistance may be increased due to endothelial function impairment. Inhaled nitric oxide (iNO) is increasingly used for treatment of pulmonary hypertension after surgical repair of congenital heart defects, with or without ECM...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06448.x

    authors: Hermon M,Golej J,Burda G,Marx M,Trittenwein G,Pollak A

    更新日期:1999-11-01 00:00:00