Baroreflex sensitivity of an arterial wall during rotary blood pump assistance.

Abstract:

:It is well known that the baroreflex system is one of the most important indicators of the pathophysiology in hypertensive patients. We can check the sensitivity of the baroreflex by observing heart rate (HR) responses; however, there is no simple diagnostic method to measure the arterial behavior in the baroreflex system. Presently, we report the development of a method and associated hardware that enables the diagnosis of baroreflex sensitivity by measuring the responses of both the heart and the artery. In this system, the measurements are obtained by monitoring an electrocardiogram and a pulse wave recorded from the radial artery or fingertip. The arterial responses were measured in terms of the pulse wave velocity (PWV) calculated from the pulse wave transmission time (PTT) from the heart to the artery. In this system, the HR change corresponding to the blood pressure change in time series sequence was observed. Slope of the changes in blood pressure and HR indicated the sensitivity of the baroreflex system of the heart. This system could also measure the sensitivity of the baroreflex system of an artery. Changes in the PWV in response to the blood pressure changes were observed. Significant correlation was observed in the time sequence between blood pressure change and PWV change after calculating the delay time by cross-correlation. The slope of these parameter changes was easily obtained and it demonstrated the sensitivity of the baroreflex system of an artery. We evaluated this method in animal experiments using rotary blood pump (RBP) with undulation pump ventricular assist device, and PTT elongation was observed in response to increased blood pressure with RBP assistance. Furthermore, when tested clinically, decreased sensitivity of the baroreflex system in hypertensive patients was observed. This system may be useful when we consider the ideal treatment and follow-up of patients with hypertension.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Yambe T,Imachi K,Shiraishi Y,Yamaguchi T,Shibata M,Kameyama T,Yoshizawa M,Sugita N

doi

10.1111/j.1525-1594.2009.00864.x

subject

Has Abstract

pub_date

2009-09-01 00:00:00

pages

767-70

issue

9

eissn

0160-564X

issn

1525-1594

pii

AOR864

journal_volume

33

pub_type

杂志文章
  • Aortic root physiology late after a "perfect" ross operation: magnetic resonance imaging study of three operative techniques.

    abstract::In order to define physiological properties of the autograft root, magnetic resonance imaging (MRI) findings relative to three different operative techniques were compared with those of control subjects. Twenty-three patients, 18/5 M/F, aged 32 ± 9 years, underwent MRI assessment of the aortic root. Patients with norm...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2011.01202.x

    authors: Luciani GB,Viscardi F,Puppini G,Faggian G,Mazzucco A

    更新日期:2011-12-01 00:00:00

  • Serum hyaluronic acid and interleukin-6 as possible markers of carpal tunnel syndrome in chronic hemodialysis patients.

    abstract::To elucidate the precise mechanism of carpal tunnel syndrome (CTS), serum hyaluronic acid (HA), interleukin-1 beta (IL-1 beta), interleukin-6 (IL-6), and tumor necrosis factor-alpha (TNF-alpha) were measured in 71 chronic hemodialysis patients with or without CTS and/or shoulder pain. Patients were divided into two gr...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1994.tb02227.x

    authors: Takasu S,Takatsu S,Kunitomo K,Kokumai Y

    更新日期:1994-06-01 00:00:00

  • Plasmapheresis-related hypotension.

    abstract::Hypotension is an uncommon complication of procedures involving extracorporeal circulation, including plasmapheresis. From November 1993 to March 1999, we treated 139 patients who underwent a total of 1,137 sessions of double filtration plasmapheresis (DFP). Hypotension was defined as a systolic blood pressure (BP) < ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06521.x

    authors: Yeh JH,Chiu HC

    更新日期:2000-09-01 00:00:00

  • Pulse push/pull hemodialysis: in vitro study on new dialysis modality with higher convective efficiency.

    abstract::Midsize molecule retention is related with renal-failure-associated mortality. Here, the authors describe a new dialysis modality, pulse push/pull hemodialysis (PPPHD), which increases convective clearance. Blood and dialysate are circulated by a pulsatile pump, but with pulsatile flow patterns that are 180 degrees ou...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00561.x

    authors: Lee K,Lee SR,Mun CH,Min BG

    更新日期:2008-05-01 00:00:00

  • Antimicrobial Wound Dressing Containing Silver Sulfadiazine With High Biocompatibility: In Vitro Study.

    abstract::Many patients all over the world suffer from acute wounds caused by traumas or burns. In most crucial cases, skin regeneration cannot be promoted spontaneously, and skin grafts are applied as the main treatment. However, this therapy has some drawbacks which motivate researchers to develop wound dressings. In this stu...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12682

    authors: Mohseni M,Shamloo A,Aghababaei Z,Vossoughi M,Moravvej H

    更新日期:2016-08-01 00:00:00

  • An implantable two channel drop foot stimulator: initial clinical results.

    abstract::This article reports preliminary results of pilot studies of a new implantable two channel drop foot stimulator. The stimulator consists of an externally worn transmitter inductively coupled to an implanted receiver unit located in the lower leg, lateral and distal to the knee. The receiver is connected to electrodes ...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1046/j.1525-1594.2002.06949.x

    authors: Kenney L,Bultstra G,Buschman R,Taylor P,Mann G,Hermens H,Holsheimer J,Nene A,Tenniglo M,van der Aa H,Hobby J

    更新日期:2002-03-01 00:00:00

  • CD4/CD8 T-cell ratio in peritoneal dialysis effluents predicts the outcome of peritonitis in patients undergoing continuous ambulatory peritoneal dialysis.

    abstract::This study aimed to clarify the role of peritoneal T-lymphocytes in peritoneal immune defense mechanisms. This study was designed to examine the changes in T-cell subpopulations during peritonitis in patients treated with continuous ambulatory peritoneal dialysis (CAPD). Our observations were correlated to responses t...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00802.x

    authors: Griveas I,Fleva A,Karanikas E,Gogos K,Sakellariou G

    更新日期:2009-12-01 00:00:00

  • Low-intensity ultrasound stimulation enhances chondrogenic differentiation in alginate culture of mesenchymal stem cells.

    abstract::Mesenchymal stem cells (MSCs) are regarded as a potential autologous source for cartilage repair, because they can differentiate into chondrocytes by transforming growth factor-beta (TGF-beta) treatment under the 3-dimensional (3-D) culture condition. However, more efficient and versatile methods for chondrogenic diff...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2006.00288.x

    authors: Lee HJ,Choi BH,Min BH,Son YS,Park SR

    更新日期:2006-09-01 00:00:00

  • Prevention of right heart failure after left ventricular assist device implantation by phosphodiesterase 5 inhibitor.

    abstract::Right ventricular (RV) function immediately after left ventricular assist device (LVAD) implantation is a crucial prognostic factor. RV failure is linked to increased mortality and worse outcome. A phosphodiesterase 5 inhibitor, sildenafil, was shown to decrease pulmonary vascular resistance and pulmonary artery press...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12277

    authors: Hamdan R,Mansour H,Nassar P,Saab M

    更新日期:2014-11-01 00:00:00

  • The role of diastolic pump flow in centrifugal blood pump hemodynamics.

    abstract::We tried to verify the hypothesis that increases in pump flow during diastole are matched by decreases in left ventricular (LV) output during systole. A calf (80 kg) was implanted with an implantable centrifugal blood pump (EVAHEART, SunMedical Technology Research Corp., Nagano, Japan) with left ventricle to aorta (LV...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2001.06864.x

    authors: Akimoto T,Litwak KN,Yamazaki K,Litwak P,Kihara SI,Tagusari O,Yamazaki SI,Kameneva MV,Watach MJ,Umezu M,Tomioka J,Kormos RL,Koyanagi H,Griffith BP

    更新日期:2001-09-01 00:00:00

  • The design modification of advanced ventricular assist device to enhance pulse augmentation and regurgitant flow shut-off.

    abstract::The new Advanced ventricular assist device (Advanced VAD) has many features such as improving pulsatility and preventing regurgitant flow during pump stoppage. The purpose of this study was to evaluate the effects of design modifications of the Advanced VAD on these features in vitro. Bench testing of four versions of...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13484

    authors: Miyamoto T,Byram N,Karimov JH,Adams J,Dessoffy R,Kuban BD,Gao S,Horvath DJ,Fukamachi K

    更新日期:2019-10-01 00:00:00

  • Development of a composite degradable/nondegradable tissue-engineered vascular graft.

    abstract::The present study aimed to determine the feasibility of constructing a reinforced autologous vascular graft by combining the advantages of fibrin gel as an autologous cell carrier material with the inherent mechanical strength of an integrated mesh structure. It was hypothesized that the mesh and dynamic culture condi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00601.x

    authors: Tschoeke B,Flanagan TC,Cornelissen A,Koch S,Roehl A,Sriharwoko M,Sachweh JS,Gries T,Schmitz-Rode T,Jockenhoevel S

    更新日期:2008-10-01 00:00:00

  • Evaluation of platelet adhesion and activation on materials for an implantable centrifugal blood pump.

    abstract::A totally implantable centrifugal artificial heart has been developed in which a pivot bearing supported centrifugal pump is used as a blood pump. The following have been adopted as blood contacting materials in our pump: titanium alloy (Ti-6A1-4V) for the housing and impeller, alumina ceramic (Al2O3) for the male piv...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.6184r.x

    authors: Takami Y,Yamane S,Makinouchi K,Niimi Y,Sueoka A,Nosé Y

    更新日期:1998-09-01 00:00:00

  • Coronary artery bypass grafting for dialysis patients: usefulness of multiarterial bypass.

    abstract::This study assessed the efficacy of multiarterial bypass in coronary artery bypass grafting (CABG) in dialysis patients. Eighty dialysis patients who underwent CABG were divided into 2 groups. Group A consisted of 38 patients in whom the left internal thoracic artery and additional saphenous vein graft (SVG) had been ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors: Nakayama Y,Sakata R,Ura M

    更新日期:2001-04-01 00:00:00

  • Use of Bedside Ultrasonography and Saline Flush Technique for Evaluation of Central Venous Catheter Placement in Children.

    abstract::Our study investigated the reliability of appearance of rapid atrial swirl flow (RASF) by ultrasonography (US) in the right atrium (RA), which occurred as a result of rapid isotonic saline infusion (RISI) into the central venous catheter (CVC), in predicting catheter tip position. This prospective observational study ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13281

    authors: Yesilbas O,Sevketoglu E,Kihtir HS,Talip Petmezci M,Akcay N,Kocoglu Barlas U,Palabiyik F

    更新日期:2018-12-01 00:00:00

  • Is Multiple Overlapping Uncovered Stents Technique Suitable for Aortic Aneurysm Repair?

    abstract::A computational fluid dynamic model to assess the impact of flow-diverter device on intra-aneurysmal flow in complex aortic aneurysm from the viewpoint of hemodynamics is presented. The aim of this study is to investigate the hemodynamic effects of an endovascular flow-diverter technique using multiple overlapping unc...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12993

    authors: Yeow SL,Leo HL

    更新日期:2018-02-01 00:00:00

  • Intrinsic coagulation pathway in end-stage renal disease associated with spinal cord injury treated with hemodialysis.

    abstract::Plasma procoagulant activities of factors XII, XI, IX, and VIII and plasma concentrations of factor XII antigen and high molecular weight kininogen (HMK) were determined in nine men with chronic renal failure (CRF) associated with long-standing spinal cord injury (SCI) treated with hemodialysis. The results were compa...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1985.tb04366.x

    authors: Vaziri ND,Winer RL,Toohey J,Danviriyasup K,Alikhani S,Eltorai I,Gordon S,Paule P

    更新日期:1985-05-01 00:00:00

  • Extracorporeal membrane oxygenator compatible with centrifugal blood pumps.

    abstract::Coil-type silicone membrane oxygenators can only be used with roller blood pumps due to the resistance from the high blood flow. Therefore, during extracorporeal membrane oxygenation (ECMO) treatment, the combination of a roller pump and an oxygenator with a high blood flow resistance will induce severe hemolysis, whi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2002.07117.x

    authors: Motomura T,Maeda T,Kawahito S,Matsui T,Ichikawa S,Ishitoya H,Kawamura M,Nishimura I,Shinohara T,Oestmann D,Glueck J,Kawaguchi Y,Sato K,Nosé Y

    更新日期:2002-11-01 00:00:00

  • Ripple reduction control of the undulation pump total artificial heart.

    abstract::An undulation pump total artificial heart (UPTAH) in which the revolutions of the motor are converted to undulation motion of a disk has been developed. In an experiment, a goat using the UPTAH survived for 54 days. However, a large ripple was observed in the device's output pressure and flow waveform. In calculating ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2002.06798.x

    authors: Saito I,Chinzei T,Mochizuki S,Abe Y,Isoyama T,Iwasaki K,Suzuki T,Karita T,Ono T,Kouno A,Ishimaru M,Baba A,Ozeki T,Tohyama T,Kobayashi Si S,Imachi K

    更新日期:2002-01-01 00:00:00

  • Single axis controlled hybrid magnetic bearing for left ventricular assist device: hybrid core and closed magnetic circuit.

    abstract::In previous studies, we presented main strategies for suspending the rotor of a mixed-flow type (centrifugal and axial) ventricular assist device (VAD), originally presented by the Institute Dante Pazzanese of Cardiology (IDPC), Brazil. Magnetic suspension is achieved by the use of a magnetic bearing architecture in w...

    journal_title:Artificial organs

    pub_type: 杂志文章,多中心研究

    doi:10.1111/j.1525-1594.2011.01265.x

    authors: da Silva I,Horikawa O,Cardoso JR,Camargo FA,Andrade AJ,Bock EG

    更新日期:2011-05-01 00:00:00

  • Detection of suction and regurgitation of the implantable centrifugal pump based on the motor current waveform analysis and its application to optimization of pump flow.

    abstract::In this study, a detection algorithm for suction and regurgitation of the centrifugal pump during left heart bypass without relying on external flow or pressure sensors was developed and evaluated in acute studies using adult goats. The detection scheme relies on power spectral density (PSD) analysis of the motor curr...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06397.x

    authors: Yuhki A,Hatoh E,Nogawa M,Miura M,Shimazaki Y,Takatani S

    更新日期:1999-06-01 00:00:00

  • Is vecuronium toxicity abolished by hemodialysis? A case report.

    abstract::Vecuronium is a curaric agent, largely used in anesthesia. Indications as to its employ in uremic patients appear to be debated because of partial renal elimination of the drug. A 52-year-old hemodialyzed woman required transplantectomy for rejection. At awakeness after general anesthesia (induced with fentanyl, propo...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06496.x

    authors: Rollino C,Visetti E,Borsa S,Pignataro A,Pozzato M,Vallero A,Quarello F

    更新日期:2000-05-01 00:00:00

  • The microsystems based visual prosthesis for optic nerve stimulation.

    abstract::The microsystems based visual prosthesis (MiViP) visual prosthesis generates visual perceptions well below safety and stimulator saturation limits. These perceptions, called phosphenes, are of reasonably small size and are broadly distributed in the visual field. They can thus be used to convey useful visual informati...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2002.06939.x

    authors: Delbeke J,Wanet-Defalque MC,Gérard B,Troosters M,Michaux G,Veraart C

    更新日期:2002-03-01 00:00:00

  • Eccentric roller type total artificial heart creating interatrial shunt.

    abstract::Creating an interatrial shunt to achieve left-right flow balance and modification of the blood chambers to improve the basic performance of the device were performed in developing an eccentric roller type total artificial heart (ERTAH). Smaller blood chambers reduce friction loss and increase durability and energy eff...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06602.x

    authors: Wada H,Fukunaga S,Watari M,Imai K,Sakai H,Shibamura H,Sueda T,Matsuura Y

    更新日期:2000-08-01 00:00:00

  • Clinical Assessment of Histidine-Tryptophan-Ketoglutarate Solution and Modified St. Thomas' Solution in Pediatric Cardiac Surgery of Tetralogy of Fallot.

    abstract::The objective of this study is to compare the myocardium protective effect of Bretschneider's histidine-tryptophan-ketoglutarate (HTK) solution versus Modified St. Thomas' (STH) solution in pediatric cardiac surgery of Tetralogy of Fallot (TOF). Seventy-seven pediatric patients of TOF who received the total surgical r...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12771

    authors: Wang ZH,An Y,Du MC,Qin TJ,Liu YB,Xu HZ,Yang LQ

    更新日期:2017-05-01 00:00:00

  • Is ionic dialysance a valid parameter for quantification of dialysis efficiency?

    abstract::The on-line measurement during hemodialysis of ionic dialysance provides an estimation of urea clearance with a good and already proven correlation. Some discrepancies remain controversial, and the influence of the dialyzer membrane is still being debated. Eighty-eight measurements of ionic dialysance (ID) were perfor...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.06062.x

    authors: Mercadal L,Petitclerc T,Jaudon MC,Béné B,Goux N,Jacobs C

    更新日期:1998-12-01 00:00:00

  • Fluid-Structure Interactions Analysis of Shear-Induced Modulation of a Mesenchymal Stem Cell: An Image-Based Study.

    abstract::Although effects of biochemical modulation of stem cells have been widely investigated, only recent advances have been made in the identification of mechanical conditioning on cell signaling pathways. Experimental investigations quantifying the micromechanical environment of mesenchymal stem cells (MSCs) are challengi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12547

    authors: Ghaemi RV,Vahidi B,Sabour MH,Haghighipour N,Alihemmati Z

    更新日期:2016-03-01 00:00:00

  • Development of an atraumatic small centrifugal pump for second-generation cardiopulmonary bypass.

    abstract::A small and light direct-drive centrifugal pump has been developed for cardiopulmonary bypass. In the development process, blood compatibility studies including a hemolysis study, an in vitro fluid dynamic performance study, and in vivo durability and feasibility studies were performed. The centrifugal pump with a 50 ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1992.tb00558.x

    authors: Jikuya T,Sasaki T,Aizawa T,Shiono M,Glueck JA,Smith CP,Feldman L,Sakuma I,Sekela ME,Noda T

    更新日期:1992-12-01 00:00:00

  • Multi-field surface electrode for selective electrical stimulation.

    abstract::We designed a 24-field array and an on-line control box that selects which and how many of 24 fields will conduct electrical charge during functional electrical stimulation. The array was made using a conductive microfiber textile, silver two-component adhesive, and the conductive ink imprint on the polycarbonate. The...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2005.29075.x

    authors: Popović-Bijelić A,Bijelić G,Jorgovanović N,Bojanić D,Popović MB,Popović DB

    更新日期:2005-06-01 00:00:00

  • Zero-balance ultrafiltration of the priming blood modifies the priming components and improves the clinical outcome in infants undergoing cardiopulmonary bypass: A randomized controlled trial.

    abstract::Cardiopulmonary bypass (CPB) requirement in infants presents a unique challenge because of the large prime volume-to-blood volume ratio. Packed red blood cells (PRBCs) tend to deteriorate with long-term storage owing to their unphysiological composition and osmolality. Given that blood priming is inevitable in neonate...

    journal_title:Artificial organs

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/aor.13559

    authors: Gholampour Dehaki M,Niknam S,Bakhshandeh H,Azarfarin R

    更新日期:2020-03-01 00:00:00