Reciprocal influences between ambulatorial peritoneal dialysis and pulmonary function.

Abstract:

:The aim of this study was to verify if dialysis solution volumes used in patients on continuous ambulatory peritoneal dialysis (CAPD) interfere with pulmonary function and if the pulmonary volumes interfere with the lymphatic absorption of the peritoneal cavity. We submitted 10 CAPD patients with a mean age of 48 +/- 18 years and on CAPD for 35 +/- 27 months to the following evaluations: first, measurement of the lymphatic absorption from the peritoneal cavity; second, measurement of the hydrostatic intraperitoneal pressure; and third, expirometry with the peritoneal cavity full of dialysis solution and empty. There were no differences between the expirometry results obtained with the peritoneal cavity full and empty of dialysis solution, and the results were in accordance with the prediction for this population. The values did not correlate with the peritoneal lymphatic absorption of the peritoneal cavity. The cumulative lymphatic absorption of the peritoneal cavity after 4 h dialysis solution permanence was 197 +/- 93 ml, and the hydrostatic intraperitoneal pressure was 13.9 +/- 2.8 column centimeters of water. Neither of these correlated with pulmonary volumes. In conclusion, CAPD did not interfere with the pulmonary function, nor did the pulmonary function influence the lymphatic absorption of the peritoneal cavity of these patients.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Marmanillo CG,Pecoits-Filho RF,Romão JE Jr,Kakehashi ET,Sabbaga E,Marcondes M,Abensur H

doi

10.1046/j.1525-1594.2001.06904.x

subject

Has Abstract

pub_date

2001-11-01 00:00:00

pages

876-81

issue

11

eissn

0160-564X

issn

1525-1594

pii

6904

journal_volume

25

pub_type

杂志文章
  • Dialyzer membranes: effect of surface area and chemical modification of cellulose on complement and platelet activation.

    abstract::Using an ex vivo model, the effects of membrane composition and surface area on both the complement system (as reflected by plasma C3a levels) and platelets [as indicated by plasma concentrations of thromboxane B2 (TXB2) and platelet factor 4 (PF4)] were studied. In this model, polyacrylonitrile (PAN) was associated w...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1987.tb02648.x

    authors: Mahiout A,Meinhold H,Kessel M,Schulze H,Baurmeister U

    更新日期:1987-04-01 00:00:00

  • Outcomes with ventricular assist device versus extracorporeal membrane oxygenation as a bridge to pediatric heart transplantation.

    abstract::Extracorporeal membrane oxygenation (ECMO) has long been the sole means of mechanical support for pediatric patients with end-stage cardiac failure, but has a high waitlist mortality and a reported survival to hospital discharge of less than 50%. The purpose of this study was to compare waitlist mortality and survival...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00969.x

    authors: Jeewa A,Manlhiot C,McCrindle BW,Van Arsdell G,Humpl T,Dipchand AI

    更新日期:2010-12-01 00:00:00

  • Dialysis reduces portal pressure in patients with chronic hepatitis C.

    abstract::The purpose of this study was to characterize changes in hepatic venous pressures in patients with chronic hepatitis C. The histology and laboratory data from patients with chronic hepatitis C who underwent a transjugular liver biopsy (TJLB) and hepatic venous pressure gradient measurement were analyzed. Portal hypert...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00925.x

    authors: Khurana S,Simcox T,Twaddell W,Drachenberg C,Flasar M

    更新日期:2010-07-01 00:00:00

  • Influence of growth hormone on maintenance of capillary-like structures in an in vitro model of stromal vascular tissue--results from morphometric analysis.

    abstract::The in vitro development of a vascular stroma might be a solution for the engineering of vascularized tissues, however, in vitro stability of capillary-like structures is limited. In order to test the influence on maintenance of capillary-like structures, human growth hormone (hGH) was added in concentrations of 0.5, ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2005.29057.x

    authors: Frerich B,Kurtz-Hoffmann J,Lindemann N

    更新日期:2005-04-01 00:00:00

  • Superior mesenteric artery mycotic aneurysm in patients with left ventricular assist device support and intravenous drug abuse.

    abstract::Mycotic aneurysm of the superior mesenteric artery (SMA) is one of the complications associated with infective endocarditis. However, there are no previous case reports in the literature describing mycotic SMA aneurysm after left ventricular assist device (LVAD) implantation. We describe the case of a 31-year-old male...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2011.01250.x

    authors: Motomura T,Bruckner B,Leon-Becerril J,Anaya-Ayala JE,de Rienzo-Madero B,Bismuth J,Bunge R,Irwin S,Loebe M

    更新日期:2011-07-01 00:00:00

  • End-point temperature of rewarming after hypothermic cardiopulmonary bypass in pediatric patients.

    abstract::In an attempt to find an adequate end-point rewarming temperature after hypothermic cardiopulmonary bypass (CPB), 50 pediatric patients who underwent cardiac surgery were randomly assigned for the end-point rectal rewarming temperature at either 35.5 (Group 1) or 37.0 degrees C (Group 2). The patients' rectal temperat...

    journal_title:Artificial organs

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/j.1525-1594.2005.00149.x

    authors: Kim WG,Yang JH

    更新日期:2005-11-01 00:00:00

  • Research of flow dynamics and occlusion condition in roller pump systems used for ventricular assist.

    abstract::Roller pumps have been widely used in the ventricular assist field for many years, while the significant hemolysis caused by its mechanical stress is still a fundamental problem. Although the usual under-occlusion setting was considered as an effective method to reduce the hemolysis rate, its nonocclusive condition of...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13790

    authors: Zhou Y,Sun B,Chen M,Cui C

    更新日期:2020-07-31 00:00:00

  • Cytotoxicity of bile in human Hep G2 cells and in primary cultures of rat hepatocytes.

    abstract::There has been increasing interest in the development of a hepatocyte bioreactor for the treatment of acute hepatic failure; however, little is known about the effect of hepatocyte byproducts on the viability of the cells in the bioreactor environment. We investigated the effects of increasing concentrations of bile o...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.06088.x

    authors: Smirthwaite AD,Gaylor JD,Cousins RB,Grant MH

    更新日期:1998-10-01 00:00:00

  • Pulse push/pull hemodialysis: in vitro study on new dialysis modality with higher convective efficiency.

    abstract::Midsize molecule retention is related with renal-failure-associated mortality. Here, the authors describe a new dialysis modality, pulse push/pull hemodialysis (PPPHD), which increases convective clearance. Blood and dialysate are circulated by a pulsatile pump, but with pulsatile flow patterns that are 180 degrees ou...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00561.x

    authors: Lee K,Lee SR,Mun CH,Min BG

    更新日期:2008-05-01 00:00:00

  • Albumin-coated Amberlite XAD-7 resin for hemoperfusion in acute liver failure. Part II: in vivo evaluation.

    abstract::Albumin-coated Amberlite XAD-7 has been previously shown to be blood compatible in in vitro hemoperfusion experiments whith human blood. In this study, the preliminary results are reported on single hemoperfusions with albumin-coated XAD-7 resin in four patients with acute liver failure. The mean platelet count was 11...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1979.tb03800.x

    authors: Hughes R,Ton HY,Langley P,Davies M,Hanid MA,Mellon P,Silk DB,Williams R

    更新日期:1979-02-01 00:00:00

  • Is ionic dialysance a valid parameter for quantification of dialysis efficiency?

    abstract::The on-line measurement during hemodialysis of ionic dialysance provides an estimation of urea clearance with a good and already proven correlation. Some discrepancies remain controversial, and the influence of the dialyzer membrane is still being debated. Eighty-eight measurements of ionic dialysance (ID) were perfor...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.06062.x

    authors: Mercadal L,Petitclerc T,Jaudon MC,Béné B,Goux N,Jacobs C

    更新日期:1998-12-01 00:00:00

  • Magnesium homeostasis in patients undergoing continuous ambulatory peritoneal dialysis: role of the dialysate magnesium concentration.

    abstract::We carried out this retrospective study to examine the magnesium status of our chronic ambulatory peritoneal dialysis (CAPD) patients dialyzed with 0.75 mmol/L (group I) or 0.50 mmol/L (group II) magnesium peritoneal dialysis solution. A total of 34 anuric patients on CAPD (age:31-72 years; duration of CAPD:7-74 month...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2003.07193.x

    authors: Katopodis KP,Koliousi EL,Andrikos EK,Pappas MV,Elisaf MS,Siamopoulos KC

    更新日期:2003-09-01 00:00:00

  • Bulk mass transport limitations during high-flux hemodialysis.

    abstract::Solute clearance during high-flux hemodialysis is determined by the combined effects of solute convection and diffusion in the membrane, blood, and dialysate. Previous studies have focused almost entirely on the membrane transport phenomena, largely ignoring the potential contribution from bulk mass transport across t...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1993.tb00403.x

    authors: Zydney AL

    更新日期:1993-11-01 00:00:00

  • Cell investigation into the biocompatibility of adult human dermal fibroblasts with PCL nanofibers/TiO2 nanotubes on the surface of Ti-30Ta alloy for biomedical applications.

    abstract::The polymer poly(ε-caprolactone) (PCL) has been used in the biomaterial field for its relatively inexpensive price and suitability for modification. Also, its chemical and biological properties are desirable for biomedical applications. The electrospinning process has been used for producing polymer fibers of PCL due ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13713

    authors: Capellato P,Silva G,Popat K,Simon-Walker R,Alves Claro AP,Zavaglia C

    更新日期:2020-08-01 00:00:00

  • Evaluation of double filtration plasmapheresis, thermofiltration, and low-density lipoprotein adsorptive methods by crossover test in the treatment of familial hypercholesterolemia patients.

    abstract::A comparative assessment has been made regarding efficacy and safety of the double filtration plasmapheresis (DFPP), thermofiltration (TFPP), and low-density lipoprotein (LDL) adsorptive (PA) methods by making a crossover test on heterozygous familial hypercholesterolemia patients. Treatments by DFPP, TFPP (secondary ...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1525-1594.1996.tb04448.x

    authors: Suzuki M,Yamane S,Matsugane T,Nobuto T,Azuma N,Nishide T,Shinomiya M,Saito K,Sasaki N,Nosé Y

    更新日期:1996-04-01 00:00:00

  • Influence of hydration state on plasma volume changes during ultrafiltration.

    abstract::To assess the influence of hydration state on plasma volume (PV) changes during ultrafiltration, 11 clinically normhydrated patients on maintenance hemodialysis were studied intraindividually during 2 hydration states differing by 2-15% of lean body mass (LBM). Plasma volume was measured continually during a 15-min ul...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1995.tb02352.x

    authors: Wizemann V,Leibinger A,Mueller K,Nilson A

    更新日期:1995-05-01 00:00:00

  • A new technique to increase coronary flow. Preliminary report.

    abstract::This study was planned to investigate whether part of the energy produced by cardiac contraction to propel blood toward the systemic circulation can be used to increase the coronary flow in systole. Ten devices (I-X) designed to divert laterally part of a flow column (without substantially increasing resistance to flo...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1979.tb01080.x

    authors: Moulopoulos S,Stamatelopoulos S,Boufas D,Yannopoulos C,Marousis G,Kouvaras G

    更新日期:1979-11-01 00:00:00

  • Gaseous micro-emboli activity during cardiopulmonary bypass in adults: pulsatile flow versus nonpulsatile flow.

    abstract::Cardiopulmonary bypass (CPB) has a risk of cerebral injury, with an important role of gaseous micro-emboli (GME) coming from the CPB circuit. Pulsatile perfusion is supposed to perform specific conditions for supplementary GME activity. We aimed to determine whether pulsatile CPB augments production and delivery of GM...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12000

    authors: Dodonov M,Milano A,Onorati F,Dal Corso B,Menon T,Ferrarini D,Tessari M,Faggian G,Mazzucco A

    更新日期:2013-04-01 00:00:00

  • Multimodal flow visualization and optimization of pneumatic blood pump for sorbent hemodialysis system.

    abstract::Renal Solutions Allient Sorbent Hemodialysis System utilizes a two-chambered pneumatic pump (Pulsar Blood Pump, Renal Solutions, Inc., Warrendale, PA, USA) to avoid limitations associated with peristaltic pumping systems. Single-needle access is enabled by counter-pulsing the two pump chambers, thereby obviating compl...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00724.x

    authors: Shu F,Parks R,Maholtz J,Ash S,Antaki JF

    更新日期:2009-04-01 00:00:00

  • Pulsatile in vitro simulation of the pediatric univentricular circulation for evaluation of cardiopulmonary assist scenarios.

    abstract::The characteristic depressed hemodynamic state and gradually declining circulatory function in Fontan patients necessitates alternative postoperative management strategies incorporating a system level approach. In this study, the single-ventricle Fontan circulation is modeled by constructing a practical in vitro bench...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00951.x

    authors: Dur O,Lara M,Arnold D,Vandenberghe S,Keller BB,DeGroff C,Pekkan K

    更新日期:2009-11-01 00:00:00

  • Quantification of Shear-Induced Platelet Activation: High Shear Stresses for Short Exposure Time.

    abstract::Thrombosis and thromboembolism are the life-threatening clinical complications for patients supported or treated with prosthetic cardiovascular devices. The high mechanical shear stress within these devices is believed to be the major contributing factor to cause platelet activation (PA) and function alteration, leadi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12438

    authors: Ding J,Chen Z,Niu S,Zhang J,Mondal NK,Griffith BP,Wu ZJ

    更新日期:2015-07-01 00:00:00

  • Thromboembolic complications of the Symbion AVAD System.

    abstract::The Symbion Acute Ventricular Assist Device (AVAD) System is an experimental paracorporeal pulsatile ventricular assist device (VAD) for single or biventricular assist. Eleven patients were implanted but 2 died within 24 h and were excluded from the study. Nine patients, four with left ventricular assist devices (LVAD...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1525-1594.1989.tb01575.x

    authors: Icenogle TB,Smith RG,Cleavinger M,Vasu MA,Williams RJ,Sethi GK,Copeland JG

    更新日期:1989-12-01 00:00:00

  • The OregonHeart Total Artificial Heart: Design and Performance on a Mock Circulatory Loop.

    abstract::Widespread use of heart transplantation is limited by the scarcity of donor organs. Total artificial heart (TAH) development has been pursued to address this shortage, especially to treat patients who require biventricular support. We have developed a novel TAH that utilizes a continuously spinning rotor that shuttles...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12959

    authors: Glynn J,Song H,Hull B,Withers S,Gelow J,Mudd J,Starr A,Wampler R

    更新日期:2017-10-01 00:00:00

  • Resection of huge retrosternal goiter through a novel combined cervical and robot-assisted approach.

    abstract::A 53-year-old man was referred to our department with a history of cough, especially at night, for 3 months. He was found to have a huge retrosternal goiter. We applied a novel combined cervical and robot-assisted approach to resect this difficult goiter. Using the da Vinci robot system, the intrathoracic part of the ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12196

    authors: Wang S,Xu S,Liu B

    更新日期:2014-05-01 00:00:00

  • Heart Transplant Waiting List Implications of Increased Ventricular Assist Device Use as a Bridge Strategy: A National Analysis.

    abstract:BACKGROUND:The use of ventricular assist devices (VAD) as a bridge to heart transplant (HT) is increasing, while HT volume remains stagnant. This may portend longer waiting times and an otherwise more competitive environment for all patients on the HT waiting list. METHODS:A retrospective analysis of patients who were...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13833

    authors: Han JJ,Elzayn H,Duda MM,Iyengar A,Acker AM,Patrick WL,Helmers M,Birati EY,Atluri P

    更新日期:2020-10-01 00:00:00

  • Down-regulation of TNF-alpha by small interfering RNA inhibits particle-induced inflammation in vitro.

    abstract::Aseptic joint loosening is a key factor that reduces the life span of arthroplasty. There are currently few effective treatments for joint loosening except surgical revision. We explored the inhibitory effects of tumor necrosis factor (TNF)-alpha-targeted small interfering RNA (siRNA) on particle-induced inflammatory ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2010.01175.x

    authors: Qin CQ,Ding Y,Huang DS,Xu J,Ma RF,Huang JB

    更新日期:2011-07-01 00:00:00

  • Hypertension and end-stage renal disease in the developing world.

    abstract::Hypertension is an important primary etiology of end-stage renal disease as well as a major factor responsible for progression of renal disease due to other causes. Multiple genetic and environmental factors are responsible for the variable prevalence of hypertension in various parts of the world. Although the frequen...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2002.07067.x

    authors: El-Khashab O

    更新日期:2002-09-01 00:00:00

  • Electrical pulse train and single pulse stimulation of the small intestine: acute and chronic studies in the dog.

    abstract::In vitro tests have shown that electric currents may lead either to relaxation or contraction of the bowel wall. Because voluntary changes of the intestinal motility could be useful in the treatment of intestinal disorders, we investigated the reactions elicited by electrostimulation of the small intestine in the inta...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1989.tb02846.x

    authors: Moritz A,Grundfest-Broniatowski S,Ilyes L,Kasick J,Jacobs G,Olsen E,Nosé Y

    更新日期:1989-04-01 00:00:00

  • Correlation between cerebral-renal near-infrared spectroscopy and ipsilateral renal perfusion parameters as clinical outcome predictors after open heart surgery in neonates and infants.

    abstract::The objective of this clinical study is to determine whether correlation exists among cerebral and renal near-infrared spectroscopy (NIRS) measurements, renal Doppler ultrasonography parameters (resistive index, peak systolic velocity), and early postoperative clinical outcomes following cardiac surgery in neonates an...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12455

    authors: Örmeci T,Alkan-Bozkaya T,Özyüksel A,Ersoy C,Ündar A,Akçevin A,Türkoğlu H

    更新日期:2015-01-01 00:00:00

  • Pulse conductance and flow-induced hemolysis during pulsatile cardiopulmonary bypass.

    abstract::In this study, the hypothesis was tested that a low-resistant, high-compliant oxygenator provides better pulse conductance and less hemolysis than a high-resistant, low-compliant oxygenator during pulsatile cardiopulmonary bypass. Forty adults undergoing coronary artery bypass surgery were randomly divided into two gr...

    journal_title:Artificial organs

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/j.1525-1594.2009.00853.x

    authors: Simons AP,Wortel P,van Kan RA,van der Veen FH,Weerwind PW,Maessen JG

    更新日期:2010-04-01 00:00:00