Double catheterization of the internal jugular vein for hemodialysis: indications, techniques, and clinical results.

Abstract:

:Central vascular catheters are used to access the central vascular system in both acute and chronic uremic patients undergoing hemodialysis. Among different approaches, the internal jugular vein seems to have less adverse effects. We describe our long-term experience with a two-catheter system. Percutaneous jugular vein cannulation was performed using Medcomp silicone rubber catheters. The study included 108 patients undergoing hemodialysis. One- and 2-year survival was 93 and 91%, respectively; 36 died because of unrelated causes. Blood flow rate was 284 mL/min; venous pressure at 1 year was 90 mm Hg. Complications included accidental withdrawal (6), dysfunction (4), catheter clotting (11), mediastinal hematoma (2), pneumothorax (1), and sepsis (7). Good long-term survival and a low complication rate make this system a safe and reliable method of access for long-term hemodialysis.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Tesio F,De Baz H,Panarello G,Calianno G,Quaia P,Raimondi A,Schinella D

doi

10.1111/j.1525-1594.1994.tb02200.x

subject

Has Abstract

pub_date

1994-04-01 00:00:00

pages

301-4

issue

4

eissn

0160-564X

issn

1525-1594

journal_volume

18

pub_type

杂志文章
  • Use of Bedside Ultrasonography and Saline Flush Technique for Evaluation of Central Venous Catheter Placement in Children.

    abstract::Our study investigated the reliability of appearance of rapid atrial swirl flow (RASF) by ultrasonography (US) in the right atrium (RA), which occurred as a result of rapid isotonic saline infusion (RISI) into the central venous catheter (CVC), in predicting catheter tip position. This prospective observational study ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13281

    authors: Yesilbas O,Sevketoglu E,Kihtir HS,Talip Petmezci M,Akcay N,Kocoglu Barlas U,Palabiyik F

    更新日期:2018-12-01 00:00:00

  • Magnesium homeostasis in patients undergoing continuous ambulatory peritoneal dialysis: role of the dialysate magnesium concentration.

    abstract::We carried out this retrospective study to examine the magnesium status of our chronic ambulatory peritoneal dialysis (CAPD) patients dialyzed with 0.75 mmol/L (group I) or 0.50 mmol/L (group II) magnesium peritoneal dialysis solution. A total of 34 anuric patients on CAPD (age:31-72 years; duration of CAPD:7-74 month...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2003.07193.x

    authors: Katopodis KP,Koliousi EL,Andrikos EK,Pappas MV,Elisaf MS,Siamopoulos KC

    更新日期:2003-09-01 00:00:00

  • Cytotoxicity and genotoxicity of bovine pericardium preserved in glycerol.

    abstract::Bovine pericardium is a widely utilized biomaterial. Usually, after harvesting, it is advantageous that the pericardium be immersed in glycerol to improve its shelf life. This can induce some degree of toxicity in the material. The studies were performed in compliance with the rules of ISO 10993 and OECD 487, in the b...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00542.x

    authors: Rodas AC,Maizato MJ,Leirner AA,Pitombo RN,Polakiewicz B,Beppu MM,Higa OZ

    更新日期:2008-04-01 00:00:00

  • Cerebral and lower limb near-infrared spectroscopy in adults on extracorporeal membrane oxygenation.

    abstract::Percutaneous femoral venoarterial (VA) or jugular venovenous (VV) extracorporeal membrane oxygenation (ECMO) can result in delivery of hypoxic blood to the brain, coronaries, and upper extremities. Additionally, VA-ECMO by percutaneous femoral artery cannulation may compromise perfusion to the lower limbs. Use of near...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2012.01496.x

    authors: Wong JK,Smith TN,Pitcher HT,Hirose H,Cavarocchi NC

    更新日期:2012-08-01 00:00:00

  • Femoro-femoral versus atrio-aortic extracorporeal membrane oxygenation: selecting the ideal cannulation technique.

    abstract::Veno-arterial extracorporeal membrane oxygenation (ECMO) may be implanted using peripheral ECMO (pECMO) or central ECMO (cECMO) cannulation techniques. The aim of this study was to compare the outcome between these two cannulation techniques. A retrospective study was performed at Düsseldorf University Hospital from O...

    journal_title:Artificial organs

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/aor.12245

    authors: Saeed D,Stosik H,Islamovic M,Albert A,Kamiya H,Maxhera B,Lichtenberg A

    更新日期:2014-07-01 00:00:00

  • Single axis controlled hybrid magnetic bearing for left ventricular assist device: hybrid core and closed magnetic circuit.

    abstract::In previous studies, we presented main strategies for suspending the rotor of a mixed-flow type (centrifugal and axial) ventricular assist device (VAD), originally presented by the Institute Dante Pazzanese of Cardiology (IDPC), Brazil. Magnetic suspension is achieved by the use of a magnetic bearing architecture in w...

    journal_title:Artificial organs

    pub_type: 杂志文章,多中心研究

    doi:10.1111/j.1525-1594.2011.01265.x

    authors: da Silva I,Horikawa O,Cardoso JR,Camargo FA,Andrade AJ,Bock EG

    更新日期:2011-05-01 00:00:00

  • Nonsymmetric leaflet motion of St. Jude Medical mitral valves simulated with a computer-controlled hydraulic mock circulator.

    abstract::Since the introduction of high-performance prosthetic heart valves, particularly bileaflet valves and monoleaflet valves with larger opening angles, we have observed in vivo complex leaflet motion which has not been experimentally confirmed yet. We developed a computer-controlled hydraulic mock circulator to study the...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb00373.x

    authors: Ohta Y,Okamoto K,Sonderegger M,Dohi T,Matsumoto H,Horiuchi T

    更新日期:1997-04-01 00:00:00

  • Is the New Infant Jarvik 2015 Suitable for Patients

    abstract::Our aim was to study the feasibility of implanting the Infant Jarvik 2015 in patients weighing less than 8 kg. The Infant Jarvik 2015 left ventricular assist device (LVAD) was tested in a hybrid simulator of the cardiovascular system reproducing specific patients' hemodynamics for different patient weights (2-7 kg). F...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13302

    authors: Di Molfetta A,Zielinski K,Ferrari G,Kozarski M,Okrzeja P,Iacobelli R,Filippelli S,Perri G,Darowski M,Massetti M,Jarvik R,Amodeo A

    更新日期:2019-01-01 00:00:00

  • Cell adhesive and antifouling polyvinyl chloride surfaces via wet chemical modification.

    abstract::Polyvinyl chloride (PVC) is one of the most frequently used polymers for the manufacturing of medical devices. Limitations for its usage are based upon unfavorable surface properties of the polymer including its hydrophobicity and lack of functionalities in order to increase its versatility. To address this issue, wet...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2012.01462.x

    authors: Gabriel M,Strand D,Vahl CF

    更新日期:2012-09-01 00:00:00

  • Miniaturization of a magnetically levitated axial flow blood pump.

    abstract::This article introduces a unique miniaturization process of a magnetically levitated axial flow blood pump from a functional prototype to a pump suitable for animal trials. Through COMSOL three-dimensional finite element analysis and experimental verification, the hybrid magnetic bearings of the pump have been miniatu...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2010.01077.x

    authors: Cheng S,Olles MW,Olsen DB,Joyce LD,Day SW

    更新日期:2010-10-01 00:00:00

  • Hemodynamic controller for left ventricular assist device based on pulsatility ratio.

    abstract::Hemodynamic control of left ventricular assist devices (LVADs) is generally a complicated problem due to diverse operating environments and the variability of the patients: both the changes in the circulatory and metabolic parameters as well as disturbances that require adjustment to the operating point. This challeng...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2007.00350.x

    authors: Choi S,Boston JR,Antaki JF

    更新日期:2007-02-01 00:00:00

  • Evidence of absence of porcine endogenous retrovirus (PERV) infection in patients treated with a bioartificial liver support system.

    abstract::Porcine endogenous retrovirus (PERV) genomes are present in all pig cells. In this retrospective study, we assessed PERV infectivity in 28 patients treated with an extracorporeal bioartificial liver (HepatAssist system) that includes a membrane device containing porcine hepatocytes. All patients tested negative for PE...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06444.x

    authors: Pitkin Z,Mullon C

    更新日期:1999-09-01 00:00:00

  • Long-term performance of homograft and autograft valves.

    abstract::Five hundred and eighty homograft valves have been inserted into the aortic position as isolated valve replacements, and followed up for 7--14 years. After ten years 90% of frozen homografts, 80% of autografts and 70% of freeze-dried homografts were free of valve-related death. There was only one embolism reported giv...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1980.tb03894.x

    authors: Bodnar E,Wain WH,Martelli V,Ross DN

    更新日期:1980-02-01 00:00:00

  • Thromboembolic complications of the Symbion AVAD System.

    abstract::The Symbion Acute Ventricular Assist Device (AVAD) System is an experimental paracorporeal pulsatile ventricular assist device (VAD) for single or biventricular assist. Eleven patients were implanted but 2 died within 24 h and were excluded from the study. Nine patients, four with left ventricular assist devices (LVAD...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1525-1594.1989.tb01575.x

    authors: Icenogle TB,Smith RG,Cleavinger M,Vasu MA,Williams RJ,Sethi GK,Copeland JG

    更新日期:1989-12-01 00:00:00

  • Analysis of left ventricular impedance in comparison with ultrasound images.

    abstract::Cardiac monitoring of ventricular assist devices (VADs) is important for detecting heart failure risks, such as critical arrhythmia and ventricular fibrillation, and for supplying data that are useful for hemodynamic control. Specifically, impedance cardiograms (ICGs) are especially beneficial because they have no eff...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2011.01381.x

    authors: Choi SW,Park SM

    更新日期:2012-05-01 00:00:00

  • Adult polycystic kidney disease: who needs hospital follow-up?

    abstract::Clinical data from 120 adult patients with genetically undifferentiated polycystic kidney disease who had been followed up for more than 3 months (range 3-172) were reviewed in order to try to identify clinical indicators that might predict deterioration in renal function. They were split into two groups dependent on ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2012.01441.x

    authors: Griveas I,Bishop K,World M

    更新日期:2012-07-01 00:00:00

  • Liposome-encapsulated hemoglobin alleviates brain edema after permanent occlusion of the middle cerebral artery in rats.

    abstract::Liposome-encapsulated hemoglobin (LEH) was proven to be protective in cerebral ischemia/reperfusion injury. The present study evaluated LEH in a rat model of permanent middle cerebral artery (MCA) occlusion to clarify its effect during ischemia and reperfusion. Five minutes after thread occlusion of the MCA, rats were...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00700.x

    authors: Kawaguchi AT,Kurita D,Furuya H,Yamano M,Ogata Y,Haida M

    更新日期:2009-02-01 00:00:00

  • Evaluation of platelet adhesion and activation on materials for an implantable centrifugal blood pump.

    abstract::A totally implantable centrifugal artificial heart has been developed in which a pivot bearing supported centrifugal pump is used as a blood pump. The following have been adopted as blood contacting materials in our pump: titanium alloy (Ti-6A1-4V) for the housing and impeller, alumina ceramic (Al2O3) for the male piv...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.6184r.x

    authors: Takami Y,Yamane S,Makinouchi K,Niimi Y,Sueoka A,Nosé Y

    更新日期:1998-09-01 00:00:00

  • Charged compounds of the glomerular filter and their role in normal and disordered permselectivity.

    abstract::Infusion into rats of the polycation hexadimethrine (HDM) leads to onset of massive proteinuria, which recovers when the infusion is stopped. Several lines of evidence indicate that the proteinuria results from binding of HDM to polyanions of the glomerular filter, with neutralization of shielding of their charges. To...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1987.tb02712.x

    authors: Hunsicker LG,Bertolatus JA

    更新日期:1987-12-01 00:00:00

  • Effect of a balanced biventricular bypass system on left ventricular energies.

    abstract::Left dominant biventricular failure is a common type of heart failure after cardiac surgery. We developed a biventricular bypass (BVB) system for treatment of postcardiotomy ventricular failure, and we previously reported that the clinical results of the BVB system were superior to those obtained with venoarterial byp...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.06015.x

    authors: Kodera K,Kitamura M,Shibuya M,Kurihara H,Koyanagi H

    更新日期:1998-09-01 00:00:00

  • Stem damage during implantation of modular hip prostheses.

    abstract::Modular hip prostheses are commonly used today. Dedicated surgical auxiliary instrumentation is indispensable. A correct coupling between the prosthesis and the instrument is necessary to avoid damage. Based on a specific commercial design (AnCAFit, Wright Cremascoli Ortho, Toulon, France), the aim of this work was to...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2006.00261.x

    authors: Varini E,Cristofolini L,Viceconti M,Traina F

    更新日期:2006-07-01 00:00:00

  • Oxidative Stress Increases Erythrocyte Sensitivity to Shear-Mediated Damage.

    abstract::Patients receiving mechanical circulatory support often present with heightened inflammation and free radical production associated with pre-existing conditions in addition to that which is due to blood interactions with nonbiological surfaces. The aim of this experimental laboratory study was to assess the deformabil...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12997

    authors: McNamee AP,Horobin JT,Tansley GD,Simmonds MJ

    更新日期:2018-02-01 00:00:00

  • A new blood pump for cardiopulmonary bypass: the HiFlow centrifugal pump.

    abstract::Centrifugal blood pumps are considered to be generally superior to the traditionally used roller pumps in cardiopulmonary bypass. In our institute a new lightweight centrifugal sealless blood pump with a unique spherical thrust bearing and with a magnetic coupling was developed, the HiFlow. The small design makes the ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb03754.x

    authors: Göbel C,Eilers R,Reul H,Schwindke P,Jörger M,Rau G

    更新日期:1997-07-01 00:00:00

  • An implantable two channel drop foot stimulator: initial clinical results.

    abstract::This article reports preliminary results of pilot studies of a new implantable two channel drop foot stimulator. The stimulator consists of an externally worn transmitter inductively coupled to an implanted receiver unit located in the lower leg, lateral and distal to the knee. The receiver is connected to electrodes ...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1046/j.1525-1594.2002.06949.x

    authors: Kenney L,Bultstra G,Buschman R,Taylor P,Mann G,Hermens H,Holsheimer J,Nene A,Tenniglo M,van der Aa H,Hobby J

    更新日期:2002-03-01 00:00:00

  • An image processing approach for blind mobility facilitated through visual intracortical stimulation.

    abstract::This article presents an image processing approach dedicated for a blind mobility aid facilitated through visual intracortical electrical stimulation. The method examines a display framework based on the distances related to a scene. The distances of objects to the walker are measured using a size perspective method w...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2011.01421.x

    authors: Mohammadi HM,Ghafar-Zadeh E,Sawan M

    更新日期:2012-07-01 00:00:00

  • Failure of platelet markers to evaluate membrane biocompatibility during a combined hemodialysis-hemoperfusion treatment.

    abstract::Plasma levels of the platelet markers beta-thromboglobulin (beta-TG) and platelet factor 4 (PF4) are among the most sophisticated indexes of biocompatibility available to evaluate new members for hemodialysis. This investigation was designed to determine the extent of platelet activation by measuring the alpha-granule...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1987.tb00954.x

    authors: Buccianti G,Giaretto S,Pogliani EM,Lorenz M,Valenti G,Bianchi ML,Cresseri D

    更新日期:1987-10-01 00:00:00

  • Is ionic dialysance a valid parameter for quantification of dialysis efficiency?

    abstract::The on-line measurement during hemodialysis of ionic dialysance provides an estimation of urea clearance with a good and already proven correlation. Some discrepancies remain controversial, and the influence of the dialyzer membrane is still being debated. Eighty-eight measurements of ionic dialysance (ID) were perfor...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.06062.x

    authors: Mercadal L,Petitclerc T,Jaudon MC,Béné B,Goux N,Jacobs C

    更新日期:1998-12-01 00:00:00

  • Paracorporeal artificial heart in postoperative heart failure.

    abstract::A pneumatically driven artificial heart with a tubular silicone rubber membrane and disc valves was used for functional heart replacement in the paracorporeal mode. A fluidic drive system allows adjustment of the heart rate, positive and negative pressures and systole/diastole ratio. Since August, 1977, the artificial...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1978.tb03465.x

    authors: Turina MT,Bosio R,Senning A

    更新日期:1978-08-01 00:00:00

  • Experimental high-volume hemofiltration with predilutional tris-hydroxymethylaminomethane for correction of low tidal volume ventilation-induced acidosis.

    abstract::The most common method of controlling acidemia during lung-protective ventilation is CO₂ removal with an extracorporeal lung assist (ECLA) system. Another possibility to prevent acidemia is based on intravenous (i.v.) application of tris-hydroxymethyl-aminomethane (3 mol/L, THAM) buffer, which can bind hydrogen proton...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2011.01204.x

    authors: Russ M,Deja M,Ott S,Bedarf J,Keckel T,Hiebl B,Wagner JJ,Unger JK

    更新日期:2011-06-01 00:00:00

  • Evaluation of membrane oxygenators and reservoirs in terms of capturing gaseous microemboli and pressure drops.

    abstract::An increasing amount of evidence points to cerebral embolization during cardiopulmonary bypass (CPB) as the principal etiologic factor of neurologic complications. In this study, the capability of capturing and classification of gaseous emboli and pressure drop of three different membrane oxygenators (Sorin Apex, Teru...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00955.x

    authors: Guan Y,Palanzo D,Kunselman A,Undar A

    更新日期:2009-11-01 00:00:00