Myointimal hyperplasia: pathogenesis and implications. 1. In vitro characteristics.

Abstract:

:Myointimal hyperplasia (MIH) is an arterial wall smooth muscle cell (SMC) proliferative disorder. This process is responsible for a significant number of early and long-term arterial reconstructive and graft failures. Histopathologically, this process is characterized by a proliferation of SMC in the intima of traumatized arteries resulting in arterial and/or anastomatic stenosis with secondary thrombosis. In vitro studies of cultured SMC have allowed the evaluation of SMC response to factors suspected of being clinically associated with MIH. Principal among these is platelet derived growth factor (PDGF), which is known to be secreted by several cell types including endothelial cells (ECs) and monocytes as well as being stored and secreted by platelets. PDGF, somatomedin-C, epithelial growth factor, insulin, and other factors have been found to significantly increase SMC replication in vitro. Lipoproteins may be important substrates for SMC proliferation in contrast to heparin, which may directly inhibit SMC protein synthesis. Unlike SMCs, whose continued growth in culture is dependent on various growth factors and nutrients, ECs essentially cease to proliferate after the cells have formed a monolayer over the available surface. Extracellular matrix proteins, polypeptide mitogens, and heparin have been shown to modify EC migration and proliferation in vitro. Wounding of EC monolayers by scratching results in increased replication and migration, processes which require plasma factors that remain poorly defined. However, two general forms of EC growth factor have been isolated from many body tissues, are potent stimulators of capillary endothelial growth, and appear important both for normal EC monolayer homeostasis and for the response to injury. Cultured ECs produce mitogens for SMC. Production of the principal mitogen, PDGF, is significantly increased in sparse versus confluent cell cultures as well as by toxic agents such as endotoxin and phorbol esters. Acetyl low density lipoprotein as well as omega-3 fatty acids may significantly and selectively inhibit EC PDGF production, a finding with potentially profound implications for the clinical control of MIH in vivo.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Painter TA

doi

10.1111/j.1525-1594.1991.tb00758.x

subject

Has Abstract

pub_date

1991-02-01 00:00:00

pages

42-55

issue

1

eissn

0160-564X

issn

1525-1594

journal_volume

15

pub_type

杂志文章,评审
  • Circulatory loop design and components introduce artifacts impacting in vitro evaluation of ventricular assist device thrombogenicity: A call for caution.

    abstract::Mechanical circulatory support (MCS) devices continue to be hampered by thrombotic adverse events (AEs), a consequence of device-imparted supraphysiologic shear stresses, leading to shear-mediated platelet activation (SMPA). In advancing MCS devices from design to clinical use, in vitro circulatory loops containing th...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13626

    authors: Li M,Walk R,Roka-Moiia Y,Sheriff J,Bluestein D,Barth EJ,Slepian MJ

    更新日期:2020-06-01 00:00:00

  • Coronary artery bypass grafting for dialysis patients: usefulness of multiarterial bypass.

    abstract::This study assessed the efficacy of multiarterial bypass in coronary artery bypass grafting (CABG) in dialysis patients. Eighty dialysis patients who underwent CABG were divided into 2 groups. Group A consisted of 38 patients in whom the left internal thoracic artery and additional saphenous vein graft (SVG) had been ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors: Nakayama Y,Sakata R,Ura M

    更新日期:2001-04-01 00:00:00

  • Transcutaneous monitoring of blood gas tensions in patients on intermittent peritoneal dialysis.

    abstract::A relative contraindication to intermittent peritoneal dialysis (IPD) is chronic lung disease. To evaluate whether the instillation of 2 L of fluid into the peritoneal cavity affects respiratory function, five IPD patients were studied in the supine position during the first 4 h of a routine IPD session. Blood gas ten...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1988.tb02768.x

    authors: Korzets Z,Pomeranz A,Shachor Y,Bernheim J

    更新日期:1988-06-01 00:00:00

  • Pseudoendothelium formation in expanded polytetrafluoroethylene grafts implanted in the inferior vena cava of normal and defibrinogenated dogs.

    abstract::The outgrowth of endothelial cells in an expanded polytetrafluoroethylene graft implanted in the canine inferior vena cava was studied by scanning electron microscopy. The adjacent endothelial cells of the vena cava started to invade the anastomotic area three days after the implantation and reached approximately the ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1981.tb04020.x

    authors: Ishimaru S,Berglin E,Hansson HA,Teger-Nilsson AC,William-Olsson G

    更新日期:1981-11-01 00:00:00

  • Hemoperfusion and DNA synthesis in the rat liver. Part I: the effect of hemoperfusion on the rate of DNA synthesis.

    abstract::An investigation has been made into whether charcoal hemoperfusion stimulates a hyperplastic response in the liver of the normal rat. Animals underwent hemoperfusion over Norit RBX1 (Strathclyde, Glasgow, U.K.) charcoal granules using a technique which allowed perfusion in the unrestrained and conscious state. Control...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1982.tb04080.x

    authors: Ryan CJ,Courtney JM,Wood CB,Blumgart LH

    更新日期:1982-05-01 00:00:00

  • Effects of atrial arrhytmias on the regurgitation of a monoleaflet prosthetic heart valve.

    abstract::Many patients who receive a prosthetic heart valve also have or acquire cardiac arrhythmias. However, most in vitro studies of prosthetic valves examine them under normal rhythms. In this study, a monoleaflet prosthetic heart valve was tested in vitro under conditions that simulated normal sinus rhythm, first degree a...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2005.29101.x

    authors: Zapanta CM

    更新日期:2005-08-01 00:00:00

  • Feasibility of extracorporeal on-line large-scale plasma adsorptions on protein A-sepharose columns in cancer patients.

    abstract::The feasibility of extracorporeal adsorption of 1.5-3 L plasma on protein A-Sepharose was investigated in six patients with advanced cancer. Anticoagulation with heparin was associated with respiratory distress syndrome in two patients, most likely caused by complement activation as indicated by a transient leukopenia...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1984.tb04247.x

    authors: Wallmark A,Grubb A,Freiburghaus C,Flodgren P,Husberg B,Lindholm T,Lindström C,Thysell H,Sjögren HO

    更新日期:1984-02-01 00:00:00

  • In vivo characterization of a decellularized dermis-polymer complex for use in percutaneous devices.

    abstract::To develop a method for making percutaneous devices that have high biocompatibility and do not induce downgrowth of epidermal cells, we prepared a partial decellularized dermis (DD)/poly(methyl methacrylate) (PMMA) complex (PDPC) with a PMMA rod firmly stabilized inside. The porcine decellularized tissue was chosen be...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12330

    authors: Nam K,Matsushima R,Kimura T,Fujisato T,Kishida A

    更新日期:2014-12-01 00:00:00

  • Effect of hemodialysis on T lymphocyte subsets, con-A-activated suppressor cell activity, and interleukin-2 receptor expression on lymphocytes in chronic uremic patients.

    abstract::Effect of hemodialysis (HD) on some indices of immune response was studied in nine chronic uremics. Total lymphocyte, OKT4+, and OKT8+ cell numbers significantly decreased during the first 20 min of HD, and they were decreased till the third hour of the procedure, whereas the OKT4+/OKT8+ cell number ratio did not chan...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1989.tb02861.x

    authors: Tchórzewski H,Luciak M,Trznadel K,Majewska E,Pokoca L

    更新日期:1989-06-01 00:00:00

  • Evaluation of Combined Extracorporeal Life Support and Continuous Renal Replacement Therapy on Hemodynamic Performance and Gaseous Microemboli Handling Ability in a Simulated Neonatal ECLS System.

    abstract::The objective of this study was to evaluate the hemodynamic performance and gaseous microemboli (GME) handling ability of a simulated neonatal extracorporeal life support (ECLS) circuit with an in-line continuous renal replacement therapy (CRRT) device. The circuit consisted of a Maquet RotaFlow centrifugal pump or HL...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12987

    authors: Shank KR,Profeta E,Wang S,O'Connor C,Kunselman AR,Woitas K,Myers JL,Ündar A

    更新日期:2018-04-01 00:00:00

  • A newly designed adapter for testing an ex vivo mitral valve apparatus.

    abstract::Few instruments are currently available to test mitral valve function in an ex vivo state due to the technical difficulties involved. To investigate the native ex vivo mitral valve or prosthetic mitral valve with chordae, we developed a mitral valve adapter with an annulus suturing portion and 2 papillary muscle sutur...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06293.x

    authors: Katoh T,Ikeda N,Nishi K,Gohra H,Hamano K,Noda H,Fujimura Y,Esato K

    更新日期:1999-10-01 00:00:00

  • Development of a DNA immunoadsorbent: coupling DNA on sepharose 4FF by an efficient activation method.

    abstract::To remove anti-DNA antibodies from a patient's plasma with systemic lupus erythematosus (SLE), a DNA immunoadsorbent was developed by covalently coupling calf thymus DNA on activated Sepharose 4FF. Sepharose 4FF was activated with 5-norbornene-2,3-dicarboximido carbonochloridate (Cl-CO-ONB), which was proven to be a v...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06618.x

    authors: Kong DL,Schuett W,Boeden HF,Kunkel S,Holtz M,Matic G,Yamada R,Yu YT,Klinkmann H

    更新日期:2000-11-01 00:00:00

  • Usability and safety of ventricular assist devices: human factors and design aspects.

    abstract::The purpose of this study was the investigation of the usability and ergonomics of ventricular assist devices (VADs) in everyday usage. Patients with four different VAD types were observed. After implantation, instruction, and discharge from the hospital, the patients returned on a regular basis to the outpatient clin...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00844.x

    authors: Geidl L,Zrunek P,Deckert Z,Zimpfer D,Sandner S,Wieselthaler G,Schima H

    更新日期:2009-09-01 00:00:00

  • Ferritin: a reliable indicator of iron supplementation in patients on chronic hemodialysis/hemofiltration treatment?

    abstract::Four hundred and forty-two serum ferritin determinations were performed in 144 patients on chronic intermittent hemodialysis treatment with intravenous iron substitution and/or oral iron substitution. Iron substitution should be done individually according to regular serum ferritin determinations. Intravenous iron sub...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1981.tb03980.x

    authors: Müller HA,Schneider H,Hövelborn U,Streicher E

    更新日期:1981-05-01 00:00:00

  • Donkey pericardium compares favorably with commercial xenopericardia used in the manufacture of transcatheter heart valves.

    abstract::Transcatheter aortic valve implantation (TAVI) has gained considerable acceptance in the past decade due to its lower risks than conventional open-heart surgery. However, the deformation and delamination of the leaflets during the crimping procedure have raised questions about the durability and long-term serviceabili...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13503

    authors: Mao J,Rassoli A,Tong Y,Rouse EN,Le-Bel G,How D,Germain L,Fatouraee N,Zhang Z,Reed RR,Guidoin R

    更新日期:2019-10-01 00:00:00

  • The accurate control of ultrafiltration.

    abstract::An apparatus has been contructed to regulate ultrafiltration accurately during dialysis. The principle of the apparatus is that, per unit of time, exactly the same amount of dialysate is introduced into the dialyzer as is discharged from it. The apparatus consists of two isovolumetric pumps connected in line. The four...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1978.tb03442.x

    authors: Flendrig JG,Carpay WM,Dekkers WT

    更新日期:1978-05-01 00:00:00

  • An advanced mock circulation loop for in vitro cardiovascular device evaluation.

    abstract::Controlled and repeatable in vitro evaluation of cardiovascular devices using a mock circulation loop (MCL) is essential prior to in vivo or clinical trials. MCLs often consist of only a systemic circulation with no autoregulatory responses and limited validation. This study aimed to develop, and validate against huma...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13636

    authors: Gregory SD,Pauls JP,Wu EL,Stephens A,Steinseifer U,Tansley G,Fraser JF

    更新日期:2020-06-01 00:00:00

  • Intravascular micropump for augmented liver perfusion: first in vivo experience.

    abstract::The aim of this study was to assess the in vivo performance of a new microaxial rotary blood pump developed for long-term intraportal implantation. The pump, measuring 7 mm in diameter, has a single stage impeller and is powered by a microelectric motor. The pump was implanted into the portal vein in 13 large white pi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2001.06772.x

    authors: Havlík R,Kerkhoffs W,Jiao LR,Schumacher O,Reul H,Habib N

    更新日期:2001-05-01 00:00:00

  • Ultrasonic pulsed Doppler blood flowmeter for use in extracorporeal circulation.

    abstract::In cardiac surgeries, it is frequently necessary to make the external blood circulation and oxygenation artificially. This procedure is called extracorporeal circulation (EC) or heart-lung bypass. During EC, one of the most important parameters, which demands continuous monitoring, is the blood flow. In many cases, th...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06532.x

    authors: Dantas RG,Costa ET

    更新日期:2000-03-01 00:00:00

  • Initial experience with Impella RP in a quaternary transplant center.

    abstract::Right ventricular failure is one of the most common complications encountered after left ventricular assist device implantation and heart transplantation. It has been reported to have an incidence up to 30%. It increases morbidity and short-term mortality. Impella RP is a small pump that can provide up to 4L/min of fl...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13610

    authors: Monteagudo-Vela M,Simon A,Panoulas V

    更新日期:2020-05-01 00:00:00

  • Controlled delivery of low-dose bone morphogenetic protein-2 using heparin-conjugated fibrin in the posterolateral lumbar fusion of rabbits.

    abstract::The heparin-conjugated fibrin (HCF) system has been developed to deliver bone morphogenetic proteins (BMPs) for a long-term period and thus enhance bone regeneration. In the present study, we tested the effectiveness of the delivery system for spinal fusion with a very low dose of BMP-2. A total of 15 rabbits underwen...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2012.01578.x

    authors: Koo KH,Lee JM,Ahn JM,Kim BS,La WG,Kim CS,Im GI

    更新日期:2013-05-01 00:00:00

  • Development of integrated electronics unit for drive and control of undulation pump-left ventricular assist device.

    abstract::In this study, we have developed an implantable electronics unit (IEU) for driving an undulation pump-left ventricular assist device (UP-LVAD). The IEU consists of a pump driver, three series-connected lithium ion batteries (1800 mAh), a charger, and a transcutaneous information transmission system. These electronic s...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2006.00233.x

    authors: Okamoto E,Makino T,Inoue Y,Tanaka S,Yasuda T,Nakamura M,Saito I,Abe Y,Chinzei T,Isoyama T,Mochiizuki S,Imachi K,Mitamura Y

    更新日期:2006-05-01 00:00:00

  • Effects of customized bicarbonate buffered solutions for continuous renal replacement therapies on polymorphonuclear leukocytes function and viability.

    abstract::It has previously been shown that the mixture of bicarbonate and calcium in the solutions used for continuous renal replacement therapy led to crystallization and significant changes in calcium concentration and pH. The aim of this study was to investigate the impact of bicarbonate/calcium and lactate/calcium solution...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2004.07284.x

    authors: Maccariello E,Dalboni MA,Draibe SA,Rocha E,Pavão dos Santos OF,Santos B,Cendoroglo M

    更新日期:2004-06-01 00:00:00

  • Re-endothelialization of non-detergent decellularized porcine vessels.

    abstract::Tissue engineering utilizes an interdisciplinary approach to generate constructs for the treatment and repair of diseased organs. Generation of small vessels as vascular grafts or as envisioned central vessel for vascularized constructs is still a challenge. Here, the decellularization of porcine vessels by a non-dete...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13836

    authors: Eyre K,Samper E,Haverich A,Hilfiker A,Andrée B

    更新日期:2020-10-01 00:00:00

  • Is the New Infant Jarvik 2015 Suitable for Patients

    abstract::Our aim was to study the feasibility of implanting the Infant Jarvik 2015 in patients weighing less than 8 kg. The Infant Jarvik 2015 left ventricular assist device (LVAD) was tested in a hybrid simulator of the cardiovascular system reproducing specific patients' hemodynamics for different patient weights (2-7 kg). F...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13302

    authors: Di Molfetta A,Zielinski K,Ferrari G,Kozarski M,Okrzeja P,Iacobelli R,Filippelli S,Perri G,Darowski M,Massetti M,Jarvik R,Amodeo A

    更新日期:2019-01-01 00:00:00

  • Effect of filtration leukocytapheresis therapy: modulation of white blood cell enzyme activities in patients with rheumatoid arthritis.

    abstract::We treated 12 patients with rheumatoid arthritis by filtration leukocytapheresis (FLCP) and evaluated its effect on leukocyte enzyme activities. We calculated the number of leukocytes removed and assessed the clinical response. We also evaluated the cellular enzyme activities of elastase and dipeptidylpeptidase IV (DP...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2002.06834.x

    authors: Yamasaki S,Ueki Y,Nakamura H,Yano M,Matsumoto K,Miyake S,Tominaga T,Tominaga M,Eguchi K

    更新日期:2002-04-01 00:00:00

  • Multifunctional implantable nerve stimulator for cardiac assistance by skeletal muscle.

    abstract::Different methods are used, clinically and experimentally, to assist severely impaired heart function by means of skeletal muscle. The efficiency of these methods is restricted by skeletal muscle losing strength after transpositioning and during conditioning and not being sufficiently resistant to fatigue. This is mai...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06258.x

    authors: Lanmüller H,Sauermann S,Unger E,Schnetz G,Mayr W,Bijak M,Girsch W

    更新日期:1999-04-01 00:00:00

  • Noninvasive average flow estimation for an implantable rotary blood pump: a new algorithm incorporating the role of blood viscosity.

    abstract::The effect of blood hematocrit (HCT) on a noninvasive flow estimation algorithm was examined in a centrifugal implantable rotary blood pump (iRBP) used for ventricular assistance. An average flow estimator, based on three parameters, input electrical power, pump speed, and HCT, was developed. Data were collected in a ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2007.00339.x

    authors: Malagutti N,Karantonis DM,Cloherty SL,Ayre PJ,Mason DG,Salamonsen RF,Lovell NH

    更新日期:2007-01-01 00:00:00

  • Nitric oxide added to the sweep gas of the oxygenator during cardiopulmonary bypass in infants: A pilot randomized controlled trial.

    abstract::Our objective was to assess the effect of nitric oxide added to the sweep gas of the oxygenator during cardiopulmonary bypass (CPB) in infants on platelet count, platelet function, clinical outcomes, and safety. A randomized, double-blinded, placebo-controlled clinical trial in infants less than a year of age undergoi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13788

    authors: Niebler RA,Chiang-Ching H,Daley K,Janecke R,Jobe SM,Mitchell ME,Varner C,Woods K,Scott JP

    更新日期:2020-08-01 00:00:00

  • Effects of uremic toxin p-cresol on proliferation, apoptosis, differentiation, and glucose uptake in 3T3-L1 cells.

    abstract::Malnutrition is a common feature seen in chronic dialysis patients, and the survival rate of obese patients receiving such treatment is higher than that of lean patients. Irrespective of obesity or diabetes, dialysis patients commonly have insulin resistance, and the leading cause of death is cardiovascular (CV) disea...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12252

    authors: Tanaka S,Yano S,Sheikh AM,Nagai A,Sugimoto T

    更新日期:2014-07-01 00:00:00