Glucose-insulin kinetics of a bioartificial pancreas made of an AN69 hydrogel hollow fiber containing porcine islets and implanted in diabetic mice.

Abstract:

:The goal of this study was to determine whether porcine islets encapsulated in hollow fibers made of AN69 copolymer can correct hyperglycemia in diabetic mice and provide normal tolerance to a glucose challenge. In vitro perifusion of hollow fibers demonstrated the rapid kinetics of insulin release in response to glucose. Two fibers containing islets were transplanted into the peritoneal cavity of each of 17 streptozotocin induced diabetic mice. In 11 mice, diabetes was reversed within 3 days with plasma glucose levels decreasing from 19.7 +/- 0.9 (mean +/- SEM) before implantation to 10.9 +/- 0.8 mmol/L. Intraperitoneal glucose tolerance tests were performed in transplanted (n = 7), nondiabetic (n = 15), and diabetic mice (n = 6). A normal glucose pattern was observed in the transplanted diabetic mice. This was achieved in the presence of plasma insulin levels lower than those observed in control nondiabetic mice, suggesting the presence of a state of hypersensitivity to insulin, which was demonstrated in this model by exogenous insulin tolerance tests. In conclusion, encapsulation of islets suspended in ultraculture medium in biocompatible membranes of AN69 can provide xenograft survival, and complete normalization of glucose tolerance can be achieved.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Delaunay C,Darquy S,Honiger J,Capron F,Rouault C,Reach G

doi

10.1046/j.1525-1594.1998.05087.x

subject

Has Abstract

pub_date

1998-04-01 00:00:00

pages

291-9

issue

4

eissn

0160-564X

issn

1525-1594

journal_volume

22

pub_type

杂志文章
  • Atrial versus ventricular cannulation for a rotary ventricular assist device.

    abstract::The ventricular assist device inflow cannulation site is the primary interface between the device and the patient. Connecting these cannulae to either atria or ventricles induces major changes in flow dynamics; however, there are little data available on precise quantification of these changes. The objective of this i...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2010.01093.x

    authors: Timms D,Gregory S,Hsu PL,Thomson B,Pearcy M,McNeil K,Fraser J,Steinseifer U

    更新日期:2010-09-01 00:00:00

  • Adverse events of subcutaneous recombinant human erythropoietin therapy: results of a controlled multicenter European study.

    abstract::In a controlled European multicenter study, clinical tolerance of subcutaneously administered recombinant human erythropoietin (rh-EPO) therapy and its influence on the course of illness in 362 hemodialyzed patients (162 males, 200 females) from 16 European dialysis centers was studied. Of these, 181 patients served a...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章,多中心研究,随机对照试验

    doi:10.1111/j.1525-1594.1993.tb00571.x

    authors: Klinkmann H,Wieczorek L,Scigalla P

    更新日期:1993-04-01 00:00:00

  • Effects of scaling on centrifugal blood pumps.

    abstract::Experimental studies on the effects of scaling on the performance of centrifugal blood pumps were conducted in a closed-loop test rig. For the prototype, eight different impellers of the same outer diameter of 25 mm were tested at 1,500, 2,000, and 2,500 revolutions per minute (rpm) using blood analog as fluid medium....

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2002.07119.x

    authors: Wong YW,Chan WK,Yu SC,Chua LP

    更新日期:2002-11-01 00:00:00

  • Hemodynamic evaluation of a new left ventricular assist device: an integrated cardioassist catheter as a pulsatile left ventricle-femoral artery bypass.

    abstract::We developed a new left ventricular (LV) assist catheter (transaortic valve from LV to femoral artery) that is implemented percutaneously and exerted as a synchronous pulsatile partial LV flow support with conventional intraaortic balloon pump (IABP) driving system and centrifugal pump system. We investigated whether ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1992.tb00311.x

    authors: Ide H,Yamaguchi A,Ino T,Matsumoto H,Fujimasa I

    更新日期:1992-06-01 00:00:00

  • The impact of pump speed and inlet cannulation site on left ventricular unloading with a rotary blood pump.

    abstract:BACKGROUND:Ventricular assist devices are gaining ground in the therapeutic treatment of chronic heart failure. These devices are sometimes used as a bridge to recovery by unloading the left ventricle (LV) and restoring its function. It is therefore important to preserve the heart muscle and apply less invasive implant...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2004.07374.x

    authors: Vandenberghe S,Nishida T,Segers P,Meyns B,Verdonck P

    更新日期:2004-07-01 00:00:00

  • Long-term performance of homograft and autograft valves.

    abstract::Five hundred and eighty homograft valves have been inserted into the aortic position as isolated valve replacements, and followed up for 7--14 years. After ten years 90% of frozen homografts, 80% of autografts and 70% of freeze-dried homografts were free of valve-related death. There was only one embolism reported giv...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1980.tb03894.x

    authors: Bodnar E,Wain WH,Martelli V,Ross DN

    更新日期:1980-02-01 00:00:00

  • Extracorporeal life support during and after bilateral sequential lung transplantation in patients with pulmonary artery hypertension.

    abstract::The use of extracorporeal membrane oxygenator instead of standard cardiopulmonary bypass during lung transplantation is debatable. Moreover, recently, the concept of prolonged postoperative extracorporeal membrane oxygenator (ECMO) support has been introduced in many transplant centers to prevent primary graft dysfunc...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13628

    authors: Dell'Amore A,Campisi A,Congiu S,Mazzarra S,Pastore S,Dolci G,Baiocchi M,Frascaroli G

    更新日期:2020-06-01 00:00:00

  • A hemoglobin-based multifunctional therapeutic: polynitroxylated pegylated hemoglobin.

    abstract::Polynitroxylated pegylated hemoglobin (PNPH) as a multifunctional therapeutic takes advantage of the ability of hemoglobin (Hb) to transport oxygen, the antioxidative stress activities from the redox coupling of nitroxide and heme iron, and the hypercolloid properties of pegylation. The published preclinical data demo...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2011.01307.x

    authors: Hsia CJ,Ma L

    更新日期:2012-02-01 00:00:00

  • Cell adhesive and antifouling polyvinyl chloride surfaces via wet chemical modification.

    abstract::Polyvinyl chloride (PVC) is one of the most frequently used polymers for the manufacturing of medical devices. Limitations for its usage are based upon unfavorable surface properties of the polymer including its hydrophobicity and lack of functionalities in order to increase its versatility. To address this issue, wet...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2012.01462.x

    authors: Gabriel M,Strand D,Vahl CF

    更新日期:2012-09-01 00:00:00

  • In Vitro Evaluation of Inflow Cannula Fixation Techniques in Left Ventricular Assist Device Surgery.

    abstract::The therapy of terminal heart failure with left ventricular assist devices has become a standard in cardiac surgery. Yet the surgical implantation technique is not standardized and differs from center to center. Complications associated with left ventricular assist device (LVAD) inflow cannula placement are thrombosis...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12735

    authors: Hanke JS,Krabatsch T,Rojas SV,Deniz E,Ismail I,Martens A,Shrestha M,Haverich A,Netuka I,Schmitto JD

    更新日期:2017-03-01 00:00:00

  • Artificial cells with emphasis on cell encapsulation of genetically engineered cells.

    abstract::Artificial cells are prepared in the laboratory for medical and biotechnological applications. Encapsulated cells are being studied for the treatment of diabetes, liver failure, and other conditions. More recently, there have been extensive studies into the use of encapsulated genetically engineered cells for gene the...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.06243.x

    authors: Chang TM

    更新日期:1998-11-01 00:00:00

  • Prolonged left ventricular dysfunction induced by sequential multifocal ischemic infarcts in dogs.

    abstract::A method of creating multifocal ischemia in animals leading to left ventricular (LV) functional impairment is described. In a series of 10 mongrel dogs, electrodes were implanted in multiple branches of the coronary arteries. Subsequently, in seven animals, an 800-microA anodal current was applied for 3 h repeatedly o...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1984.tb04321.x

    authors: Polanski J,Mandell G,Wasfie T,Freed PS,Yoshizu H,Stein PD,Sabbah HN,Kantrowitz A

    更新日期:1984-11-01 00:00:00

  • Intermittent stops of shear reduce the mechanical damage of red blood cells.

    abstract::Continuous and intermittent high shear were loaded to red blood cells in a cone and a plate rheoscope. The mechanical damage to red cells was compared for continuous and intermittent shear. The intermittent shear was achieved by alternately starting and stopping shear repeatedly. In the case of intermittent shear load...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2007.00408.x

    authors: Mizunuma H,Sakai S

    更新日期:2007-06-01 00:00:00

  • Use of an integrated sideport for diagnosis and management of decreased flow rates in a programmable implanted insulin delivery system. Implantable Insulin Pump Trial Study Group.

    abstract::The aim of this study was to develop procedures for the diagnosis and nonsurgical management of decreased insulin flow in an implantable programmable pump for long-term intraperitoneal or intravenous insulin delivery featuring a sideport. Patency of the catheter lumen was tested by measuring the time needed for sidepo...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1525-1594.1996.tb04586.x

    authors: Scavini M,Reich S,Eaton RP,Charles MA,Dunn FL

    更新日期:1996-09-01 00:00:00

  • Pulse push/pull hemodialysis: in vitro study on new dialysis modality with higher convective efficiency.

    abstract::Midsize molecule retention is related with renal-failure-associated mortality. Here, the authors describe a new dialysis modality, pulse push/pull hemodialysis (PPPHD), which increases convective clearance. Blood and dialysate are circulated by a pulsatile pump, but with pulsatile flow patterns that are 180 degrees ou...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00561.x

    authors: Lee K,Lee SR,Mun CH,Min BG

    更新日期:2008-05-01 00:00:00

  • Zero-balance ultrafiltration of the priming blood modifies the priming components and improves the clinical outcome in infants undergoing cardiopulmonary bypass: A randomized controlled trial.

    abstract::Cardiopulmonary bypass (CPB) requirement in infants presents a unique challenge because of the large prime volume-to-blood volume ratio. Packed red blood cells (PRBCs) tend to deteriorate with long-term storage owing to their unphysiological composition and osmolality. Given that blood priming is inevitable in neonate...

    journal_title:Artificial organs

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/aor.13559

    authors: Gholampour Dehaki M,Niknam S,Bakhshandeh H,Azarfarin R

    更新日期:2020-03-01 00:00:00

  • Paper is a compatible bed for rat hepatocytes.

    abstract::To develop an effective hybrid bioartificial liver (BAL) device, the material of the scaffold is very important to support hepatocytes that have both growth ability and hepatic differentiated functions. In this study we used paper (Kimwipe, Kimberly-Clark Corp., Roswell, GA, U.S.A.) as a scaffold. Primary hepatocytes ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06506.x

    authors: Mizuguchi T,Mitaka T,Sato F,Mochizuki Y,Hirata K

    更新日期:2000-04-01 00:00:00

  • Forward osmosis process for dialysis fluid regeneration.

    abstract::In a preliminary experiment, 38% of the spent dialysis fluid water was reclaimed by a forward osmosis process through a cellulose triacetate membrane. The simplicity of forward osmosis and its minimal external energy requirements may allow the construction of a small bulk device that can reclaim a considerable portion...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00816.x

    authors: Talaat KM

    更新日期:2009-12-01 00:00:00

  • The PediPump: a new ventricular assist device for children.

    abstract::Options for mechanical circulatory support for the treatment of end-stage heart failure in children are limited. Ventricular assist devices (VADs), which have revolutionized cardiac care in adults, remain largely unavailable for pediatric applications. The PediPump is a new rotary dynamic VAD designed to provide suppo...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2005.29088.x

    authors: Duncan BW,Lorenz M,Kopcak MW,Fukamachi K,Ootaki Y,Chen HM,Chapman PA,Davis SJ,Smith WA

    更新日期:2005-07-01 00:00:00

  • The design modification of advanced ventricular assist device to enhance pulse augmentation and regurgitant flow shut-off.

    abstract::The new Advanced ventricular assist device (Advanced VAD) has many features such as improving pulsatility and preventing regurgitant flow during pump stoppage. The purpose of this study was to evaluate the effects of design modifications of the Advanced VAD on these features in vitro. Bench testing of four versions of...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13484

    authors: Miyamoto T,Byram N,Karimov JH,Adams J,Dessoffy R,Kuban BD,Gao S,Horvath DJ,Fukamachi K

    更新日期:2019-10-01 00:00:00

  • Numerical Simulation of Nonpulsatile Left Ventricular Bypass.

    abstract::A computer simulation was carried out to investigate the influence of nonpulsatile left ventricular assistance on hemodynamics. A simulation circuit was constructed to represent the circulatory system. A source of current was added to denote the nonpulsatile blood pump. The left and right ventricles were replaced by v...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1996.tb04494.x

    authors: Mitsui N,Fukunaga S,Koura Y,Morita S,Hotei H,Sueshiro M,Sueda T,Matsuura Y

    更新日期:1996-05-01 00:00:00

  • Application of a pressure-relieving air compliance chamber in a single-pulsatile extracorporeal life support system: an experimental study.

    abstract::Nonpulsatile blood pumps are mainly used in extracorporeal life support systems. Although pulsating blood flow is known to be physiological, a pulsatile pump is not commonly applied in a circuit with a membrane oxygenator because of damage to the blood cells. The hypothesis that the placement of a pressure-relieving c...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2004.07341.x

    authors: Kim TS,Sun K,Lee KB,Lee HW,Baek KJ,Park SY,Son HS,Kim KT,Kim HM

    更新日期:2004-12-01 00:00:00

  • Re-endothelialization of non-detergent decellularized porcine vessels.

    abstract::Tissue engineering utilizes an interdisciplinary approach to generate constructs for the treatment and repair of diseased organs. Generation of small vessels as vascular grafts or as envisioned central vessel for vascularized constructs is still a challenge. Here, the decellularization of porcine vessels by a non-dete...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13836

    authors: Eyre K,Samper E,Haverich A,Hilfiker A,Andrée B

    更新日期:2020-10-01 00:00:00

  • Surgical use of fluosol-DA in Jehovah's Witness patients.

    abstract::The effects of Fluosol-DA 20% on circulating blood cells, hemodynamic parameters, blood gases, and organs are described and compared with the results of phase I human studies and animal experiments. Bleeding of preoperative anemia and/or surgical bleeding, Fluosol-DA 20% was administered to 7 of 10 Jehovah's Witness p...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1984.tb04238.x

    authors: Ohyanagi H,Nakaya S,Okumura S,Saitoh Y

    更新日期:1984-02-01 00:00:00

  • Lipid apheresis: from a heroic treatment to routine clinical practice.

    abstract::Lipid apheresis has developed from a heroic treatment into a routine clinical therapy and currently is the major indication for performing extracorporeal plasma therapy. Whereas it was once reserved for patients with homozygous familial hypercholesterolemia, today it has a place in the secondary prevention of severe c...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1111/j.1525-1594.1996.tb04525.x

    authors: Bosch T

    更新日期:1996-05-01 00:00:00

  • Bacterial and fungal infection in neonates undergoing venoarterial extracorporeal membrane oxygenation: an analysis of the registry data of the extracorporeal life support organization.

    abstract::A review and analysis of 5,001 neonatal venoarterial (VA) extracorporeal membrane oxygenation (ECMO) cases showed that bacterial and fungal infection occurred in 147 (2.9%) and 26 (0.6%) patients, respectively, with an overall incidence of 3.5%. Bivariate analysis was used to compare infected infants with controls, ba...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1996.tb04428.x

    authors: Douglass BH,Keenan AL,Purohit DM

    更新日期:1996-03-01 00:00:00

  • Partial artificial heart (ALVAD) use with subsequent cardiac and renal allografting in a patient with stone heart syndrome.

    abstract::The abdominal left ventricular assist device (ALVAD) is an order of magnitude more effective than conventional intra-aortic balloon pumping (IABP) in unloading and providing circulatory support to the failing left ventricle. This is a report of a unique case which demonstrates that in the absence of pulmonary vascular...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1978.tb01632.x

    authors: Norman JC,Dacso CC,Reul GJ,Massin EK,Klima T,Kahan BD,Keiser JT,Cooley DA

    更新日期:1978-11-01 00:00:00

  • Improved mechanism for capturing muscle power for circulatory support.

    abstract::Although it is now understood that trained skeletal muscle can generate enough steady-state power to provide significant circulatory support, there are currently no means by which to tap this endogenous energy source to aid the failing heart. To that end, an implantable muscle energy converter (MEC) has been construct...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1111/j.1525-1594.2005.29108.x

    authors: Trumble DR,Melvin DB,Byrne MT,Magovern JA

    更新日期:2005-09-01 00:00:00

  • Selective Cerebro-Myocardial Perfusion in Complex Neonatal Aortic Arch Pathology: Midterm Results.

    abstract::Aortic arch repair in newborns and infants has traditionally been accomplished using a period of deep hypothermic circulatory arrest. To reduce neurologic and cardiac dysfunction related to circulatory arrest and myocardial ischemia during complex aortic arch surgery, an alternative and novel strategy for cerebro-myoc...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13128

    authors: Hoxha S,Abbasciano RG,Sandrini C,Rossetti L,Menon T,Barozzi L,Linardi D,Rungatscher A,Faggian G,Luciani GB

    更新日期:2018-04-01 00:00:00

  • Nonstimulated cardiomyoplasty improves hemodynamics in myocardial-infarcted rats.

    abstract::Cardiomyoplasty has been proposed as an alternative surgical treatment for congestive heart failure. The girdling effect of the muscle wrap is believed to reduce diastolic wall stress. We tested the hypothesis that nonstimulated or passive cardiomyoplasty (CDM) would reduce hemodynamic deficits in rats with experiment...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2001.06907.x

    authors: De Angelis K,Leirner AA,Irigoyen MC,Cestari IA

    更新日期:2001-11-01 00:00:00