CD4/CD8 T-cell ratio in peritoneal dialysis effluents predicts the outcome of peritonitis in patients undergoing continuous ambulatory peritoneal dialysis.

Abstract:

:This study aimed to clarify the role of peritoneal T-lymphocytes in peritoneal immune defense mechanisms. This study was designed to examine the changes in T-cell subpopulations during peritonitis in patients treated with continuous ambulatory peritoneal dialysis (CAPD). Our observations were correlated to responses to treatment and with outcomes. The present study was carried out in 20 patients (8 males, 12 females) under CAPD. Peritonitis was diagnosed according to the criteria defined by the Ad Hoc Advisory Committee on Peritonitis Management. Peritoneal dialysate effluent (PDE) samples were collected from our patients, and lymphocyte subsets (CD2+, CD3+, CD3+/4+, CD3+/8+, CD3-/16+56+, CD4/CD8 ratio) were quantitated by using monoclonal antibodies. CD4/CD8 ratio was measured every day during peritonitis until the patients had completely recovered. The serial measurements of the CD4/CD8 ratio made in the PDE during peritonitis followed two patterns: the first pattern was characterized by a progressive increase in the CD4/CD8 ratio. The CD4/CD8 ratios on days 5, 6, and 7 were significantly higher than those on day 1 (P < 0.05). Overall, the patients who exhibited pattern 1 had favorable clinical courses. The second pattern was characterized by high initial CD4/CD8 ratios, which progressively decreased significantly (P < 0.05). This second pattern was associated with a delayed clinical response to treatment. Symptoms and signs of peritonitis persisted beyond 72 h. The pattern of the CD4/CD8 ratio in PDE may determine the outcome of peritonitis in CAPD patients.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Griveas I,Fleva A,Karanikas E,Gogos K,Sakellariou G

doi

10.1111/j.1525-1594.2009.00802.x

subject

Has Abstract

pub_date

2009-12-01 00:00:00

pages

1091-5

issue

12

eissn

0160-564X

issn

1525-1594

pii

AOR802

journal_volume

33

pub_type

杂志文章
  • Anticoagulation with fondaparinux for hemodiafiltration in patients with heparin-induced thrombocytopenia: dose-finding study and safety evaluation.

    abstract::The optimal anticoagulation regimen for hemodialysis (HD) in patients with heparin-induced thrombocytopenia (HIT) has not been defined. Hemodiafiltration (HDF) adds a large convective component to HD, thereby changing the pharmacokinetics of most anticoagulants. Data on coagulation regimens for HDF are scant. We there...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12002

    authors: Mahieu E,Claes K,Jacquemin M,Evenepoel P,Op De Beek K,Bogaert AM,Kuypers D,Verhamme P,Meijers B

    更新日期:2013-05-01 00:00:00

  • In Vitro Evaluation of an Alternative Neonatal Extracorporeal Life Support Circuit on Hemodynamic Performance and Bubble Trap.

    abstract::The objective of this study was to evaluate an alternative neonatal extracorporeal life support (ECLS) circuit with a RotaFlow centrifugal pump and Better-Bladder (BB) for hemodynamic performance and gaseous microemboli (GME) capture in a simulated neonatal ECLS system. The circuit consisted of a Maquet RotaFlow centr...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12748

    authors: Spencer SB,Wang S,Woitas K,Glass K,Kunselman AR,Ündar A

    更新日期:2017-01-01 00:00:00

  • Biological evaluation of liposome-encapsulated hemoglobin surface-modified with a novel PEGylated nonphospholipid amphiphile.

    abstract::Traumatic injury is often associated with hemorrhagic shock. Liposome-encapsulated hemoglobin (LEH) is being developed as an artificial oxygen carrier to address post-hemorrhage oxygen and volume deficit. Here, we report a new composition of LEH based on the use of polyethylene glycol (PEG2K ) conjugated with nonphosp...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12304

    authors: Yadav VR,Nag O,Awasthi V

    更新日期:2014-08-01 00:00:00

  • The role of diastolic pump flow in centrifugal blood pump hemodynamics.

    abstract::We tried to verify the hypothesis that increases in pump flow during diastole are matched by decreases in left ventricular (LV) output during systole. A calf (80 kg) was implanted with an implantable centrifugal blood pump (EVAHEART, SunMedical Technology Research Corp., Nagano, Japan) with left ventricle to aorta (LV...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2001.06864.x

    authors: Akimoto T,Litwak KN,Yamazaki K,Litwak P,Kihara SI,Tagusari O,Yamazaki SI,Kameneva MV,Watach MJ,Umezu M,Tomioka J,Kormos RL,Koyanagi H,Griffith BP

    更新日期:2001-09-01 00:00:00

  • Prolonged left ventricular dysfunction induced by sequential multifocal ischemic infarcts in dogs.

    abstract::A method of creating multifocal ischemia in animals leading to left ventricular (LV) functional impairment is described. In a series of 10 mongrel dogs, electrodes were implanted in multiple branches of the coronary arteries. Subsequently, in seven animals, an 800-microA anodal current was applied for 3 h repeatedly o...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1984.tb04321.x

    authors: Polanski J,Mandell G,Wasfie T,Freed PS,Yoshizu H,Stein PD,Sabbah HN,Kantrowitz A

    更新日期:1984-11-01 00:00:00

  • Numerical Simulation of Nonpulsatile Left Ventricular Bypass.

    abstract::A computer simulation was carried out to investigate the influence of nonpulsatile left ventricular assistance on hemodynamics. A simulation circuit was constructed to represent the circulatory system. A source of current was added to denote the nonpulsatile blood pump. The left and right ventricles were replaced by v...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1996.tb04494.x

    authors: Mitsui N,Fukunaga S,Koura Y,Morita S,Hotei H,Sueshiro M,Sueda T,Matsuura Y

    更新日期:1996-05-01 00:00:00

  • Balloon Dilatation for Removal of an Irretrievable Permanent Hemodialysis Catheter: The Safest Approach.

    abstract::Long-term hemodialysis catheter dwell time in the central vein predisposes to fibrin sheath development, which subsequently causes catheter malfunction or occlusion. In very rare cases, the catheter can be overgrown with fibrin and rigidly connected with the vein or heart structures. This makes its removal almost impo...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12643

    authors: Garcarek J,Gołębiowski T,Letachowicz K,Kusztal M,Szymczak M,Madziarska K,Jakuszko K,Zmonarski S,Guziński M,Weyde W,Klinger M

    更新日期:2016-05-01 00:00:00

  • Reciprocal influences between ambulatorial peritoneal dialysis and pulmonary function.

    abstract::The aim of this study was to verify if dialysis solution volumes used in patients on continuous ambulatory peritoneal dialysis (CAPD) interfere with pulmonary function and if the pulmonary volumes interfere with the lymphatic absorption of the peritoneal cavity. We submitted 10 CAPD patients with a mean age of 48 +/- ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2001.06904.x

    authors: Marmanillo CG,Pecoits-Filho RF,Romão JE Jr,Kakehashi ET,Sabbaga E,Marcondes M,Abensur H

    更新日期:2001-11-01 00:00:00

  • Venoarterial extracorporeal membrane oxygenation for postcardiotomy cardiogenic shock-A six-year service evaluation.

    abstract::Only a small number of English hospitals provide postcardiotomy venoarterial extracorporeal membrane oxygenation (VA-ECMO) and there are doubts about its efficacy and safety. The aim of this service evaluation was to determine local survival rates and report on patient demographics. This was a retrospective service ev...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13647

    authors: Charlesworth M,Garcia M,Head L,Barker JM,Ashworth AD,Barnard JB,Feddy L,Venkateswaran RV

    更新日期:2020-07-01 00:00:00

  • Changes in Spirometry After Left Ventricular Assist Device Implantation.

    abstract::Left ventricular assist devices (LVADs) are increasingly being used as life-saving therapy in patients with end-stage heart failure. The changes in spirometry following LVAD implantation and subsequent unloading of the left ventricle and pulmonary circulation are unknown. In this study, we explored long-term changes i...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12507

    authors: Mohamedali B,Bhat G,Yost G,Tatooles A

    更新日期:2015-12-01 00:00:00

  • The compliance problem: a major obstacle in the development of implantable blood pumps.

    abstract::The compliance problem represents a major obstacle in the development of implantable blood pumps. The motor-driven pumps are enclosed in an airtight casing with gas in the motor space. The trapped gas in the motor space either increases the load on the motor during systole or impedes blood sac filling. Potential solut...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1984.tb04248.x

    authors: Lee S,Rosenberg G,Donachy JH,Wisman CB,Pierce WS

    更新日期:1984-02-01 00:00:00

  • A clinical monitoring system for centrifugal blood pumps.

    abstract::In clinical application of rotary blood pumps, flow obstruction as a result of suction of the inflow cannula, kinking of tubing, or thrombus formation occurs quite frequently. Early detection of such problems is essential to avoid hemolysis, tissue degradation, or release of thrombi to the patient. A program was devel...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1995.tb02409.x

    authors: Holzer S,Scherer R,Schmidt C,Schwendenwein I,Wieselthaler G,Noisser R,Schima H

    更新日期:1995-07-01 00:00:00

  • A novel in vitro assessment of tissue valve calcification by a continuous flow type method.

    abstract::A dynamic flow type testing to study calcification was self-designed to investigate calcification in bioprosthetic heart valves. The apparatus consists of a container into which leaflets from a porcine aortic valve are placed, a chamber that contains calcium solution, and a peristaltic pump that provides a continuous ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06482-2.x

    authors: Park JC,Hwang YS,Han DW,Suh H

    更新日期:2000-02-01 00:00:00

  • Paracorporeal artificial heart in postoperative heart failure.

    abstract::A pneumatically driven artificial heart with a tubular silicone rubber membrane and disc valves was used for functional heart replacement in the paracorporeal mode. A fluidic drive system allows adjustment of the heart rate, positive and negative pressures and systole/diastole ratio. Since August, 1977, the artificial...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1978.tb03465.x

    authors: Turina MT,Bosio R,Senning A

    更新日期:1978-08-01 00:00:00

  • Evidence of absence of porcine endogenous retrovirus (PERV) infection in patients treated with a bioartificial liver support system.

    abstract::Porcine endogenous retrovirus (PERV) genomes are present in all pig cells. In this retrospective study, we assessed PERV infectivity in 28 patients treated with an extracorporeal bioartificial liver (HepatAssist system) that includes a membrane device containing porcine hepatocytes. All patients tested negative for PE...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06444.x

    authors: Pitkin Z,Mullon C

    更新日期:1999-09-01 00:00:00

  • A new smartphone-based method for wound area measurement.

    abstract::Proper wound healing can be assessed by monitoring the wound surface area. Its reduction by 10 or 50% should be achieved after 1 or 4 weeks, respectively, from the start of the applied therapy. There are various methods of wound area measurement, which differ in terms of the cost of the devices and their accuracy. Thi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12169

    authors: Foltynski P,Ladyzynski P,Wojcicki JM

    更新日期:2014-04-01 00:00:00

  • Tissue-engineered skin containing mesenchymal stem cells improves burn wounds.

    abstract::There is increasing evidence showing that adult stem cells are useful for tissue regeneration. Bone marrow mesenchymal stem cells (MSCs) are self-renewing and are potent in differentiating into multiple cells and tissues. To investigate the practicability of repairing burn wounds with tissue-engineered (TE) skin combi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00654.x

    authors: Liu P,Deng Z,Han S,Liu T,Wen N,Lu W,Geng X,Huang S,Jin Y

    更新日期:2008-12-01 00:00:00

  • Survival of patients on chronic hemodialysis: single center experience.

    abstract::Patient survival from our hemodialysis (HD) center over the past 11 years was analyzed. Four hundred four patients, 212 female and 192 male, were treated by chronic intermittent HD. Patients were offered standard acetate-cellulosic membranes of 1.0-1.3 m2. During this period 181 patients died. One hundred three patien...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06291.x

    authors: Polenakovik M,Sikole A,Stojcev N,Spasovski G,Amitov V,Nikolov V,Masin G,Klinkmann H

    更新日期:1999-01-01 00:00:00

  • Assessment of skeletal muscle ventricle tissue blood flow using positron emission tomography.

    abstract::In this pilot study, we assessed the feasibility of using positron emission tomography (PET) imaging for in vivo measurement of skeletal muscle ventricle (SMV) tissue blood flow. In 4 dogs, with SMVs prepared from their latissimus dorsi muscle, we quantified SMV tissue blood flow by PET and related it to the tissue fl...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors: Singh TP,Greer K,Muzik O,Hammond RL,Stephenson LW,Di Carli MF

    更新日期:2001-04-01 00:00:00

  • Effectiveness of a New Single-Needle Single-Pump Dialysis System with Simultaneous Monitoring of Dialysis Dose.

    abstract::To date, single-needle (SN) hemodialysis (HD) requires a dialysis machine equipped with two blood pumps-one controlling arterial blood flow (Qb) and one controlling venous Qb. B. Braun has developed an innovative single-pump SN HD system. Therefore, usability is improved by reducing complexity. The aim of this study w...

    journal_title:Artificial organs

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/aor.13149

    authors: Bieser W,Welsch M,Jakob M,Meibaum J,Rodriguez DA,Wolff H,Marcelli D,Barth C

    更新日期:2018-08-01 00:00:00

  • Estimation of the native cardiac output from a rotary blood pump flow: in vitro study.

    abstract::The rotary blood pump will be an implantable left ventricular assist device (LVAD) in the near future. However, the best control method and the interrelationship between the rotary blood pump and native heart functions are unclear. An estimation was made of the native heart cardiac output from the change of an LVAD's ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.06127.x

    authors: Nakata K,Ohashi Y,Tayama E,Ohtsuka G,Takami Y,Mueller J,Glueck J,Nosé Y

    更新日期:1998-05-01 00:00:00

  • Development of a composite degradable/nondegradable tissue-engineered vascular graft.

    abstract::The present study aimed to determine the feasibility of constructing a reinforced autologous vascular graft by combining the advantages of fibrin gel as an autologous cell carrier material with the inherent mechanical strength of an integrated mesh structure. It was hypothesized that the mesh and dynamic culture condi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00601.x

    authors: Tschoeke B,Flanagan TC,Cornelissen A,Koch S,Roehl A,Sriharwoko M,Sachweh JS,Gries T,Schmitz-Rode T,Jockenhoevel S

    更新日期:2008-10-01 00:00:00

  • Electrical pulse train and single pulse stimulation of the small intestine: acute and chronic studies in the dog.

    abstract::In vitro tests have shown that electric currents may lead either to relaxation or contraction of the bowel wall. Because voluntary changes of the intestinal motility could be useful in the treatment of intestinal disorders, we investigated the reactions elicited by electrostimulation of the small intestine in the inta...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1989.tb02846.x

    authors: Moritz A,Grundfest-Broniatowski S,Ilyes L,Kasick J,Jacobs G,Olsen E,Nosé Y

    更新日期:1989-04-01 00:00:00

  • First experiences with outpatient care of patients with implanted axial flow pumps.

    abstract::As known from patients with pulsatile ventricular assist devices (VADs), early mobilization, physical exercise, and return to normal life are essential for optimal recovery. Recently, implantable rotary pumps became available for extended left ventricular support as bridges to transplantation. Modified procedures are ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2001.025005331.x

    authors: Wieselthaler GM,Schima H,Dworschak M,Quittan M,Nuhr M,Czerny M,Seebacher G,Huber L,Grimm M,Wolner E

    更新日期:2001-05-01 00:00:00

  • Hantaan virus infection with acute renal failure.

    abstract::We report on 10 patients with acute renal involvement in Hantaan virus infection observed at the Department of Nephrology, Faculty of Medicine, Skopje, Republic of Macedonia, during a period of 3 years (October 1987-July 1990). Eight patients were male and 2 were female, aged 37.5 +/- 4.8 years. The diagnosis of Hanta...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1525-1594.1995.tb02432.x

    authors: Polenaković M,Grcevska L,Gerasimovska-Tanevska V,Oncevski A,Dzikova S,Cakalaroski K,Masin G

    更新日期:1995-08-01 00:00:00

  • Hepatocyte culture between woven capillary networks: a microscopy study.

    abstract::A multi-compartment capillary membrane culture model with independently perfused three-dimensionally woven capillaries was developed for immobilization of hepatocytes in bioreactors. This enables spatial restructuring of cells and enhanced mass transfer performance with more efficient oxygenation and metabolite exchan...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1994.tb02181.x

    authors: Gerlach J,Schnoy N,Smith MD,Neuhaus P

    更新日期:1994-03-01 00:00:00

  • Promigratory activity of oxytocin on umbilical cord blood-derived mesenchymal stem cells.

    abstract::Recent studies show that oxytocin has various effects on cellular behaviors. Oxytocin is reported to stimulate cardiomyogenesis of embryonic stem cells and endothelial cell proliferation. Mesenchymal stem cells (MSCs) are widely used for cardiac repair, and we elucidated the effect of oxytocin on umbilical cord derive...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00894.x

    authors: Kim YS,Kwon JS,Hong MH,Kim J,Song CH,Jeong MH,Cho JG,Park JC,Kang JC,Ahn Y

    更新日期:2010-06-01 00:00:00

  • Numerical modeling of blood flow in the ventricular cavity of the artificial heart.

    abstract::The flow of blood as a viscous, Newtonian, incompressible liquid in an expanding spherical cavity with a ball-type inlet valve was examined. This type of flow can serve as a model of the phase of ventricular diastole in a sac-type artificial heart. The critical values of Reynolds numbers at which flow interruption beh...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1983.tb04170.x

    authors: Starobin IM,Zaĭko VM

    更新日期:1983-02-01 00:00:00

  • Serum hyaluronic acid and interleukin-6 as possible markers of carpal tunnel syndrome in chronic hemodialysis patients.

    abstract::To elucidate the precise mechanism of carpal tunnel syndrome (CTS), serum hyaluronic acid (HA), interleukin-1 beta (IL-1 beta), interleukin-6 (IL-6), and tumor necrosis factor-alpha (TNF-alpha) were measured in 71 chronic hemodialysis patients with or without CTS and/or shoulder pain. Patients were divided into two gr...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1994.tb02227.x

    authors: Takasu S,Takatsu S,Kunitomo K,Kokumai Y

    更新日期:1994-06-01 00:00:00

  • Techniques for optimization of pulsatile ventricular assist device support.

    abstract::For some time now researchers have argued the efficacy of pulsatile versus nonpulsatile hemodynamic support. Pulsatile systems, while providing a more physiological pumping source, are burdened with a multiparametric output function that can greatly affect the utility of such ventricular assist device (VAD) support. A...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1992.tb00299.x

    authors: Mills TC,Ott RA

    更新日期:1992-04-01 00:00:00