The type of aortic cannula and membrane oxygenator affect the pulsatile waveform morphology produced by a neonate-infant cardiopulmonary bypass system in vivo.

Abstract:

:Although the debate still continues over the effectiveness of pulsatile versus nonpulsatile perfusion, it has been clearly proven that there are several significant physiological benefits of pulsatile perfusion during cardiopulmonary bypass (CPB) compared to nonpulsatile perfusion. However, the components of the extracorporeal circuit have not been fully investigated regarding the quality of the pulsatility. In addition, most of these results have been gathered from adult patients, not from neonates and infants. We have designed and tested a neonate-infant pulsatile CPB system using 2 different types of 10 Fr aortic cannulas and membrane oxygenators in 3 kg piglets to evaluate the effects of these components on the pulsatile waveform produced by the system. In terms of the methods, Group 1 (Capiox 308 hollow-fiber membrane oxygenator and DLP aortic cannula with a very short 10 Fr tip [n = 2]) was subjected to a 2 h period of normothermic pulsatile CPB with a pump flow rate of 150 ml/kg/min. Data were obtained at 5, 30, 60, 90, and 120 min of CPB. In Group 2 (Capiox 308 hollow-fiber membrane oxygenator and Elecath aortic cannula with a very long 10 Fr tip [n = 7]) and Group 3 (cobe VPCML Plus flat sheet membrane oxygenator and DLP aortic cannula with a very short 10 Fr tip [n = 7]), the subjects' nasopharyngeal temperatures were reduced to 18 degrees C followed by 1 h of deep hypothermic circulatory arrest (DHCA) and then 40 min rewarming. Data were obtained during normothermic CPB in the pre- and post-DHCA periods. The criteria of pulsatility evaluations were based upon pulse pressure (between 30 and 40 mm Hg), aortic dp/dt (greater than 1000 mm Hg/s), and ejection time (less than 250 ms). The results showed that Group 1 produced flow which was significantly more pulsatile than that of the other 2 groups. Although the same oxygenator was used for Group 2, the quality of the pulsatile flow decreased when using a different aortic cannula. Group 3 did not meet any of the criteria for physiologic pulsatility. In conclusion these data suggest that in addition to a pulsatile pump, the aortic cannula and the membrane oxygenator must be chosen carefully to achieve physiologic pulsatile flow during CPB.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Undar A,Lodge AJ,Daggett CW,Runge TM,Ungerleider RM,Calhoon JH

doi

10.1046/j.1525-1594.1998.06017.x

subject

Has Abstract

pub_date

1998-08-01 00:00:00

pages

681-6

issue

8

eissn

0160-564X

issn

1525-1594

journal_volume

22

pub_type

杂志文章
  • Improved retention of endothelial cells seeded on polyurethane small-diameter vascular grafts modified by a recombinant RGD-containing protein.

    abstract::Sponge-type small-diameter vascular grafts were fabricated from a medical-grade polyurethane, Pellethane 2363-80A, by utilization of a salt casting technique. The grafts were compliance matched with a storage modulus of 0.53 +/- 0.08 MPa. The luminal surface of grafts was modified with a thin layer ( approximately 40 ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2003.07141.x

    authors: Hsu SH,Sun SH,Chen DC

    更新日期:2003-12-01 00:00:00

  • Can the human lumbar posterior columns be stimulated by transcutaneous spinal cord stimulation? A modeling study.

    abstract::Stimulation of different spinal cord segments in humans is a widely developed clinical practice for modification of pain, altered sensation, and movement. The human lumbar cord has become a target for modification of motor control by epidural and, more recently, by transcutaneous spinal cord stimulation. Posterior col...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2011.01213.x

    authors: Danner SM,Hofstoetter US,Ladenbauer J,Rattay F,Minassian K

    更新日期:2011-03-01 00:00:00

  • Oxidative Stress Increases Erythrocyte Sensitivity to Shear-Mediated Damage.

    abstract::Patients receiving mechanical circulatory support often present with heightened inflammation and free radical production associated with pre-existing conditions in addition to that which is due to blood interactions with nonbiological surfaces. The aim of this experimental laboratory study was to assess the deformabil...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12997

    authors: McNamee AP,Horobin JT,Tansley GD,Simmonds MJ

    更新日期:2018-02-01 00:00:00

  • Estimation of the native cardiac output from a rotary blood pump flow: in vitro study.

    abstract::The rotary blood pump will be an implantable left ventricular assist device (LVAD) in the near future. However, the best control method and the interrelationship between the rotary blood pump and native heart functions are unclear. An estimation was made of the native heart cardiac output from the change of an LVAD's ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.06127.x

    authors: Nakata K,Ohashi Y,Tayama E,Ohtsuka G,Takami Y,Mueller J,Glueck J,Nosé Y

    更新日期:1998-05-01 00:00:00

  • Stem damage during implantation of modular hip prostheses.

    abstract::Modular hip prostheses are commonly used today. Dedicated surgical auxiliary instrumentation is indispensable. A correct coupling between the prosthesis and the instrument is necessary to avoid damage. Based on a specific commercial design (AnCAFit, Wright Cremascoli Ortho, Toulon, France), the aim of this work was to...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2006.00261.x

    authors: Varini E,Cristofolini L,Viceconti M,Traina F

    更新日期:2006-07-01 00:00:00

  • Noninvasive average flow estimation for an implantable rotary blood pump: a new algorithm incorporating the role of blood viscosity.

    abstract::The effect of blood hematocrit (HCT) on a noninvasive flow estimation algorithm was examined in a centrifugal implantable rotary blood pump (iRBP) used for ventricular assistance. An average flow estimator, based on three parameters, input electrical power, pump speed, and HCT, was developed. Data were collected in a ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2007.00339.x

    authors: Malagutti N,Karantonis DM,Cloherty SL,Ayre PJ,Mason DG,Salamonsen RF,Lovell NH

    更新日期:2007-01-01 00:00:00

  • Hepatocyte culture between woven capillary networks: a microscopy study.

    abstract::A multi-compartment capillary membrane culture model with independently perfused three-dimensionally woven capillaries was developed for immobilization of hepatocytes in bioreactors. This enables spatial restructuring of cells and enhanced mass transfer performance with more efficient oxygenation and metabolite exchan...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1994.tb02181.x

    authors: Gerlach J,Schnoy N,Smith MD,Neuhaus P

    更新日期:1994-03-01 00:00:00

  • Proof of principle of a novel co-pulsating intra-ventricular membrane pump.

    abstract::In this proof of principle study, we investigated the effectiveness and safety of hemodynamic support with the Intra-Ventricular Membrane Pump (IVMP). The IVMP was implanted into the apex of the left ventricle. Hemodynamic assessment was performed in six ex vivo beating porcine hearts (PhysioHeart platform). The cardi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13757

    authors: van Dort DIM,Thannhauser J,Gommans FDH,Ten Cate TJ,Duncker DJ,Suryapranata H,Morshuis WJ,Geuzebroek GSC

    更新日期:2020-12-01 00:00:00

  • Changes in albumin/platelet interaction with an artificial surface--due to a antibiotics, pyridoxal phosphate, and lymphocytes.

    abstract::Protein adsorption and platelet adhesion are two important biological processes arising at the blood prosthetic interface. The effect of certain antibiotics, namely, neomycin, gentamicin, ampicillin, penicillin-G, and streptomycin to modulate the albumin polycarbonate surface interaction was investigated using 125I al...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1988.tb02747.x

    authors: Chandy T,Sharma CP

    更新日期:1988-04-01 00:00:00

  • Totally Endoscopic Robotic-Assisted Cardiac Surgery in Children.

    abstract::Robotic surgery for intracardiac pathologies in children is relatively uncommon. This study presents our initial experience with robotic-assisted cardiac surgery in children. We also present the feasibility and safety of robotic surgery in children. From May 2013 to June 2018, 30 children underwent totally endoscopic ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13357

    authors: Onan B,Aydin U,Kadirogullari E,Onan IS,Sen O

    更新日期:2019-04-01 00:00:00

  • Bacterial and fungal infection in neonates undergoing venoarterial extracorporeal membrane oxygenation: an analysis of the registry data of the extracorporeal life support organization.

    abstract::A review and analysis of 5,001 neonatal venoarterial (VA) extracorporeal membrane oxygenation (ECMO) cases showed that bacterial and fungal infection occurred in 147 (2.9%) and 26 (0.6%) patients, respectively, with an overall incidence of 3.5%. Bivariate analysis was used to compare infected infants with controls, ba...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1996.tb04428.x

    authors: Douglass BH,Keenan AL,Purohit DM

    更新日期:1996-03-01 00:00:00

  • A novel in vitro assessment of tissue valve calcification by a continuous flow type method.

    abstract::A dynamic flow type testing to study calcification was self-designed to investigate calcification in bioprosthetic heart valves. The apparatus consists of a container into which leaflets from a porcine aortic valve are placed, a chamber that contains calcium solution, and a peristaltic pump that provides a continuous ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06482-2.x

    authors: Park JC,Hwang YS,Han DW,Suh H

    更新日期:2000-02-01 00:00:00

  • Comparison of Centrifugal and Roller Pump Hemolysis Rates at Low Flow.

    abstract::We compared in vitro rates of hemolysis for a recently developed centrifugal pump with a conventional roller pump (10-10-00; Stöckert, Munich, Germany). Flow rates of 0.3 L/min and 1 L/min and a pressure of 200 mm Hg were chosen to simulate conditions during neonatal extracorporeal membrane oxygenation (ECMO). There w...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1996.tb04485.x

    authors: Moon YS,Ohtsubo S,Gomez MR,Moon JK,Nose Y

    更新日期:1996-05-01 00:00:00

  • Selective removal of anti-acetylcholine receptor antibodies and IgG in vitro with an immunoadsorbent containing immobilized sulfathiazole.

    abstract::Adsorption therapy, which treats the autoimmune disease by the selective removal of pathogenic substances from the blood, is an active subject. In this therapy, bioactive molecules such as antigen, antibodies and protein A are usually used as affinity-ligands. The disadvantages of using these substances as affinity-li...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1990.tb02977.x

    authors: Yamamoto Y,Sameshima T,Akaike T

    更新日期:1990-10-01 00:00:00

  • Immunologic studies of hollow-fiber dialyzer extracts.

    abstract::Testing failed to detect free isocyanates in dialyzer rinses or significant levels of immunoglobulin E antibodies to isocyanate-protein conjugates in the serum of individuals reacting during hemodialysis with dialyzers containing Cuprophan membranes. Extended immunization of rabbits with Limulus lysate-reactive materi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1984.tb04298.x

    authors: Butcher BT,Reed MA,O'Neil CE,Leech S,Pearson FC

    更新日期:1984-08-01 00:00:00

  • High cell-density culture system of hepatocytes entrapped in a three-dimensional hollow fiber module with collagen gel.

    abstract::A compact three-dimensional (3D) module is needed for hepatocyte culture in order to develop an effective hybrid artificial liver system that can retain hepatocellular structure and differentiated functions. We treated the 3D module with collagen gel to entrap rat hepatocytes. This method yielded a high hepatocellular...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1995.tb02310.x

    authors: Takeshita K,Ishibashi H,Suzuki M,Yamamoto T,Akaike T,Kodama M

    更新日期:1995-02-01 00:00:00

  • General planning of an artificial organ center.

    abstract::There is an increasing need for research and development centers to deal with design and evaluation of organ replacement systems, the improvement of older devices, and the study of biocompatibility problems. Special attention, in this article, is focused on the determinant role of the background of the investigators i...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1989.tb01579.x

    authors: Vanholder R,Ringoir S

    更新日期:1989-12-01 00:00:00

  • Acellular Endocardium as a Novel Biomaterial for the Intima of Tissue-Engineered Small-Caliber Vascular Grafts.

    abstract::We aimed to investigate whether acellular endocardium can be used as a useful biomaterial for the intima of engineered small-caliber vascular grafts. Fresh endocardium was harvested from the swine left atrium and was decellularized by digestion with the decellularization solution of Triton X-100 and SDS containing DNa...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12814

    authors: Wang F,Guan X,Wu T,Qiao J,Han Z,Wu J,Yu X,You Q

    更新日期:2016-12-01 00:00:00

  • The mechanics of spiral flow: Enhanced washout and transport.

    abstract::Spiral/helical forms of blood flow have been observed in large arteries of the cardiovascular system, but their benefits remain underappreciated. Spiral flow has been postulated to improve near-wall washout, promoting anti-atherothrombotic conditions. This research aims to study the washout characteristics of spiral f...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13520

    authors: Huang Zhang P,Tkatch C,Newman R,Grimme W,Vainchtein D,Kresh JY

    更新日期:2019-12-01 00:00:00

  • Evaluation of double filtration plasmapheresis, thermofiltration, and low-density lipoprotein adsorptive methods by crossover test in the treatment of familial hypercholesterolemia patients.

    abstract::A comparative assessment has been made regarding efficacy and safety of the double filtration plasmapheresis (DFPP), thermofiltration (TFPP), and low-density lipoprotein (LDL) adsorptive (PA) methods by making a crossover test on heterozygous familial hypercholesterolemia patients. Treatments by DFPP, TFPP (secondary ...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1525-1594.1996.tb04448.x

    authors: Suzuki M,Yamane S,Matsugane T,Nobuto T,Azuma N,Nishide T,Shinomiya M,Saito K,Sasaki N,Nosé Y

    更新日期:1996-04-01 00:00:00

  • A human lymph node in vitro--challenges and progress.

    abstract::Extracorporeal human lymphatic organs are expected to be excellent tools in the study of human molecular and cellular bases of the immunologic balance and tissue harmony. A rational approach and process to design a device and a procedure to recreate the human lymph node environment in vitro is described with emphasis ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2006.00303.x

    authors: Giese C,Demmler CD,Ammer R,Hartmann S,Lubitz A,Miller L,Müller R,Marx U

    更新日期:2006-10-01 00:00:00

  • Development of a flow estimation and control system of an implantable centrifugal blood pump for circulatory assist.

    abstract::A bypass flow rate estimation and control system (BECS) for an implantable centrifugal blood pump (ICBP) has been developed in our institute. The estimated flow rate (EF) of the ICBP was derived from the electric power consumption, the rotating speed of a motor, and the blood viscosity presumed by the hematocrit and b...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.06130.x

    authors: Wakisaka Y,Okuzono Y,Taenaka Y,Chikanari K,Endo S,Masuzawa T,Takano H

    更新日期:1998-06-01 00:00:00

  • A hemoglobin-based multifunctional therapeutic: polynitroxylated pegylated hemoglobin.

    abstract::Polynitroxylated pegylated hemoglobin (PNPH) as a multifunctional therapeutic takes advantage of the ability of hemoglobin (Hb) to transport oxygen, the antioxidative stress activities from the redox coupling of nitroxide and heme iron, and the hypercolloid properties of pegylation. The published preclinical data demo...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2011.01307.x

    authors: Hsia CJ,Ma L

    更新日期:2012-02-01 00:00:00

  • Binding of antithrombin to immobilized heparin under varying flow conditions.

    abstract::Rheologic factors are likely to influence the balance between thrombotic and antithrombotic forces at the level of the vascular wall. In this study, the effects of flow-velocity/wall shear stress on the interaction of antithrombin (AT) with surface-immobilized heparin were investigated. The binding of AT to low-affini...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors: Pasche B,Elgue G,Olsson P,Riesenfeld J,Rasmuson A

    更新日期:1991-12-01 00:00:00

  • Evaluation of cardiac beat synchronization control for a rotary blood pump on valvular regurgitation with a mathematical model.

    abstract::We have studied the cardiac beat synchronization (CBS) control for a rotary blood pump (RBP) and revealed that it can promote pulsatility and reduce cardiac load. Besides, patients with LVAD support sometimes suffer from aortic and mitral regurgitation (AR and MR). A control method for the RBP should be validated in w...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13795

    authors: Ogawa D,Kobayashi S,Yamazaki K,Motomura T,Nishimura T,Shimamura J,Tsukiya T,Mizuno T,Takewa Y,Tatsumi E,Nishinaka T

    更新日期:2020-08-19 00:00:00

  • Melt Electrospun Bilayered Scaffolds for Tissue Integration of a Suture-Less Inflow Cannula for Rotary Blood Pumps.

    abstract::Implantation of left ventricular assist devices typically requires cardiopulmonary bypass support, which is associated with postoperative complications. A novel suture-less inflow cannula, which can be implanted without bypass, uses mild myocardial compression to seal the interface, however, this may lead to necrosis ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13018

    authors: Liao S,Theodoropoulos C,Blackwood KA,Woodruff MA,Gregory SD

    更新日期:2018-05-01 00:00:00

  • Usability and safety of ventricular assist devices: human factors and design aspects.

    abstract::The purpose of this study was the investigation of the usability and ergonomics of ventricular assist devices (VADs) in everyday usage. Patients with four different VAD types were observed. After implantation, instruction, and discharge from the hospital, the patients returned on a regular basis to the outpatient clin...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00844.x

    authors: Geidl L,Zrunek P,Deckert Z,Zimpfer D,Sandner S,Wieselthaler G,Schima H

    更新日期:2009-09-01 00:00:00

  • Phosphorylcholine and poly(D,L-lactic acid) containing copolymers as substrates for cell adhesion.

    abstract::Fibroblast cell culture was performed to evaluate cell adhesion and cell morphology on novel hydrolyzable copolymers composed of poly(D,L-lactic acid) (PDLA) macromonomer, 2-methacryloyloxyethyl phosphorylcholine (MPC), and n-butyl methacrylate. The copolymers were used as cell culture materials for regulating the int...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2003.07015.x

    authors: Watanabe J,Ishihara K

    更新日期:2003-03-01 00:00:00

  • Selective inhibition of resistance to hemopoietic allografts but not rejection to a natural killer cell sensitive tumor in transgenic mice for granulocyte colony stimulating factor.

    abstract::Transplanted allogeneic marrow grafts often fail to engraft in a lethally irradiated host. Resistance to hemopoietic allograft is a complexed phenomenon involving multiple components. To study the involvement of a hemopoietic cytokine, which was known to play a role for stem cell function, we established lines of mice...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1996.tb04563.x

    authors: Kokai Y,Kimura H,Matsuura A,Fujimoto J

    更新日期:1996-08-01 00:00:00

  • Angiographic and pathological studies on regression of coronary atherosclerosis of FH patients who received LDL-apheresis treatment.

    abstract::We report on the most recent data confirming the angiographic and pathological efficacy of LDL-apheresis for coronary atherosclerosis of a familial hypercholesterolemia (FH) patient using collected data of a large number of cases and especially of one autopsy case. Changes in coronary artery stenosis have been assesse...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1992.tb00289.x

    authors: Koga N,Iwata Y,Yamamoto A