Remote monitoring of left ventricular assist device parameters after HeartAssist-5 implantation.

Abstract:

:Although several left ventricular assist devices (LVADs) have been used widely, remote monitoring of LVAD parameters has been available only recently. We present our remote monitoring experience with an axial-flow LVAD (HeartAssist-5, MicroMed Cardiovascular, Inc., Houston, TX, USA). Five consecutive patients who were implanted a HeartAssist-5 LVAD because of end-stage heart failure due to ischemic (n=4) or idiopathic (n=1) cardiomyopathy, and discharged from hospital between December 2011 and January 2013 were analyzed. The data (pump speed, pump flow, power consumption) obtained from clinical visits and remote monitoring were studied. During a median follow-up of 253 (range: 80-394) days, fine tuning of LVADs was performed at clinical visits. All patients are doing well and are in New York Heart Association Class-I/II. A total of 39 alarms were received from three patients. One patient was hospitalized for suspected thrombosis and was subjected to physical examinations as well as laboratory and echocardiographic evaluations; however, no evidence of thrombus washout or pump thrombus was found. The patient was treated conservatively. Remaining alarms were due to insufficient water intake and were resolved by increased water consumption at night and summer times, and fine tuning of pump speed. No alarms were received from the remaining two patients. We believe that remote monitoring is a useful technology for early detection and treatment of serious problems occurring out of hospital thereby improving patient care. Future developments may ease troubleshooting, provide more data from the patient and the pump, and eventually increase physician and patient satisfaction. Despite all potential clinical benefits, remote monitoring should be taken as a supplement to rather than a substitute for routine clinical visits for patient follow-up.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Pektok E,Demirozu ZT,Arat N,Yildiz O,Oklu E,Eker D,Ece F,Ciftci C,Yazicioglu N,Bayindir O,Kucukaksu DS

doi

10.1111/aor.12144

subject

Has Abstract

pub_date

2013-09-01 00:00:00

pages

820-5

issue

9

eissn

0160-564X

issn

1525-1594

journal_volume

37

pub_type

杂志文章
  • In Vitro Assessment of Electric Currents Increasing the Effectiveness of Vancomycin Against Staphylococcus epidermidis Biofilms.

    abstract::Biofilms are communities of bacteria that can cause infections which are resistant to the immune system and antimicrobial treatments, posing a significant threat for patients with implantable and indwelling medical devices. The purpose of our research was to determine if utilizing specific parameters for electric curr...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12678

    authors: Haddad PA,Mah TF,Mussivand T

    更新日期:2016-08-01 00:00:00

  • Use of tactile stiffness to detect fatigue in the latissimus dorsi muscle.

    abstract::In clinical settings, no method has been established to examine the fatigue of a latissimus dorsi muscle (LDM) preconditioned for cardiomyoplasty. We examined the feasibility of measuring muscle stiffness (tactile stiffness) to evaluate muscle fatigue in situ using our tactile sensor. We stimulated canine LDM with bur...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06551.x

    authors: Inaba H,Miyaji K,Kaneko Y,Ohtsuka T,Ezure M,Tambara K,Takamoto S,Omata S

    更新日期:2000-10-01 00:00:00

  • Mathematical modeling of fluid dynamics in pulsatile cardiopulmonary bypass.

    abstract::The design criteria of an extracorporeal circuit suitable for pulsatile flow are quite different and more entangled than for steady flow. The time and costs of the design process could be reduced if mutual influences between the pulsatile pump and other extracorporeal devices were considered without experimental trial...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2003.47197.x

    authors: Pennati G,Fiore GB,Laganà K,Fumero R

    更新日期:2004-02-01 00:00:00

  • Differentiation pattern of Vero cells cultured on poly(L-lactic acid)/poly(hydroxybutyrate-co-hydroxyvalerate) blends.

    abstract::This study evaluates the effect of poly(L-lactic acid) (PLLA) and poly(hydroxybutyrate-cohydroxyvalerate) (PHBV) bioabsorbable polymers and their blends on the induction of alteration of cell growth pattern in vitro. Vero cells were cultured on PLLA, PHBV, and different blends (100/0, 60/40, 50/50, 40/60, and 0/100). ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2004.47199.x

    authors: Santos AR Jr,Ferreira BM,Duek EA,Dolder H,Wada RS,Wada ML

    更新日期:2004-04-01 00:00:00

  • Estimation of phosphene spatial variability for visual prosthesis applications.

    abstract::Visual prostheses are the focus of intensive research efforts to restore some measure of useful vision to blind or near-blind patients. The development of such technology is being guided to an extent by tools that simulate prosthesis behavior for healthy sighted subjects in order to assess system requirements and conf...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00878.x

    authors: Obeid I,Veraart C,Delbeke J

    更新日期:2010-05-01 00:00:00

  • Zero-balance ultrafiltration of the priming blood modifies the priming components and improves the clinical outcome in infants undergoing cardiopulmonary bypass: A randomized controlled trial.

    abstract::Cardiopulmonary bypass (CPB) requirement in infants presents a unique challenge because of the large prime volume-to-blood volume ratio. Packed red blood cells (PRBCs) tend to deteriorate with long-term storage owing to their unphysiological composition and osmolality. Given that blood priming is inevitable in neonate...

    journal_title:Artificial organs

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/aor.13559

    authors: Gholampour Dehaki M,Niknam S,Bakhshandeh H,Azarfarin R

    更新日期:2020-03-01 00:00:00

  • Anterior chest wall axillary artery to contralateral axillary vein graft for vascular access in hemodialysis.

    abstract::Patients with end-stage renal failure and peripheral vascular disease pose a difficult management problem in establishing long-term angioaccess for hemodialysis. In 4 patients with access problems, we created axillary artery to contralateral axillary vein Goretex grafts. The grafts were cannulated regularly for period...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1525-1594.1995.tb02291.x

    authors: Ono K,Muto Y,Yano K,Yukizane T

    更新日期:1995-12-01 00:00:00

  • Central Extracorporeal Life Support With Left Ventricular Decompression to Berlin Heart Excor: A Reliable "Bridge to Bridge" Strategy in Crash and Burn Patients.

    abstract::The aim of this study was to compare patients with severe biventricular heart failure who underwent Berlin Heart Excor implantation with (cardiogenic shock [CS] status) or without the need for preoperative extracorporeal life support (ECLS) as a bridge to long-term device. A total of 40 consecutive patients with sever...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12792

    authors: Weymann A,Farag M,Sabashnikov A,Fatullayev J,Zeriouh M,Schmack B,Arif R,Müller F,Alt C,Raake P,Prakash Patil N,Popov AF,Rüdiger Simon A,Karck M,Ruhparwar A,Heidelberg-Cologne-Harefield Cardiothoracic Transplantation & Mecha

    更新日期:2017-06-01 00:00:00

  • The status of pacemaker implantations in Japan.

    abstract::It has been over 40 years since the initial clinical application of a cardiac pacemaker. Currently, approximately 300 per million patients in the United States and Europe are kept alive owing to the benefit of implantable pacemakers. Recently, the Japanese Cardiac Pacing Society and the Japanese Society of Artificial ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1994.tb03303.x

    authors: Kojima R

    更新日期:1994-01-01 00:00:00

  • Baroreflex sensitivity of an arterial wall during rotary blood pump assistance.

    abstract::It is well known that the baroreflex system is one of the most important indicators of the pathophysiology in hypertensive patients. We can check the sensitivity of the baroreflex by observing heart rate (HR) responses; however, there is no simple diagnostic method to measure the arterial behavior in the baroreflex sy...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00864.x

    authors: Yambe T,Imachi K,Shiraishi Y,Yamaguchi T,Shibata M,Kameyama T,Yoshizawa M,Sugita N

    更新日期:2009-09-01 00:00:00

  • Aging adversely impacts biological properties of human bone marrow-derived mesenchymal stem cells: implications for tissue engineering heart valve construction.

    abstract::Our aim was to study the aging effects on the in vitro biological properties of bone marrow-derived mesenchymal stem cells (BMSCs) for construction of tissue-engineered heart valves. BMSCs were taken from teenagers with congenital heart diseases, and middle-aged and elderly patients with valvular diseases. Proliferati...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00824.x

    authors: Xin Y,Wang YM,Zhang H,Li J,Wang W,Wei YJ,Hu SS

    更新日期:2010-03-01 00:00:00

  • Beta-2-microglobulin and main granulocyte components in hemodialysis patients.

    abstract::Plasma levels of granulocyte elastase in complex with alpha 1-proteinase inhibitor (E-alpha 1-PI) increased during hemodialysis from 110 +/- 10 to 506 +/- 66 micrograms/L using dialyzers made of polyamide, from 95 +/- 2.2 to 211 +/- 54 micrograms/ml with hemophane and from 114 +/- 10 to 203 +/- 25 using dialyzers made...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1989.tb02842.x

    authors: Haag-Weber M,Schollmeyer P,Hörl WH

    更新日期:1989-04-01 00:00:00

  • Clinical indications for the use of the "Poisk-IOM" total artificial heart: the experience of 13 implantations in humans.

    abstract::Success of total artificial heart (TAH) implantation as a temporary measure depends on three factors: proper patient selection, adequate surgical technique, and safe cardiac prostheses. From 1986 until March 1990, 237 patients with stagnant heart failure were examined. Sixty-one patients (27%) were put on a waiting li...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1991.tb00745.x

    authors: Shumakov V,Zimin N,Kazakov E,Kormer A,Vorontsov S,Nikolaenko E,Kozlov I,Drobyshev A

    更新日期:1991-10-01 00:00:00

  • An image processing approach for blind mobility facilitated through visual intracortical stimulation.

    abstract::This article presents an image processing approach dedicated for a blind mobility aid facilitated through visual intracortical electrical stimulation. The method examines a display framework based on the distances related to a scene. The distances of objects to the walker are measured using a size perspective method w...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2011.01421.x

    authors: Mohammadi HM,Ghafar-Zadeh E,Sawan M

    更新日期:2012-07-01 00:00:00

  • Selective inhibition of resistance to hemopoietic allografts but not rejection to a natural killer cell sensitive tumor in transgenic mice for granulocyte colony stimulating factor.

    abstract::Transplanted allogeneic marrow grafts often fail to engraft in a lethally irradiated host. Resistance to hemopoietic allograft is a complexed phenomenon involving multiple components. To study the involvement of a hemopoietic cytokine, which was known to play a role for stem cell function, we established lines of mice...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1996.tb04563.x

    authors: Kokai Y,Kimura H,Matsuura A,Fujimoto J

    更新日期:1996-08-01 00:00:00

  • Reduction of early postoperative morbidity in cardiac surgery patients treated with continuous veno-venous hemofiltration during cardiopulmonary bypass.

    abstract::Cardiac surgery with cardiopulmonary bypass is associated with a systemic inflammatory response syndrome. The major clinical features of this include a reduction of pulmonary compliance and increased extracellular fluids, with increased pulmonary shunt fraction similar to acute respiratory distress syndrome, thus resu...

    journal_title:Artificial organs

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/j.1525-1594.2009.00777.x

    authors: Luciani R,Goracci M,Simon C,Principe F,Fazzari L,Punzo G,Menè P

    更新日期:2009-08-01 00:00:00

  • Controlled delivery of low-dose bone morphogenetic protein-2 using heparin-conjugated fibrin in the posterolateral lumbar fusion of rabbits.

    abstract::The heparin-conjugated fibrin (HCF) system has been developed to deliver bone morphogenetic proteins (BMPs) for a long-term period and thus enhance bone regeneration. In the present study, we tested the effectiveness of the delivery system for spinal fusion with a very low dose of BMP-2. A total of 15 rabbits underwen...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2012.01578.x

    authors: Koo KH,Lee JM,Ahn JM,Kim BS,La WG,Kim CS,Im GI

    更新日期:2013-05-01 00:00:00

  • Testosterone and hemoglobin in hemodialysis male and female patients.

    abstract::It has been speculated that testosterone stimulates erythropoiesis. We hypothesized that hemoglobin levels in hemodialysis (HD) patients are associated with serum testosterone concentrations. Testosterone, hemoglobin, and other biochemical parameters were measured in a representative sample of 98 chronic HD patients (...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12218

    authors: Ekart R,Taskovska M,Hojs N,Bevc S,Hojs R

    更新日期:2014-07-01 00:00:00

  • Angiographic and pathological studies on regression of coronary atherosclerosis of FH patients who received LDL-apheresis treatment.

    abstract::We report on the most recent data confirming the angiographic and pathological efficacy of LDL-apheresis for coronary atherosclerosis of a familial hypercholesterolemia (FH) patient using collected data of a large number of cases and especially of one autopsy case. Changes in coronary artery stenosis have been assesse...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1992.tb00289.x

    authors: Koga N,Iwata Y,Yamamoto A

    更新日期:1992-04-01 00:00:00

  • Numerical Simulation of Nonpulsatile Left Ventricular Bypass.

    abstract::A computer simulation was carried out to investigate the influence of nonpulsatile left ventricular assistance on hemodynamics. A simulation circuit was constructed to represent the circulatory system. A source of current was added to denote the nonpulsatile blood pump. The left and right ventricles were replaced by v...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1996.tb04494.x

    authors: Mitsui N,Fukunaga S,Koura Y,Morita S,Hotei H,Sueshiro M,Sueda T,Matsuura Y

    更新日期:1996-05-01 00:00:00

  • The OregonHeart Total Artificial Heart: Design and Performance on a Mock Circulatory Loop.

    abstract::Widespread use of heart transplantation is limited by the scarcity of donor organs. Total artificial heart (TAH) development has been pursued to address this shortage, especially to treat patients who require biventricular support. We have developed a novel TAH that utilizes a continuously spinning rotor that shuttles...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12959

    authors: Glynn J,Song H,Hull B,Withers S,Gelow J,Mudd J,Starr A,Wampler R

    更新日期:2017-10-01 00:00:00

  • Pump power loss and heat generation in a pivot bearing-supported Gyro centrifugal pump (C1E3).

    abstract::Pump power loss is defined as input power that is not used for the output work of the pump. Less pump power loss means a higher pump efficiency. A common opinion is that the pump power loss is closely related to heat generation of the pump, which may affect not only the endurance of pump materials, but also blood dama...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1996.tb04542.x

    authors: Takami Y,Nakazawa T,Makinouchi K,Glueck J,Ohara Y,Benkowski RJ,Nosé Y

    更新日期:1996-07-01 00:00:00

  • Research of flow dynamics and occlusion condition in roller pump systems used for ventricular assist.

    abstract::Roller pumps have been widely used in the ventricular assist field for many years, while the significant hemolysis caused by its mechanical stress is still a fundamental problem. Although the usual under-occlusion setting was considered as an effective method to reduce the hemolysis rate, its nonocclusive condition of...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13790

    authors: Zhou Y,Sun B,Chen M,Cui C

    更新日期:2020-07-31 00:00:00

  • Investigation of the inherent left-right flow balancing of rotary total artificial hearts by means of a resistance box.

    abstract::With the incidence of end-stage heart failure steadily increasing, the need for a practical total artificial heart (TAH) has never been greater. Continuous flow TAHs (CFTAH) are being developed using rotary blood pumps (RBPs), leveraging their small size, mechanical simplicity, and excellent durability. To completely ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13631

    authors: Nestler F,Timms DL,Stevens M,Bradley AP,Wilson SJ,Kleinheyer M,Lovell N,Frazier OH,Cohn WE

    更新日期:2020-06-01 00:00:00

  • Survival of patients on chronic hemodialysis: single center experience.

    abstract::Patient survival from our hemodialysis (HD) center over the past 11 years was analyzed. Four hundred four patients, 212 female and 192 male, were treated by chronic intermittent HD. Patients were offered standard acetate-cellulosic membranes of 1.0-1.3 m2. During this period 181 patients died. One hundred three patien...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06291.x

    authors: Polenakovik M,Sikole A,Stojcev N,Spasovski G,Amitov V,Nikolov V,Masin G,Klinkmann H

    更新日期:1999-01-01 00:00:00

  • Is the dog a useful model for accelerated calcification study of cardiovascular bioprostheses?

    abstract::Chitosan posttreatment has been shown to be effective in prevention of calcification of the glutaraldehyde treated bovine pericardium when implanted subdermally in rats for 12 weeks. The efficacy of chitosan posttreatment in complete calcium mitigation of the glutaraldehyde treated porcine aortic valves implanted in t...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb00735.x

    authors: Chanda J,Kuribayashi R,Abe T,Sekine S,Shibata Y,Yamagishi I

    更新日期:1997-05-01 00:00:00

  • The effects of homologous cross-circulation and in situ liver perfusion on fulminant hepatic failure rats.

    abstract::A galactosamine-induced fulminant hepatic failure (FHF) rat model was used to study the effects of homologous cross-circulation and in situ liver perfusion. Cross-circulation with homologous donors did not significantly improve the survival time or recovery rate of grade II hepatic coma rats. Homologous in situ liver ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1980.tb03929.x

    authors: Mohsini K,Lister C,Chang TM

    更新日期:1980-08-01 00:00:00

  • Systemic consequences of ventricular assist devices: alterations of coagulation, immune function, inflammation, and the neuroendocrine system.

    abstract::Implantable ventricular assist devices have proven efficacious as a bridge to transplantation and as a bridge to recovery. Although current indications for use of assist devices are somewhat limited, they are likely to expand in the upcoming years, including their use as destination therapy for end-stage heart failure...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1046/j.1525-1594.2002.07122.x

    authors: Hampton CR,Verrier ED

    更新日期:2002-11-01 00:00:00

  • Liposome encapsulated hemoglobin as a resuscitation fluid for hemorrhagic shock.

    abstract::The effectiveness of the blood substitute neo red cells (NRC) on hemorrhagic shock was evaluated in dogs. Shock was induced by bloodletting, and NRC was infused immediately until the dogs recovered from shock; the process was repeated 3 times (mild shock), or NRC was infused after shock was maintained for 30 min, and ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors: Usuba A,Osuka F,Kimura T,Sato R,Fujita Y,Yamashita M,Hoshino C

    更新日期:1998-02-01 00:00:00

  • Prevention of renal disease progression and renal replacement therapy in emerging countries.

    abstract::Chronic kidney disease is increasing in both developed and emerging countries with progressive encroachment on health services budgets. In spite of the lack of accurate registries, we tried to focus on the magnitude of the problem on different continents. Prevention of progression has been a remote but reachable goal....

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2006.00251.x

    authors: Hafez MH,Abdellatif DA,Elkhatib MM

    更新日期:2006-07-01 00:00:00