Tissue reactions to various percutaneous materials with different surface properties and structures.

Abstract:

:Tissue responses to various percutaneous materials with different surface properties and structures were investigated. Dense hydroxyapatite (HA), tricalcium phosphate (TCP), glassy carbon (GC), and 2 types of porous HA were used. Cutaneous and subcutaneous tissues were tightly attached to the surface of the penetrating portion of an HA percutaneous device (PD). Neither bacterial infection nor serious epidermal downgrowth were observed in the area surrounding the shaft of the HA-PD. At the margin of the epidermis, fibroblasts and collagen fibrils of fibrous connective tissue were well oriented and formed perpendicular to the shaft. The tissue response to the TCP was mild and nearly the same as that to the HA. The GC induced serious epidermal downgrowth and inflammatory cell infiltration. In contrast to dense HA-PD, the insertion of both types of porous HA-PDs, 1 with a spongy structure and 1 with close pores was followed by acute infection within 1 month. Based upon these results, it was concluded that the dense HA was the best percutaneous material of those tested.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Shin Y,Akao M

doi

10.1111/j.1525-1594.1997.tb00514.x

subject

Has Abstract

pub_date

1997-09-01 00:00:00

pages

995-1001

issue

9

eissn

0160-564X

issn

1525-1594

journal_volume

21

pub_type

杂志文章
  • Coronary artery anatomy of the goat.

    abstract::The coronary arteries of the goat heart were studied using angiographic techniques and molds of the coronary vessel trees. Blood supplies to the left and right ventricles, interventricular septum, atrioventricular node, and apex of the caprine heart were studied. The goat possesses a left dominant pattern of coronary ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1983.tb04192.x

    authors: Lipovetsky G,Fenoglio JJ,Gieger M,Srinivasan MR,Dobelle WH

    更新日期:1983-05-01 00:00:00

  • Permanent cardiac pacing after cardiac operations.

    abstract::From January 1980 through December 1990, implantation of a permanent pacemaker was performed in 34 patients following open heart surgery. The patients were divided into two groups according to the clinical indications for implantation of permanent pacemakers. Group 1 (9 patients) had surgical atrioventricular block, a...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1993.tb00591.x

    authors: Otaki M

    更新日期:1993-05-01 00:00:00

  • Multifunctional implantable nerve stimulator for cardiac assistance by skeletal muscle.

    abstract::Different methods are used, clinically and experimentally, to assist severely impaired heart function by means of skeletal muscle. The efficiency of these methods is restricted by skeletal muscle losing strength after transpositioning and during conditioning and not being sufficiently resistant to fatigue. This is mai...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06258.x

    authors: Lanmüller H,Sauermann S,Unger E,Schnetz G,Mayr W,Bijak M,Girsch W

    更新日期:1999-04-01 00:00:00

  • Artificial cells with emphasis on cell encapsulation of genetically engineered cells.

    abstract::Artificial cells are prepared in the laboratory for medical and biotechnological applications. Encapsulated cells are being studied for the treatment of diabetes, liver failure, and other conditions. More recently, there have been extensive studies into the use of encapsulated genetically engineered cells for gene the...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.06243.x

    authors: Chang TM

    更新日期:1998-11-01 00:00:00

  • The use of an approved biodegradable polymer scaffold as a solid support system for improvement of islet engraftment.

    abstract::The aim of this study was to investigate whether the use of a medically approved biodegradable scaffold as a solid support system would enhance graft survival following transplantation into the omental pouch in a preclinical large animal model. Six beagle dogs underwent total pancreatectomy followed by islet autotrans...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00688.x

    authors: Kin T,O'Neil JJ,Pawlick R,Korbutt GS,Shapiro AM,Lakey JR

    更新日期:2008-12-01 00:00:00

  • Detection of suction and regurgitation of the implantable centrifugal pump based on the motor current waveform analysis and its application to optimization of pump flow.

    abstract::In this study, a detection algorithm for suction and regurgitation of the centrifugal pump during left heart bypass without relying on external flow or pressure sensors was developed and evaluated in acute studies using adult goats. The detection scheme relies on power spectral density (PSD) analysis of the motor curr...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06397.x

    authors: Yuhki A,Hatoh E,Nogawa M,Miura M,Shimazaki Y,Takatani S

    更新日期:1999-06-01 00:00:00

  • Albumin-coated Amberlite XAD-7 resin for hemoperfusion in acute liver failure. Part II: in vivo evaluation.

    abstract::Albumin-coated Amberlite XAD-7 has been previously shown to be blood compatible in in vitro hemoperfusion experiments whith human blood. In this study, the preliminary results are reported on single hemoperfusions with albumin-coated XAD-7 resin in four patients with acute liver failure. The mean platelet count was 11...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1979.tb03800.x

    authors: Hughes R,Ton HY,Langley P,Davies M,Hanid MA,Mellon P,Silk DB,Williams R

    更新日期:1979-02-01 00:00:00

  • A computerized model to analyze transcellular fluid shift during hemofiltration.

    abstract::Using urea and inulin as markers, we have developed a simple method to calculate intracellular and extracellular fluid volume in patients before and after hemofiltration therapy. During conventional hemofiltration using substitution fluid with a Na+ concentration of 140 mEq/L, a decrease in extracellular fluid volume ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1982.tb04054.x

    authors: Kimura G,Satani M,Kojima S,Kuroda K,Itoh K,Ikeda M

    更新日期:1982-02-01 00:00:00

  • Selective Cerebro-Myocardial Perfusion in Complex Neonatal Aortic Arch Pathology: Midterm Results.

    abstract::Aortic arch repair in newborns and infants has traditionally been accomplished using a period of deep hypothermic circulatory arrest. To reduce neurologic and cardiac dysfunction related to circulatory arrest and myocardial ischemia during complex aortic arch surgery, an alternative and novel strategy for cerebro-myoc...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13128

    authors: Hoxha S,Abbasciano RG,Sandrini C,Rossetti L,Menon T,Barozzi L,Linardi D,Rungatscher A,Faggian G,Luciani GB

    更新日期:2018-04-01 00:00:00

  • Initial experience with Impella RP in a quaternary transplant center.

    abstract::Right ventricular failure is one of the most common complications encountered after left ventricular assist device implantation and heart transplantation. It has been reported to have an incidence up to 30%. It increases morbidity and short-term mortality. Impella RP is a small pump that can provide up to 4L/min of fl...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13610

    authors: Monteagudo-Vela M,Simon A,Panoulas V

    更新日期:2020-05-01 00:00:00

  • A novel technique to produce tubular scaffolds based on collagen and elastin.

    abstract::Tubular polymer scaffolds based on tissue engineering techniques have been studied as potential alternatives for vascular regeneration implants. The blood vessels of the cardiovascular system are mainly fibrous, composed of collagen (Col) and elastin (El), and its inner layer consists of endothelial cells. In this wor...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13857

    authors: Rodrigues ICP,Pereira KD,Woigt LF,Jardini AL,Luchessi AD,Lopes ÉSN,Webster TJ,Gabriel LP

    更新日期:2020-11-10 00:00:00

  • An advanced mock circulation loop for in vitro cardiovascular device evaluation.

    abstract::Controlled and repeatable in vitro evaluation of cardiovascular devices using a mock circulation loop (MCL) is essential prior to in vivo or clinical trials. MCLs often consist of only a systemic circulation with no autoregulatory responses and limited validation. This study aimed to develop, and validate against huma...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13636

    authors: Gregory SD,Pauls JP,Wu EL,Stephens A,Steinseifer U,Tansley G,Fraser JF

    更新日期:2020-06-01 00:00:00

  • Cytotoxicity of bile in human Hep G2 cells and in primary cultures of rat hepatocytes.

    abstract::There has been increasing interest in the development of a hepatocyte bioreactor for the treatment of acute hepatic failure; however, little is known about the effect of hepatocyte byproducts on the viability of the cells in the bioreactor environment. We investigated the effects of increasing concentrations of bile o...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.06088.x

    authors: Smirthwaite AD,Gaylor JD,Cousins RB,Grant MH

    更新日期:1998-10-01 00:00:00

  • Risk factor forlung infection in recipients after liver transplantation:a meta-analysis.

    abstract:OBJECTIVE:Lung infection (LI) often occurs in patients with liver transplantation (LT). This meta-analysis was conducted to determine the risk factors associated with LI after LT. METHODS:We retrieved relevant research published as of February 2020 from 8 electronic databases. The studieswere reviewed against the incl...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13826

    authors: Zhang J,He Q,Du L,Ji R,Yuan L,Zhang H,Yuan X,Shen L,Li Y

    更新日期:2020-09-26 00:00:00

  • Evidence of absence of porcine endogenous retrovirus (PERV) infection in patients treated with a bioartificial liver support system.

    abstract::Porcine endogenous retrovirus (PERV) genomes are present in all pig cells. In this retrospective study, we assessed PERV infectivity in 28 patients treated with an extracorporeal bioartificial liver (HepatAssist system) that includes a membrane device containing porcine hepatocytes. All patients tested negative for PE...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06444.x

    authors: Pitkin Z,Mullon C

    更新日期:1999-09-01 00:00:00

  • Impact of hemoglobin concentration and affinity for oxygen on tissue oxygenation: the case of hemoglobin-based oxygen carriers.

    abstract::In patients undergoing exchange-transfusion with hemoglobin (Hb)-based oxygen (O₂) carriers (HBOC), native Hb coexists with newly transfused Hb. The two Hb types share the same arterial and venous PO₂, but their affinities for O₂ vary. A simple spreadsheet model is described aiming at evaluating the contribution of ea...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2011.01296.x

    authors: Samaja M,Terraneo L

    更新日期:2012-02-01 00:00:00

  • Arterial pressure: its role in perfusion and as a criterion of extracorporeal circulation adequacy.

    abstract::Thirty-five patients undergoing open-heart surgery are reported. Cardiac index, mean arterial pressure, oxygen consumption, lactate, pyruvate, and lactate excess in the blood were measured. An inverse correlation of arterial pressure with oxygen consumption and lactate excess was found during perfusion. Comparison of ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1982.tb01675.x

    authors: Osipov VP,Khodas MJ,Dementjeva II,Pjatnitskaja GKh

    更新日期:1982-08-01 00:00:00

  • Role of the BioMedicus pump and distal aortic perfusion in thoracoabdominal aortic aneurysm repair.

    abstract::We reviewed the role of the BioMedicus pump in the reduction of neurologic complications following the repair of Type 1 and Type 2 thoracoabdominal aortic aneurysms. Since 1991, we have used several different methods for the repair of thoracoabdominal aortic aneurysms including simple cross-clamping, selective use of ...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:

    authors: Safi HJ

    更新日期:1996-06-01 00:00:00

  • Ferritin: a reliable indicator of iron supplementation in patients on chronic hemodialysis/hemofiltration treatment?

    abstract::Four hundred and forty-two serum ferritin determinations were performed in 144 patients on chronic intermittent hemodialysis treatment with intravenous iron substitution and/or oral iron substitution. Iron substitution should be done individually according to regular serum ferritin determinations. Intravenous iron sub...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1981.tb03980.x

    authors: Müller HA,Schneider H,Hövelborn U,Streicher E

    更新日期:1981-05-01 00:00:00

  • Prevention of right heart failure after left ventricular assist device implantation by phosphodiesterase 5 inhibitor.

    abstract::Right ventricular (RV) function immediately after left ventricular assist device (LVAD) implantation is a crucial prognostic factor. RV failure is linked to increased mortality and worse outcome. A phosphodiesterase 5 inhibitor, sildenafil, was shown to decrease pulmonary vascular resistance and pulmonary artery press...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12277

    authors: Hamdan R,Mansour H,Nassar P,Saab M

    更新日期:2014-11-01 00:00:00

  • Plasma exchange and immunoadsorption for removal of antibodies prior to ABO incompatible bone marrow transplant.

    abstract::ABO incompatible allogeneic bone marrow transplants can be performed successfully to treat patients with leukemia or aplastic anemia. These transplants carry no great risk of rejection or graft-versus-host disease, however, some method must be used to avoid acute hemolysis at the time of infusion of ABO incompatible m...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1981.tb03998.x

    authors: Bensinger WI

    更新日期:1981-08-01 00:00:00

  • Improved mechanism for capturing muscle power for circulatory support.

    abstract::Although it is now understood that trained skeletal muscle can generate enough steady-state power to provide significant circulatory support, there are currently no means by which to tap this endogenous energy source to aid the failing heart. To that end, an implantable muscle energy converter (MEC) has been construct...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1111/j.1525-1594.2005.29108.x

    authors: Trumble DR,Melvin DB,Byrne MT,Magovern JA

    更新日期:2005-09-01 00:00:00

  • An in vitro investigation into the hemodynamic effects of orifice geometry and position on left ventricular vortex formation and turbulence intensity.

    abstract::In a healthy human cardiac system, a large asymmetric clockwise vortex present in the left ventricle (LV) efficiently diverts the filling jet from the mitral annulus to the left ventricular outflow track. However, prior clinical studies have shown that artificial mitral valve replacement can affect the formation of ph...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13781

    authors: Tan SG,Hon JKF,Nguyen YN,Kim S,Leo HL

    更新日期:2020-12-01 00:00:00

  • Flow balance between the left and right cardiac output of an eccentric roller type total artificial heart.

    abstract::We have made an eccentric roller type total artificial heart (ERTAH). The ERTAH is a positive-displacement device comparable to a DeBakey roller pump. Its left and right outputs are determined by the size of its blood chambers, and the ratio of its left and right output is almost constant. We focused on an interatrial...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06414.x

    authors: Wada H,Fukunaga S,Watari M,Sakai H,Sugawara Y,Ochikubo H,Imai K,Shibamura H,Orihashi K,Sueda T,Matsuura Y

    更新日期:1999-08-01 00:00:00

  • A compact highly efficient and low hemolytic centrifugal blood pump with a magnetically levitated impeller.

    abstract::A magnetically levitated (maglev) centrifugal blood pump (CBP), intended for use as a ventricular assist device, needs to be highly durable and reliable for long-term use without any mechanical failure. Furthermore, maglev CBPs should be small enough to be implanted into patients of various size and weight. We have de...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2006.00202.x

    authors: Asama J,Shinshi T,Hoshi H,Takatani S,Shimokohbe A

    更新日期:2006-03-01 00:00:00

  • Hemodynamic Evaluation of a Biological and Mechanical Aortic Valve Prosthesis Using Patient-Specific MRI-Based CFD.

    abstract::Modeling different treatment options before a procedure is performed is a promising approach for surgical decision making and patient care in heart valve disease. This study investigated the hemodynamic impact of different prostheses through patient-specific MRI-based CFD simulations. Ten time-resolved MRI data sets w...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12955

    authors: Hellmeier F,Nordmeyer S,Yevtushenko P,Bruening J,Berger F,Kuehne T,Goubergrits L,Kelm M

    更新日期:2018-01-01 00:00:00

  • End-point temperature of rewarming after hypothermic cardiopulmonary bypass in pediatric patients.

    abstract::In an attempt to find an adequate end-point rewarming temperature after hypothermic cardiopulmonary bypass (CPB), 50 pediatric patients who underwent cardiac surgery were randomly assigned for the end-point rectal rewarming temperature at either 35.5 (Group 1) or 37.0 degrees C (Group 2). The patients' rectal temperat...

    journal_title:Artificial organs

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/j.1525-1594.2005.00149.x

    authors: Kim WG,Yang JH

    更新日期:2005-11-01 00:00:00

  • Clinical use of low porosity woven ultrafine polyester fiber grafts.

    abstract::A woven fabric graft made of ultrafine polyester fibers (UFPF) (Toray Graft, water porosity: 100 ml/min/cm2:120 mm Hg H2O) was clinically applied in 81 cases (28 thoracic aortic aneurysms, 6 thoracoabdominal aortic aneurysms, 42 abdominal aortic aneurysms, and 5 atherosclerotic obstructions of the peripheral arteries)...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1995.tb02245.x

    authors: Satoh S,Niu S,Kanda K,Hirai J,Nakazima S,Wada Y,Oka T,Noishiki Y

    更新日期:1995-01-01 00:00:00

  • Circulatory loop design and components introduce artifacts impacting in vitro evaluation of ventricular assist device thrombogenicity: A call for caution.

    abstract::Mechanical circulatory support (MCS) devices continue to be hampered by thrombotic adverse events (AEs), a consequence of device-imparted supraphysiologic shear stresses, leading to shear-mediated platelet activation (SMPA). In advancing MCS devices from design to clinical use, in vitro circulatory loops containing th...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13626

    authors: Li M,Walk R,Roka-Moiia Y,Sheriff J,Bluestein D,Barth EJ,Slepian MJ

    更新日期:2020-06-01 00:00:00

  • Surgical use of fluosol-DA in Jehovah's Witness patients.

    abstract::The effects of Fluosol-DA 20% on circulating blood cells, hemodynamic parameters, blood gases, and organs are described and compared with the results of phase I human studies and animal experiments. Bleeding of preoperative anemia and/or surgical bleeding, Fluosol-DA 20% was administered to 7 of 10 Jehovah's Witness p...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1984.tb04238.x

    authors: Ohyanagi H,Nakaya S,Okumura S,Saitoh Y

    更新日期:1984-02-01 00:00:00