Effect of a balanced biventricular bypass system on left ventricular energies.

Abstract:

:Left dominant biventricular failure is a common type of heart failure after cardiac surgery. We developed a biventricular bypass (BVB) system for treatment of postcardiotomy ventricular failure, and we previously reported that the clinical results of the BVB system were superior to those obtained with venoarterial bypass (VAB). The purpose of this study was to evaluate the effect of the BVB system on left ventricular (LV) performance in comparison to that of VAB by means of the LV pressure-volume relationship (PVR). Eight adult mongrel dogs (14-21 kg) underwent VAB with right atrial and aortic cannulation. Left atrial cannulation was added for BVB, and both atrial drainage tubes were joined with a Y-shaped connector. The bypass flow was maintained at half of the baseline cardiac output (0.7-1.0 L/min), and the hemodynamic parameters were monitored. A high fidelity microtip catheter and a conductance catheter were used to evaluate LV function. The slope of the LV end-systolic pressure-volume relation (Emax), the slope of the LV end-systolic pressure-stroke-volume relation (Ea), the LV stroke work (SW), LV potential energy (PE), LV pressure-volume area (PVA), the slope of the SW end-diastolic volume relation (PRSW), and an index of the LV energizing charge (ratio of PE/PVA) were assessed during transient occlusion of the inferior vena cava. LV contractility (Emax) showed no significant change during each experiment. Standardized LV work (PRSW) was reduced by BVB in comparison to the baseline and in comparison to VAB. The rate of LV energy charge (PE/PVA) significantly increased only during BVB. These results suggested that the BVB system might be an effective circulatory support for reducing LV work and improving the LV energizing charge in patients with severe heart failure after cardiac operation.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Kodera K,Kitamura M,Shibuya M,Kurihara H,Koyanagi H

doi

10.1046/j.1525-1594.1998.06015.x

subject

Has Abstract

pub_date

1998-09-01 00:00:00

pages

803-7

issue

9

eissn

0160-564X

issn

1525-1594

journal_volume

22

pub_type

杂志文章
  • The OregonHeart Total Artificial Heart: Design and Performance on a Mock Circulatory Loop.

    abstract::Widespread use of heart transplantation is limited by the scarcity of donor organs. Total artificial heart (TAH) development has been pursued to address this shortage, especially to treat patients who require biventricular support. We have developed a novel TAH that utilizes a continuously spinning rotor that shuttles...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12959

    authors: Glynn J,Song H,Hull B,Withers S,Gelow J,Mudd J,Starr A,Wampler R

    更新日期:2017-10-01 00:00:00

  • Systemic consequences of ventricular assist devices: alterations of coagulation, immune function, inflammation, and the neuroendocrine system.

    abstract::Implantable ventricular assist devices have proven efficacious as a bridge to transplantation and as a bridge to recovery. Although current indications for use of assist devices are somewhat limited, they are likely to expand in the upcoming years, including their use as destination therapy for end-stage heart failure...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1046/j.1525-1594.2002.07122.x

    authors: Hampton CR,Verrier ED

    更新日期:2002-11-01 00:00:00

  • Fluctuations of the hemodynamic derivatives during left ventricular assistance using oscillated blood flow.

    abstract::To analyze the autonomic nervous system during left heart bypass with a vibrating flow pump (VFP), fluctuations in hemodynamic derivatives were evaluated by the spectral analysis method using fast fourier transform methodology. After the left pleural cavity was opened through the fourth intercostal space under general...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors: Yambe T,Kobayashi S,Nanka S,Naganuma S,Nitta S,Matsuki H,Abe K,Yoshizawa M,Fukuju T,Tabayashi K,Takeda H,Hashimoto H

    更新日期:1996-06-01 00:00:00

  • Peritoneal dialysis for the removal of protein-bound markers of hepatic insufficiency.

    abstract::The addition of human serum albumin (HSA) to peritoneal dialysate increases the clearance of bilirubin in rats suffering from obstructive jaundice. The acceptor properties of the fluid can be enhanced by using HSA that does not contain standard stabilizing additives and has been purified by further adsorption on activ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1993.tb00390.x

    authors: Sarnatskaya VV,Nikolaev VG,Osipova LA,Ivanov AI,Maslenny VN,Ivanyuk AA,Yushko LA

    更新日期:1993-10-01 00:00:00

  • The Effect of Diode Laser With Different Parameters on Root Fracture During Irrigation Procedure.

    abstract::The aim of this study is to compare the effect of a single diode laser application and agitation of EDTA with diode laser with different parameters at different time intervals on root fracture. Ninety mandibular incisors were instrumented except the negative control group. The specimens were divided randomly into 10 g...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12608

    authors: Karataş E,Arslan H,Topçuoğlu HS,Yılmaz CB,Yeter KY,Ayrancı LB

    更新日期:2016-06-01 00:00:00

  • Are standard human coagulation tests suitable in pigs and calves during extracorporeal circulation?

    abstract::The thrombogenicity of membrane oxygenators as well as clotting parameters profiles, using standard human clotting tests, was analyzed in calves and pigs during 6 h perfusion. Three calves and 3 pigs were connected to extracorporeal circulation with standard heparinization. Blood samples were taken for coagulation var...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2001.025007579.x

    authors: Mueller XM,Tevaearai HT,Jegger D,Tucker O,von Segesser LK

    更新日期:2001-07-01 00:00:00

  • Pump power loss and heat generation in a pivot bearing-supported Gyro centrifugal pump (C1E3).

    abstract::Pump power loss is defined as input power that is not used for the output work of the pump. Less pump power loss means a higher pump efficiency. A common opinion is that the pump power loss is closely related to heat generation of the pump, which may affect not only the endurance of pump materials, but also blood dama...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1996.tb04542.x

    authors: Takami Y,Nakazawa T,Makinouchi K,Glueck J,Ohara Y,Benkowski RJ,Nosé Y

    更新日期:1996-07-01 00:00:00

  • Angiographic and pathological studies on regression of coronary atherosclerosis of FH patients who received LDL-apheresis treatment.

    abstract::We report on the most recent data confirming the angiographic and pathological efficacy of LDL-apheresis for coronary atherosclerosis of a familial hypercholesterolemia (FH) patient using collected data of a large number of cases and especially of one autopsy case. Changes in coronary artery stenosis have been assesse...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1992.tb00289.x

    authors: Koga N,Iwata Y,Yamamoto A

    更新日期:1992-04-01 00:00:00

  • Standing up with denervated muscles in humans using functional electrical stimulation.

    abstract::The use of electrical stimulation for denervated muscles is still considered to be a controversial issue by many rehabilitation facilities and medical professionals because prior clinical experience has shown that treating denervated muscle tissue using exponential current over a long time period constitutes an imposs...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06376.x

    authors: Kern H,Hofer C,Strohhofer M,Mayr W,Richter W,Stöhr H

    更新日期:1999-05-01 00:00:00

  • Changes in Spirometry After Left Ventricular Assist Device Implantation.

    abstract::Left ventricular assist devices (LVADs) are increasingly being used as life-saving therapy in patients with end-stage heart failure. The changes in spirometry following LVAD implantation and subsequent unloading of the left ventricle and pulmonary circulation are unknown. In this study, we explored long-term changes i...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12507

    authors: Mohamedali B,Bhat G,Yost G,Tatooles A

    更新日期:2015-12-01 00:00:00

  • The Helmholtz Total Artificial Heart Labtype.

    abstract::To perform the first experimental tests for validation of a new gear unit concept, the pump chamber, diaphragm, and pusher plate design of an orthotopic electromechanical total artificial heart (TAH) (Helmholtz Labtype) was manufactured. In its early stage of development, it provides some of the most important feature...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1994.tb03374.x

    authors: Kaufmann R,Reul H,Rau G

    更新日期:1994-07-01 00:00:00

  • Rotary blood pump flow spontaneously increases during exercise under constant pump speed: results of a chronic study.

    abstract::Many types of rotary blood pumps and pump control methods have recently been developed with the goal of clinical use. From experiments, we know that pump flow spontaneously increases during exercise without changing pump control parameters. The purpose of this study was to determine the hemodynamics associated with th...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06426.x

    authors: Akimoto T,Yamazaki K,Litwak P,Litwak KN,Tagusari O,Mori T,Antaki JF,Kameneva MV,Watach MJ,Umezu M,Tomioka J,Kormos RL,Koyanagi H,Griffith BP

    更新日期:1999-08-01 00:00:00

  • Pre- and postoperative magnetic resonance imaging in neonatal arterial switch operation using warm perfusion.

    abstract::Neurological morbidity is a major concern in pediatric cardiac surgery. Cardiopulmonary bypass is one of the few modifiable factors affecting neurodevelopmental outcome. This study aimed to measure the incidence of abnormalities apparent by magnetic resonance imaging (MRI) after neonatal arterial switch operation usin...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2011.01325.x

    authors: Durandy Y,Rubatti M,Couturier R,Rohnean A

    更新日期:2011-11-01 00:00:00

  • Evidence of absence of porcine endogenous retrovirus (PERV) infection in patients treated with a bioartificial liver support system.

    abstract::Porcine endogenous retrovirus (PERV) genomes are present in all pig cells. In this retrospective study, we assessed PERV infectivity in 28 patients treated with an extracorporeal bioartificial liver (HepatAssist system) that includes a membrane device containing porcine hepatocytes. All patients tested negative for PE...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06444.x

    authors: Pitkin Z,Mullon C

    更新日期:1999-09-01 00:00:00

  • Reciprocal influences between ambulatorial peritoneal dialysis and pulmonary function.

    abstract::The aim of this study was to verify if dialysis solution volumes used in patients on continuous ambulatory peritoneal dialysis (CAPD) interfere with pulmonary function and if the pulmonary volumes interfere with the lymphatic absorption of the peritoneal cavity. We submitted 10 CAPD patients with a mean age of 48 +/- ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2001.06904.x

    authors: Marmanillo CG,Pecoits-Filho RF,Romão JE Jr,Kakehashi ET,Sabbaga E,Marcondes M,Abensur H

    更新日期:2001-11-01 00:00:00

  • Hemodynamic controller for left ventricular assist device based on pulsatility ratio.

    abstract::Hemodynamic control of left ventricular assist devices (LVADs) is generally a complicated problem due to diverse operating environments and the variability of the patients: both the changes in the circulatory and metabolic parameters as well as disturbances that require adjustment to the operating point. This challeng...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2007.00350.x

    authors: Choi S,Boston JR,Antaki JF

    更新日期:2007-02-01 00:00:00

  • In vitro generation of atrioventricular heart valve neoscaffolds.

    abstract::Tissue engineering of cardiovascular structures represents a novel approach to improve clinical strategies in heart valve disease treatment. The aim of this study was to engineer decellularized atrioventricular heart valve neoscaffolds with an intact ultrastructure and to reseed them with umbilical cord-derived endoth...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12321

    authors: Weymann A,Radovits T,Schmack B,Li S,Korkmaz S,Soós P,Istók R,Veres G,Chaimow N,Karck M,Szabó G

    更新日期:2014-07-01 00:00:00

  • A computational study of the effects of inlet guide vanes on the performance of a centrifugal blood pump.

    abstract::This article presents computational studies on the effects of inlet guide vanes (IGVs) on the flow pattern and shear stress in a centrifugal blood pump. The effect of IGVs is to introduce a pre-swirl to fluid particles entering the impeller with the intention that the fluid particles will travel along the blade profil...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2002.06917.x

    authors: Chan WK,Wong YW,Yu SC,Chua LP

    更新日期:2002-06-01 00:00:00

  • Ductular cholestasis, an unusual form of intrahepatic cholestasis, associated with cardiogenic shock and ventricular assist device.

    abstract::Ventricular assist devices have been shown to be effective in advanced heart failure selected patients. They often have borderline end-organ function, what facilitates organ dysfunction. Liver failure is difficult to manage and leads to increased morbidity and mortality. We report a case of ductular cholestasis, an un...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00760.x

    authors: Mohedano-Gómez A,Pérez-Vela JL,Renes-Carreño E,De-Andrés CI,Corres-Peiretti MA,Arribas-López P,Gutierrez-Rodriguez J,Perales-Rodríguez-De-Viguri N

    更新日期:2010-02-01 00:00:00

  • Visually guided performance of simple tasks using simulated prosthetic vision.

    abstract::Loss of photoreceptor cells is one of the major causes of blindness. Several groups are exploring the functional replacement of photoreceptors by a retinal prosthesis. The goal of this study was to simulate the vision levels that recipients of retinal prostheses with 4 x 4, 6 x 10, and 16 x 16 electrode arrays may exp...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2003.07309.x

    authors: Hayes JS,Yin VT,Piyathaisere D,Weiland JD,Humayun MS,Dagnelie G

    更新日期:2003-11-01 00:00:00

  • Controlled delivery of low-dose bone morphogenetic protein-2 using heparin-conjugated fibrin in the posterolateral lumbar fusion of rabbits.

    abstract::The heparin-conjugated fibrin (HCF) system has been developed to deliver bone morphogenetic proteins (BMPs) for a long-term period and thus enhance bone regeneration. In the present study, we tested the effectiveness of the delivery system for spinal fusion with a very low dose of BMP-2. A total of 15 rabbits underwen...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2012.01578.x

    authors: Koo KH,Lee JM,Ahn JM,Kim BS,La WG,Kim CS,Im GI

    更新日期:2013-05-01 00:00:00

  • Effect of hemodialysis on T lymphocyte subsets, con-A-activated suppressor cell activity, and interleukin-2 receptor expression on lymphocytes in chronic uremic patients.

    abstract::Effect of hemodialysis (HD) on some indices of immune response was studied in nine chronic uremics. Total lymphocyte, OKT4+, and OKT8+ cell numbers significantly decreased during the first 20 min of HD, and they were decreased till the third hour of the procedure, whereas the OKT4+/OKT8+ cell number ratio did not chan...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1989.tb02861.x

    authors: Tchórzewski H,Luciak M,Trznadel K,Majewska E,Pokoca L

    更新日期:1989-06-01 00:00:00

  • Heparin coating of small-caliber decellularized xenografts reduces macrophage infiltration and intimal hyperplasia.

    abstract::Small-caliber decellularized xenografts with surface heparin coating are known to reduce in vivo thrombogenicity. This study was performed to examine whether heparin coating on the small-caliber decellularized xenografts would reduce macrophage infiltration and intimal hyperplasia. In a rabbit model of bilateral carot...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00748.x

    authors: Cai WW,Gu YJ,Wang XN,Chen CZ

    更新日期:2009-06-01 00:00:00

  • Circulatory support for patients experiencing postcardiotomy cardiogenic shock: analysis of risk factors for death and long-term follow-up.

    abstract::Over the last 5 years, 12 patients received ventricular assist devices (VADs) while in postcardiotomy cardiogenic shock. There were 7 male and 5 female patients ranging in age from 22 to 73 years (average age, 54). Eight patients underwent surgery for valve replacements, 3 for coronary artery bypass graftings, and 1 f...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1993.tb00608.x

    authors: Murakami T,Nakayama H,Irie H,Kino K,Hisamochi K,Koomoto T,Takagaki M,Sugawara E,Senoo Y,Teramoto S

    更新日期:1993-07-01 00:00:00

  • The influence of the dialysate flow rate on hollow fiber hemodialyzer performance.

    abstract::The clearance characteristics of two sizes of hemodialyzers (0.9 m2 and 1.5 m2) from the same range of products have been studied over the dialysate flow range of 500-3,000 ml/min to establish the device's overall mass transfer resistance characteristics. The results obtained demonstrate a difference in the overall ma...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1995.tb02279.x

    authors: Allen R,Frost TH,Hoenich NA

    更新日期:1995-11-01 00:00:00

  • Cooling device for bradycardia based on Peltier element for accurate anastomosis of off-pump coronary artery bypass grafting.

    abstract::Upon introducing off-pump coronary artery bypass grafting (CABG), the indications for CABG were expanded to include patients who previously had no operative indications. For accurate anastomosis, various devices and methods have been developed. Bradycardia is easily induced by drug administration. However, this method...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2002.07087.x

    authors: Kuniyoshi Y,Koja K,Miyagi K,Shimoji M,Uezu T,Arakaki K,Yamashiro S,Mabuni K,Senaha S

    更新日期:2002-10-01 00:00:00

  • A newly designed adapter for testing an ex vivo mitral valve apparatus.

    abstract::Few instruments are currently available to test mitral valve function in an ex vivo state due to the technical difficulties involved. To investigate the native ex vivo mitral valve or prosthetic mitral valve with chordae, we developed a mitral valve adapter with an annulus suturing portion and 2 papillary muscle sutur...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06293.x

    authors: Katoh T,Ikeda N,Nishi K,Gohra H,Hamano K,Noda H,Fujimura Y,Esato K

    更新日期:1999-10-01 00:00:00

  • Development and characterization of a new stationary phase for an immunoadsorption wall.

    abstract::This study introduces a newly developed method for the formation of a stationary phase superficially embedded with immunoadsorbent, that is partially incomplete two-stage polymerization of acrylamide. Preliminary experimental studies show that binding activity of the immunoadsorbent was satisfactorily maintained after...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2005.29071.x

    authors: Yang TH

    更新日期:2005-05-01 00:00:00

  • The type of aortic cannula and membrane oxygenator affect the pulsatile waveform morphology produced by a neonate-infant cardiopulmonary bypass system in vivo.

    abstract::Although the debate still continues over the effectiveness of pulsatile versus nonpulsatile perfusion, it has been clearly proven that there are several significant physiological benefits of pulsatile perfusion during cardiopulmonary bypass (CPB) compared to nonpulsatile perfusion. However, the components of the extra...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.06017.x

    authors: Undar A,Lodge AJ,Daggett CW,Runge TM,Ungerleider RM,Calhoon JH

    更新日期:1998-08-01 00:00:00

  • Intravascular micropump for augmented liver perfusion: first in vivo experience.

    abstract::The aim of this study was to assess the in vivo performance of a new microaxial rotary blood pump developed for long-term intraportal implantation. The pump, measuring 7 mm in diameter, has a single stage impeller and is powered by a microelectric motor. The pump was implanted into the portal vein in 13 large white pi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2001.06772.x

    authors: Havlík R,Kerkhoffs W,Jiao LR,Schumacher O,Reul H,Habib N

    更新日期:2001-05-01 00:00:00