Pathways for water absorption and physiological role of the lateral interspaces in the kidney tubule.

Abstract:

:Possible routes for water and salt flow and the most likely theories that describe coupling between water and salt flow across leaky epithelia are presented. The osmotic theories seem the most likely ones. However, several of the theories have weaknesses that render them unsatisfactory, in particular because of the possibility of paracellular water flow in these epithelia. Puzzling are the findings that measurements of the cellular water osmotic permeability give figures that are too low for some of the exclusively transcellular theories to work. If these observations hold in the future, it may be shown that part of the water moves through paracellular pathways in these leaky epithelia. This view is supported by the observation that large extracellular markers are dragged by volume flow. Finally, experimental evidence is reviewed indicating that changes in the luminal area concentration may modulate the functional state of the nephron junctional complexes.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Whittembury G,Carpi-Medina P,González E,Linares H

doi

10.1111/j.1525-1594.1987.tb02713.x

subject

Has Abstract

pub_date

1987-12-01 00:00:00

pages

478-85

issue

6

eissn

0160-564X

issn

1525-1594

journal_volume

11

pub_type

杂志文章,评审
  • Pseudoendothelium formation in expanded polytetrafluoroethylene grafts implanted in the inferior vena cava of normal and defibrinogenated dogs.

    abstract::The outgrowth of endothelial cells in an expanded polytetrafluoroethylene graft implanted in the canine inferior vena cava was studied by scanning electron microscopy. The adjacent endothelial cells of the vena cava started to invade the anastomotic area three days after the implantation and reached approximately the ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1981.tb04020.x

    authors: Ishimaru S,Berglin E,Hansson HA,Teger-Nilsson AC,William-Olsson G

    更新日期:1981-11-01 00:00:00

  • Beyond the VAD: Human Factors Engineering for Mechanically Assisted Circulation in the 21st Century.

    abstract::Thousands of ventricular assist devices (VADs) currently provide circulatory support to patients worldwide, and dozens of heart pump designs for adults and pediatric patients are under various stages of development in preparation for translation to clinical use. The successful bench-to-bedside development of a VAD inv...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1111/aor.12600

    authors: Throckmorton AL,Patel-Raman SM,Fox CS,Bass EJ

    更新日期:2016-06-01 00:00:00

  • Modeling of a rotary blood pump.

    abstract::The accurate representation of rotary blood pumps in a numerical environment is important for meaningful investigation of pump-cardiovascular system interactions. Although numerous models for ventricular assist devices (VADs) have been developed, modeling methods for rotary total artificial hearts (rTAHs) are still re...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12142

    authors: Nestler F,Bradley AP,Wilson SJ,Timms DL

    更新日期:2014-03-01 00:00:00

  • Flow visualization study on centrifugal blood pump using a high speed video camera.

    abstract::Flow visualization is widely applied to evaluate rotary blood pumps; however, it is very difficult to visualize flow near the vanes of centrifugal blood pumps because the rotational speed of the impeller is usually several thousand rpm. In this study, a tracer method with a high speed video camera that can take more t...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1995.tb02399.x

    authors: Sakuma I,Tadokoro H,Fukui Y,Dohi T

    更新日期:1995-07-01 00:00:00

  • Centrifugal pumps and heparin-coated circuits in surgical treatment of giant cerebral aneurysms.

    abstract::Giant cerebral aneurysms may be untreatable by conventional neurosurgical techniques. Early attempts to use circulatory assistance and deep hypothermia were abandoned due to hemorrhagic complications. More recently, interest in circulatory support for complex neurosurgical procedures has been renewed. A consecutive se...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06594.x

    authors: Mesana T,Collart F,Caus T,Pomane C,Graziani N,Bruder N,Dufour H,Grisoli F,Montiès JR

    更新日期:2000-06-01 00:00:00

  • Prediction of mechanical hemolysis in medical devices via a Lagrangian strain-based multiscale model.

    abstract::This work introduces a new Lagrangian strain-based model to predict the shear-induced hemolysis in biomedical devices. Current computational models for device-induced hemolysis usually utilize empirical fitting of the released free hemoglobin (Hb) in plasma from damaged red blood cells (RBCs). These empirical correlat...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13663

    authors: Nikfar M,Razizadeh M,Zhang J,Paul R,Wu ZJ,Liu Y

    更新日期:2020-08-01 00:00:00

  • Clinical Use of Centrifugal Pumps and the Roller Pump in Open Heart Surgery: A Comparative Evaluation.

    abstract::Centrifugal pumps have been used widely as the main pump in open heart surgery to reduce damage to blood elements and to reduce the activation of the coagulation system. The purpose of this study was the evaluation and comparison of the effects of two types of centrifugal pumps and of one type of roller pump on blood ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1996.tb04507.x

    authors: Yoshikai M,Hamada M,Takarabe K,Okazaki Y,Yoshika M

    更新日期:1996-05-01 00:00:00

  • Development and characterization of a new stationary phase for an immunoadsorption wall.

    abstract::This study introduces a newly developed method for the formation of a stationary phase superficially embedded with immunoadsorbent, that is partially incomplete two-stage polymerization of acrylamide. Preliminary experimental studies show that binding activity of the immunoadsorbent was satisfactorily maintained after...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2005.29071.x

    authors: Yang TH

    更新日期:2005-05-01 00:00:00

  • Assessment of skeletal muscle ventricle tissue blood flow using positron emission tomography.

    abstract::In this pilot study, we assessed the feasibility of using positron emission tomography (PET) imaging for in vivo measurement of skeletal muscle ventricle (SMV) tissue blood flow. In 4 dogs, with SMVs prepared from their latissimus dorsi muscle, we quantified SMV tissue blood flow by PET and related it to the tissue fl...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors: Singh TP,Greer K,Muzik O,Hammond RL,Stephenson LW,Di Carli MF

    更新日期:2001-04-01 00:00:00

  • Role of the BioMedicus pump and distal aortic perfusion in thoracoabdominal aortic aneurysm repair.

    abstract::We reviewed the role of the BioMedicus pump in the reduction of neurologic complications following the repair of Type 1 and Type 2 thoracoabdominal aortic aneurysms. Since 1991, we have used several different methods for the repair of thoracoabdominal aortic aneurysms including simple cross-clamping, selective use of ...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:

    authors: Safi HJ

    更新日期:1996-06-01 00:00:00

  • Adsorption of microorganism components by lixelle beads.

    abstract::We reported previously that Lixelle, which was used for beta-2 microglobulin (BMG) adsorption columns, could adsorb not only BMG but also inflammatory cytokines. We then were interested in the application of Lixelle to patients with systemic inflammatory response syndrome (SIRS) and tried to find out its ability to ad...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06502-2.x

    authors: Tsuchida K,Takemoto Y,Nakatani T,Nakamura T,Sugimura K,Yamamoto K

    更新日期:2000-07-01 00:00:00

  • Double-blind evaluation of plasmapheresis in schizophrenic patients: a pilot study.

    abstract::Interest in the effects and possible mechanisms of hemodialysis on schizophrenic patients has led to a double-blind evaluation of the effects of plasmapheresis on symptoms of schizophrenia. Also, plasmapheresis was felt to be an invaluable tool for investigating the autoimmune theory of schizophrenia. Patients (n = 10...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1111/j.1525-1594.1983.tb04203.x

    authors: Schulz SC,van Kammen DP,Waters R,Klein HG,Balow JE,Bunney WE Jr

    更新日期:1983-08-01 00:00:00

  • Are the Current Doppler Echocardiography Criteria Able to Discriminate Mitral Bileaflet Mechanical Heart Valve Malfunction? An In Vitro Study.

    abstract::Malfunction of bileaflet mechanical heart valves in the mitral position could either be due to patient-prosthesis mismatch (PPM) or leaflet obstruction. The aim of this article is to investigate the validity of current echocardiographic criteria used for diagnosis of mitral prosthesis malfunction, namely maximum veloc...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12653

    authors: Evin M,Guivier-Curien C,Pibarot P,Kadem L,Rieu R

    更新日期:2016-05-01 00:00:00

  • Changes in Spirometry After Left Ventricular Assist Device Implantation.

    abstract::Left ventricular assist devices (LVADs) are increasingly being used as life-saving therapy in patients with end-stage heart failure. The changes in spirometry following LVAD implantation and subsequent unloading of the left ventricle and pulmonary circulation are unknown. In this study, we explored long-term changes i...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12507

    authors: Mohamedali B,Bhat G,Yost G,Tatooles A

    更新日期:2015-12-01 00:00:00

  • The role of diastolic pump flow in centrifugal blood pump hemodynamics.

    abstract::We tried to verify the hypothesis that increases in pump flow during diastole are matched by decreases in left ventricular (LV) output during systole. A calf (80 kg) was implanted with an implantable centrifugal blood pump (EVAHEART, SunMedical Technology Research Corp., Nagano, Japan) with left ventricle to aorta (LV...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2001.06864.x

    authors: Akimoto T,Litwak KN,Yamazaki K,Litwak P,Kihara SI,Tagusari O,Yamazaki SI,Kameneva MV,Watach MJ,Umezu M,Tomioka J,Kormos RL,Koyanagi H,Griffith BP

    更新日期:2001-09-01 00:00:00

  • Evaluation of membrane oxygenators and reservoirs in terms of capturing gaseous microemboli and pressure drops.

    abstract::An increasing amount of evidence points to cerebral embolization during cardiopulmonary bypass (CPB) as the principal etiologic factor of neurologic complications. In this study, the capability of capturing and classification of gaseous emboli and pressure drop of three different membrane oxygenators (Sorin Apex, Teru...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00955.x

    authors: Guan Y,Palanzo D,Kunselman A,Undar A

    更新日期:2009-11-01 00:00:00

  • Initial experience with Impella RP in a quaternary transplant center.

    abstract::Right ventricular failure is one of the most common complications encountered after left ventricular assist device implantation and heart transplantation. It has been reported to have an incidence up to 30%. It increases morbidity and short-term mortality. Impella RP is a small pump that can provide up to 4L/min of fl...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13610

    authors: Monteagudo-Vela M,Simon A,Panoulas V

    更新日期:2020-05-01 00:00:00

  • The monomeric formulation optimization of dental composite: mechanical and kinetic studies.

    abstract::The optimization of the monomer composition, using a polymerization kinetic study and the mechanical behavior study of the composites, was the principal objective of this work. The monomeric mixture analyzed is a part of the composite that has been in development at the University of Campinas, Brazil. Parameters such ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2003.07250.x

    authors: López Palacio RE,de Carvalho Zavaglia CA

    更新日期:2003-05-01 00:00:00

  • Estimation of maximum ventricular elastance under assistance with a rotary blood pump.

    abstract::The maximum ventricular elastance is a reliable index for assessing the cardiac function from changes in its pressure-volume relationship. The advantage of this index is that it can represent the contractility of either unassisted hearts or native hearts assisted with rotary blood pumps. However, there are situations ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00876.x

    authors: Sugai TK,Tanaka A,Yoshizawa M,Shiraishi Y,Yambe T,Nitta S,Baba A

    更新日期:2010-05-01 00:00:00

  • Relation between echinocytosis and erythrocyte calcium content in hemodialyzed uremic patients.

    abstract::A rise in intracellular calcium concentration in erythrocytes has multiple effects on these cells. The purpose of this study was to determine the changes of calcium content in red blood cells (RBCs) and of echinocyte percentages in uremic patients during hemodialysis sessions. In 30 uremic patients under hemodialysis,...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2001.025006486.x

    authors: Agroyannis B,Kopelias I,Fourtounas C,Paraskevopoulos A,Tzanatos H,Dalamangas A,Mallas E

    更新日期:2001-06-01 00:00:00

  • Gaseous micro-emboli activity during cardiopulmonary bypass in adults: pulsatile flow versus nonpulsatile flow.

    abstract::Cardiopulmonary bypass (CPB) has a risk of cerebral injury, with an important role of gaseous micro-emboli (GME) coming from the CPB circuit. Pulsatile perfusion is supposed to perform specific conditions for supplementary GME activity. We aimed to determine whether pulsatile CPB augments production and delivery of GM...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12000

    authors: Dodonov M,Milano A,Onorati F,Dal Corso B,Menon T,Ferrarini D,Tessari M,Faggian G,Mazzucco A

    更新日期:2013-04-01 00:00:00

  • Anionic collagen: polymer composites with improved dielectric and rheological properties.

    abstract::This work describes the preparation and characterization of anionic collagen composites with rhamsan and vinylidene fluoride-trifluorethylene with improved rheological and dielectric properties without loss of collagen secondary structure with an interaction occurring between both macromolecules of the composites. On ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.06109.x

    authors: Goissis G,Piccirili L,Goes JC,de Guzzi Plepis AM,Das-Gupta DK

    更新日期:1998-03-01 00:00:00

  • Multimodal flow visualization and optimization of pneumatic blood pump for sorbent hemodialysis system.

    abstract::Renal Solutions Allient Sorbent Hemodialysis System utilizes a two-chambered pneumatic pump (Pulsar Blood Pump, Renal Solutions, Inc., Warrendale, PA, USA) to avoid limitations associated with peristaltic pumping systems. Single-needle access is enabled by counter-pulsing the two pump chambers, thereby obviating compl...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00724.x

    authors: Shu F,Parks R,Maholtz J,Ash S,Antaki JF

    更新日期:2009-04-01 00:00:00

  • Myristoyl gelatin as a sealant for Dacron vascular prostheses.

    abstract::Myristoyl gelatin (MG) retains its gel structure at temperatures above body temperature without any crosslinking. As a coating material, MG adheres well to polyester fibers, and the outermost layers of the sealant that are in contact with blood or surrounding tissue become hydrophilic. We produced MG-impregnated knitt...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb00363.x

    authors: Sasajima T,Inaba M,Azuma N,Goh K,Koshiko S,Kubo Y,Miyamoto K,Tokita M,Komai T

    更新日期:1997-04-01 00:00:00

  • A novel technique to produce tubular scaffolds based on collagen and elastin.

    abstract::Tubular polymer scaffolds based on tissue engineering techniques have been studied as potential alternatives for vascular regeneration implants. The blood vessels of the cardiovascular system are mainly fibrous, composed of collagen (Col) and elastin (El), and its inner layer consists of endothelial cells. In this wor...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13857

    authors: Rodrigues ICP,Pereira KD,Woigt LF,Jardini AL,Luchessi AD,Lopes ÉSN,Webster TJ,Gabriel LP

    更新日期:2020-11-10 00:00:00

  • Double catheterization of the internal jugular vein for hemodialysis: indications, techniques, and clinical results.

    abstract::Central vascular catheters are used to access the central vascular system in both acute and chronic uremic patients undergoing hemodialysis. Among different approaches, the internal jugular vein seems to have less adverse effects. We describe our long-term experience with a two-catheter system. Percutaneous jugular ve...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1994.tb02200.x

    authors: Tesio F,De Baz H,Panarello G,Calianno G,Quaia P,Raimondi A,Schinella D

    更新日期:1994-04-01 00:00:00

  • Myocardial protection in pediatric cardiac surgery.

    abstract::The combination of hypothermia and potassium cardioplegic arrest has become the most common method of myocardial protection in the evolution of myocardial protection. This review focuses on myocardial protection in pediatric cardiac surgery. In the 1980s, blood was added to cardioplegia solution in order to supply the...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1111/aor.12029

    authors: Turkoz R

    更新日期:2013-01-01 00:00:00

  • Isoelastic polyurethane prosthesis for segmental trachea replacement in beagle dogs.

    abstract::Porous polyurethane (nonwoven) was used for the development of tracheal prosthesis, which--in a special testing design--was adapted to shape and biomechanic properties of the natural organ. This prosthesis was implanted into 19 beagle dogs using inverted, everted, and end-to-end anastomosis. Insufficiency of the anast...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1989.tb02866.x

    authors: Schauwecker HH,Gerlach J,Planck H,Bücherl ES

    更新日期:1989-06-01 00:00:00

  • The DeBakey ventricular assist device: current status in 1997.

    abstract::In 1993, the development began of a small axial flow blood pump, the DeBakey ventricular assist device (VAD). The material was recently converted to a titanium alloy, and a waterproof pump package was incorporated for long-term intracorporeal circulation. Thirteen intrathoracic implantations in calves were achieved. N...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1046/j.1525-1594.1999.06300.x

    authors: Tayama E,Olsen DB,Ohashi Y,Benkowski R,Morley D,Noon GP,Nosé Y,Debakey ME

    更新日期:1999-12-01 00:00:00

  • Aging adversely impacts biological properties of human bone marrow-derived mesenchymal stem cells: implications for tissue engineering heart valve construction.

    abstract::Our aim was to study the aging effects on the in vitro biological properties of bone marrow-derived mesenchymal stem cells (BMSCs) for construction of tissue-engineered heart valves. BMSCs were taken from teenagers with congenital heart diseases, and middle-aged and elderly patients with valvular diseases. Proliferati...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00824.x

    authors: Xin Y,Wang YM,Zhang H,Li J,Wang W,Wei YJ,Hu SS

    更新日期:2010-03-01 00:00:00