Hemodynamic Evaluation of a Biological and Mechanical Aortic Valve Prosthesis Using Patient-Specific MRI-Based CFD.

Abstract:

:Modeling different treatment options before a procedure is performed is a promising approach for surgical decision making and patient care in heart valve disease. This study investigated the hemodynamic impact of different prostheses through patient-specific MRI-based CFD simulations. Ten time-resolved MRI data sets with and without velocity encoding were obtained to reconstruct the aorta and set hemodynamic boundary conditions for simulations. Aortic hemodynamics after virtual valve replacement with a biological and mechanical valve prosthesis were investigated. Wall shear stress (WSS), secondary flow degree (SFD), transvalvular pressure drop (TPD), turbulent kinetic energy (TKE), and normalized flow displacement (NFD) were evaluated to characterize valve-induced hemodynamics. The biological prostheses induced significantly higher WSS (medians: 9.3 vs. 8.6 Pa, P = 0.027) and SFD (means: 0.78 vs. 0.49, P = 0.002) in the ascending aorta, TPD (medians: 11.4 vs. 2.7 mm Hg, P = 0.002), TKE (means: 400 vs. 283 cm2 /s2 , P = 0.037), and NFD (means: 0.0994 vs. 0.0607, P = 0.020) than the mechanical prostheses. The differences between the prosthesis types showed great inter-patient variability, however. Given this variability, a patient-specific evaluation is warranted. In conclusion, MRI-based CFD offers an opportunity to assess the interactions between prosthesis and patient-specific boundary conditions, which may help in optimizing surgical decision making and providing additional guidance to clinicians.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Hellmeier F,Nordmeyer S,Yevtushenko P,Bruening J,Berger F,Kuehne T,Goubergrits L,Kelm M

doi

10.1111/aor.12955

subject

Has Abstract

pub_date

2018-01-01 00:00:00

pages

49-57

issue

1

eissn

0160-564X

issn

1525-1594

journal_volume

42

pub_type

杂志文章
  • Renal osteodystrophy in dialysis patients: diagnosis and treatment.

    abstract::This article reviews the clinical, biological, radiological, and pathological procedures and their respective indications for the practical diagnosis of the following various histological patterns of renal osteodystrophy: osteitis fibrosa due to parathyroid hormone (PTH) hypersecretion: osteomalacia or rickets due to ...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1046/j.1525-1594.1998.06198.x

    authors: Fournier A,Oprisiu R,Hottelart C,Yverneau PH,Ghazali A,Atik A,Hedri H,Said S,Sechet A,Rasolombololona M,Abighanem O,Sarraj A,El Esper N,Moriniere P,Boudailliez B,Westeel PF,Achard JM,Pruna A

    更新日期:1998-07-01 00:00:00

  • Cooling device for bradycardia based on Peltier element for accurate anastomosis of off-pump coronary artery bypass grafting.

    abstract::Upon introducing off-pump coronary artery bypass grafting (CABG), the indications for CABG were expanded to include patients who previously had no operative indications. For accurate anastomosis, various devices and methods have been developed. Bradycardia is easily induced by drug administration. However, this method...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2002.07087.x

    authors: Kuniyoshi Y,Koja K,Miyagi K,Shimoji M,Uezu T,Arakaki K,Yamashiro S,Mabuni K,Senaha S

    更新日期:2002-10-01 00:00:00

  • Chaotic dynamics in circulation with Tohoku University vibrating flow pump.

    abstract::For the development of a totally implantable ventricular assist system (VAS), we have been developing the vibrating flow pump (VFP), which can generate oscillated blood flow with a relative high frequency (10-50 Hz) for a totally implantable system. In this study, the effects of left ventricular assistance with this u...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06288.x

    authors: Nitta S,Yambe T,Kobayashi S,Hashimoto H,Yoshizawa M,Mastuki H,Tabayashi K,Takeda H

    更新日期:1999-01-01 00:00:00

  • Uremic neuropathy: evidence of middle molecule toxicity.

    abstract::Ten dialysis patients were followed in a prospective study to determine the neurotoxicity of metabolites in the middle molecule (MM) molecular weight (mol wt) range of 500-200 daltons/molecule. In the absence of readily available direct serum measurements of MM concentrations, a theoretically calculated dialysis index...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1978.tb01002.x

    authors: Milutinovic J,Babb AL,Eschbach JW,Follette WC,Graefe U,Strand MJ,Scribner BH

    更新日期:1978-02-01 00:00:00

  • Substantial early loss of induced pluripotent stem cells following transplantation in myocardial infarction.

    abstract::The limited success of cardiac stem cell therapy has lately generated discussion regarding its effectiveness. We hypothesized that immediate cell loss after intramyocardial injection significantly obscures the regenerative potential of stem cell therapy. Therefore, our aim was to assess the distribution and quantity o...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12268

    authors: Martens A,Rojas SV,Baraki H,Rathert C,Schecker N,Zweigerdt R,Schwanke K,Rojas-Hernandez S,Martin U,Saito S,Schmitto JD,Haverich A,Kutschka I

    更新日期:2014-11-01 00:00:00

  • The pivot wash in two impeller modes for the Baylor/Miwatec centrifugal blood pump.

    abstract::A centrifugal blood pump with a double pivot impeller and an eccentric inlet port is being developed as an implantable artificial heart by the Baylor College of Medicine and Miwatec Co. Ltd. Flow visualization measurements were conducted to compare the flow around the pivot for two impeller operational modes: the top ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2006.00155.x

    authors: Yamane T,Kodama T,Nishida M,Maruyama O,Yamamoto Y,Shinohara T,Motomura T,Nosé Y

    更新日期:2006-01-01 00:00:00

  • Can the human lumbar posterior columns be stimulated by transcutaneous spinal cord stimulation? A modeling study.

    abstract::Stimulation of different spinal cord segments in humans is a widely developed clinical practice for modification of pain, altered sensation, and movement. The human lumbar cord has become a target for modification of motor control by epidural and, more recently, by transcutaneous spinal cord stimulation. Posterior col...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2011.01213.x

    authors: Danner SM,Hofstoetter US,Ladenbauer J,Rattay F,Minassian K

    更新日期:2011-03-01 00:00:00

  • Proof of principle of a novel co-pulsating intra-ventricular membrane pump.

    abstract::In this proof of principle study, we investigated the effectiveness and safety of hemodynamic support with the Intra-Ventricular Membrane Pump (IVMP). The IVMP was implanted into the apex of the left ventricle. Hemodynamic assessment was performed in six ex vivo beating porcine hearts (PhysioHeart platform). The cardi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13757

    authors: van Dort DIM,Thannhauser J,Gommans FDH,Ten Cate TJ,Duncker DJ,Suryapranata H,Morshuis WJ,Geuzebroek GSC

    更新日期:2020-12-01 00:00:00

  • Detection of suction and regurgitation of the implantable centrifugal pump based on the motor current waveform analysis and its application to optimization of pump flow.

    abstract::In this study, a detection algorithm for suction and regurgitation of the centrifugal pump during left heart bypass without relying on external flow or pressure sensors was developed and evaluated in acute studies using adult goats. The detection scheme relies on power spectral density (PSD) analysis of the motor curr...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06397.x

    authors: Yuhki A,Hatoh E,Nogawa M,Miura M,Shimazaki Y,Takatani S

    更新日期:1999-06-01 00:00:00

  • Dialysate and blood temperature during hemodialysis: comparing isothermic dialysis with a single-pass batch system.

    abstract::The Genius is a convenient single-pass batch hemodialysis system. Dialysate is heated during the preparation phase. Once the container is filled at one of the three available starting temperatures, dialysate cools spontaneously. As dialysate temperature plays an important role in hemodynamic stability, knowledge of th...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00981.x

    authors: Dhondt A,Eloot S,Verbeke F,Vanholder R

    更新日期:2010-12-01 00:00:00

  • Plasma middle molecules in asymptomatic and "sick" uremic patients.

    abstract::By using high speed gel filtration combined with ion exchange gradient elution chromatography, the concentrations of plasma (p) middle molecules (MM) were determined in 126 samples from 90 non-dialyzed azotemic patients and in 210 pre-dialysis samples from 53 regular hemodialysis and 24 intermittent peritoneal dialysi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors: Asaba H,Bergström J,Fürst P,Johnson C,Yahiel V

    更新日期:1981-01-01 00:00:00

  • Reduction of early postoperative morbidity in cardiac surgery patients treated with continuous veno-venous hemofiltration during cardiopulmonary bypass.

    abstract::Cardiac surgery with cardiopulmonary bypass is associated with a systemic inflammatory response syndrome. The major clinical features of this include a reduction of pulmonary compliance and increased extracellular fluids, with increased pulmonary shunt fraction similar to acute respiratory distress syndrome, thus resu...

    journal_title:Artificial organs

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/j.1525-1594.2009.00777.x

    authors: Luciani R,Goracci M,Simon C,Principe F,Fazzari L,Punzo G,Menè P

    更新日期:2009-08-01 00:00:00

  • Cadaver fitting study of the DexAide right ventricular assist device.

    abstract::The DexAide right ventricular assist device (RVAD) has been developed to provide an implantable RVAD option to surgeons. The aim of this study was to determine the optimal cannula design and optimal implantation location of the DexAide RVAD in preparation for its clinical use. Separately, a HeartMate XVE left ventricu...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2007.00438.x

    authors: Ootaki Y,Ootaki C,Kamohara K,Akiyama M,Cingoz F,Kopcak MW Jr,Dessoffy R,Liu J,Massiello A,Horvath D,Chen JF,Zhou Q,Benefit S,Golding LA,Fukamachi K

    更新日期:2007-08-01 00:00:00

  • Pretreatment With Inactivated Bacillus Calmette-Guerin Increases CD4+CD25+ Regulatory T Cell Function and Decreases Functional and Structural Effects of Asthma Induction in a Rat Asthma Model.

    abstract::Bacillus Calmette-Guerin (BCG) has been shown to have therapeutic effects on asthma through CD4+CD25+ regulatory T cells (Tregs). We sought to assess pretreatment with inactivated BCG on CD4+CD25+ Tregs and its functional and structural effects in rat asthma model. The rat asthma model was established using ovalbumin ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12566

    authors: Gong P,Li Y,Tan YP,Li H

    更新日期:2016-04-01 00:00:00

  • Hemolysis Related to Turbulent Eddy Size Distributions Using Comparisons of Experiments to Computations.

    abstract::Turbulent blood flow in medical devices contributes to blood trauma, yet the exact mechanism(s) have not been fully elucidated. Local turbulent stresses, viscous stresses, and the rate of dissipation of the turbulent kinetic energy have been proffered as hypotheses to describe and predict blood damage. In this work, s...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12572

    authors: Ozturk M,O'Rear EA,Papavassiliou DV

    更新日期:2015-12-01 00:00:00

  • Characteristics of chronically paced cardiac functions in the congenital complete atrioventricular block.

    abstract::Characteristics of morphology, cardiac function, and cardiac reserve at late state were evaluated at rest, by changing the pacing rates, and after exercise in patients with ventricular pacemakers for isolated congenital complete atrioventricular block. Heart size was reduced statistically after pacemaker implantation,...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1987.tb02667.x

    authors: Nawa S,Kioka Y,Shimizu A,Tsuji H,Miyachi Y,Ebara K,Kino K,Shigenobu M,Murakami T,Senoo Y

    更新日期:1987-06-01 00:00:00

  • Numerical modeling of blood flow in the ventricular cavity of the artificial heart.

    abstract::The flow of blood as a viscous, Newtonian, incompressible liquid in an expanding spherical cavity with a ball-type inlet valve was examined. This type of flow can serve as a model of the phase of ventricular diastole in a sac-type artificial heart. The critical values of Reynolds numbers at which flow interruption beh...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1983.tb04170.x

    authors: Starobin IM,Zaĭko VM

    更新日期:1983-02-01 00:00:00

  • From wooden limbs to biomaterial organs: the ethics of organ replacement and artificial organs.

    abstract::This paper discussed issues of ethical assessment and moral concern associated with organ replacement and physical enhancement: research, allocation, organ donation, artificial organs, xenografts, biomaterials, and neuromaterials. While emphasizing the medical and moral benefits over associated risks, it calls for a b...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1995.tb02362.x

    authors: Kielstein R,Sass HM

    更新日期:1995-05-01 00:00:00

  • The design modification of advanced ventricular assist device to enhance pulse augmentation and regurgitant flow shut-off.

    abstract::The new Advanced ventricular assist device (Advanced VAD) has many features such as improving pulsatility and preventing regurgitant flow during pump stoppage. The purpose of this study was to evaluate the effects of design modifications of the Advanced VAD on these features in vitro. Bench testing of four versions of...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13484

    authors: Miyamoto T,Byram N,Karimov JH,Adams J,Dessoffy R,Kuban BD,Gao S,Horvath DJ,Fukamachi K

    更新日期:2019-10-01 00:00:00

  • Impact of hemoglobin concentration and affinity for oxygen on tissue oxygenation: the case of hemoglobin-based oxygen carriers.

    abstract::In patients undergoing exchange-transfusion with hemoglobin (Hb)-based oxygen (O₂) carriers (HBOC), native Hb coexists with newly transfused Hb. The two Hb types share the same arterial and venous PO₂, but their affinities for O₂ vary. A simple spreadsheet model is described aiming at evaluating the contribution of ea...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2011.01296.x

    authors: Samaja M,Terraneo L

    更新日期:2012-02-01 00:00:00

  • Reduction of driveline infections through doubled driveline tunneling of left ventricular assist devices.

    abstract::The durability of ventricular assist device (VAD) therapy improved steadily over the past years. However, driveline infections remain a challenge. To test whether an improved surgical implantation technique may lower the incidence of infections, we analyzed all patients receiving a VAD implantation in the years 2008 a...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12036

    authors: Fleissner F,Avsar M,Malehsa D,Strueber M,Haverich A,Schmitto JD

    更新日期:2013-01-01 00:00:00

  • Formation of Blood Foam in the Air Trap During Hemodialysis Due to Insufficient Automatic Priming of Dialyzers.

    abstract::We were encouraged to investigate the reasons for large amounts of foam observed in bloodlines during hemodialysis (HD). Foam was visible in the venous air trap within the Artis Gambro dialysis device. Estimates of the extent of foam were graded (0-no foam, 10-extensive foam) by two persons that were blind to the type...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13070

    authors: Jonsson P,Lindmark L,Axelsson J,Karlsson L,Lundberg L,Stegmayr B

    更新日期:2018-05-01 00:00:00

  • Improved mechanism for capturing muscle power for circulatory support.

    abstract::Although it is now understood that trained skeletal muscle can generate enough steady-state power to provide significant circulatory support, there are currently no means by which to tap this endogenous energy source to aid the failing heart. To that end, an implantable muscle energy converter (MEC) has been construct...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1111/j.1525-1594.2005.29108.x

    authors: Trumble DR,Melvin DB,Byrne MT,Magovern JA

    更新日期:2005-09-01 00:00:00

  • The DeBakey ventricular assist device: current status in 1997.

    abstract::In 1993, the development began of a small axial flow blood pump, the DeBakey ventricular assist device (VAD). The material was recently converted to a titanium alloy, and a waterproof pump package was incorporated for long-term intracorporeal circulation. Thirteen intrathoracic implantations in calves were achieved. N...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1046/j.1525-1594.1999.06300.x

    authors: Tayama E,Olsen DB,Ohashi Y,Benkowski R,Morley D,Noon GP,Nosé Y,Debakey ME

    更新日期:1999-12-01 00:00:00

  • Binding of antithrombin to immobilized heparin under varying flow conditions.

    abstract::Rheologic factors are likely to influence the balance between thrombotic and antithrombotic forces at the level of the vascular wall. In this study, the effects of flow-velocity/wall shear stress on the interaction of antithrombin (AT) with surface-immobilized heparin were investigated. The binding of AT to low-affini...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors: Pasche B,Elgue G,Olsson P,Riesenfeld J,Rasmuson A

    更新日期:1991-12-01 00:00:00

  • In vitro generation of atrioventricular heart valve neoscaffolds.

    abstract::Tissue engineering of cardiovascular structures represents a novel approach to improve clinical strategies in heart valve disease treatment. The aim of this study was to engineer decellularized atrioventricular heart valve neoscaffolds with an intact ultrastructure and to reseed them with umbilical cord-derived endoth...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12321

    authors: Weymann A,Radovits T,Schmack B,Li S,Korkmaz S,Soós P,Istók R,Veres G,Chaimow N,Karck M,Szabó G

    更新日期:2014-07-01 00:00:00

  • Measurement of the closing behavior of the björk-shiley monoleaflet mechanical heart valve with an electrohydraulic total artificial heart.

    abstract::When cavitation occurs near a material surface of a mechanical heart valve (MHV), pits on the surface of the MHV and hemolysis are caused. Therefore, it is very important to investigate the possibility of the occurrence of cavitation in an MHV. To study the possibility of cavitation occurrence in a 25 mm Björk-Shiley ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2003.06981.x

    authors: Lee H,Tsukiya T,Homma A,Taenaka Y,Tatsumi E,Takano H

    更新日期:2003-08-01 00:00:00

  • Judicious usage of estrogen/progesterone for angiodysplasia.

    abstract::We recently experienced a case of a female hemodialysis patient with multiple intestinal angiodysplasias. In 2001, she complained of melena, and angiographic embolization halted bleeding from ileum angiodysplasia. In 2002, she again complained of black stool. Abdominal angiography found jejunum angiodysplasia, and pha...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2004.29003.x

    authors: Takenaka T,Kanno Y,Suzuki H

    更新日期:2005-01-01 00:00:00

  • A newly designed adapter for testing an ex vivo mitral valve apparatus.

    abstract::Few instruments are currently available to test mitral valve function in an ex vivo state due to the technical difficulties involved. To investigate the native ex vivo mitral valve or prosthetic mitral valve with chordae, we developed a mitral valve adapter with an annulus suturing portion and 2 papillary muscle sutur...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06293.x

    authors: Katoh T,Ikeda N,Nishi K,Gohra H,Hamano K,Noda H,Fujimura Y,Esato K

    更新日期:1999-10-01 00:00:00

  • Quantification of Shear-Induced Platelet Activation: High Shear Stresses for Short Exposure Time.

    abstract::Thrombosis and thromboembolism are the life-threatening clinical complications for patients supported or treated with prosthetic cardiovascular devices. The high mechanical shear stress within these devices is believed to be the major contributing factor to cause platelet activation (PA) and function alteration, leadi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12438

    authors: Ding J,Chen Z,Niu S,Zhang J,Mondal NK,Griffith BP,Wu ZJ

    更新日期:2015-07-01 00:00:00