Permanent cardiac pacing after cardiac operations.

Abstract:

:From January 1980 through December 1990, implantation of a permanent pacemaker was performed in 34 patients following open heart surgery. The patients were divided into two groups according to the clinical indications for implantation of permanent pacemakers. Group 1 (9 patients) had surgical atrioventricular block, and Group 2 (25 patients) had sick sinus syndrome. Tricuspid valve surgery was involved in 67% of Group 1 and 64% of Group 2. Adams-Stokes syncopal attack was the prime indication for permanent pacing in 100% of Group 1 and in 72% of Group 2. There were 2 operative deaths in Group 1, and no deaths in Group 2 (22% in Group 1 vs. 0% in Group 2, p < 0.005). Causes of the deaths were not related to the pacemaker implantation but to congestive heart failure following surgery. Among 32 survivors, there were 2 late deaths in Group 1, and 4 deaths in Group 2 (25% in Group 1 vs. 16% in Group 2, p < 0.05). The overall actuarial survival rate at 10 years was 82.1 +/- 2.8%. However, the actuarial survival rate of patients in Group 1 is 70.2 +/- 4.1%, which is statistically less than 85.4 +/- 2.2% in Group 2 (p < 0.01). As judged by these results, patients in Group 1 should be followed on a regular out-patient basis even if they are asymptomatic and there is no evidence of pacemaker failure.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Otaki M

doi

10.1111/j.1525-1594.1993.tb00591.x

subject

Has Abstract

pub_date

1993-05-01 00:00:00

pages

346-9

issue

5

eissn

0160-564X

issn

1525-1594

journal_volume

17

pub_type

杂志文章
  • Cytotoxicity of two novel formulations of calcium phosphate cements: a comparative in vitro study.

    abstract::The purpose was to evaluate the cytotoxicity of two novel formulations (alpha and beta) of calcium phosphate cements. Positive control, represented by a commercial hydroxyapatite cement, and negative control were included for comparative purposes. A continuous lineage of fibroblastic cells was used, and the effect of ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2005.29022.x

    authors: Rossa C Jr,Marcantonio E Jr,Santos LA,Boschi AO,Raddi MS

    更新日期:2005-02-01 00:00:00

  • Differences in intravenous and subcutaneous application of recombinant human erythropoietin: a multicenter trial.

    abstract::The aims of this clinical study were to compare the maintenance doses for intravenous (i.v.) and subcutaneous (SC) administration of recombinant human erythropoietin (rhEPO) and to investigate whether there is any difference in the increase of the packed cellular volume (PCV) per week under i.v. and SC administration ...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章,多中心研究,随机对照试验

    doi:10.1111/j.1525-1594.1994.tb03378.x

    authors: Schaller R,Sperschneider H,Thieler H,Dutz W,Hans S,Voigt D,Marx M,Engelmann J,Schöter KH,Scigalla P

    更新日期:1994-08-01 00:00:00

  • Utilization of activated carbon hemoperfusion to assist recovery of ischemically damaged canine liver allografts.

    abstract::The sensitivity of liver allografts to even minimal periods of ischemia currently limits the duration of hepatic preservation prior to liver transplantation. This study evaluates the role of activated carbon hemoperfusion (ACH) for assisting the recovery of canine livers ischemically damaged by a 20-min occlusion of t...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1985.tb04386.x

    authors: Toledo-Pereyra LH

    更新日期:1985-08-01 00:00:00

  • Fluctuations of the hemodynamic derivatives during left ventricular assistance using oscillated blood flow.

    abstract::To analyze the autonomic nervous system during left heart bypass with a vibrating flow pump (VFP), fluctuations in hemodynamic derivatives were evaluated by the spectral analysis method using fast fourier transform methodology. After the left pleural cavity was opened through the fourth intercostal space under general...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors: Yambe T,Kobayashi S,Nanka S,Naganuma S,Nitta S,Matsuki H,Abe K,Yoshizawa M,Fukuju T,Tabayashi K,Takeda H,Hashimoto H

    更新日期:1996-06-01 00:00:00

  • Effect of Continuous-Flow Mechanical Circulatory Support on Microvasculature Remodeling in the Failing Heart.

    abstract::Left ventricle (LV) unloading caused by a left ventricular assist device (LVAD) has been shown to enhance reverse LV remodeling in end-stage cardiomyopathy. Several reports consistently suggest that a pulsatile-flow LVAD has more profound effects compared to continuous-flow LVAD, though the responsible mechanisms are ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13348

    authors: Saito T,Miyagawa S,Toda K,Yoshikawa Y,Fukushima S,Saito S,Yoshioka D,Sakata Y,Daimon T,Sawa Y

    更新日期:2019-04-01 00:00:00

  • Changes in Spirometry After Left Ventricular Assist Device Implantation.

    abstract::Left ventricular assist devices (LVADs) are increasingly being used as life-saving therapy in patients with end-stage heart failure. The changes in spirometry following LVAD implantation and subsequent unloading of the left ventricle and pulmonary circulation are unknown. In this study, we explored long-term changes i...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12507

    authors: Mohamedali B,Bhat G,Yost G,Tatooles A

    更新日期:2015-12-01 00:00:00

  • Anionic collagen: polymer composites with improved dielectric and rheological properties.

    abstract::This work describes the preparation and characterization of anionic collagen composites with rhamsan and vinylidene fluoride-trifluorethylene with improved rheological and dielectric properties without loss of collagen secondary structure with an interaction occurring between both macromolecules of the composites. On ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.06109.x

    authors: Goissis G,Piccirili L,Goes JC,de Guzzi Plepis AM,Das-Gupta DK

    更新日期:1998-03-01 00:00:00

  • Hypertension and end-stage renal disease in the developing world.

    abstract::Hypertension is an important primary etiology of end-stage renal disease as well as a major factor responsible for progression of renal disease due to other causes. Multiple genetic and environmental factors are responsible for the variable prevalence of hypertension in various parts of the world. Although the frequen...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2002.07067.x

    authors: El-Khashab O

    更新日期:2002-09-01 00:00:00

  • Computational flow optimization of rotary blood pump components.

    abstract::In an effort to improve and automate the fluid dynamic design of rotary blood pumps, a coupled computational fluid dynamics (CFD) shape optimization methodology has been developed and implemented. This program couples a finite element flow simulation with a gradient-based optimization routine to modify automatically t...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1995.tb02389.x

    authors: Antaki JF,Ghattas O,Burgreen GW,He B

    更新日期:1995-07-01 00:00:00

  • Risk factor forlung infection in recipients after liver transplantation:a meta-analysis.

    abstract:OBJECTIVE:Lung infection (LI) often occurs in patients with liver transplantation (LT). This meta-analysis was conducted to determine the risk factors associated with LI after LT. METHODS:We retrieved relevant research published as of February 2020 from 8 electronic databases. The studieswere reviewed against the incl...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13826

    authors: Zhang J,He Q,Du L,Ji R,Yuan L,Zhang H,Yuan X,Shen L,Li Y

    更新日期:2020-09-26 00:00:00

  • Anticoagulation with fondaparinux for hemodiafiltration in patients with heparin-induced thrombocytopenia: dose-finding study and safety evaluation.

    abstract::The optimal anticoagulation regimen for hemodialysis (HD) in patients with heparin-induced thrombocytopenia (HIT) has not been defined. Hemodiafiltration (HDF) adds a large convective component to HD, thereby changing the pharmacokinetics of most anticoagulants. Data on coagulation regimens for HDF are scant. We there...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12002

    authors: Mahieu E,Claes K,Jacquemin M,Evenepoel P,Op De Beek K,Bogaert AM,Kuypers D,Verhamme P,Meijers B

    更新日期:2013-05-01 00:00:00

  • Charged compounds of the glomerular filter and their role in normal and disordered permselectivity.

    abstract::Infusion into rats of the polycation hexadimethrine (HDM) leads to onset of massive proteinuria, which recovers when the infusion is stopped. Several lines of evidence indicate that the proteinuria results from binding of HDM to polyanions of the glomerular filter, with neutralization of shielding of their charges. To...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1987.tb02712.x

    authors: Hunsicker LG,Bertolatus JA

    更新日期:1987-12-01 00:00:00

  • Evaluation of perfusion modes on vital organ recovery and thyroid hormone homeostasis in pediatric patients undergoing cardiopulmonary bypass.

    abstract::The objectives of this study were: (i) to evaluate the effects of perfusion modes (pulsatile vs. nonpulsatile) on vital organs recovery and (ii) to investigate the influences of two different perfusion modes on the homeostasis of thyroid hormones in pediatric patients undergoing cardiopulmonary bypass (CPB) procedures...

    journal_title:Artificial organs

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/j.1525-1594.2010.01159.x

    authors: Akçevin A,Alkan-Bozkaya T,Qiu F,Undar A

    更新日期:2010-11-01 00:00:00

  • Adsorption of microorganism components by lixelle beads.

    abstract::We reported previously that Lixelle, which was used for beta-2 microglobulin (BMG) adsorption columns, could adsorb not only BMG but also inflammatory cytokines. We then were interested in the application of Lixelle to patients with systemic inflammatory response syndrome (SIRS) and tried to find out its ability to ad...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06502-2.x

    authors: Tsuchida K,Takemoto Y,Nakatani T,Nakamura T,Sugimura K,Yamamoto K

    更新日期:2000-07-01 00:00:00

  • The BiVACOR rotary biventricular assist device: concept and in vitro investigation.

    abstract::The BiVACOR is a novel rotary Biventricular Assist Device (BiVAD) undergoing development to treat global end-stage heart failure. The design includes left and right vanes positioned on a shared rotating hub to form a double-sided magnetically and hydrodynamically suspended centrifugal impeller. The performance of the ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00633.x

    authors: Timms D,Fraser J,Hayne M,Dunning J,McNeil K,Pearcy M

    更新日期:2008-10-01 00:00:00

  • Pulsatile in vitro simulation of the pediatric univentricular circulation for evaluation of cardiopulmonary assist scenarios.

    abstract::The characteristic depressed hemodynamic state and gradually declining circulatory function in Fontan patients necessitates alternative postoperative management strategies incorporating a system level approach. In this study, the single-ventricle Fontan circulation is modeled by constructing a practical in vitro bench...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00951.x

    authors: Dur O,Lara M,Arnold D,Vandenberghe S,Keller BB,DeGroff C,Pekkan K

    更新日期:2009-11-01 00:00:00

  • Lixelle adsorbent to remove inflammatory cytokines.

    abstract::A beta2-microglobulin (beta2M) selective adsorbent (Lixelle) for direct hemoperfusion has been used for the treatment of hemodialysis patients with the long-term complication of dialysis related amyloidosis (DRA), but there is no significant correlation between the serum level of beta2M and the occurrence of DRA. Infl...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.06179.x

    authors: Tsuchida K,Takemoto Y,Nakamura T,Fu O,Okada C,Yamagami S,Kishimoto T

    更新日期:1998-12-01 00:00:00

  • Reciprocal influences between ambulatorial peritoneal dialysis and pulmonary function.

    abstract::The aim of this study was to verify if dialysis solution volumes used in patients on continuous ambulatory peritoneal dialysis (CAPD) interfere with pulmonary function and if the pulmonary volumes interfere with the lymphatic absorption of the peritoneal cavity. We submitted 10 CAPD patients with a mean age of 48 +/- ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2001.06904.x

    authors: Marmanillo CG,Pecoits-Filho RF,Romão JE Jr,Kakehashi ET,Sabbaga E,Marcondes M,Abensur H

    更新日期:2001-11-01 00:00:00

  • Intravascular micropump for augmented liver perfusion: first in vivo experience.

    abstract::The aim of this study was to assess the in vivo performance of a new microaxial rotary blood pump developed for long-term intraportal implantation. The pump, measuring 7 mm in diameter, has a single stage impeller and is powered by a microelectric motor. The pump was implanted into the portal vein in 13 large white pi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2001.06772.x

    authors: Havlík R,Kerkhoffs W,Jiao LR,Schumacher O,Reul H,Habib N

    更新日期:2001-05-01 00:00:00

  • Extracorporeal Life Support in Out-of-Hospital Refractory Cardiac Arrest.

    abstract::Out-of-Hospital refractory Cardiac Arrest (OHrCA) has a mortality rate between 90 and 95%. Since 2009, French medical academic societies have recommended the use of extracorporeal life support (ECLS) for OHrCA. According to these guidelines, patients were eligible for ECLS support if vital signs were still present dur...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12655

    authors: Rousse N,Robin E,Juthier F,Hysi I,Banfi C,Al Ibrahim M,Coadou H,Goldstein P,Wiel E,Vincentelli A

    更新日期:2016-09-01 00:00:00

  • Intraarterial perfusion of the hindlimb with pyridoxalated hemoglobin polyoxyethylene conjugate solution in anesthetized dogs.

    abstract::To evaluate the potential clinical usefulness of a modified hemoglobin, pyridoxalated hemoglobin polyoxyethylene conjugate (PHP), the hindlimb vascular bed was perfused with PHP solution while monitoring tissue oxygen tension (PtO2) in anesthetized dogs. The hindlimb region was perfused through the external iliac arte...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1995.tb02371.x

    authors: Kida Y,Yamakawa T,Iwasaki S,Furusho N,Kadowaki Y,Iwata S,Iwashita Y,Nishi K

    更新日期:1995-06-01 00:00:00

  • Unsteady fluid dynamics of several mechanical prosthetic heart valves using a two component laser Doppler anemometer system.

    abstract::Five typical mechanical heart valves (Starr-Edwards, Björk-Shiley convexo-concave (c-c), Björk-Shiley monostrut, Bicer-Val, and St. Jude Medical) were tested in the mitral position under the pulsatile flow condition. The test program included measurements of velocity and turbulent stresses at 5 downstream locations. T...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb00451.x

    authors: Akutsu T,Modi VJ

    更新日期:1997-10-01 00:00:00

  • Remote monitoring of left ventricular assist device parameters after HeartAssist-5 implantation.

    abstract::Although several left ventricular assist devices (LVADs) have been used widely, remote monitoring of LVAD parameters has been available only recently. We present our remote monitoring experience with an axial-flow LVAD (HeartAssist-5, MicroMed Cardiovascular, Inc., Houston, TX, USA). Five consecutive patients who were...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12144

    authors: Pektok E,Demirozu ZT,Arat N,Yildiz O,Oklu E,Eker D,Ece F,Ciftci C,Yazicioglu N,Bayindir O,Kucukaksu DS

    更新日期:2013-09-01 00:00:00

  • Timing of Intra-Aortic Balloon Pump Placement Before Off-Pump Coronary Artery Bypass Grafting and Clinical Outcomes.

    abstract::We aimed to evaluate the timing of preoperative intra-aortic balloon pump (IABP) placement and outcomes in patients undergoing off-pump coronary artery bypass grafting (OPCAB). Patients with prophylactic IABP placement before OPCAB presenting between January 1, 2010 and December 31, 2013 were included. Patients were c...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13009

    authors: Liu F,Yang F,Du Z,Miao N,Zhao Y,Xu B,Hou X

    更新日期:2018-03-01 00:00:00

  • Use of clinical guidelines for treatment of anemia among hemodialysis patients.

    abstract::Changing financial incentives have strongly influenced dosing patterns of recombinant human erythropoietin (rHuEPO) since its introduction in 1989. Although guidelines for prescribing rHuEPO exist, the extent to which they are adhered to is unknown. Using a retrospective cohort observational study design, the factors ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06495.x

    authors: Thamer M,Richard CM,Klinkmann J,Ivanovich P,Lang G,Cotter DJ

    更新日期:2000-02-01 00:00:00

  • Pulse push/pull hemodialysis: in vitro study on new dialysis modality with higher convective efficiency.

    abstract::Midsize molecule retention is related with renal-failure-associated mortality. Here, the authors describe a new dialysis modality, pulse push/pull hemodialysis (PPPHD), which increases convective clearance. Blood and dialysate are circulated by a pulsatile pump, but with pulsatile flow patterns that are 180 degrees ou...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00561.x

    authors: Lee K,Lee SR,Mun CH,Min BG

    更新日期:2008-05-01 00:00:00

  • Elective decompression of the left ventricle in pediatric patients may reduce the duration of venoarterial extracorporeal membrane oxygenation.

    abstract::We aimed to determine the effect of elective left heart decompression at the time of initiation of central venoarterial extracorporeal membrane oxygenation (VA ECMO) on VA ECMO duration and clinical outcomes in children in a single tertiary ECMO referral center with a large pediatric population from a national referra...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12390

    authors: Hacking DF,Best D,d'Udekem Y,Brizard CP,Konstantinov IE,Millar J,Butt W

    更新日期:2015-04-01 00:00:00

  • Double catheterization of the internal jugular vein for hemodialysis: indications, techniques, and clinical results.

    abstract::Central vascular catheters are used to access the central vascular system in both acute and chronic uremic patients undergoing hemodialysis. Among different approaches, the internal jugular vein seems to have less adverse effects. We describe our long-term experience with a two-catheter system. Percutaneous jugular ve...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1994.tb02200.x

    authors: Tesio F,De Baz H,Panarello G,Calianno G,Quaia P,Raimondi A,Schinella D

    更新日期:1994-04-01 00:00:00

  • Antithrombin replacement during extracorporeal membrane oxygenation.

    abstract::Heparin remains the predominant anticoagulant during extracorporeal membrane oxygenation (ECMO). Heparin acts by potentiating the anticoagulant effect of antithrombin (ATIII). Acquired ATIII deficiency, common in pediatric patients requiring ECMO, may result in ineffective anticoagulation with heparin. ATIII replaceme...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2011.01384.x

    authors: Niebler RA,Christensen M,Berens R,Wellner H,Mikhailov T,Tweddell JS

    更新日期:2011-11-01 00:00:00

  • Influence of reuse and of reuse sterilants on the first-use syndrome.

    abstract::Over a 4 year period, five of 98 patients at our dialysis unit developed signs and symptoms consistent with first-use syndrome (FUS). Marked improvement was noted after subjecting new dialyzers to automated processing using either formaldehyde or peracetic acid. No episodes of FUS occurred in patients being treated wi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1987.tb02645.x

    authors: Vanholder R,Ringoir S

    更新日期:1987-04-01 00:00:00