The PediPump: a new ventricular assist device for children.

Abstract:

:Options for mechanical circulatory support for the treatment of end-stage heart failure in children are limited. Ventricular assist devices (VADs), which have revolutionized cardiac care in adults, remain largely unavailable for pediatric applications. The PediPump is a new rotary dynamic VAD designed to provide support for the entire range of patient sizes encountered in pediatrics. Despite being much smaller than currently available VADs, which makes it suitable for even newborn circulatory support, the PediPump demonstrates excellent hemodynamic performance.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Duncan BW,Lorenz M,Kopcak MW,Fukamachi K,Ootaki Y,Chen HM,Chapman PA,Davis SJ,Smith WA

doi

10.1111/j.1525-1594.2005.29088.x

subject

Has Abstract

pub_date

2005-07-01 00:00:00

pages

527-30

issue

7

eissn

0160-564X

issn

1525-1594

pii

AOR29088

journal_volume

29

pub_type

杂志文章
  • Influence of growth hormone on maintenance of capillary-like structures in an in vitro model of stromal vascular tissue--results from morphometric analysis.

    abstract::The in vitro development of a vascular stroma might be a solution for the engineering of vascularized tissues, however, in vitro stability of capillary-like structures is limited. In order to test the influence on maintenance of capillary-like structures, human growth hormone (hGH) was added in concentrations of 0.5, ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2005.29057.x

    authors: Frerich B,Kurtz-Hoffmann J,Lindemann N

    更新日期:2005-04-01 00:00:00

  • Immunologic studies of hollow-fiber dialyzer extracts.

    abstract::Testing failed to detect free isocyanates in dialyzer rinses or significant levels of immunoglobulin E antibodies to isocyanate-protein conjugates in the serum of individuals reacting during hemodialysis with dialyzers containing Cuprophan membranes. Extended immunization of rabbits with Limulus lysate-reactive materi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1984.tb04298.x

    authors: Butcher BT,Reed MA,O'Neil CE,Leech S,Pearson FC

    更新日期:1984-08-01 00:00:00

  • Pathways for water absorption and physiological role of the lateral interspaces in the kidney tubule.

    abstract::Possible routes for water and salt flow and the most likely theories that describe coupling between water and salt flow across leaky epithelia are presented. The osmotic theories seem the most likely ones. However, several of the theories have weaknesses that render them unsatisfactory, in particular because of the po...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1111/j.1525-1594.1987.tb02713.x

    authors: Whittembury G,Carpi-Medina P,González E,Linares H

    更新日期:1987-12-01 00:00:00

  • Separation of the natural atria in experimental implantation of total artificial heart.

    abstract::Atrial connections in a single-unit total artificial heart (TAH) may be difficult to make because of the rigidity of the device and the fixed position of the atrial inlets. We developed a technique to separate the natural atrial borders in an experimental implantation of a unitary TAH. In this technique, the interatri...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1995.tb02442.x

    authors: Frazier OH,Matsuwaka R,Parnis SM,Furusho N,McGee MG,Fuqua JM

    更新日期:1995-08-01 00:00:00

  • An image processing approach for blind mobility facilitated through visual intracortical stimulation.

    abstract::This article presents an image processing approach dedicated for a blind mobility aid facilitated through visual intracortical electrical stimulation. The method examines a display framework based on the distances related to a scene. The distances of objects to the walker are measured using a size perspective method w...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2011.01421.x

    authors: Mohammadi HM,Ghafar-Zadeh E,Sawan M

    更新日期:2012-07-01 00:00:00

  • Estimation of the native cardiac output from a rotary blood pump flow: in vitro study.

    abstract::The rotary blood pump will be an implantable left ventricular assist device (LVAD) in the near future. However, the best control method and the interrelationship between the rotary blood pump and native heart functions are unclear. An estimation was made of the native heart cardiac output from the change of an LVAD's ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.06127.x

    authors: Nakata K,Ohashi Y,Tayama E,Ohtsuka G,Takami Y,Mueller J,Glueck J,Nosé Y

    更新日期:1998-05-01 00:00:00

  • Angiographic and pathological studies on regression of coronary atherosclerosis of FH patients who received LDL-apheresis treatment.

    abstract::We report on the most recent data confirming the angiographic and pathological efficacy of LDL-apheresis for coronary atherosclerosis of a familial hypercholesterolemia (FH) patient using collected data of a large number of cases and especially of one autopsy case. Changes in coronary artery stenosis have been assesse...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1992.tb00289.x

    authors: Koga N,Iwata Y,Yamamoto A

    更新日期:1992-04-01 00:00:00

  • Usability and safety of ventricular assist devices: human factors and design aspects.

    abstract::The purpose of this study was the investigation of the usability and ergonomics of ventricular assist devices (VADs) in everyday usage. Patients with four different VAD types were observed. After implantation, instruction, and discharge from the hospital, the patients returned on a regular basis to the outpatient clin...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00844.x

    authors: Geidl L,Zrunek P,Deckert Z,Zimpfer D,Sandner S,Wieselthaler G,Schima H

    更新日期:2009-09-01 00:00:00

  • Estimation of theophylline clearance during continuous arteriovenous hemofiltration.

    abstract::Pharmacologic agents and other non-protein-bound compounds smaller than 5,000 daltons have the potential to be removed by continuous arteriovenous hemofiltration (CAVH). A proposed method for estimating drug clearance by CAVH (ClCAVH) equates ultrafiltrate clearance to the product of the sieving coefficient and the av...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1990.tb02997.x

    authors: Horton MW,Godley PJ,Moore ES,Fineg J,Gillespie WR

    更新日期:1990-12-01 00:00:00

  • Dialyzer membranes: effect of surface area and chemical modification of cellulose on complement and platelet activation.

    abstract::Using an ex vivo model, the effects of membrane composition and surface area on both the complement system (as reflected by plasma C3a levels) and platelets [as indicated by plasma concentrations of thromboxane B2 (TXB2) and platelet factor 4 (PF4)] were studied. In this model, polyacrylonitrile (PAN) was associated w...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1987.tb02648.x

    authors: Mahiout A,Meinhold H,Kessel M,Schulze H,Baurmeister U

    更新日期:1987-04-01 00:00:00

  • Flow through an outlet cannula of a rotary ventricular assist device.

    abstract::Rotary ventricular assist devices (VADs) are primarily used during surgery and short-term postoperative assistance. There are issues involving the use of rotary VADs including the behavior of flow emanating from the assist device which might induce flow irregularities that could potentially lead to stroke or cerebrova...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2002.06931_4.x

    authors: Manning KB,Miller GE

    更新日期:2002-08-01 00:00:00

  • Preservation of human saphenous vein against reactive oxygen species-induced oxidative stress by green tea polyphenol pretreatment.

    abstract::The injurious effects of reactive oxygen species on venous tissues and the potential protective role played by green tea polyphenol (GTPP) on human saphenous veins were investigated. Oxidative stress was induced exogenously in the vein segments, either by adding 0.8 or 1.6 M of H2O2, or by using 80 or 160 U/L of xanth...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2003.07163.x

    authors: Han DW,Suh H,Park YH,Cho BK,Hyon SH,Park JC

    更新日期:2003-12-01 00:00:00

  • Heart valve inspired and multi-stream aortic cannula: Novel designs for cardiopulmonary bypass improvement in neonates.

    abstract::In a typical open-heart surgery, the blood flow through the aortic cannula is a critical element of the cardiopulmonary bypass (CPB) procedure. Especially for the neonatal and pediatric CPB flow conditions, the need for small hydraulic diameter and large blood flow results confined turbulent jet flow regimes that exac...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13462

    authors: Rasooli R,Pekkan K

    更新日期:2019-10-01 00:00:00

  • Computational fluid dynamics prediction of blood damage in a centrifugal pump.

    abstract::This study explores a quantitative evaluation of blood damage that occurs in a continuous flow left ventricular assist device due to fluid stress. Computational fluid dynamics (CFD) analysis is used to track the shear stress history of 388 particle streaklines. The accumulation of shear and exposure time is integrated...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2003.00026.x

    authors: Song X,Throckmorton AL,Wood HG,Antaki JF,Olsen DB

    更新日期:2003-10-01 00:00:00

  • Low molecular weight heparin versus unfractioned heparin for anticoagulation during perioperative extracorporeal membrane oxygenation: A single center experience in 102 lung transplant patients.

    abstract::Extracorporeal membrane oxygenation (ECMO) is gaining importance in the perioperative management of lung transplant patients. To date, the ideal substance for anticoagulation of ECMO patients is still a matter of debate. In this study, we describe our experience with the use of low molecular weight heparin (LMWH) in c...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13642

    authors: Gratz J,Pausch A,Schaden E,Baierl A,Jaksch P,Erhart F,Hoetzenecker K,Wiegele M

    更新日期:2020-06-01 00:00:00

  • Transcutaneous monitoring of blood gas tensions in patients on intermittent peritoneal dialysis.

    abstract::A relative contraindication to intermittent peritoneal dialysis (IPD) is chronic lung disease. To evaluate whether the instillation of 2 L of fluid into the peritoneal cavity affects respiratory function, five IPD patients were studied in the supine position during the first 4 h of a routine IPD session. Blood gas ten...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1988.tb02768.x

    authors: Korzets Z,Pomeranz A,Shachor Y,Bernheim J

    更新日期:1988-06-01 00:00:00

  • Controlled delivery of low-dose bone morphogenetic protein-2 using heparin-conjugated fibrin in the posterolateral lumbar fusion of rabbits.

    abstract::The heparin-conjugated fibrin (HCF) system has been developed to deliver bone morphogenetic proteins (BMPs) for a long-term period and thus enhance bone regeneration. In the present study, we tested the effectiveness of the delivery system for spinal fusion with a very low dose of BMP-2. A total of 15 rabbits underwen...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2012.01578.x

    authors: Koo KH,Lee JM,Ahn JM,Kim BS,La WG,Kim CS,Im GI

    更新日期:2013-05-01 00:00:00

  • Chronic animal experiment with magnetically suspended centrifugal pump.

    abstract::We have been developing a new type of centrifugal pump for long-term use. The magnetically suspended centrifugal pump (MSCP) contains no shaft and seal so that long life expectancy is predicted. Paracorporeal left ventricular (LV) assist circulation between the left atrium and the descending aorta was instituted using...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb03713.x

    authors: Yamada T,Nishimura K,Park CH,Kono S,Yuasa S,Tsukiya T,Akamatsu T,Matsuda K,Ban T

    更新日期:1997-07-01 00:00:00

  • Magnetic suspension of the rotor of a ventricular assist device of mixed flow type.

    abstract::This work presents results of preliminary studies concerning application of magnetic bearing in a ventricular assist device (VAD) being developed by Dante Pazzanese Institute of Cardiology-IDPC (São Paulo, Brazil). The VAD-IDPC has a novel architecture that distinguishes from other known VADs. In this, the rotor has a...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00551.x

    authors: Horikawa O,de Andrade AJ,da Silva I,Bock EG

    更新日期:2008-04-01 00:00:00

  • Can We Develop a Nonpulsatile Permanent Rotary Blood Pump? Yes, We Can.

    abstract::For many years, it was thought that nonpulsatile perfusion produced physiological and circulatory abnormalities. Since 1977, Yukihiko Nosé and his colleagues have challenged this misconception. Toward that end, they did show that if a 20% higher blood flow uses more than that required for a pulsatile blood pump, then ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1996.tb04466.x

    authors: Nosé Y,Kawahito K,Nakazawa T

    更新日期:1996-05-01 00:00:00

  • Is the New Infant Jarvik 2015 Suitable for Patients

    abstract::Our aim was to study the feasibility of implanting the Infant Jarvik 2015 in patients weighing less than 8 kg. The Infant Jarvik 2015 left ventricular assist device (LVAD) was tested in a hybrid simulator of the cardiovascular system reproducing specific patients' hemodynamics for different patient weights (2-7 kg). F...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13302

    authors: Di Molfetta A,Zielinski K,Ferrari G,Kozarski M,Okrzeja P,Iacobelli R,Filippelli S,Perri G,Darowski M,Massetti M,Jarvik R,Amodeo A

    更新日期:2019-01-01 00:00:00

  • Timing of Intra-Aortic Balloon Pump Placement Before Off-Pump Coronary Artery Bypass Grafting and Clinical Outcomes.

    abstract::We aimed to evaluate the timing of preoperative intra-aortic balloon pump (IABP) placement and outcomes in patients undergoing off-pump coronary artery bypass grafting (OPCAB). Patients with prophylactic IABP placement before OPCAB presenting between January 1, 2010 and December 31, 2013 were included. Patients were c...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13009

    authors: Liu F,Yang F,Du Z,Miao N,Zhao Y,Xu B,Hou X

    更新日期:2018-03-01 00:00:00

  • Investigation of the inherent left-right flow balancing of rotary total artificial hearts by means of a resistance box.

    abstract::With the incidence of end-stage heart failure steadily increasing, the need for a practical total artificial heart (TAH) has never been greater. Continuous flow TAHs (CFTAH) are being developed using rotary blood pumps (RBPs), leveraging their small size, mechanical simplicity, and excellent durability. To completely ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13631

    authors: Nestler F,Timms DL,Stevens M,Bradley AP,Wilson SJ,Kleinheyer M,Lovell N,Frazier OH,Cohn WE

    更新日期:2020-06-01 00:00:00

  • Bioengineered cartilage in a scaffold-free method by human cartilage-derived progenitor cells: a comparison with human adipose-derived mesenchymal stromal cells.

    abstract::The objective of our study was to investigate chondrogenesis potential of human adipose-derived mesenchymal stromal cells (MSCs), using as a positive control a human source of cartilage-derived progenitor cells (PCs). This source of PCs was recently described by our group and dwells on the surface of nasoseptal cartil...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12121

    authors: Baptista LS,Silva KR,Pedrosa CS,Amaral RJ,Belizário JV,Borojevic R,Granjeiro JM

    更新日期:2013-12-01 00:00:00

  • Double-blind evaluation of plasmapheresis in schizophrenic patients: a pilot study.

    abstract::Interest in the effects and possible mechanisms of hemodialysis on schizophrenic patients has led to a double-blind evaluation of the effects of plasmapheresis on symptoms of schizophrenia. Also, plasmapheresis was felt to be an invaluable tool for investigating the autoimmune theory of schizophrenia. Patients (n = 10...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1111/j.1525-1594.1983.tb04203.x

    authors: Schulz SC,van Kammen DP,Waters R,Klein HG,Balow JE,Bunney WE Jr

    更新日期:1983-08-01 00:00:00

  • Eccentric roller type total artificial heart creating interatrial shunt.

    abstract::Creating an interatrial shunt to achieve left-right flow balance and modification of the blood chambers to improve the basic performance of the device were performed in developing an eccentric roller type total artificial heart (ERTAH). Smaller blood chambers reduce friction loss and increase durability and energy eff...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06602.x

    authors: Wada H,Fukunaga S,Watari M,Imai K,Sakai H,Shibamura H,Sueda T,Matsuura Y

    更新日期:2000-08-01 00:00:00

  • Is Multiple Overlapping Uncovered Stents Technique Suitable for Aortic Aneurysm Repair?

    abstract::A computational fluid dynamic model to assess the impact of flow-diverter device on intra-aneurysmal flow in complex aortic aneurysm from the viewpoint of hemodynamics is presented. The aim of this study is to investigate the hemodynamic effects of an endovascular flow-diverter technique using multiple overlapping unc...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12993

    authors: Yeow SL,Leo HL

    更新日期:2018-02-01 00:00:00

  • Ex Vivo Porcine Organ Perfusion Models as a Suitable Platform for Translational Transplant Research.

    abstract::In transplantation surgery, extending the criteria for organ donation to include organs that may have otherwise been previously discarded has provided the impetus to improve organ preservation. The traditional method of cold static storage (CS) has been tried and tested and is suitable for organs meeting standard crit...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1111/aor.12865

    authors: Kumar R,Chung WY,Dennison AR,Garcea G

    更新日期:2017-09-01 00:00:00

  • Effect of heparin, platelets, activated platelets, platelet fragments, and hematocrit on activated clotting time.

    abstract::Activated clotting time (ACT) is the most commonly used laboratory test to control the heparin effect during extracorporeal techniques. The study was undertaken in order to test in vitro the influence of heparin, platelet count, hematocrit, platelet fragmentation, and platelet activation on ACT. Blood was drawn from v...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06552.x

    authors: Girardi L,Sudi K,Muntean W

    更新日期:2000-07-01 00:00:00

  • Plasma administration to defibrinogenated dogs during extracorporeal circulation.

    abstract::Plasma, in an amount corresponding to 0.05 gm fibrinogen/Kg of body weight, was administered during one hour to defibrinogenated dogs subjected to extracorporeal circulation. Four blood filters included in the extracorporeal circuit were removed one by one at 30-minute intervals. The prefilter pressures rose gradually...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1979.tb03809.x

    authors: Berglin E,Hansson HA,William-Olsson G