Abstract:
:Malfunction of bileaflet mechanical heart valves in the mitral position could either be due to patient-prosthesis mismatch (PPM) or leaflet obstruction. The aim of this article is to investigate the validity of current echocardiographic criteria used for diagnosis of mitral prosthesis malfunction, namely maximum velocity, mean transvalvular pressure gradient, effective orifice area, and Doppler velocity index. In vitro testing was performed on a double activation left heart duplicator. Both PPM and leaflet obstruction were investigated on a St. Jude Medical Master. PPM was studied by varying the St. Jude prosthesis size (21, 25, and 29 mm) and stroke volume (70 and 90 mL). Prosthesis leaflet obstruction was studied by partially or totally blocking the movement of one valve leaflet. Mitral flow conditions were altered in terms of E/A ratios (0.5, 1.0, and 1.5) to simulate physiologic panel of diastolic function. Maximum velocity, effective orifice area, and Doppler velocity index are shown to be insufficient to distinguish normal from malfunctioning St. Jude prostheses. Doppler velocity index and effective orifice area were 1.3 ± 0.49 and 1.83 ± 0.43 cm(2) for testing conditions with no malfunction below the 2.2 and 2 cm(2) thresholds (1.19 cm(2) for severe PPM and 1.23 cm(2) for fully blocked leaflet). The mean pressure gradient reached 5 mm Hg thresholds for several conditions of severe PPM only (6.9 mm Hg and mean maximum velocity value: 183.4 cm/s) whereas such value was never attained in the case of leaflet obstruction. In the case of leaflet obstruction, the maximum velocity averaged over the nine pulsed-wave Doppler locations increased by 38% for partial leaflet obstruction and 75% for a fully blocked leaflet when compared with normal conditions. Current echocardiographic criteria might be suboptimal for the detection of bileaflet mechanical heart valve malfunction. Further developments and investigations are required in order to further improve current guidelines.
journal_name
Artif Organsjournal_title
Artificial organsauthors
Evin M,Guivier-Curien C,Pibarot P,Kadem L,Rieu Rdoi
10.1111/aor.12653subject
Has Abstractpub_date
2016-05-01 00:00:00pages
E52-60issue
5eissn
0160-564Xissn
1525-1594journal_volume
40pub_type
杂志文章abstract::The postdialysis levels of serum sodium concentration, urea concentration, and osmolality, as well as the magnitude of both transcellular fluid shifts and sodium removal, were predicted based on computer modeling without measuring body fluid volumes. A 4-h hemodialysis was performed in five patients at a constant ultr...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1983.tb04219.x
更新日期:1983-11-01 00:00:00
abstract::Mechanical circulatory support (MCS) devices for pediatric patients continue to lag in development behind those for adults. There is no heart pump with the design innovation to support dysfunctional states of heart failure and the anatomic heterogeneity of cardiac defects in pediatric patients. To address this unmet n...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.13507
更新日期:2019-11-01 00:00:00
abstract::Giant cerebral aneurysms may be untreatable by conventional neurosurgical techniques. Early attempts to use circulatory assistance and deep hypothermia were abandoned due to hemorrhagic complications. More recently, interest in circulatory support for complex neurosurgical procedures has been renewed. A consecutive se...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.2000.06594.x
更新日期:2000-06-01 00:00:00
abstract::The generation of anaphylatoxins, particularly C5a, is important in extracorporeal circulation therapies such as granulocyte/monocyte apheresis, which activates the complement system and elevates C5a levels. However, no side effects of granulocyte/monocyte apheresis using cellulose acetate beads have been reported. To...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2009.00995.x
更新日期:2010-12-01 00:00:00
abstract::To obtain an optimal design of the left blood chamber of the total artificial heart (TAH), flow visualization studies were performed. Information on velocities in critical areas of the left chamber was gathered using sectional pulsed laser light. The flow patterns on the entire pumping duration were photographed frame...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1994.tb03345.x
更新日期:1994-12-01 00:00:00
abstract::Our aim was to study the feasibility of implanting the Infant Jarvik 2015 in patients weighing less than 8 kg. The Infant Jarvik 2015 left ventricular assist device (LVAD) was tested in a hybrid simulator of the cardiovascular system reproducing specific patients' hemodynamics for different patient weights (2-7 kg). F...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.13302
更新日期:2019-01-01 00:00:00
abstract::The energy dissipated in blood or on a total artificial heart (TAH) chamber's elements directly or indirectly decreases the biological or technical safety of the TAH's work. The energetic analysis of the Polish total artificial heart (POLTAH) external work with the objective of estimating the valve and membrane roles ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.1998.05074.x
更新日期:1998-10-01 00:00:00
abstract::The neutralization of bacterial endotoxins (ET) is still an unsolved problem in therapeutic medicine. The efficacy of anti-endotoxin antibodies or receptor antagonists and other substances interfering with the endotoxin-induced pathomechanisms is dependent on an intact cellular degradation system of the host. However,...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1993.tb00630.x
更新日期:1993-09-01 00:00:00
abstract::The purpose of this study was to characterize changes in hepatic venous pressures in patients with chronic hepatitis C. The histology and laboratory data from patients with chronic hepatitis C who underwent a transjugular liver biopsy (TJLB) and hepatic venous pressure gradient measurement were analyzed. Portal hypert...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2009.00925.x
更新日期:2010-07-01 00:00:00
abstract::Over the past several years, we have developed novel titanium-niobium-zirconium (Ti-Nb-Zr) alloys to address the long-term performance needs of orthopedic implants. The unique properties of these alloys also render them promising candidates for blood pumps. These properties include excellent biocompatibility in combin...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1996.tb04473.x
更新日期:1996-05-01 00:00:00
abstract::We investigated biodegradation and biocompatibility of poly(organophosphazenes). We prepared poly(organophosphazenes) having different side chain groups. The blood compatibility of poly(organophosphazenes) containing fluorinated side groups, poly(bis[trifluoroethoxy]phosphazene) (PbFP) and poly([trifluoroethoxy][ethyl...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.2002.07029.x
更新日期:2002-10-01 00:00:00
abstract::Jaundice is characterized by an excessive accumulation of bilirubin in the blood and tissues. A novel approach to reduce plasma levels of bilirubin by blocking its enterohepatic circulation was investigated. The treatment consisted of oral administration of immobilized bilirubin oxidase, which could oxidize bilirubin ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1992.tb00527.x
更新日期:1992-08-01 00:00:00
abstract::Out-of-Hospital refractory Cardiac Arrest (OHrCA) has a mortality rate between 90 and 95%. Since 2009, French medical academic societies have recommended the use of extracorporeal life support (ECLS) for OHrCA. According to these guidelines, patients were eligible for ECLS support if vital signs were still present dur...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.12655
更新日期:2016-09-01 00:00:00
abstract::Porous polyurethane (nonwoven) was used for the development of tracheal prosthesis, which--in a special testing design--was adapted to shape and biomechanic properties of the natural organ. This prosthesis was implanted into 19 beagle dogs using inverted, everted, and end-to-end anastomosis. Insufficiency of the anast...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1989.tb02866.x
更新日期:1989-06-01 00:00:00
abstract::The aim of this work is the evaluation of four different heat exchangers used for myocardium during cardioplegic system in cardiac surgeries. Four types of shell and tube heat exchangers made of different exchange elements were constructed, as follows: stainless steel tubes, aluminium tubes, polypropylene hollow fiber...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.2003.07240.x
更新日期:2003-05-01 00:00:00
abstract::The limited success of cardiac stem cell therapy has lately generated discussion regarding its effectiveness. We hypothesized that immediate cell loss after intramyocardial injection significantly obscures the regenerative potential of stem cell therapy. Therefore, our aim was to assess the distribution and quantity o...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.12268
更新日期:2014-11-01 00:00:00
abstract::This study aimed to clarify the role of peritoneal T-lymphocytes in peritoneal immune defense mechanisms. This study was designed to examine the changes in T-cell subpopulations during peritonitis in patients treated with continuous ambulatory peritoneal dialysis (CAPD). Our observations were correlated to responses t...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2009.00802.x
更新日期:2009-12-01 00:00:00
abstract::Different from the existing tissue engineering strategies, rapid prototyping (RP) techniques aim to automatically produce complex organs directly from computer-aided design freeform models with high resolution and sophistication. Analogous to building a nuclear power plant, cell biology (especially, renewable stem cel...
journal_title:Artificial organs
pub_type: 杂志文章,评审
doi:10.1111/j.1525-1594.2012.01499.x
更新日期:2012-11-01 00:00:00
abstract::To assess the efficiency of respiratory gas exchange in vitro through a dialysis membrane mounted inside a flat plate Kiil dialyzer, the model reactions of hydrogen peroxide reduction by a metal ion and of the carbon dioxide precipitation in the form of a carbonate in the dialysate were used. A comparison of the rates...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1983.tb04189.x
更新日期:1983-05-01 00:00:00
abstract::Platelet-rich plasma (PRP) contains many growth factors that are involved in tissue regeneration processes. For successful tissue regeneration, protein growth factors require a delivery vehicle for long-term and sustained release to a defect site in order to maintain their bioactivity. Previously, we showed that hepar...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.12389
更新日期:2015-04-01 00:00:00
abstract::In this study two aspects of hybrid functional electrical stimulation (FES) orthoses were investigated: joint motion constraints and FES control strategies. First, the effects of joint motion constraints on the gait of normal subjects were investigated using modern motion analysis systems, including electromyogram (EM...
journal_title:Artificial organs
pub_type: 临床试验,杂志文章
doi:10.1111/j.1525-1594.1997.tb04648.x
更新日期:1997-03-01 00:00:00
abstract::Myristoyl gelatin (MG) retains its gel structure at temperatures above body temperature without any crosslinking. As a coating material, MG adheres well to polyester fibers, and the outermost layers of the sealant that are in contact with blood or surrounding tissue become hydrophilic. We produced MG-impregnated knitt...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1997.tb00363.x
更新日期:1997-04-01 00:00:00
abstract::The aim of the study is to measure the volume of homologous blood needed for one pediatric patient during his hospital stay. Over a 4-month period, all the patients operated upon with a blood prime or requiring blood transfusion during their hospital stay were included in this study.The cardiopulmonary bypass protocol...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2010.01158.x
更新日期:2010-11-01 00:00:00
abstract::Using computed tomography (CT)-based preoperative planning software, we can define with good accuracy the position of a cementless hip stem inside the host bone, but previous studies suggest that the pose the surgeon achieves during freehand surgery may differ from the planned one even by some millimeters. Advances in...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2008.00577.x
更新日期:2008-07-01 00:00:00
abstract::A new intravascular pumping oxygenator (IVPO) was developed for intravascular gas exchange and circulatory assistance in critically ill patients with respiratory and circulatory failure. The IVPO utilizes new silicone hollow fibers (diameter, 1 mm; membrane width, 50 microns) and consists of two driving tubes for the ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1997.tb00703.x
更新日期:1997-01-01 00:00:00
abstract::In a healthy human cardiac system, a large asymmetric clockwise vortex present in the left ventricle (LV) efficiently diverts the filling jet from the mitral annulus to the left ventricular outflow track. However, prior clinical studies have shown that artificial mitral valve replacement can affect the formation of ph...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.13781
更新日期:2020-12-01 00:00:00
abstract::Continuous-flow left ventricular assist devices (LVADs) reduce peak systolic flow, increase diastolic flow, and eliminate pulsatility of circulation. Altered blood flow may lead to a change in end-organ perfusion. Analysis of the flow dynamics of the arteries of end organs, such as the brain, may indicate whether an o...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.13616
更新日期:2020-05-01 00:00:00
abstract::Doppler ultrasound is a noninvasive technique for monitoring moving objects such as flowing blood while ignoring stationary objects such as shunt tubing. A Doppler system was investigated to determine its sensitivity in detecting particulate release in blood during hemodialysis. Seven hemodialysis procedures with dogs...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1984.tb04275.x
更新日期:1984-05-01 00:00:00
abstract::The objective of our study was to investigate chondrogenesis potential of human adipose-derived mesenchymal stromal cells (MSCs), using as a positive control a human source of cartilage-derived progenitor cells (PCs). This source of PCs was recently described by our group and dwells on the surface of nasoseptal cartil...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.12121
更新日期:2013-12-01 00:00:00
abstract::The objective of this study was to evaluate the hemodynamic performance and gaseous microemboli (GME) handling ability of a simulated neonatal extracorporeal life support (ECLS) circuit with an in-line continuous renal replacement therapy (CRRT) device. The circuit consisted of a Maquet RotaFlow centrifugal pump or HL...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.12987
更新日期:2018-04-01 00:00:00