Bacterial and fungal infection in neonates undergoing venoarterial extracorporeal membrane oxygenation: an analysis of the registry data of the extracorporeal life support organization.

Abstract:

:A review and analysis of 5,001 neonatal venoarterial (VA) extracorporeal membrane oxygenation (ECMO) cases showed that bacterial and fungal infection occurred in 147 (2.9%) and 26 (0.6%) patients, respectively, with an overall incidence of 3.5%. Bivariate analysis was used to compare infected infants with controls, bacterial versus fungal groups, and bacterial subgroups with respect to patient demographics, primary diagnosis, mechanical complications, patient complications, duration of the ECMO course, and hospital mortality. Logistic regression models were constructed using variables that were statistically significant from the bivariate comparisons. Variables that remained significant after multivariate analysis included primary diagnosis of pneumonia/sepsis, mechanical complications of oxygenator failure, rupture of raceway or tubing, clots, and patient complications of hypertension and hyperbilirubinemia. The infection group had significantly longer mean total hours on bypass and higher hospital mortality. Infants with fungal infection had a significantly higher hospital mortality rate compared with those with bacterial infection. We conclude that infection during ECMO, especially fungal infection, carries an increased risk of hospital mortality and that mechanical complications are associated with an increased risk of infection, Key Words: Extracorporeal membrane oxygenation-Nosocomial-Bacterial infection-Fungal infection-Extracorporeal membrane oxygenation outcome.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Douglass BH,Keenan AL,Purohit DM

doi

10.1111/j.1525-1594.1996.tb04428.x

subject

Has Abstract

pub_date

1996-03-01 00:00:00

pages

202-8

issue

3

eissn

0160-564X

issn

1525-1594

journal_volume

20

pub_type

杂志文章
  • Investigation of the inherent left-right flow balancing of rotary total artificial hearts by means of a resistance box.

    abstract::With the incidence of end-stage heart failure steadily increasing, the need for a practical total artificial heart (TAH) has never been greater. Continuous flow TAHs (CFTAH) are being developed using rotary blood pumps (RBPs), leveraging their small size, mechanical simplicity, and excellent durability. To completely ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13631

    authors: Nestler F,Timms DL,Stevens M,Bradley AP,Wilson SJ,Kleinheyer M,Lovell N,Frazier OH,Cohn WE

    更新日期:2020-06-01 00:00:00

  • Measurement of the closing behavior of the björk-shiley monoleaflet mechanical heart valve with an electrohydraulic total artificial heart.

    abstract::When cavitation occurs near a material surface of a mechanical heart valve (MHV), pits on the surface of the MHV and hemolysis are caused. Therefore, it is very important to investigate the possibility of the occurrence of cavitation in an MHV. To study the possibility of cavitation occurrence in a 25 mm Björk-Shiley ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2003.06981.x

    authors: Lee H,Tsukiya T,Homma A,Taenaka Y,Tatsumi E,Takano H

    更新日期:2003-08-01 00:00:00

  • Assessment of five interleukins in human synovial fluid as possible markers for aseptic loosening of hip arthroplasty.

    abstract::One of the most important factors that seems to be involved in total hip replacement is periprosthetic osteolysis. As it is well documented that several interleukins (ILs) are triggered in periprosthetic osteolysis, this article investigates the role of five ILs in primary and replacement total hip arthroplasty, under...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00736.x

    authors: Beraudi A,Stea S,Cremonini S,Visentin M,Toni A

    更新日期:2009-07-01 00:00:00

  • Coronary artery anatomy of the goat.

    abstract::The coronary arteries of the goat heart were studied using angiographic techniques and molds of the coronary vessel trees. Blood supplies to the left and right ventricles, interventricular septum, atrioventricular node, and apex of the caprine heart were studied. The goat possesses a left dominant pattern of coronary ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1983.tb04192.x

    authors: Lipovetsky G,Fenoglio JJ,Gieger M,Srinivasan MR,Dobelle WH

    更新日期:1983-05-01 00:00:00

  • The analysis of driving mode influence on energy dissipation in pneumatic artificial heart chambers.

    abstract::The energy dissipated in blood or on a total artificial heart (TAH) chamber's elements directly or indirectly decreases the biological or technical safety of the TAH's work. The energetic analysis of the Polish total artificial heart (POLTAH) external work with the objective of estimating the valve and membrane roles ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.05074.x

    authors: Nawrat Z,Malota Z

    更新日期:1998-10-01 00:00:00

  • Intra-Aortic Balloon Pump Support in the Isolated Beating Porcine Heart in Nonischemic and Ischemic Pump Failure.

    abstract::The blood pressure changes induced by the intra-aortic balloon pump (IABP) are expected to create clinical improvement in terms of coronary perfusion and myocardial oxygen consumption. However, the measured effects reported in literature are inconsistent. The aim of this study was to investigate the influence of ische...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12470

    authors: Schampaert S,van Nunen LX,Pijls NH,Rutten MC,van Tuijl S,van de Vosse FN,van 't Veer M

    更新日期:2015-11-01 00:00:00

  • Extracorporeal Life Support in Out-of-Hospital Refractory Cardiac Arrest.

    abstract::Out-of-Hospital refractory Cardiac Arrest (OHrCA) has a mortality rate between 90 and 95%. Since 2009, French medical academic societies have recommended the use of extracorporeal life support (ECLS) for OHrCA. According to these guidelines, patients were eligible for ECLS support if vital signs were still present dur...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12655

    authors: Rousse N,Robin E,Juthier F,Hysi I,Banfi C,Al Ibrahim M,Coadou H,Goldstein P,Wiel E,Vincentelli A

    更新日期:2016-09-01 00:00:00

  • A bedside micromethod for the determination of total carbon dioxide in biological fluids.

    abstract::The quality control of bicarbonate hemodialysis requires the determination of TCO2, either in blood or in dialysate. The use of the M + D TCO2 kit, a bedside micromethod, gave the authors an economical and reliable solution to this problem. ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1985.tb04404.x

    authors: Canaud B,Araujo A,Nguyen QV,Flavier JL,Mion C

    更新日期:1985-11-01 00:00:00

  • Myointimal hyperplasia: pathogenesis and implications. 1. In vitro characteristics.

    abstract::Myointimal hyperplasia (MIH) is an arterial wall smooth muscle cell (SMC) proliferative disorder. This process is responsible for a significant number of early and long-term arterial reconstructive and graft failures. Histopathologically, this process is characterized by a proliferation of SMC in the intima of traumat...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1111/j.1525-1594.1991.tb00758.x

    authors: Painter TA

    更新日期:1991-02-01 00:00:00

  • Transient rise in serum soluble Fas (APO-1/CD95) in patients undergoing cardiac surgery.

    abstract::The Fas molecule, also designated APO-1/CD95, belongs to the tumor necrosis factor (TNF) receptor family. It is a widely expressed membrane-anchored protein that induces apoptosis by Fas/Fas ligand (Fas-L) mediation. It was reported that Fas-mediated apoptosis plays an important role in regulation of the immune system...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06591.x

    authors: Kawahito K,Misawa Y,Fuse K

    更新日期:2000-08-01 00:00:00

  • Development of a composite degradable/nondegradable tissue-engineered vascular graft.

    abstract::The present study aimed to determine the feasibility of constructing a reinforced autologous vascular graft by combining the advantages of fibrin gel as an autologous cell carrier material with the inherent mechanical strength of an integrated mesh structure. It was hypothesized that the mesh and dynamic culture condi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00601.x

    authors: Tschoeke B,Flanagan TC,Cornelissen A,Koch S,Roehl A,Sriharwoko M,Sachweh JS,Gries T,Schmitz-Rode T,Jockenhoevel S

    更新日期:2008-10-01 00:00:00

  • Remote monitoring of left ventricular assist device parameters after HeartAssist-5 implantation.

    abstract::Although several left ventricular assist devices (LVADs) have been used widely, remote monitoring of LVAD parameters has been available only recently. We present our remote monitoring experience with an axial-flow LVAD (HeartAssist-5, MicroMed Cardiovascular, Inc., Houston, TX, USA). Five consecutive patients who were...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12144

    authors: Pektok E,Demirozu ZT,Arat N,Yildiz O,Oklu E,Eker D,Ece F,Ciftci C,Yazicioglu N,Bayindir O,Kucukaksu DS

    更新日期:2013-09-01 00:00:00

  • Combination of plasma exchange and continuous hemofiltration as temporary metabolic support for patients with acute liver failure.

    abstract::The combination of plasma exchange and continuous hemofiltration was applied to patients with acute liver failure, and its clinically advantageous effects were evaluated. This procedure was found to be a powerful approach in decreasing patient morbidity; however, the effect was temporary and the patients finally died....

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1994.tb02217.x

    authors: Matsubara S

    更新日期:1994-05-01 00:00:00

  • Significant left ventricular unloading with transaortic catheter venting during venoarterial bypass.

    abstract::Insufficient unloading of the left ventricle with blood stagnation is a main cause of unsuccessful left ventricular (LV) recovery during percutaneous cardiopulmonary support (PCPS). The purpose of this investigation was to evaluate the effectiveness of transaortic catheter venting (TACV) for LV unloading. Six adult mo...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb03744.x

    authors: Shibuya M,Kitamura M,Kurihara H,Kikuchi C,Endo M,Koyanagi H

    更新日期:1997-07-01 00:00:00

  • Computational simulation of a non-newtonian model of the blood separation process.

    abstract::The aim of this work is to construct a computational fluid dynamics model capable of simulating the transient non-Newtonian process of apheresis. A Lagrangian-Eulerian model has been developed which tracks the blood particles within a two-dimensional flow configuration. Within the Eulerian method, the fluid mass and m...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2005.00164.x

    authors: De Gruttola S,Boomsma K,Poulikakos D

    更新日期:2005-12-01 00:00:00

  • Renal osteodystrophy in dialysis patients: diagnosis and treatment.

    abstract::This article reviews the clinical, biological, radiological, and pathological procedures and their respective indications for the practical diagnosis of the following various histological patterns of renal osteodystrophy: osteitis fibrosa due to parathyroid hormone (PTH) hypersecretion: osteomalacia or rickets due to ...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1046/j.1525-1594.1998.06198.x

    authors: Fournier A,Oprisiu R,Hottelart C,Yverneau PH,Ghazali A,Atik A,Hedri H,Said S,Sechet A,Rasolombololona M,Abighanem O,Sarraj A,El Esper N,Moriniere P,Boudailliez B,Westeel PF,Achard JM,Pruna A

    更新日期:1998-07-01 00:00:00

  • Aging adversely impacts biological properties of human bone marrow-derived mesenchymal stem cells: implications for tissue engineering heart valve construction.

    abstract::Our aim was to study the aging effects on the in vitro biological properties of bone marrow-derived mesenchymal stem cells (BMSCs) for construction of tissue-engineered heart valves. BMSCs were taken from teenagers with congenital heart diseases, and middle-aged and elderly patients with valvular diseases. Proliferati...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00824.x

    authors: Xin Y,Wang YM,Zhang H,Li J,Wang W,Wei YJ,Hu SS

    更新日期:2010-03-01 00:00:00

  • Acellular Endocardium as a Novel Biomaterial for the Intima of Tissue-Engineered Small-Caliber Vascular Grafts.

    abstract::We aimed to investigate whether acellular endocardium can be used as a useful biomaterial for the intima of engineered small-caliber vascular grafts. Fresh endocardium was harvested from the swine left atrium and was decellularized by digestion with the decellularization solution of Triton X-100 and SDS containing DNa...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12814

    authors: Wang F,Guan X,Wu T,Qiao J,Han Z,Wu J,Yu X,You Q

    更新日期:2016-12-01 00:00:00

  • Long-term performance of homograft and autograft valves.

    abstract::Five hundred and eighty homograft valves have been inserted into the aortic position as isolated valve replacements, and followed up for 7--14 years. After ten years 90% of frozen homografts, 80% of autografts and 70% of freeze-dried homografts were free of valve-related death. There was only one embolism reported giv...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1980.tb03894.x

    authors: Bodnar E,Wain WH,Martelli V,Ross DN

    更新日期:1980-02-01 00:00:00

  • Glucose-insulin kinetics of a bioartificial pancreas made of an AN69 hydrogel hollow fiber containing porcine islets and implanted in diabetic mice.

    abstract::The goal of this study was to determine whether porcine islets encapsulated in hollow fibers made of AN69 copolymer can correct hyperglycemia in diabetic mice and provide normal tolerance to a glucose challenge. In vitro perifusion of hollow fibers demonstrated the rapid kinetics of insulin release in response to gluc...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.05087.x

    authors: Delaunay C,Darquy S,Honiger J,Capron F,Rouault C,Reach G

    更新日期:1998-04-01 00:00:00

  • Hypertension and end-stage renal disease in the developing world.

    abstract::Hypertension is an important primary etiology of end-stage renal disease as well as a major factor responsible for progression of renal disease due to other causes. Multiple genetic and environmental factors are responsible for the variable prevalence of hypertension in various parts of the world. Although the frequen...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2002.07067.x

    authors: El-Khashab O

    更新日期:2002-09-01 00:00:00

  • Nonsymmetric leaflet motion of St. Jude Medical mitral valves simulated with a computer-controlled hydraulic mock circulator.

    abstract::Since the introduction of high-performance prosthetic heart valves, particularly bileaflet valves and monoleaflet valves with larger opening angles, we have observed in vivo complex leaflet motion which has not been experimentally confirmed yet. We developed a computer-controlled hydraulic mock circulator to study the...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb00373.x

    authors: Ohta Y,Okamoto K,Sonderegger M,Dohi T,Matsumoto H,Horiuchi T

    更新日期:1997-04-01 00:00:00

  • Clinical long-term results of vascular prosthesis sealed with fragmented autologous adipose tissue.

    abstract::Tissue engineering can improve the former limitations of artificial organs. This article reports the long-term clinical results of grafts constructed with fragmented autologous adipose tissue. We did a retrospective analysis of a series of 53 patients with lower leg ischemia that received 69 fragmented adipose tissue ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2001.025003218.x

    authors: Karube N,Soma T,Noishiki Y,Yamazaki I,Kosuge T,Ichikawa Y,Takanashi Y

    更新日期:2001-03-01 00:00:00

  • Hybrid assembly of metal head and femoral stem from different manufacturers during isolated acetabular revision.

    abstract::During revision of a failed acetabular component with well-fixed antiquated femoral stem, the same variant of metal head is usually not available in the inventory production. We gathered the stems retrieved from revision surgeries and tried to reassemble with the commercially available femoral heads. This study report...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2010.01015.x

    authors: Chen CF,Chen WM,Yang CT,Huang CK,Chen TH

    更新日期:2010-08-01 00:00:00

  • Anticoagulation with fondaparinux for hemodiafiltration in patients with heparin-induced thrombocytopenia: dose-finding study and safety evaluation.

    abstract::The optimal anticoagulation regimen for hemodialysis (HD) in patients with heparin-induced thrombocytopenia (HIT) has not been defined. Hemodiafiltration (HDF) adds a large convective component to HD, thereby changing the pharmacokinetics of most anticoagulants. Data on coagulation regimens for HDF are scant. We there...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12002

    authors: Mahieu E,Claes K,Jacquemin M,Evenepoel P,Op De Beek K,Bogaert AM,Kuypers D,Verhamme P,Meijers B

    更新日期:2013-05-01 00:00:00

  • Effect of variation in systemic blood flow on plasma TNF-alpha in a pig model with left ventricular assist device.

    abstract::Tumor necrosis factor-alpha (TNF-alpha) release has been implicated in a sepsis-like syndrome following cardiopulmonary bypass (CPB). This also may be important in patients who have had a left ventricular assist device (LVAD) implanted. This report investigates the effect of reducing systemic blood flow on hemodynamic...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2001.025002146.x

    authors: Uozaki Y,Dihmis WC,Yamauchi H,Moczar M,Miyama M,Pasteau F,Tixier D,Bambang SL,Loisance DY

    更新日期:2001-02-01 00:00:00

  • Development of a flow estimation and control system of an implantable centrifugal blood pump for circulatory assist.

    abstract::A bypass flow rate estimation and control system (BECS) for an implantable centrifugal blood pump (ICBP) has been developed in our institute. The estimated flow rate (EF) of the ICBP was derived from the electric power consumption, the rotating speed of a motor, and the blood viscosity presumed by the hematocrit and b...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.06130.x

    authors: Wakisaka Y,Okuzono Y,Taenaka Y,Chikanari K,Endo S,Masuzawa T,Takano H

    更新日期:1998-06-01 00:00:00

  • Effects of inhaled nitric oxide on postoperative pulmonary circulation in patients with congenital heart disease.

    abstract::We studied 22 patients with residual pulmonary hypertension or symptoms of postoperative pulmonary hypertensive crisis. They received low-dose inhalation (10 ppm) of nitric oxide (NO), a selective pulmonary vasodilator, after total correction for congenital heart anomalies. Fifteen minutes of NO inhalation improved th...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1525-1594.1997.tb00692.x

    authors: Matsui J,Yahagi N,Kumon K,Hayashi H,Watanabe Y,Haruna M,Tanigami H,Yagihara T,Takamoto S,Kamiya T

    更新日期:1997-01-01 00:00:00

  • Development and clinical assay of the BCM ventricular assist device.

    abstract::The development of a ventricular assist device is depicted. The seven subprograms that make up the project are described briefly. Results obtained during the clinical assay showed that the new design of the input cannula working as a false auricle provides better efficiency, as well as a certain level of autoregulatio...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1994.tb03364.x

    authors: del Cañizo JF,Antoranz JC,Desco MM,Alvarez-Valdivielso JM,Fernandez-Caleya D,López M,Garcia-Barreno P,Duarte J

    更新日期:1994-07-01 00:00:00

  • A Pseudo-One Compartment Model of Phosphorus Kinetics During Hemodialysis: Further Supporting Evidence.

    abstract::A pseudo-one compartment model has been proposed to describe phosphorus kinetics during hemodialysis and the immediate post-dialysis period. This model assumes that phosphorus mobilization from tissues is proportional to the difference between the pre-dialysis serum concentration (a constant) and the instantaneous ser...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12897

    authors: Leypoldt JK,Agar BU,Cheung AK,Bernardo AA

    更新日期:2017-11-01 00:00:00