Estimation of the native cardiac output from a rotary blood pump flow: in vitro study.

Abstract:

:The rotary blood pump will be an implantable left ventricular assist device (LVAD) in the near future. However, the best control method and the interrelationship between the rotary blood pump and native heart functions are unclear. An estimation was made of the native heart cardiac output from the change of an LVAD's outflow waveform. The mock circulation loop was composed of an aortic compliance chamber, left arterial chamber, total artificial heart as a native heart, and a rotary blood pump that was placed as an LVAD with left ventricular drainage. The fast Fourier transform (FFT) technique was utilized to analyze the LVAD's outflow waveform and calculate the pulse power index (PPI) to examine a relation between the PPI and total artificial heart (TAH) output. The PPI increased with the increase of the TAH output; there was a positive correlation, and there was an inverse correlation between the PPI and the assist ratio. From this viewpoint, an estimation of the pulsatility change of the LVAD's outflow wave may indicate the native cardiac output.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Nakata K,Ohashi Y,Tayama E,Ohtsuka G,Takami Y,Mueller J,Glueck J,Nosé Y

doi

10.1046/j.1525-1594.1998.06127.x

subject

Has Abstract

pub_date

1998-05-01 00:00:00

pages

411-3

issue

5

eissn

0160-564X

issn

1525-1594

journal_volume

22

pub_type

杂志文章
  • Severe meprobamate intoxication treated by hemoperfusion over amberlite resin.

    abstract::A 36-year-old female was treated successfully by hemoperfusion over Amberlite XAD-4 resin after ingestion of 40 gm of meprobamate. Hemoperfusion was started five hours after the ingestion. At that time the patient was in deep coma. The patient was treated by hemoperfusion for five hours, at the end of which time she w...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors: Freund LG

    更新日期:1981-02-01 00:00:00

  • Balloon Dilatation for Removal of an Irretrievable Permanent Hemodialysis Catheter: The Safest Approach.

    abstract::Long-term hemodialysis catheter dwell time in the central vein predisposes to fibrin sheath development, which subsequently causes catheter malfunction or occlusion. In very rare cases, the catheter can be overgrown with fibrin and rigidly connected with the vein or heart structures. This makes its removal almost impo...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12643

    authors: Garcarek J,Gołębiowski T,Letachowicz K,Kusztal M,Szymczak M,Madziarska K,Jakuszko K,Zmonarski S,Guziński M,Weyde W,Klinger M

    更新日期:2016-05-01 00:00:00

  • Evaluation of chitosan-alginate-hyaluronate complexes modified by an RGD-containing protein as tissue-engineering scaffolds for cartilage regeneration.

    abstract::In this study, a series of natural biodegradable materials in the form of chitosan (C)-alginate (A)-hyaluronate (H) complexes are evaluated as tissue-engineering scaffolds. The weight ratio of C/A is 1 : 1 or 1 : 2. Sodium hyaluronate is mixed in 2%. The complexes can be cast into films or fabricated as scaffolds. The...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2004.00046.x

    authors: Hsu SH,Whu SW,Hsieh SC,Tsai CL,Chen DC,Tan TS

    更新日期:2004-08-01 00:00:00

  • Selective removal of anti-acetylcholine receptor antibodies and IgG in vitro with an immunoadsorbent containing immobilized sulfathiazole.

    abstract::Adsorption therapy, which treats the autoimmune disease by the selective removal of pathogenic substances from the blood, is an active subject. In this therapy, bioactive molecules such as antigen, antibodies and protein A are usually used as affinity-ligands. The disadvantages of using these substances as affinity-li...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1990.tb02977.x

    authors: Yamamoto Y,Sameshima T,Akaike T

    更新日期:1990-10-01 00:00:00

  • Magnesium homeostasis in patients undergoing continuous ambulatory peritoneal dialysis: role of the dialysate magnesium concentration.

    abstract::We carried out this retrospective study to examine the magnesium status of our chronic ambulatory peritoneal dialysis (CAPD) patients dialyzed with 0.75 mmol/L (group I) or 0.50 mmol/L (group II) magnesium peritoneal dialysis solution. A total of 34 anuric patients on CAPD (age:31-72 years; duration of CAPD:7-74 month...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2003.07193.x

    authors: Katopodis KP,Koliousi EL,Andrikos EK,Pappas MV,Elisaf MS,Siamopoulos KC

    更新日期:2003-09-01 00:00:00

  • Bone marrow combined with dental bud cells promotes tooth regeneration in miniature pig model.

    abstract::Growth factors and morphogens secreted by bone marrow mesenchymal stem cells (BMSCs) of bone marrow fluid may promote tooth regeneration. Accordingly, a tissue engineering approach was utilized to develop an economical strategy for obtaining the growth factors and morphogens from BMSCs. Unerupted second molar tooth bu...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2010.01064.x

    authors: Kuo TF,Lin HC,Yang KC,Lin FH,Chen MH,Wu CC,Chang HH

    更新日期:2011-02-01 00:00:00

  • Dialyzer reuse: interaction between dialyzer membrane, disinfectant (formalin), and blood during dialyzer reprocessing.

    abstract::The growing practice of dialyzer reuse in recent years is mainly based on medical and economic considerations. However, adverse reactions such as immunohemolytic anemia due to anti-Nform antibody associated with dialyzer reuse have been reported. In this study, scanning electron microscopy and cytologic staining were ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1996.tb04418.x

    authors: Ng YY,Yang AH,Wong KC,Lan HY,Hung TL,Kerr PG,Huang TP

    更新日期:1996-01-01 00:00:00

  • The human genome efforts and the cDNA project.

    abstract::Molecular biology has been moving swiftly toward clarifying the entire genome of organisms, including human. The human genome efforts that promote this transaction are characterized by the large-scale, high throughput production of data about the structure of the genome of the molecular level and its computer-assisted...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1111/j.1525-1594.1996.tb04553.x

    authors: Matsubara K

    更新日期:1996-08-01 00:00:00

  • Low molecular weight heparin versus unfractioned heparin for anticoagulation during perioperative extracorporeal membrane oxygenation: A single center experience in 102 lung transplant patients.

    abstract::Extracorporeal membrane oxygenation (ECMO) is gaining importance in the perioperative management of lung transplant patients. To date, the ideal substance for anticoagulation of ECMO patients is still a matter of debate. In this study, we describe our experience with the use of low molecular weight heparin (LMWH) in c...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13642

    authors: Gratz J,Pausch A,Schaden E,Baierl A,Jaksch P,Erhart F,Hoetzenecker K,Wiegele M

    更新日期:2020-06-01 00:00:00

  • The microsystems based visual prosthesis for optic nerve stimulation.

    abstract::The microsystems based visual prosthesis (MiViP) visual prosthesis generates visual perceptions well below safety and stimulator saturation limits. These perceptions, called phosphenes, are of reasonably small size and are broadly distributed in the visual field. They can thus be used to convey useful visual informati...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2002.06939.x

    authors: Delbeke J,Wanet-Defalque MC,Gérard B,Troosters M,Michaux G,Veraart C

    更新日期:2002-03-01 00:00:00

  • The application of immobilized enzymes in an artificial liver support system.

    abstract::A novel method of extracorporeal support for fulminant liver failure is reported whereby the most important detoxification processes of the liver are reproduced in an enzyme reactor. Most of the endogenous toxins involved in hepatic coma can be deactivated directly by conjugation with a hydrophilic residue such as glu...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1979.tb03801.x

    authors: Brunner G,Holloway CJ,Lösgen H

    更新日期:1979-02-01 00:00:00

  • Fluid-Structure Interactions Analysis of Shear-Induced Modulation of a Mesenchymal Stem Cell: An Image-Based Study.

    abstract::Although effects of biochemical modulation of stem cells have been widely investigated, only recent advances have been made in the identification of mechanical conditioning on cell signaling pathways. Experimental investigations quantifying the micromechanical environment of mesenchymal stem cells (MSCs) are challengi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12547

    authors: Ghaemi RV,Vahidi B,Sabour MH,Haghighipour N,Alihemmati Z

    更新日期:2016-03-01 00:00:00

  • Can the human lumbar posterior columns be stimulated by transcutaneous spinal cord stimulation? A modeling study.

    abstract::Stimulation of different spinal cord segments in humans is a widely developed clinical practice for modification of pain, altered sensation, and movement. The human lumbar cord has become a target for modification of motor control by epidural and, more recently, by transcutaneous spinal cord stimulation. Posterior col...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2011.01213.x

    authors: Danner SM,Hofstoetter US,Ladenbauer J,Rattay F,Minassian K

    更新日期:2011-03-01 00:00:00

  • A reduced priming system.

    abstract::Cardiopulmonary bypass (CPB), an integral part of valve surgery, is known to cause hemodilution, which can lead to a need for blood transfusion as well as a systemic inflammatory reaction. Our aim was to evaluate a reduced priming (RP) system for CPB with regard to clinical outcomes in patients undergoing valve surger...

    journal_title:Artificial organs

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/j.1525-1594.2006.00275.x

    authors: Sato K,Namura O,Sogawa M,Shimada K,Tosaka Y,Hayashi J

    更新日期:2006-08-01 00:00:00

  • Preservation of human saphenous vein against reactive oxygen species-induced oxidative stress by green tea polyphenol pretreatment.

    abstract::The injurious effects of reactive oxygen species on venous tissues and the potential protective role played by green tea polyphenol (GTPP) on human saphenous veins were investigated. Oxidative stress was induced exogenously in the vein segments, either by adding 0.8 or 1.6 M of H2O2, or by using 80 or 160 U/L of xanth...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2003.07163.x

    authors: Han DW,Suh H,Park YH,Cho BK,Hyon SH,Park JC

    更新日期:2003-12-01 00:00:00

  • Peritoneal dialysis solutions for the 21st century.

    abstract::Existing peritoneal dialysis (PD) solutions were formulated for the maintenance of fluid and electrolyte balance, correction of metabolic acidosis, and the removal of metabolic waste products. Solutions currently in development are designed to improve biocompatibility by neutralizing pH and reducing glucose degradatio...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1046/j.1525-1594.1998.06022.x

    authors: Martis L,Chen C,Moberly JB

    更新日期:1998-01-01 00:00:00

  • Changes in Spirometry After Left Ventricular Assist Device Implantation.

    abstract::Left ventricular assist devices (LVADs) are increasingly being used as life-saving therapy in patients with end-stage heart failure. The changes in spirometry following LVAD implantation and subsequent unloading of the left ventricle and pulmonary circulation are unknown. In this study, we explored long-term changes i...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12507

    authors: Mohamedali B,Bhat G,Yost G,Tatooles A

    更新日期:2015-12-01 00:00:00

  • Device exchange versus nonexchange modalities in left ventricular assist device-specific infections: A systematic review and meta-analysis.

    abstract::No standardized treatment algorithm exists for the management of continuous-flow left ventricular assist device (CF-LVAD)-specific infections. The aim of this systematic review and meta-analysis was to compare the outcomes of CF-LVAD-specific infections as managed by device exchange to other treatment modalities not i...

    journal_title:Artificial organs

    pub_type: 杂志文章,meta分析

    doi:10.1111/aor.13378

    authors: Bauer TM,Choi JH,Luc JGY,Weber MP,Moncho Escrivá E,Patel S,Maynes EJ,Boyle AJ,Samuels LE,Entwistle JW,Morris RJ,Massey HT,Tchantchaleishvili V

    更新日期:2019-05-01 00:00:00

  • Flow pattern analysis of the Baylor total artificial heart.

    abstract::To obtain an optimal design of the left blood chamber of the total artificial heart (TAH), flow visualization studies were performed. Information on velocities in critical areas of the left chamber was gathered using sectional pulsed laser light. The flow patterns on the entire pumping duration were photographed frame...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1994.tb03345.x

    authors: Meier D,Wernicke JT,Orime Y,Takatani S,Tasai K,Damm G,Naito K,Mizuguchi K,Makinouchi K,Glueck J

    更新日期:1994-12-01 00:00:00

  • Is the New Infant Jarvik 2015 Suitable for Patients

    abstract::Our aim was to study the feasibility of implanting the Infant Jarvik 2015 in patients weighing less than 8 kg. The Infant Jarvik 2015 left ventricular assist device (LVAD) was tested in a hybrid simulator of the cardiovascular system reproducing specific patients' hemodynamics for different patient weights (2-7 kg). F...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13302

    authors: Di Molfetta A,Zielinski K,Ferrari G,Kozarski M,Okrzeja P,Iacobelli R,Filippelli S,Perri G,Darowski M,Massetti M,Jarvik R,Amodeo A

    更新日期:2019-01-01 00:00:00

  • Miniaturized centrifugal ventricular assist device for bridge to decision: Preclinical chronic study in a bovine model.

    abstract::We developed a novel miniaturized extracorporeal centrifugal pump "BIOFLOAT NCVC (Nipro Corporation Osaka, Japan) as a ventricular assist device (VAD) and performed a preclinical study that is part of the process for its approval as a bridge to decision by the pharmaceutical and medical device agencies. The aim of thi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13459

    authors: Shimamura J,Mizuno T,Takewa Y,Tsukiya T,Naito N,Akiyama D,Iizuka K,Katagiri N,Nishimura T,Ono M,Tatsumi E

    更新日期:2019-09-01 00:00:00

  • Formation of Blood Foam in the Air Trap During Hemodialysis Due to Insufficient Automatic Priming of Dialyzers.

    abstract::We were encouraged to investigate the reasons for large amounts of foam observed in bloodlines during hemodialysis (HD). Foam was visible in the venous air trap within the Artis Gambro dialysis device. Estimates of the extent of foam were graded (0-no foam, 10-extensive foam) by two persons that were blind to the type...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13070

    authors: Jonsson P,Lindmark L,Axelsson J,Karlsson L,Lundberg L,Stegmayr B

    更新日期:2018-05-01 00:00:00

  • LDL apheresis: a novel technique (LIPOCOLLECT 200).

    abstract::Therapeutic means to lower Lp(a) are limited. The most effective method to reduce plasma Lp(a) concentration significantly is therapeutic apheresis, namely, low-density lipoprotein (LDL) lipoprotein(a) (Lp(a)) apheresis. A novel technique based on reusable LDL adsorber called Lipocollect 200 (Medicollect, Rimbach, Ger...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00959.x

    authors: Stefanutti C,Di Giacomo S,Mazzarella B,Castelli A

    更新日期:2009-12-01 00:00:00

  • The PediPump: a new ventricular assist device for children.

    abstract::Options for mechanical circulatory support for the treatment of end-stage heart failure in children are limited. Ventricular assist devices (VADs), which have revolutionized cardiac care in adults, remain largely unavailable for pediatric applications. The PediPump is a new rotary dynamic VAD designed to provide suppo...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2005.29088.x

    authors: Duncan BW,Lorenz M,Kopcak MW,Fukamachi K,Ootaki Y,Chen HM,Chapman PA,Davis SJ,Smith WA

    更新日期:2005-07-01 00:00:00

  • Assessment of skeletal muscle ventricle tissue blood flow using positron emission tomography.

    abstract::In this pilot study, we assessed the feasibility of using positron emission tomography (PET) imaging for in vivo measurement of skeletal muscle ventricle (SMV) tissue blood flow. In 4 dogs, with SMVs prepared from their latissimus dorsi muscle, we quantified SMV tissue blood flow by PET and related it to the tissue fl...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors: Singh TP,Greer K,Muzik O,Hammond RL,Stephenson LW,Di Carli MF

    更新日期:2001-04-01 00:00:00

  • Flow balance between the left and right cardiac output of an eccentric roller type total artificial heart.

    abstract::We have made an eccentric roller type total artificial heart (ERTAH). The ERTAH is a positive-displacement device comparable to a DeBakey roller pump. Its left and right outputs are determined by the size of its blood chambers, and the ratio of its left and right output is almost constant. We focused on an interatrial...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06414.x

    authors: Wada H,Fukunaga S,Watari M,Sakai H,Sugawara Y,Ochikubo H,Imai K,Shibamura H,Orihashi K,Sueda T,Matsuura Y

    更新日期:1999-08-01 00:00:00

  • Modeling of a rotary blood pump.

    abstract::The accurate representation of rotary blood pumps in a numerical environment is important for meaningful investigation of pump-cardiovascular system interactions. Although numerous models for ventricular assist devices (VADs) have been developed, modeling methods for rotary total artificial hearts (rTAHs) are still re...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12142

    authors: Nestler F,Bradley AP,Wilson SJ,Timms DL

    更新日期:2014-03-01 00:00:00

  • An image processing approach for blind mobility facilitated through visual intracortical stimulation.

    abstract::This article presents an image processing approach dedicated for a blind mobility aid facilitated through visual intracortical electrical stimulation. The method examines a display framework based on the distances related to a scene. The distances of objects to the walker are measured using a size perspective method w...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2011.01421.x

    authors: Mohammadi HM,Ghafar-Zadeh E,Sawan M

    更新日期:2012-07-01 00:00:00

  • Application of computational fluid dynamics techniques to blood pumps.

    abstract::Present-day computational fluid dynamics (CFD) techniques can be used to analyze the behavior of fluid flow in a variety of pumps. CFD can be a powerful tool during the design stage for rapid virtual prototyping of different designs, analyzing performance parameters, and making design improvements. Computational flow ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors: Sukumar R,Athavale MM,Makhijani VB,Przekwas AJ

    更新日期:1996-06-01 00:00:00

  • Cytotoxicity and genotoxicity of bovine pericardium preserved in glycerol.

    abstract::Bovine pericardium is a widely utilized biomaterial. Usually, after harvesting, it is advantageous that the pericardium be immersed in glycerol to improve its shelf life. This can induce some degree of toxicity in the material. The studies were performed in compliance with the rules of ISO 10993 and OECD 487, in the b...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00542.x

    authors: Rodas AC,Maizato MJ,Leirner AA,Pitombo RN,Polakiewicz B,Beppu MM,Higa OZ

    更新日期:2008-04-01 00:00:00