Peritoneal dialysis solutions for the 21st century.

Abstract:

:Existing peritoneal dialysis (PD) solutions were formulated for the maintenance of fluid and electrolyte balance, correction of metabolic acidosis, and the removal of metabolic waste products. Solutions currently in development are designed to improve biocompatibility by neutralizing pH and reducing glucose degradation products. PD solutions developed for the 21st century will address major clinical needs related to the maintenance of adequate nutrition, improvement of cardiovascular comorbidity, preservation of peritoneal membrane function, and adequacy of dialysis. Nutrineal is the first example of a PD solution to address such a clinical need. Another example is a low sodium solution to improve sodium balance thereby reducing the incidence of hypertension and the need for antihypertensive medication. New solutions under investigation will employ additives to protect the peritoneal membrane during peritonitis and chronic PD and to optimize PD therapy via improvements in ultrafiltration and solute clearances. Examples include the use of antioxidants to reduce oxidative damage during peritonitis and the use of glycosaminoglycans or other additives to enhance ultrafiltration. Future concepts include remodeling of the peritoneum, for example, the use of mesothelial gene therapy to introduce metabolic and anabolic machinery to remove or perpetually recycle metabolic wastes. The 21st century promises to be an exciting and fruitful time for the investigation and development of new products for the improvement of PD therapy.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Martis L,Chen C,Moberly JB

doi

10.1046/j.1525-1594.1998.06022.x

subject

Has Abstract

pub_date

1998-01-01 00:00:00

pages

13-6

issue

1

eissn

0160-564X

issn

1525-1594

journal_volume

22

pub_type

杂志文章,评审
  • Eccentric roller type total artificial heart creating interatrial shunt.

    abstract::Creating an interatrial shunt to achieve left-right flow balance and modification of the blood chambers to improve the basic performance of the device were performed in developing an eccentric roller type total artificial heart (ERTAH). Smaller blood chambers reduce friction loss and increase durability and energy eff...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06602.x

    authors: Wada H,Fukunaga S,Watari M,Imai K,Sakai H,Shibamura H,Sueda T,Matsuura Y

    更新日期:2000-08-01 00:00:00

  • Is the dog a useful model for accelerated calcification study of cardiovascular bioprostheses?

    abstract::Chitosan posttreatment has been shown to be effective in prevention of calcification of the glutaraldehyde treated bovine pericardium when implanted subdermally in rats for 12 weeks. The efficacy of chitosan posttreatment in complete calcium mitigation of the glutaraldehyde treated porcine aortic valves implanted in t...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb00735.x

    authors: Chanda J,Kuribayashi R,Abe T,Sekine S,Shibata Y,Yamagishi I

    更新日期:1997-05-01 00:00:00

  • Dispersive aortic cannulas reduce aortic wall shear stress affecting atherosclerotic plaque embolization.

    abstract::Neurologic complications during on-pump cardiovascular surgery are often induced by mobilization of atherosclerotic plaques, which is directly related to enhanced wall shear stress. In the present study, we numerically evaluated the impact of dispersive aortic cannulas on aortic blood flow characteristics, with specia...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12359

    authors: Assmann A,Gül F,Benim AC,Joos F,Akhyari P,Lichtenberg A

    更新日期:2015-03-01 00:00:00

  • Rate of thrombus accumulation on intravenacaval IVOX devices explanted from human clinical trial patients with acute respiratory failure.

    abstract::The weight gain of IVOX devices removed from the first 49 human clinical trials patients after from 1 to 29 days of implantation into the venae caval blood stream has been assessed. Each patient had received sufficient systemic heparin to maintain activated clotting times between 150 and 200 s while the IVOX device wa...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1994.tb03329.x

    authors: Imai H,Schaap RN,Mortensen JD

    更新日期:1994-11-01 00:00:00

  • An advanced mock circulation loop for in vitro cardiovascular device evaluation.

    abstract::Controlled and repeatable in vitro evaluation of cardiovascular devices using a mock circulation loop (MCL) is essential prior to in vivo or clinical trials. MCLs often consist of only a systemic circulation with no autoregulatory responses and limited validation. This study aimed to develop, and validate against huma...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13636

    authors: Gregory SD,Pauls JP,Wu EL,Stephens A,Steinseifer U,Tansley G,Fraser JF

    更新日期:2020-06-01 00:00:00

  • The DeBakey ventricular assist device: current status in 1997.

    abstract::In 1993, the development began of a small axial flow blood pump, the DeBakey ventricular assist device (VAD). The material was recently converted to a titanium alloy, and a waterproof pump package was incorporated for long-term intracorporeal circulation. Thirteen intrathoracic implantations in calves were achieved. N...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1046/j.1525-1594.1999.06300.x

    authors: Tayama E,Olsen DB,Ohashi Y,Benkowski R,Morley D,Noon GP,Nosé Y,Debakey ME

    更新日期:1999-12-01 00:00:00

  • (13) C Breath Tests Are Feasible in Patients With Extracorporeal Membrane Oxygenation Devices.

    abstract::Temporary extracorporeal membrane oxygenation (ECMO) has been established as an essential part of therapy in patients with pulmonary or cardiac failure. As physiological gaseous exchange is artificially altered in this patient group, it is debatable whether a (13) C-breath test can be carried out. In this proof of tec...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12634

    authors: Bednarsch J,Menk M,Malinowski M,Weber-Carstens S,Pratschke J,Stockmann M

    更新日期:2016-07-01 00:00:00

  • A Meta-Analysis of Renal Function After Adult Cardiac Surgery With Pulsatile Perfusion.

    abstract::The aim of this meta-analysis was to determine whether pulsatile perfusion during cardiac surgery has a lesser effect on renal dysfunction than nonpulsatile perfusion after cardiac surgery in randomized controlled trials. MEDLINE, EMBASE, and the Cochrane Central Register of Controlled Trials were used to identify ava...

    journal_title:Artificial organs

    pub_type: 杂志文章,meta分析

    doi:10.1111/aor.12452

    authors: Nam MJ,Lim CH,Kim HJ,Kim YH,Choi H,Son HS,Lim HJ,Sun K

    更新日期:2015-09-01 00:00:00

  • The analysis of driving mode influence on energy dissipation in pneumatic artificial heart chambers.

    abstract::The energy dissipated in blood or on a total artificial heart (TAH) chamber's elements directly or indirectly decreases the biological or technical safety of the TAH's work. The energetic analysis of the Polish total artificial heart (POLTAH) external work with the objective of estimating the valve and membrane roles ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.05074.x

    authors: Nawrat Z,Malota Z

    更新日期:1998-10-01 00:00:00

  • Lipid apheresis: from a heroic treatment to routine clinical practice.

    abstract::Lipid apheresis has developed from a heroic treatment into a routine clinical therapy and currently is the major indication for performing extracorporeal plasma therapy. Whereas it was once reserved for patients with homozygous familial hypercholesterolemia, today it has a place in the secondary prevention of severe c...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1111/j.1525-1594.1996.tb04525.x

    authors: Bosch T

    更新日期:1996-05-01 00:00:00

  • Intrinsic coagulation pathway in end-stage renal disease associated with spinal cord injury treated with hemodialysis.

    abstract::Plasma procoagulant activities of factors XII, XI, IX, and VIII and plasma concentrations of factor XII antigen and high molecular weight kininogen (HMK) were determined in nine men with chronic renal failure (CRF) associated with long-standing spinal cord injury (SCI) treated with hemodialysis. The results were compa...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1985.tb04366.x

    authors: Vaziri ND,Winer RL,Toohey J,Danviriyasup K,Alikhani S,Eltorai I,Gordon S,Paule P

    更新日期:1985-05-01 00:00:00

  • Adverse events of subcutaneous recombinant human erythropoietin therapy: results of a controlled multicenter European study.

    abstract::In a controlled European multicenter study, clinical tolerance of subcutaneously administered recombinant human erythropoietin (rh-EPO) therapy and its influence on the course of illness in 362 hemodialyzed patients (162 males, 200 females) from 16 European dialysis centers was studied. Of these, 181 patients served a...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章,多中心研究,随机对照试验

    doi:10.1111/j.1525-1594.1993.tb00571.x

    authors: Klinkmann H,Wieczorek L,Scigalla P

    更新日期:1993-04-01 00:00:00

  • Demand for and use of functional electrical stimulation systems and conventional orthoses in the spinal lesioned community of the UK.

    abstract::The use of and demand for functional electrical stimulation (FES) systems and conventional orthoses in the spinal cord lesioned population was assessed. The assessment was conducted by a postal survey of the members of the spinal injury associations in the U.K. Out of all the respondents, only 2% had used an FES syste...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06361.x

    authors: Maxwell DJ,Granat MH,Baardman G,Hermens HJ

    更新日期:1999-05-01 00:00:00

  • Feasibility of extracorporeal on-line large-scale plasma adsorptions on protein A-sepharose columns in cancer patients.

    abstract::The feasibility of extracorporeal adsorption of 1.5-3 L plasma on protein A-Sepharose was investigated in six patients with advanced cancer. Anticoagulation with heparin was associated with respiratory distress syndrome in two patients, most likely caused by complement activation as indicated by a transient leukopenia...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1984.tb04247.x

    authors: Wallmark A,Grubb A,Freiburghaus C,Flodgren P,Husberg B,Lindholm T,Lindström C,Thysell H,Sjögren HO

    更新日期:1984-02-01 00:00:00

  • New immunosuppressive proteins (KX-2, -4, and -5) induced by liver transplantation.

    abstract::The presence in rat serum of three novel immunosuppressive proteins is associated with induction of tolerance after liver grafting. One of these, KX-5 (40 kilodalton molecular weight) is present 40-100 days after grafting of DA liver into PVG, a combination in which liver grafts are not rejected; two others, KX-2 (87 ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1996.tb00646.x

    authors: Kamada N

    更新日期:1996-10-01 00:00:00

  • Paper is a compatible bed for rat hepatocytes.

    abstract::To develop an effective hybrid bioartificial liver (BAL) device, the material of the scaffold is very important to support hepatocytes that have both growth ability and hepatic differentiated functions. In this study we used paper (Kimwipe, Kimberly-Clark Corp., Roswell, GA, U.S.A.) as a scaffold. Primary hepatocytes ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06506.x

    authors: Mizuguchi T,Mitaka T,Sato F,Mochizuki Y,Hirata K

    更新日期:2000-04-01 00:00:00

  • Determination of plasma C3a des Arg levels after blood contact with foreign surfaces.

    abstract::The products of complement activation, including C3a, C4a, C5a, and their des Arg derivatives, have been used by many investigators as indicators of blood or foreign surface bioincompatibility, e.g., during hemodialysis. One problem encountered is that after extracorporeal circulation over some dialysis membranes very...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1986.tb02518.x

    authors: Spencer PC,Schmidt B,Gurland HJ

    更新日期:1986-02-01 00:00:00

  • Comparison of four methods of cleaning hollow-fiber dialyzers for reuse.

    abstract::Four methods of cleaning hollow-fiber artificial kidneys (HFAKs) for reuse were compared in a prospective study. Each cleaning method was randomly assigned and HFAKs were reused until volume loss was greater than or equal to 15 ml, unless discarded for other reasons. HFAKs cleaned with 0.3 M sodium hydroxide averaged ...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1111/j.1525-1594.1986.tb02602.x

    authors: Dennis MB Jr,Vizzo JE,Cole JJ,Westendorf DL,Ahmad S

    更新日期:1986-12-01 00:00:00

  • General planning of an artificial organ center.

    abstract::There is an increasing need for research and development centers to deal with design and evaluation of organ replacement systems, the improvement of older devices, and the study of biocompatibility problems. Special attention, in this article, is focused on the determinant role of the background of the investigators i...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1989.tb01579.x

    authors: Vanholder R,Ringoir S

    更新日期:1989-12-01 00:00:00

  • Single axis controlled hybrid magnetic bearing for left ventricular assist device: hybrid core and closed magnetic circuit.

    abstract::In previous studies, we presented main strategies for suspending the rotor of a mixed-flow type (centrifugal and axial) ventricular assist device (VAD), originally presented by the Institute Dante Pazzanese of Cardiology (IDPC), Brazil. Magnetic suspension is achieved by the use of a magnetic bearing architecture in w...

    journal_title:Artificial organs

    pub_type: 杂志文章,多中心研究

    doi:10.1111/j.1525-1594.2011.01265.x

    authors: da Silva I,Horikawa O,Cardoso JR,Camargo FA,Andrade AJ,Bock EG

    更新日期:2011-05-01 00:00:00

  • Progress in the control system of the undulation pump total artificial heart.

    abstract::The undulation pump total artificial heart (UPTAH) is a small implantable total artificial heart. As the UPTAH generates outflow and inflow at the same time, control of the UPTAH is very difficult. Therefore suitable control methods specifically for the UPTAH should be established. Various motor control, left-right fl...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2003.07174.x

    authors: Saito I,Chinzei T,Abe Y,Ishimaru M,Mochizuki S,Ono T,Isoyama T,Iwasaki K,Kouno A,Baba A,Ozeki T,Takiura K,Tohyama T,Nakagawa H,Imachi K

    更新日期:2003-01-01 00:00:00

  • Ductular cholestasis, an unusual form of intrahepatic cholestasis, associated with cardiogenic shock and ventricular assist device.

    abstract::Ventricular assist devices have been shown to be effective in advanced heart failure selected patients. They often have borderline end-organ function, what facilitates organ dysfunction. Liver failure is difficult to manage and leads to increased morbidity and mortality. We report a case of ductular cholestasis, an un...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00760.x

    authors: Mohedano-Gómez A,Pérez-Vela JL,Renes-Carreño E,De-Andrés CI,Corres-Peiretti MA,Arribas-López P,Gutierrez-Rodriguez J,Perales-Rodríguez-De-Viguri N

    更新日期:2010-02-01 00:00:00

  • Changes in albumin/platelet interaction with an artificial surface--due to a antibiotics, pyridoxal phosphate, and lymphocytes.

    abstract::Protein adsorption and platelet adhesion are two important biological processes arising at the blood prosthetic interface. The effect of certain antibiotics, namely, neomycin, gentamicin, ampicillin, penicillin-G, and streptomycin to modulate the albumin polycarbonate surface interaction was investigated using 125I al...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1988.tb02747.x

    authors: Chandy T,Sharma CP

    更新日期:1988-04-01 00:00:00

  • Testosterone and hemoglobin in hemodialysis male and female patients.

    abstract::It has been speculated that testosterone stimulates erythropoiesis. We hypothesized that hemoglobin levels in hemodialysis (HD) patients are associated with serum testosterone concentrations. Testosterone, hemoglobin, and other biochemical parameters were measured in a representative sample of 98 chronic HD patients (...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12218

    authors: Ekart R,Taskovska M,Hojs N,Bevc S,Hojs R

    更新日期:2014-07-01 00:00:00

  • Hemodynamic evaluation of a new left ventricular assist device: an integrated cardioassist catheter as a pulsatile left ventricle-femoral artery bypass.

    abstract::We developed a new left ventricular (LV) assist catheter (transaortic valve from LV to femoral artery) that is implemented percutaneously and exerted as a synchronous pulsatile partial LV flow support with conventional intraaortic balloon pump (IABP) driving system and centrifugal pump system. We investigated whether ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1992.tb00311.x

    authors: Ide H,Yamaguchi A,Ino T,Matsumoto H,Fujimasa I

    更新日期:1992-06-01 00:00:00

  • Donkey pericardium compares favorably with commercial xenopericardia used in the manufacture of transcatheter heart valves.

    abstract::Transcatheter aortic valve implantation (TAVI) has gained considerable acceptance in the past decade due to its lower risks than conventional open-heart surgery. However, the deformation and delamination of the leaflets during the crimping procedure have raised questions about the durability and long-term serviceabili...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13503

    authors: Mao J,Rassoli A,Tong Y,Rouse EN,Le-Bel G,How D,Germain L,Fatouraee N,Zhang Z,Reed RR,Guidoin R

    更新日期:2019-10-01 00:00:00

  • Intravascular micropump for augmented liver perfusion: first in vivo experience.

    abstract::The aim of this study was to assess the in vivo performance of a new microaxial rotary blood pump developed for long-term intraportal implantation. The pump, measuring 7 mm in diameter, has a single stage impeller and is powered by a microelectric motor. The pump was implanted into the portal vein in 13 large white pi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2001.06772.x

    authors: Havlík R,Kerkhoffs W,Jiao LR,Schumacher O,Reul H,Habib N

    更新日期:2001-05-01 00:00:00

  • Development and characterization of a new stationary phase for an immunoadsorption wall.

    abstract::This study introduces a newly developed method for the formation of a stationary phase superficially embedded with immunoadsorbent, that is partially incomplete two-stage polymerization of acrylamide. Preliminary experimental studies show that binding activity of the immunoadsorbent was satisfactorily maintained after...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2005.29071.x

    authors: Yang TH

    更新日期:2005-05-01 00:00:00

  • Flow through an outlet cannula of a rotary ventricular assist device.

    abstract::Rotary ventricular assist devices (VADs) are primarily used during surgery and short-term postoperative assistance. There are issues involving the use of rotary VADs including the behavior of flow emanating from the assist device which might induce flow irregularities that could potentially lead to stroke or cerebrova...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2002.06931_4.x

    authors: Manning KB,Miller GE

    更新日期:2002-08-01 00:00:00

  • What Is the Optimal Setting for a Continuous-Flow Left Ventricular Assist Device in Severe Mitral Regurgitation?

    abstract::Excessive left ventricular (LV) volume unloading can affect right ventricular (RV) function by causing a leftward shift of the interventricular septum in patients with mitral regurgitation (MR) receiving left ventricular assist device (LVAD) support. Optimal settings for the LVAD should be chosen to appropriately cont...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12702

    authors: Naito N,Nishimura T,Takewa Y,Kishimoto S,Date K,Umeki A,Ando M,Ono M,Tatsumi E

    更新日期:2016-11-01 00:00:00