In Vitro Evaluation of Inflow Cannula Fixation Techniques in Left Ventricular Assist Device Surgery.

Abstract:

:The therapy of terminal heart failure with left ventricular assist devices has become a standard in cardiac surgery. Yet the surgical implantation technique is not standardized and differs from center to center. Complications associated with left ventricular assist device (LVAD) inflow cannula placement are thrombosis, suction events, and flow disturbances. Within this in vitro study we aimed to investigate if the fixation technique of the sewing ring has an impact on the position of the inflow cannula. For this in vitro study the HeartMate III LVAD (Thoratec Corporation, Pleasanton, CA, USA) was used. In five sessions, two approaches were considered for coring of the ventricle for LVAD inflow cannula insertion: "sew-then-core" and "core-then-sew." In the "sew-then-core" technique, the sewing cuff is first affixed to the heart, usually with 8-16 interrupted pledgeted mattress sutures. Subsequently, a cylindrical knife is used to resect a cylindrical core of myocardium to permit cannula insertion. In the "core-then-sew" technique, the sequence is reversed such that the knife is used before the suture ring is affixed. When the "sew-then-core" technique is used, the mattress sutures may be placed with full-thickness bites that penetrate the endocardium (i.e., transmural stitching) or partial-thickness bites that do not penetrate the endocardium (i.e., epicardial stitching). When the "core-then-sew" technique is used, the suture is passed fully into the ventricular lumen and fed back through the cored hole, at which point the needle may be reinserted into the freshly cored myocardium such that it exits the epicardium (i.e., transmural stitching with back stitch) or not (i.e., transmural stitching without back stitch). These four different sewing ring fixation suturing techniques were tested by experienced surgeons to affix the sewing ring: transmural stitching, epicardial stitching, transmural stitching with back stitch, and transmural stitching without back stitch. The sewing ring was sewed onto a silicone dummy designed to simulate the left ventricle with standard 2-0 Ethibond sutures (Ethicon, Somerville, NY, USA). Afterward, the dummies were measured and documented via photography. In addition, porcine hearts were used to simulate the suturing techniques in a physiological setting. The setting of the inflow cannula is substantially influenced by the fixation method of the sewing ring. Epicardial stitching showed the best results with stable cannula fixation, minimal gap around the cannula and no contact between the sutures and sewing ring with blood. The method of transmural stitching without back stitch showed the worst results by creating the biggest epithelial gap between inflow cannula and tissue as well as proving the biggest surface for blood contact between sewing ring and sutures. In general, both "sew-then-core" techniques resulted in a greater degree of apposition between the cuff and epicardial tissue. Within the study we revealed that the surgical fixation of the sewing ring has a significant impact on the inflow cannula stability, position, and tissue apposition in LVAD implantation surgery. Epicardial stitching of the sewing ring provides the best results in order to prevent suction events as well as thrombosis formation.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Hanke JS,Krabatsch T,Rojas SV,Deniz E,Ismail I,Martens A,Shrestha M,Haverich A,Netuka I,Schmitto JD

doi

10.1111/aor.12735

subject

Has Abstract

pub_date

2017-03-01 00:00:00

pages

272-275

issue

3

eissn

0160-564X

issn

1525-1594

journal_volume

41

pub_type

杂志文章
  • Demand for and use of functional electrical stimulation systems and conventional orthoses in the spinal lesioned community of the UK.

    abstract::The use of and demand for functional electrical stimulation (FES) systems and conventional orthoses in the spinal cord lesioned population was assessed. The assessment was conducted by a postal survey of the members of the spinal injury associations in the U.K. Out of all the respondents, only 2% had used an FES syste...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06361.x

    authors: Maxwell DJ,Granat MH,Baardman G,Hermens HJ

    更新日期:1999-05-01 00:00:00

  • Paper is a compatible bed for rat hepatocytes.

    abstract::To develop an effective hybrid bioartificial liver (BAL) device, the material of the scaffold is very important to support hepatocytes that have both growth ability and hepatic differentiated functions. In this study we used paper (Kimwipe, Kimberly-Clark Corp., Roswell, GA, U.S.A.) as a scaffold. Primary hepatocytes ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06506.x

    authors: Mizuguchi T,Mitaka T,Sato F,Mochizuki Y,Hirata K

    更新日期:2000-04-01 00:00:00

  • Prolonged left ventricular dysfunction induced by sequential multifocal ischemic infarcts in dogs.

    abstract::A method of creating multifocal ischemia in animals leading to left ventricular (LV) functional impairment is described. In a series of 10 mongrel dogs, electrodes were implanted in multiple branches of the coronary arteries. Subsequently, in seven animals, an 800-microA anodal current was applied for 3 h repeatedly o...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1984.tb04321.x

    authors: Polanski J,Mandell G,Wasfie T,Freed PS,Yoshizu H,Stein PD,Sabbah HN,Kantrowitz A

    更新日期:1984-11-01 00:00:00

  • An advanced mock circulation loop for in vitro cardiovascular device evaluation.

    abstract::Controlled and repeatable in vitro evaluation of cardiovascular devices using a mock circulation loop (MCL) is essential prior to in vivo or clinical trials. MCLs often consist of only a systemic circulation with no autoregulatory responses and limited validation. This study aimed to develop, and validate against huma...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13636

    authors: Gregory SD,Pauls JP,Wu EL,Stephens A,Steinseifer U,Tansley G,Fraser JF

    更新日期:2020-06-01 00:00:00

  • Reduction of driveline infections through doubled driveline tunneling of left ventricular assist devices.

    abstract::The durability of ventricular assist device (VAD) therapy improved steadily over the past years. However, driveline infections remain a challenge. To test whether an improved surgical implantation technique may lower the incidence of infections, we analyzed all patients receiving a VAD implantation in the years 2008 a...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12036

    authors: Fleissner F,Avsar M,Malehsa D,Strueber M,Haverich A,Schmitto JD

    更新日期:2013-01-01 00:00:00

  • The E4T electric powered total artificial heart (TAH).

    abstract::The E4T is a totally implantable total artificial heart (TAH) resulting from many years of research work at the Cleveland Clinic Foundation (CCF) and Nimbus, Inc. It consists of four implanted subsystems: the pumping unit, the variable volume device, the transcutaneous transformer, and the internal battery. The pumpin...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1988.tb02795.x

    authors: Smith WA,Hete BF,Kiraly RJ,Fujimoto LK,Jacobs GB,Ishikawa M,Butler K,Nosé Y

    更新日期:1988-10-01 00:00:00

  • Impact of hemoglobin concentration and affinity for oxygen on tissue oxygenation: the case of hemoglobin-based oxygen carriers.

    abstract::In patients undergoing exchange-transfusion with hemoglobin (Hb)-based oxygen (O₂) carriers (HBOC), native Hb coexists with newly transfused Hb. The two Hb types share the same arterial and venous PO₂, but their affinities for O₂ vary. A simple spreadsheet model is described aiming at evaluating the contribution of ea...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2011.01296.x

    authors: Samaja M,Terraneo L

    更新日期:2012-02-01 00:00:00

  • The effects of homologous cross-circulation and in situ liver perfusion on fulminant hepatic failure rats.

    abstract::A galactosamine-induced fulminant hepatic failure (FHF) rat model was used to study the effects of homologous cross-circulation and in situ liver perfusion. Cross-circulation with homologous donors did not significantly improve the survival time or recovery rate of grade II hepatic coma rats. Homologous in situ liver ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1980.tb03929.x

    authors: Mohsini K,Lister C,Chang TM

    更新日期:1980-08-01 00:00:00

  • Are the Current Doppler Echocardiography Criteria Able to Discriminate Mitral Bileaflet Mechanical Heart Valve Malfunction? An In Vitro Study.

    abstract::Malfunction of bileaflet mechanical heart valves in the mitral position could either be due to patient-prosthesis mismatch (PPM) or leaflet obstruction. The aim of this article is to investigate the validity of current echocardiographic criteria used for diagnosis of mitral prosthesis malfunction, namely maximum veloc...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12653

    authors: Evin M,Guivier-Curien C,Pibarot P,Kadem L,Rieu R

    更新日期:2016-05-01 00:00:00

  • Effect of cyclosporine therapy with low doses of corticosteroids on idiopathic nephrotic syndrome.

    abstract::Cyclosporine (CyA) has an immunosuppressive effect that might suggest a therapeutic role in idiopathic glomerular conditions. We focused on the optimization of CyA treatment control in patients with idiopathic nephrotic syndrome by using trough-level CyA measurements (C0) and the 2-h postdose levels (C2). Twenty-two p...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00838.x

    authors: Griveas I,Visvardis G,Papadopoulou D,Nakopolou L,Karanikas E,Gogos K,Stavianoudakis G

    更新日期:2010-03-01 00:00:00

  • Bioengineered cartilage in a scaffold-free method by human cartilage-derived progenitor cells: a comparison with human adipose-derived mesenchymal stromal cells.

    abstract::The objective of our study was to investigate chondrogenesis potential of human adipose-derived mesenchymal stromal cells (MSCs), using as a positive control a human source of cartilage-derived progenitor cells (PCs). This source of PCs was recently described by our group and dwells on the surface of nasoseptal cartil...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12121

    authors: Baptista LS,Silva KR,Pedrosa CS,Amaral RJ,Belizário JV,Borojevic R,Granjeiro JM

    更新日期:2013-12-01 00:00:00

  • Is Multiple Overlapping Uncovered Stents Technique Suitable for Aortic Aneurysm Repair?

    abstract::A computational fluid dynamic model to assess the impact of flow-diverter device on intra-aneurysmal flow in complex aortic aneurysm from the viewpoint of hemodynamics is presented. The aim of this study is to investigate the hemodynamic effects of an endovascular flow-diverter technique using multiple overlapping unc...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12993

    authors: Yeow SL,Leo HL

    更新日期:2018-02-01 00:00:00

  • Evaluation of perfusion modes on vital organ recovery and thyroid hormone homeostasis in pediatric patients undergoing cardiopulmonary bypass.

    abstract::The objectives of this study were: (i) to evaluate the effects of perfusion modes (pulsatile vs. nonpulsatile) on vital organs recovery and (ii) to investigate the influences of two different perfusion modes on the homeostasis of thyroid hormones in pediatric patients undergoing cardiopulmonary bypass (CPB) procedures...

    journal_title:Artificial organs

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/j.1525-1594.2010.01159.x

    authors: Akçevin A,Alkan-Bozkaya T,Qiu F,Undar A

    更新日期:2010-11-01 00:00:00

  • General planning of an artificial organ center.

    abstract::There is an increasing need for research and development centers to deal with design and evaluation of organ replacement systems, the improvement of older devices, and the study of biocompatibility problems. Special attention, in this article, is focused on the determinant role of the background of the investigators i...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1989.tb01579.x

    authors: Vanholder R,Ringoir S

    更新日期:1989-12-01 00:00:00

  • Implantation of the total artificial heart by lateral thoracotomy.

    abstract::Progress in the techniques for surgical implantation of the artificial heart has progressed in parallel with the technology and design of the prosthesis. In the author's first experience with total artificial heart (TAH) implantation (1968) a trans-sternal split was used opening the sixth intercostal space on the righ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1977.tb00984.x

    authors: Olsen DB,Fukumasu H,Kolff J,Nakagaki M,Finch LR,Kolff WJ

    更新日期:1977-11-01 00:00:00

  • A hybrid mock circulation loop for a total artificial heart.

    abstract::Rotary blood pumps are emerging as a viable technology for total artificial hearts, and the development of physiological control algorithms is accelerated with new evaluation environments. In this article, we present a novel hybrid mock circulation loop (HMCL) designed specifically for evaluation of rotary total artif...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12380

    authors: Nestler F,Bradley AP,Wilson SJ,Timms DL,Frazier OH,Cohn WE

    更新日期:2014-09-01 00:00:00

  • The use of electrolyzed solutions for the cleaning and disinfecting of dialyzers.

    abstract::Recently, the use of electrolyzed solutions has attracted considerable interest in Japan. This study investigates the efficiency of electrolyzed solutions as disinfecting agents (DA) in the reuse of dialyzers and compares their efficiency to that of other disinfectants currently in use. The following 3 methods were em...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06611.x

    authors: Tanaka N,Tanaka N,Fujisawa T,Daimon T,Fujiwara K,Yamamoto M,Abe T

    更新日期:2000-12-01 00:00:00

  • The response of articular chondrocytes to type II collagen-Au nanocomposites.

    abstract::The nanocomposites (denoted "CII-Au") of porcine type II collagen (CII) with 0.05, 0.1, 0.5, 1, or 2.5% (wt/wt) Au nanoparticles ( approximately 5 nm) were fabricated for potential use in cartilage tissue engineering. Au formed clusters on the surface of all nanocomposites and appeared to distribute along the collagen...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2007.00482.x

    authors: Hsu SH,Yen HJ,Tsai CL

    更新日期:2007-12-01 00:00:00

  • Cadaver fitting study of the DexAide right ventricular assist device.

    abstract::The DexAide right ventricular assist device (RVAD) has been developed to provide an implantable RVAD option to surgeons. The aim of this study was to determine the optimal cannula design and optimal implantation location of the DexAide RVAD in preparation for its clinical use. Separately, a HeartMate XVE left ventricu...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2007.00438.x

    authors: Ootaki Y,Ootaki C,Kamohara K,Akiyama M,Cingoz F,Kopcak MW Jr,Dessoffy R,Liu J,Massiello A,Horvath D,Chen JF,Zhou Q,Benefit S,Golding LA,Fukamachi K

    更新日期:2007-08-01 00:00:00

  • Estimation of maximum ventricular elastance under assistance with a rotary blood pump.

    abstract::The maximum ventricular elastance is a reliable index for assessing the cardiac function from changes in its pressure-volume relationship. The advantage of this index is that it can represent the contractility of either unassisted hearts or native hearts assisted with rotary blood pumps. However, there are situations ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00876.x

    authors: Sugai TK,Tanaka A,Yoshizawa M,Shiraishi Y,Yambe T,Nitta S,Baba A

    更新日期:2010-05-01 00:00:00

  • Modeling of a rotary blood pump.

    abstract::The accurate representation of rotary blood pumps in a numerical environment is important for meaningful investigation of pump-cardiovascular system interactions. Although numerous models for ventricular assist devices (VADs) have been developed, modeling methods for rotary total artificial hearts (rTAHs) are still re...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12142

    authors: Nestler F,Bradley AP,Wilson SJ,Timms DL

    更新日期:2014-03-01 00:00:00

  • Tissue reactions to various percutaneous materials with different surface properties and structures.

    abstract::Tissue responses to various percutaneous materials with different surface properties and structures were investigated. Dense hydroxyapatite (HA), tricalcium phosphate (TCP), glassy carbon (GC), and 2 types of porous HA were used. Cutaneous and subcutaneous tissues were tightly attached to the surface of the penetratin...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb00514.x

    authors: Shin Y,Akao M

    更新日期:1997-09-01 00:00:00

  • A new blood pump for cardiopulmonary bypass: the HiFlow centrifugal pump.

    abstract::Centrifugal blood pumps are considered to be generally superior to the traditionally used roller pumps in cardiopulmonary bypass. In our institute a new lightweight centrifugal sealless blood pump with a unique spherical thrust bearing and with a magnetic coupling was developed, the HiFlow. The small design makes the ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb03754.x

    authors: Göbel C,Eilers R,Reul H,Schwindke P,Jörger M,Rau G

    更新日期:1997-07-01 00:00:00

  • In vivo characterization of a decellularized dermis-polymer complex for use in percutaneous devices.

    abstract::To develop a method for making percutaneous devices that have high biocompatibility and do not induce downgrowth of epidermal cells, we prepared a partial decellularized dermis (DD)/poly(methyl methacrylate) (PMMA) complex (PDPC) with a PMMA rod firmly stabilized inside. The porcine decellularized tissue was chosen be...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12330

    authors: Nam K,Matsushima R,Kimura T,Fujisato T,Kishida A

    更新日期:2014-12-01 00:00:00

  • Further development of hybrid functional electrical stimulation orthoses.

    abstract::In this study two aspects of hybrid functional electrical stimulation (FES) orthoses were investigated: joint motion constraints and FES control strategies. First, the effects of joint motion constraints on the gait of normal subjects were investigated using modern motion analysis systems, including electromyogram (EM...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1525-1594.1997.tb04648.x

    authors: Yang L,Granat MH,Paul JP,Condie DN,Rowley DI

    更新日期:1997-03-01 00:00:00

  • Influence of growth hormone on maintenance of capillary-like structures in an in vitro model of stromal vascular tissue--results from morphometric analysis.

    abstract::The in vitro development of a vascular stroma might be a solution for the engineering of vascularized tissues, however, in vitro stability of capillary-like structures is limited. In order to test the influence on maintenance of capillary-like structures, human growth hormone (hGH) was added in concentrations of 0.5, ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2005.29057.x

    authors: Frerich B,Kurtz-Hoffmann J,Lindemann N

    更新日期:2005-04-01 00:00:00

  • Regenerative medicine for cardiovascular disorders-new milestones: adult stem cells.

    abstract::Cardiovascular disorders are the leading causes of mortality and morbidity in the developed world. Cell-based modalities have received considerable scientific attention over the last decade for their potential use in this clinical arena. This review was intended as a brief overview on the subject of therapeutic potent...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1111/j.1525-1594.2006.00209.x

    authors: Akar AR,Durdu S,Corapcioglu T,Ozyurda U

    更新日期:2006-04-01 00:00:00

  • A bedside micromethod for the determination of total carbon dioxide in biological fluids.

    abstract::The quality control of bicarbonate hemodialysis requires the determination of TCO2, either in blood or in dialysate. The use of the M + D TCO2 kit, a bedside micromethod, gave the authors an economical and reliable solution to this problem. ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1985.tb04404.x

    authors: Canaud B,Araujo A,Nguyen QV,Flavier JL,Mion C

    更新日期:1985-11-01 00:00:00

  • Pulse push/pull hemodialysis: in vitro study on new dialysis modality with higher convective efficiency.

    abstract::Midsize molecule retention is related with renal-failure-associated mortality. Here, the authors describe a new dialysis modality, pulse push/pull hemodialysis (PPPHD), which increases convective clearance. Blood and dialysate are circulated by a pulsatile pump, but with pulsatile flow patterns that are 180 degrees ou...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00561.x

    authors: Lee K,Lee SR,Mun CH,Min BG

    更新日期:2008-05-01 00:00:00

  • Central Extracorporeal Life Support With Left Ventricular Decompression to Berlin Heart Excor: A Reliable "Bridge to Bridge" Strategy in Crash and Burn Patients.

    abstract::The aim of this study was to compare patients with severe biventricular heart failure who underwent Berlin Heart Excor implantation with (cardiogenic shock [CS] status) or without the need for preoperative extracorporeal life support (ECLS) as a bridge to long-term device. A total of 40 consecutive patients with sever...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12792

    authors: Weymann A,Farag M,Sabashnikov A,Fatullayev J,Zeriouh M,Schmack B,Arif R,Müller F,Alt C,Raake P,Prakash Patil N,Popov AF,Rüdiger Simon A,Karck M,Ruhparwar A,Heidelberg-Cologne-Harefield Cardiothoracic Transplantation & Mecha

    更新日期:2017-06-01 00:00:00