Simple evaluation method of biocompatibility of artificial oxygenator hollow fiber.

Abstract:

:We made miniature modules filled with artificial oxygenator hollow fibers and conducted a simple experiment to study the effect of different membrane structures on the blood. Three types of modules were made: one filled with polyolefin, one filled with polypropylene, and a blank module. The 3 modules were connected through 3 fine tubings to one needle so that the same blood that passed through the 3 modules could be analyzed simultaneously. Nonheparinized blood was continuously withdrawn from 6 healthy volunteers using a small pump and passed through the circuit by a single pass (10 ml/min, for 10 min). Platelet count, thrombin-antithrombin complex, and complement-3 were measured in the blood collected at 10 min from the outlet of each module. The results showed significantly better biocompatibility of polyolefin than polypropylene, which is attributable to the dense layer of the blood contact surface of polyolefin fibers. This method is useful in assessing biocompatibility of various hollow fibers in a simple and safe manner.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Nishida H,Shibuya M,Endo M,Koyanagi H

doi

10.1111/j.1525-1594.1996.tb00677.x

subject

Has Abstract

pub_date

1996-12-01 00:00:00

pages

1292-4

issue

12

eissn

0160-564X

issn

1525-1594

journal_volume

20

pub_type

临床试验,杂志文章
  • Comparison of centrifugal and roller pump hemolysis rates at low flow.

    abstract::We compared in vitro rates of hemolysis for a recently developed centrifugal pump with a conventional roller pump (10-10-00; Stöckert, Munich, Germany). Flow rates of 0.3 L/min and 1 L/min and a pressure of 200 mm Hg were chosen to simulate conditions during neonatal extracorporeal membrane oxygenation (ECMO). There w...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors: Moon YS,Ohtsubo S,Gomez MR,Moon JK,Nosé Y

    更新日期:1996-06-01 00:00:00

  • A new blood pump for cardiopulmonary bypass: the HiFlow centrifugal pump.

    abstract::Centrifugal blood pumps are considered to be generally superior to the traditionally used roller pumps in cardiopulmonary bypass. In our institute a new lightweight centrifugal sealless blood pump with a unique spherical thrust bearing and with a magnetic coupling was developed, the HiFlow. The small design makes the ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb03754.x

    authors: Göbel C,Eilers R,Reul H,Schwindke P,Jörger M,Rau G

    更新日期:1997-07-01 00:00:00

  • Circulatory loop design and components introduce artifacts impacting in vitro evaluation of ventricular assist device thrombogenicity: A call for caution.

    abstract::Mechanical circulatory support (MCS) devices continue to be hampered by thrombotic adverse events (AEs), a consequence of device-imparted supraphysiologic shear stresses, leading to shear-mediated platelet activation (SMPA). In advancing MCS devices from design to clinical use, in vitro circulatory loops containing th...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13626

    authors: Li M,Walk R,Roka-Moiia Y,Sheriff J,Bluestein D,Barth EJ,Slepian MJ

    更新日期:2020-06-01 00:00:00

  • Timing of Intra-Aortic Balloon Pump Placement Before Off-Pump Coronary Artery Bypass Grafting and Clinical Outcomes.

    abstract::We aimed to evaluate the timing of preoperative intra-aortic balloon pump (IABP) placement and outcomes in patients undergoing off-pump coronary artery bypass grafting (OPCAB). Patients with prophylactic IABP placement before OPCAB presenting between January 1, 2010 and December 31, 2013 were included. Patients were c...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13009

    authors: Liu F,Yang F,Du Z,Miao N,Zhao Y,Xu B,Hou X

    更新日期:2018-03-01 00:00:00

  • The impact of polyethylene glycol conjugation on bovine hemoglobin's circulatory half-life and renal effects in a rabbit top-loaded transfusion model.

    abstract::This study compares the effects of polyethylene glycol (PEG) modified bovine hemoglobin on vascular half-life and renal function in rabbits to those of unmodified bovine hemoglobin. Renal function was assessed by the measurement of the glomerular filtration rate, urinalysis, blood chemistries, hemoglobin (Hb) excretio...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb00250.x

    authors: Conover CD,Gilbert CW,Shum KL,Shorr RG

    更新日期:1997-08-01 00:00:00

  • Is the New Infant Jarvik 2015 Suitable for Patients

    abstract::Our aim was to study the feasibility of implanting the Infant Jarvik 2015 in patients weighing less than 8 kg. The Infant Jarvik 2015 left ventricular assist device (LVAD) was tested in a hybrid simulator of the cardiovascular system reproducing specific patients' hemodynamics for different patient weights (2-7 kg). F...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13302

    authors: Di Molfetta A,Zielinski K,Ferrari G,Kozarski M,Okrzeja P,Iacobelli R,Filippelli S,Perri G,Darowski M,Massetti M,Jarvik R,Amodeo A

    更新日期:2019-01-01 00:00:00

  • The ethics of technology introduction.

    abstract::The rapid acceleration of technology development is outpacing our ability to assess it objectively and competently. Our challenge is to develop new assessment methods that take into account the fast moving nature of technology development while still protecting the patients' and the public interest. ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.06020.x

    authors: Abele JE

    更新日期:1998-01-01 00:00:00

  • The SlideReactor--a simple hollow fiber based bioreactor suitable for light microscopy.

    abstract::Most bioartificial liver support systems are based on hollow fiber capillaries within modified dialysis cartridges or more sophisticated bioreactor constructions. Due to their design microscopic follow-up of reorganization and growth of tissue between the hollow fibers is not possible. The SlideReactor is a simple hol...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2005.29049.x

    authors: Sauer IM,Schwartlander R,Schmid J,Efimova E,Vondran FW,Kehr D,Pless G,Spinelli A,Brandenburg B,Hildt E,Neuhaus P

    更新日期:2005-03-01 00:00:00

  • Hemolytic evaluation using polyurethane microcapsule suspensions in circulatory support devices: normalized index of hemolysis comparisons of commercial centrifugal blood pumps.

    abstract::We have been developing some types of microcapsule suspensions with polyurethane membranes to evaluate the absolute hemolytic characteristics of the centrifugal blood pumps used in circulatory support devices such as artificial hearts. In order to facilitate/realize hemolysis testing on centrifugal blood pumps that ha...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2007.00503.x

    authors: Maruyama O,Yamaguchi K,Nishida M,Onoguchi T,Tsutsui T,Jikuya T,Yamane T

    更新日期:2008-02-01 00:00:00

  • A pilot study of piracetam in cuprophan hemodialysis.

    abstract::Twelve patients, 8 male and 4 female, aged from 26 to 70 years were studied. They were on hemodialysis (HD) 4 h three times weekly with cuprophan hollow fiber dialyzers (Gambro 120M) and dialysate containing 35 mEq/L of acetate. The study compares two random HD sessions on each patient. Sixty minutes prior to one rand...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1111/j.1525-1594.1989.tb01551.x

    authors: Grekas D,Alivanis P,Karamouzis M,Pyrpasopoulos M,Tourkantonis A

    更新日期:1989-10-01 00:00:00

  • Detection of suction and regurgitation of the implantable centrifugal pump based on the motor current waveform analysis and its application to optimization of pump flow.

    abstract::In this study, a detection algorithm for suction and regurgitation of the centrifugal pump during left heart bypass without relying on external flow or pressure sensors was developed and evaluated in acute studies using adult goats. The detection scheme relies on power spectral density (PSD) analysis of the motor curr...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06397.x

    authors: Yuhki A,Hatoh E,Nogawa M,Miura M,Shimazaki Y,Takatani S

    更新日期:1999-06-01 00:00:00

  • Performance of baffled bubble blood oxygenators.

    abstract::Bubble blood oxygenators equipped with baffles of various types in the oxygenating column were studied. The rate of hemolysis, the volumetric coefficient for oxygen absorption into blood, and the fractional gas holdup were found to be affected mainly by the superficial gas velocity. When compared with the conventional...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1979.tb01032.x

    authors: Ohshima N,Yoshido F

    更新日期:1979-05-01 00:00:00

  • Tissue reactions to various percutaneous materials with different surface properties and structures.

    abstract::Tissue responses to various percutaneous materials with different surface properties and structures were investigated. Dense hydroxyapatite (HA), tricalcium phosphate (TCP), glassy carbon (GC), and 2 types of porous HA were used. Cutaneous and subcutaneous tissues were tightly attached to the surface of the penetratin...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb00514.x

    authors: Shin Y,Akao M

    更新日期:1997-09-01 00:00:00

  • Development of a DNA immunoadsorbent: coupling DNA on sepharose 4FF by an efficient activation method.

    abstract::To remove anti-DNA antibodies from a patient's plasma with systemic lupus erythematosus (SLE), a DNA immunoadsorbent was developed by covalently coupling calf thymus DNA on activated Sepharose 4FF. Sepharose 4FF was activated with 5-norbornene-2,3-dicarboximido carbonochloridate (Cl-CO-ONB), which was proven to be a v...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06618.x

    authors: Kong DL,Schuett W,Boeden HF,Kunkel S,Holtz M,Matic G,Yamada R,Yu YT,Klinkmann H

    更新日期:2000-11-01 00:00:00

  • Development and hydrodynamic evaluation of a novel inflow cannula in a mechanical circulatory support system for bridge to decision.

    abstract::Recent progress in the development of implantable rotary blood pumps realized long-term mechanical circulatory support (MCS) for bridge to transplant, bridge to recovery, or a destination therapy. Meanwhile, a short-term MCS system is becoming necessary for bridge to decision. We developed a novel inflow cannula for t...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2011.01319.x

    authors: Sumikura H,Toda K,Takewa Y,Tsukiya T,Ohnuma K,Sasagawa M,Watanabe F,Ugawa J,Taenaka Y,Tatsumi E

    更新日期:2011-08-01 00:00:00

  • Plasma middle molecules in asymptomatic and "sick" uremic patients.

    abstract::By using high speed gel filtration combined with ion exchange gradient elution chromatography, the concentrations of plasma (p) middle molecules (MM) were determined in 126 samples from 90 non-dialyzed azotemic patients and in 210 pre-dialysis samples from 53 regular hemodialysis and 24 intermittent peritoneal dialysi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors: Asaba H,Bergström J,Fürst P,Johnson C,Yahiel V

    更新日期:1981-01-01 00:00:00

  • Complication profile of the Berlin Heart EXCOR biventricular support in children.

    abstract::In chronic cardiomyopathy, mechanical circulatory support (MCS) plays an increasingly important role for children as the shortage of suitable donor hearts increases waiting time on the transplant list. We report our experience with the paracorporal Berlin Heart EXCOR System (Berlin Heart AG, Berlin, Germany) used as a...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12062

    authors: Schweiger M,Schrempf J,Sereinigg M,Prenner G,Tscheliessnigg KH,Wasler A,Krumnikel J,Gamillschegg A,Knez I

    更新日期:2013-08-01 00:00:00

  • A reduced priming system.

    abstract::Cardiopulmonary bypass (CPB), an integral part of valve surgery, is known to cause hemodilution, which can lead to a need for blood transfusion as well as a systemic inflammatory reaction. Our aim was to evaluate a reduced priming (RP) system for CPB with regard to clinical outcomes in patients undergoing valve surger...

    journal_title:Artificial organs

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/j.1525-1594.2006.00275.x

    authors: Sato K,Namura O,Sogawa M,Shimada K,Tosaka Y,Hayashi J

    更新日期:2006-08-01 00:00:00

  • Heparin coating of small-caliber decellularized xenografts reduces macrophage infiltration and intimal hyperplasia.

    abstract::Small-caliber decellularized xenografts with surface heparin coating are known to reduce in vivo thrombogenicity. This study was performed to examine whether heparin coating on the small-caliber decellularized xenografts would reduce macrophage infiltration and intimal hyperplasia. In a rabbit model of bilateral carot...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00748.x

    authors: Cai WW,Gu YJ,Wang XN,Chen CZ

    更新日期:2009-06-01 00:00:00

  • Evaluation of Combined Extracorporeal Life Support and Continuous Renal Replacement Therapy on Hemodynamic Performance and Gaseous Microemboli Handling Ability in a Simulated Neonatal ECLS System.

    abstract::The objective of this study was to evaluate the hemodynamic performance and gaseous microemboli (GME) handling ability of a simulated neonatal extracorporeal life support (ECLS) circuit with an in-line continuous renal replacement therapy (CRRT) device. The circuit consisted of a Maquet RotaFlow centrifugal pump or HL...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12987

    authors: Shank KR,Profeta E,Wang S,O'Connor C,Kunselman AR,Woitas K,Myers JL,Ündar A

    更新日期:2018-04-01 00:00:00

  • Heparin-coated cardiopulmonary bypass circuits in coronary bypass surgery.

    abstract::Cardiopulmonary bypass (CPB) is a nonphysiologic environment for an organism. The damage of blood components may also lead to organ dysfunction, some-times recognized as postperfusion syndrome. One possible way to diminish the risk of these complications would be to reduce the thorombogenicity and to improve the bioco...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1525-1594.1996.tb04573.x

    authors: Horimoto H,Kondo K,Asada K,Sasaki S

    更新日期:1996-08-01 00:00:00

  • Doppler ultrasonic detection of particulate release during hemodialysis with cellulose hollow-fiber and sorbent suspension reciprocating dialyzers.

    abstract::Doppler ultrasound is a noninvasive technique for monitoring moving objects such as flowing blood while ignoring stationary objects such as shunt tubing. A Doppler system was investigated to determine its sensitivity in detecting particulate release in blood during hemodialysis. Seven hemodialysis procedures with dogs...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1984.tb04275.x

    authors: Badylak SF,Ash SR,Thornhill JA,Carr DJ

    更新日期:1984-05-01 00:00:00

  • Selective inhibition of resistance to hemopoietic allografts but not rejection to a natural killer cell sensitive tumor in transgenic mice for granulocyte colony stimulating factor.

    abstract::Transplanted allogeneic marrow grafts often fail to engraft in a lethally irradiated host. Resistance to hemopoietic allograft is a complexed phenomenon involving multiple components. To study the involvement of a hemopoietic cytokine, which was known to play a role for stem cell function, we established lines of mice...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1996.tb04563.x

    authors: Kokai Y,Kimura H,Matsuura A,Fujimoto J

    更新日期:1996-08-01 00:00:00

  • Differences in intravenous and subcutaneous application of recombinant human erythropoietin: a multicenter trial.

    abstract::The aims of this clinical study were to compare the maintenance doses for intravenous (i.v.) and subcutaneous (SC) administration of recombinant human erythropoietin (rhEPO) and to investigate whether there is any difference in the increase of the packed cellular volume (PCV) per week under i.v. and SC administration ...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章,多中心研究,随机对照试验

    doi:10.1111/j.1525-1594.1994.tb03378.x

    authors: Schaller R,Sperschneider H,Thieler H,Dutz W,Hans S,Voigt D,Marx M,Engelmann J,Schöter KH,Scigalla P

    更新日期:1994-08-01 00:00:00

  • Use of clinical guidelines for treatment of anemia among hemodialysis patients.

    abstract::Changing financial incentives have strongly influenced dosing patterns of recombinant human erythropoietin (rHuEPO) since its introduction in 1989. Although guidelines for prescribing rHuEPO exist, the extent to which they are adhered to is unknown. Using a retrospective cohort observational study design, the factors ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06495.x

    authors: Thamer M,Richard CM,Klinkmann J,Ivanovich P,Lang G,Cotter DJ

    更新日期:2000-02-01 00:00:00

  • A human lymph node in vitro--challenges and progress.

    abstract::Extracorporeal human lymphatic organs are expected to be excellent tools in the study of human molecular and cellular bases of the immunologic balance and tissue harmony. A rational approach and process to design a device and a procedure to recreate the human lymph node environment in vitro is described with emphasis ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2006.00303.x

    authors: Giese C,Demmler CD,Ammer R,Hartmann S,Lubitz A,Miller L,Müller R,Marx U

    更新日期:2006-10-01 00:00:00

  • Influence of hydration state on plasma volume changes during ultrafiltration.

    abstract::To assess the influence of hydration state on plasma volume (PV) changes during ultrafiltration, 11 clinically normhydrated patients on maintenance hemodialysis were studied intraindividually during 2 hydration states differing by 2-15% of lean body mass (LBM). Plasma volume was measured continually during a 15-min ul...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1995.tb02352.x

    authors: Wizemann V,Leibinger A,Mueller K,Nilson A

    更新日期:1995-05-01 00:00:00

  • Cerebral and lower limb near-infrared spectroscopy in adults on extracorporeal membrane oxygenation.

    abstract::Percutaneous femoral venoarterial (VA) or jugular venovenous (VV) extracorporeal membrane oxygenation (ECMO) can result in delivery of hypoxic blood to the brain, coronaries, and upper extremities. Additionally, VA-ECMO by percutaneous femoral artery cannulation may compromise perfusion to the lower limbs. Use of near...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2012.01496.x

    authors: Wong JK,Smith TN,Pitcher HT,Hirose H,Cavarocchi NC

    更新日期:2012-08-01 00:00:00

  • In Vitro Evaluation of Inflow Cannula Fixation Techniques in Left Ventricular Assist Device Surgery.

    abstract::The therapy of terminal heart failure with left ventricular assist devices has become a standard in cardiac surgery. Yet the surgical implantation technique is not standardized and differs from center to center. Complications associated with left ventricular assist device (LVAD) inflow cannula placement are thrombosis...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12735

    authors: Hanke JS,Krabatsch T,Rojas SV,Deniz E,Ismail I,Martens A,Shrestha M,Haverich A,Netuka I,Schmitto JD

    更新日期:2017-03-01 00:00:00

  • Immunologic studies of hollow-fiber dialyzer extracts.

    abstract::Testing failed to detect free isocyanates in dialyzer rinses or significant levels of immunoglobulin E antibodies to isocyanate-protein conjugates in the serum of individuals reacting during hemodialysis with dialyzers containing Cuprophan membranes. Extended immunization of rabbits with Limulus lysate-reactive materi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1984.tb04298.x

    authors: Butcher BT,Reed MA,O'Neil CE,Leech S,Pearson FC

    更新日期:1984-08-01 00:00:00