Research into the development of a wearable bioartificial kidney with a continuous hemofilter and a bioartificial tubule device using tubular epithelial cells.

Abstract:

:Current hemodialysis treatment is insufficient because of intermittent treatment and loss of tubular function. In order to overcome the loss of tubular function, a bioartificial kidney has been developed consisting of continuous hemofiltration (CHF) with 10 L/day of filtrate and a bioartificial tubule device using proximal tubular epithelial cells and hollow fiber membranes. Ten L/day of CHF enabled plasma levels of urea, creatinine, uric acid and, beta2-microglobulin in eight renal failure patients to be maintained at remarkably low levels. The concept was tested with 6 L (4 mL/min) of 10 L/day (7 mL/min) filtrate regenerated by a bioartificial tubule device and 4 L/day (3 mL/min) replaced by food and drinks. Lewis lung cancer-porcine kidney 1 (LLC-PK1) cells with a cell density of 107 cells/mL were seeded inside polysulfone hollow fiber modules four times at 1 h intervals while rotating the module 90 degrees each time, and were cultured for 48 h to form confluent monolayers. The leak rates of urea and creatinine across LLC-PK1 cell-attached polysulfone membrane modules (membrane areas: 56 cm2 and 4000 cm2) were investigated. Via conversion from 56 m2 to 1 m2 hollow fiber modules with LLC-PK1 cells for 24 h, the transport rates of H2O, glucose and Na+ were, respectively, 40, 65 and 35% of the target transported amounts from 6 L/day of filtrate. The rates are expected to approach 100% when 4-5 g/dL of albumin is added to the basal portion of the medium since the results were obtained without the addition of albumin for colloidal osmotic pressure.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Saito A

doi

10.1111/j.1525-1594.2004.07323.x

subject

Has Abstract

pub_date

2004-01-01 00:00:00

pages

58-63

issue

1

eissn

0160-564X

issn

1525-1594

pii

7323

journal_volume

28

pub_type

临床试验,杂志文章
  • Clinical evaluation of a new type of centrifugal pump.

    abstract::The major problems with existing centrifugal pumps are leakage, mechanical trauma, and thrombus formation. In consideration of these problems, a new compact centrifugal pump system was developed. The purpose of this study was to evaluate the new centrifugal pump system clinically. Ten patients underwent open heart sur...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1994.tb03403.x

    authors: Ninomiya J,Shoji T,Tanaka S,Ikeshita M,Ochi M,Yamauchi S,Yajima T,Yamauchi H,Sugimoto T,Aizawa T

    更新日期:1994-09-01 00:00:00

  • Myointimal hyperplasia: pathogenesis and implications. 1. In vitro characteristics.

    abstract::Myointimal hyperplasia (MIH) is an arterial wall smooth muscle cell (SMC) proliferative disorder. This process is responsible for a significant number of early and long-term arterial reconstructive and graft failures. Histopathologically, this process is characterized by a proliferation of SMC in the intima of traumat...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1111/j.1525-1594.1991.tb00758.x

    authors: Painter TA

    更新日期:1991-02-01 00:00:00

  • In Vitro Evaluation of an Alternative Neonatal Extracorporeal Life Support Circuit on Hemodynamic Performance and Bubble Trap.

    abstract::The objective of this study was to evaluate an alternative neonatal extracorporeal life support (ECLS) circuit with a RotaFlow centrifugal pump and Better-Bladder (BB) for hemodynamic performance and gaseous microemboli (GME) capture in a simulated neonatal ECLS system. The circuit consisted of a Maquet RotaFlow centr...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12748

    authors: Spencer SB,Wang S,Woitas K,Glass K,Kunselman AR,Ündar A

    更新日期:2017-01-01 00:00:00

  • Renal osteodystrophy in dialysis patients: diagnosis and treatment.

    abstract::This article reviews the clinical, biological, radiological, and pathological procedures and their respective indications for the practical diagnosis of the following various histological patterns of renal osteodystrophy: osteitis fibrosa due to parathyroid hormone (PTH) hypersecretion: osteomalacia or rickets due to ...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1046/j.1525-1594.1998.06198.x

    authors: Fournier A,Oprisiu R,Hottelart C,Yverneau PH,Ghazali A,Atik A,Hedri H,Said S,Sechet A,Rasolombololona M,Abighanem O,Sarraj A,El Esper N,Moriniere P,Boudailliez B,Westeel PF,Achard JM,Pruna A

    更新日期:1998-07-01 00:00:00

  • The role of diastolic pump flow in centrifugal blood pump hemodynamics.

    abstract::We tried to verify the hypothesis that increases in pump flow during diastole are matched by decreases in left ventricular (LV) output during systole. A calf (80 kg) was implanted with an implantable centrifugal blood pump (EVAHEART, SunMedical Technology Research Corp., Nagano, Japan) with left ventricle to aorta (LV...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2001.06864.x

    authors: Akimoto T,Litwak KN,Yamazaki K,Litwak P,Kihara SI,Tagusari O,Yamazaki SI,Kameneva MV,Watach MJ,Umezu M,Tomioka J,Kormos RL,Koyanagi H,Griffith BP

    更新日期:2001-09-01 00:00:00

  • Permanent cardiac pacing after cardiac operations.

    abstract::From January 1980 through December 1990, implantation of a permanent pacemaker was performed in 34 patients following open heart surgery. The patients were divided into two groups according to the clinical indications for implantation of permanent pacemakers. Group 1 (9 patients) had surgical atrioventricular block, a...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1993.tb00591.x

    authors: Otaki M

    更新日期:1993-05-01 00:00:00

  • Simple evaluation method of biocompatibility of artificial oxygenator hollow fiber.

    abstract::We made miniature modules filled with artificial oxygenator hollow fibers and conducted a simple experiment to study the effect of different membrane structures on the blood. Three types of modules were made: one filled with polyolefin, one filled with polypropylene, and a blank module. The 3 modules were connected th...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1525-1594.1996.tb00677.x

    authors: Nishida H,Shibuya M,Endo M,Koyanagi H

    更新日期:1996-12-01 00:00:00

  • Pump Speed Waveform Analysis to Detect Aortic Valve Opening in Patients on Ventricular Assist Device Support.

    abstract::As the aortic valve (AV) opens, the pump pressure head remains constant, which is reflected as a "notch/plateau" in pump pressure and flow signals. However, instantaneous flow estimation may be influenced by friction and is particularly difficult in axial pumps. Therefore, a new method to determine the duration of AV ...

    journal_title:Artificial organs

    pub_type: 杂志文章,多中心研究

    doi:10.1111/aor.12570

    authors: Hayward C,Lim CP,Schima H,Macdonald P,Moscato F,Muthiah K,Granegger M

    更新日期:2015-08-01 00:00:00

  • Heparin-coated cardiopulmonary bypass circuits in coronary bypass surgery.

    abstract::Cardiopulmonary bypass (CPB) is a nonphysiologic environment for an organism. The damage of blood components may also lead to organ dysfunction, some-times recognized as postperfusion syndrome. One possible way to diminish the risk of these complications would be to reduce the thorombogenicity and to improve the bioco...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1525-1594.1996.tb04573.x

    authors: Horimoto H,Kondo K,Asada K,Sasaki S

    更新日期:1996-08-01 00:00:00

  • Effect of temporary catheter and late referral on hospitalization and mortality during the first year of hemodialysis treatment.

    abstract::Late referral (LR) to dialysis therapy has been associated with poor outcomes in people with end-stage renal disease. This had been ascribed to the frequent use of temporary vascular catheters (TVCs) in LR patients. The effects of LR and TVC on the outcomes of an incident hemodialysis population (n = 101) were investi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2004.00016.x

    authors: Gonçalves EA,Andreoli MC,Watanabe R,Freitas MC,Pedrosa AC,Manfredi SR,Draibe SA,Cendoroglo M,Canziani ME

    更新日期:2004-11-01 00:00:00

  • A reduced priming system.

    abstract::Cardiopulmonary bypass (CPB), an integral part of valve surgery, is known to cause hemodilution, which can lead to a need for blood transfusion as well as a systemic inflammatory reaction. Our aim was to evaluate a reduced priming (RP) system for CPB with regard to clinical outcomes in patients undergoing valve surger...

    journal_title:Artificial organs

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/j.1525-1594.2006.00275.x

    authors: Sato K,Namura O,Sogawa M,Shimada K,Tosaka Y,Hayashi J

    更新日期:2006-08-01 00:00:00

  • The impact of pump speed and inlet cannulation site on left ventricular unloading with a rotary blood pump.

    abstract:BACKGROUND:Ventricular assist devices are gaining ground in the therapeutic treatment of chronic heart failure. These devices are sometimes used as a bridge to recovery by unloading the left ventricle (LV) and restoring its function. It is therefore important to preserve the heart muscle and apply less invasive implant...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2004.07374.x

    authors: Vandenberghe S,Nishida T,Segers P,Meyns B,Verdonck P

    更新日期:2004-07-01 00:00:00

  • Dispersive aortic cannulas reduce aortic wall shear stress affecting atherosclerotic plaque embolization.

    abstract::Neurologic complications during on-pump cardiovascular surgery are often induced by mobilization of atherosclerotic plaques, which is directly related to enhanced wall shear stress. In the present study, we numerically evaluated the impact of dispersive aortic cannulas on aortic blood flow characteristics, with specia...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12359

    authors: Assmann A,Gül F,Benim AC,Joos F,Akhyari P,Lichtenberg A

    更新日期:2015-03-01 00:00:00

  • Electrochemical and Electrophysiological Performance of Platinum Electrodes Within the Ninety-Nine-Electrode Stimulating Nerve Cuff.

    abstract::The trend in neural prostheses using selective nerve stimulation for electrical stimulation therapies is headed toward single-part systems having a large number of working electrodes (WEs), each of which selectively stimulate neural tissue or record neural response (NR). The present article reviews the electrochemical...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1111/aor.12625

    authors: Pečlin P,Mehle A,Karpe B,Rozman J

    更新日期:2015-10-01 00:00:00

  • Prevention of renal disease progression and renal replacement therapy in emerging countries.

    abstract::Chronic kidney disease is increasing in both developed and emerging countries with progressive encroachment on health services budgets. In spite of the lack of accurate registries, we tried to focus on the magnitude of the problem on different continents. Prevention of progression has been a remote but reachable goal....

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2006.00251.x

    authors: Hafez MH,Abdellatif DA,Elkhatib MM

    更新日期:2006-07-01 00:00:00

  • Is serum albumin a marker of nutritional status in hemodialysis patients without evidence of inflammation?

    abstract::Hypoalbuminemia, a strong predictor of morbidity and mortality in hemodialysis patients, can be a consequence of a combination of malnutrition and inflammatory reactions. The purpose of this study was to analyze serum albumin as a marker of nutritional status in maintenance hemodialysis patients with no signs of infla...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2003.07273.x

    authors: Santos NS,Draibe SA,Kamimura MA,Canziani ME,Cendoroglo M,Júnior AG,Cuppari L

    更新日期:2003-08-01 00:00:00

  • Liposome-encapsulated hemoglobin alleviates brain edema after permanent occlusion of the middle cerebral artery in rats.

    abstract::Liposome-encapsulated hemoglobin (LEH) was proven to be protective in cerebral ischemia/reperfusion injury. The present study evaluated LEH in a rat model of permanent middle cerebral artery (MCA) occlusion to clarify its effect during ischemia and reperfusion. Five minutes after thread occlusion of the MCA, rats were...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00700.x

    authors: Kawaguchi AT,Kurita D,Furuya H,Yamano M,Ogata Y,Haida M

    更新日期:2009-02-01 00:00:00

  • Balloon Dilatation for Removal of an Irretrievable Permanent Hemodialysis Catheter: The Safest Approach.

    abstract::Long-term hemodialysis catheter dwell time in the central vein predisposes to fibrin sheath development, which subsequently causes catheter malfunction or occlusion. In very rare cases, the catheter can be overgrown with fibrin and rigidly connected with the vein or heart structures. This makes its removal almost impo...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12643

    authors: Garcarek J,Gołębiowski T,Letachowicz K,Kusztal M,Szymczak M,Madziarska K,Jakuszko K,Zmonarski S,Guziński M,Weyde W,Klinger M

    更新日期:2016-05-01 00:00:00

  • Preservation of human saphenous vein against reactive oxygen species-induced oxidative stress by green tea polyphenol pretreatment.

    abstract::The injurious effects of reactive oxygen species on venous tissues and the potential protective role played by green tea polyphenol (GTPP) on human saphenous veins were investigated. Oxidative stress was induced exogenously in the vein segments, either by adding 0.8 or 1.6 M of H2O2, or by using 80 or 160 U/L of xanth...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2003.07163.x

    authors: Han DW,Suh H,Park YH,Cho BK,Hyon SH,Park JC

    更新日期:2003-12-01 00:00:00

  • The role of PI3K/Akt signaling pathway in non-physiological shear stress-induced platelet activation.

    abstract::The PI3K/Akt signaling pathway has been implicated in playing an important role in platelet activation during hemostasis and thrombosis involving platelet-matrix interaction and platelet aggregation. Its role in non-physiological shear stress (NPSS)-induced platelet activation relevant to high-shear blood contacting m...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13465

    authors: Chen Z,Li T,Kareem K,Tran D,Griffith BP,Wu ZJ

    更新日期:2019-09-01 00:00:00

  • General planning of an artificial organ center.

    abstract::There is an increasing need for research and development centers to deal with design and evaluation of organ replacement systems, the improvement of older devices, and the study of biocompatibility problems. Special attention, in this article, is focused on the determinant role of the background of the investigators i...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1989.tb01579.x

    authors: Vanholder R,Ringoir S

    更新日期:1989-12-01 00:00:00

  • Replacing cardiopulmonary bypass with extracorporeal membrane oxygenation in lung transplantation operations.

    abstract::Cardiopulmonary bypass (CPB) is required in some lung transplantation (LTx) operations. However, it increases risks of bleeding and early graft dysfunction. We report our experiences of replacing CPB with heparin-bound extracorporeal membrane oxygenation (ECMO) in LTx operations. If extracorporeal circulation was anti...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2001.025008607.x

    authors: Ko WJ,Chen YS,Lee YC

    更新日期:2001-08-01 00:00:00

  • The E4T electric powered total artificial heart (TAH).

    abstract::The E4T is a totally implantable total artificial heart (TAH) resulting from many years of research work at the Cleveland Clinic Foundation (CCF) and Nimbus, Inc. It consists of four implanted subsystems: the pumping unit, the variable volume device, the transcutaneous transformer, and the internal battery. The pumpin...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1988.tb02795.x

    authors: Smith WA,Hete BF,Kiraly RJ,Fujimoto LK,Jacobs GB,Ishikawa M,Butler K,Nosé Y

    更新日期:1988-10-01 00:00:00

  • Numerical Simulation of Nonpulsatile Left Ventricular Bypass.

    abstract::A computer simulation was carried out to investigate the influence of nonpulsatile left ventricular assistance on hemodynamics. A simulation circuit was constructed to represent the circulatory system. A source of current was added to denote the nonpulsatile blood pump. The left and right ventricles were replaced by v...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1996.tb04494.x

    authors: Mitsui N,Fukunaga S,Koura Y,Morita S,Hotei H,Sueshiro M,Sueda T,Matsuura Y

    更新日期:1996-05-01 00:00:00

  • Ferritin: a reliable indicator of iron supplementation in patients on chronic hemodialysis/hemofiltration treatment?

    abstract::Four hundred and forty-two serum ferritin determinations were performed in 144 patients on chronic intermittent hemodialysis treatment with intravenous iron substitution and/or oral iron substitution. Iron substitution should be done individually according to regular serum ferritin determinations. Intravenous iron sub...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1981.tb03980.x

    authors: Müller HA,Schneider H,Hövelborn U,Streicher E

    更新日期:1981-05-01 00:00:00

  • Multifunctional implantable nerve stimulator for cardiac assistance by skeletal muscle.

    abstract::Different methods are used, clinically and experimentally, to assist severely impaired heart function by means of skeletal muscle. The efficiency of these methods is restricted by skeletal muscle losing strength after transpositioning and during conditioning and not being sufficiently resistant to fatigue. This is mai...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06258.x

    authors: Lanmüller H,Sauermann S,Unger E,Schnetz G,Mayr W,Bijak M,Girsch W

    更新日期:1999-04-01 00:00:00

  • Internal jugular vein cannulation with two silicone rubber catheters: a new and safe temporary vascular access for hemodialysis. Thirty months' experience.

    abstract::Temporary and immediately usable vascular access is a vital need in treating uremic patients. Subclavian vein cannulation, although a major progress, has been associated with significant morbidity and mortality. Accordingly, for the last 2.5 years the authors have been developing an alternative technique consisting of...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1986.tb02587.x

    authors: Canaud B,Beraud JJ,Joyeux H,Mion C

    更新日期:1986-10-01 00:00:00

  • Effects of inhaled nitric oxide on postoperative pulmonary circulation in patients with congenital heart disease.

    abstract::We studied 22 patients with residual pulmonary hypertension or symptoms of postoperative pulmonary hypertensive crisis. They received low-dose inhalation (10 ppm) of nitric oxide (NO), a selective pulmonary vasodilator, after total correction for congenital heart anomalies. Fifteen minutes of NO inhalation improved th...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1525-1594.1997.tb00692.x

    authors: Matsui J,Yahagi N,Kumon K,Hayashi H,Watanabe Y,Haruna M,Tanigami H,Yagihara T,Takamoto S,Kamiya T

    更新日期:1997-01-01 00:00:00

  • Selective removal of circulating immune complexes from patient plasma.

    abstract::The principle of a patient-specific immunoadsorber (PsIA) is demonstrated. Studies with model systems (HSA/anti-HSA) on immobilization, stability, and leakage form the basis for the presented fast-performance liquid chromatography (FPLC) and batch experiments, which were conducted using two different protein A adsorbe...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2002.06875.x

    authors: Kunkel S,Holtz M,Grossjohann B,Schuett W,Klinkmann H,Kong D,Yamada R,Kimura H,Matic GB,Ramlow W,Boeden HF

    更新日期:2002-02-01 00:00:00

  • Bone marrow combined with dental bud cells promotes tooth regeneration in miniature pig model.

    abstract::Growth factors and morphogens secreted by bone marrow mesenchymal stem cells (BMSCs) of bone marrow fluid may promote tooth regeneration. Accordingly, a tissue engineering approach was utilized to develop an economical strategy for obtaining the growth factors and morphogens from BMSCs. Unerupted second molar tooth bu...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2010.01064.x

    authors: Kuo TF,Lin HC,Yang KC,Lin FH,Chen MH,Wu CC,Chang HH

    更新日期:2011-02-01 00:00:00