Abstract:
:This study introduces a newly developed method for the formation of a stationary phase superficially embedded with immunoadsorbent, that is partially incomplete two-stage polymerization of acrylamide. Preliminary experimental studies show that binding activity of the immunoadsorbent was satisfactorily maintained after immobilization. With an appropriate configuration of selected immunoadsorption matrices and immunoisolation barriers, it is hoped that this stationary phase could be used to resolve some difficult problems arising from the accumulation of certain middle molecular weight toxins not removed by other blood purification procedures.
journal_name
Artif Organsjournal_title
Artificial organsauthors
Yang THdoi
10.1111/j.1525-1594.2005.29071.xsubject
Has Abstractpub_date
2005-05-01 00:00:00pages
422-6issue
5eissn
0160-564Xissn
1525-1594pii
AOR29071journal_volume
29pub_type
杂志文章abstract::There are presently no short-term in vitro fatigue tests available that can predict long-term in vivo performance of elastomers in physiological environments. Thus, the introduction of new and better elastomers for cardiovascular applications is hampered in the development stage by lack of data about which materials s...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1983.tb04162.x
更新日期:1983-02-01 00:00:00
abstract::Tissue responses to various percutaneous materials with different surface properties and structures were investigated. Dense hydroxyapatite (HA), tricalcium phosphate (TCP), glassy carbon (GC), and 2 types of porous HA were used. Cutaneous and subcutaneous tissues were tightly attached to the surface of the penetratin...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1997.tb00514.x
更新日期:1997-09-01 00:00:00
abstract::The rotational axis of the centrifugal pump has some associated problems such as blood destruction and sealing between the axis and pump housing. To improve upon these deficits we have developed a new type of blood pump, the magnetic rotary pump (MRP). The MRP has an original design with no rotational axis and no impe...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1997.tb03734.x
更新日期:1997-07-01 00:00:00
abstract::Hypertension is an important primary etiology of end-stage renal disease as well as a major factor responsible for progression of renal disease due to other causes. Multiple genetic and environmental factors are responsible for the variable prevalence of hypertension in various parts of the world. Although the frequen...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.2002.07067.x
更新日期:2002-09-01 00:00:00
abstract::Thirty-five patients undergoing open-heart surgery are reported. Cardiac index, mean arterial pressure, oxygen consumption, lactate, pyruvate, and lactate excess in the blood were measured. An inverse correlation of arterial pressure with oxygen consumption and lactate excess was found during perfusion. Comparison of ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1982.tb01675.x
更新日期:1982-08-01 00:00:00
abstract::We assessed the relationship of certain clinical variables (including bradykinin [BK] release and dialysis membrane) to initial mean arterial pressure (MAP) reduction in 47 patients requiring continuous renal replacement therapy (CRRT) in an intensive care unit. The pretreatment MAP was 84 +/- 14 mm Hg for the group a...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.2001.06703.x
更新日期:2001-12-01 00:00:00
abstract::The aim of this study was to prepare a DNA immunoadsorbent for the specific, extracorporeal removal of anti-DNA antibodies from the blood of patients with systemic lupus erythematosus (SLE) and rheumatoid arthritis (RA). Two kinds of cellulose beads were applied as a carrier. Calf thymus DNA was covalently coupled to ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.2002.06721.x
更新日期:2002-02-01 00:00:00
abstract::Polyvinyl chloride (PVC) is one of the most frequently used polymers for the manufacturing of medical devices. Limitations for its usage are based upon unfavorable surface properties of the polymer including its hydrophobicity and lack of functionalities in order to increase its versatility. To address this issue, wet...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2012.01462.x
更新日期:2012-09-01 00:00:00
abstract::This article presents results from the field calculation in a model of biological tissue taking into account the electroporation process. The electroporation model used in this study was proposed and experimentally verified by Glaser et al. for planar membranes. The numerical method for field calculation is based on a...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2005.29085.x
更新日期:2005-06-01 00:00:00
abstract::Individualized short hemodialysis treatment schedules, approximately three 3-h treatments per week, were introduced in a nephrology unit in 1976. In May 1985, 259 patients had been treated, which corresponds to approximately 60 new patients per million inhabitants per year. Ages at start of therapy ranged between 17 a...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1986.tb02541.x
更新日期:1986-06-01 00:00:00
abstract::To provide percutaneous access, a new circulatory assist system was developed. We call this newly developed system the modified assist device (MAD). The system is composed of a sac-type blood pump and cannula. Inflow and outflow valves are mounted in the apex and at the side wall 10 cm from the apex of the cannula, re...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1996.tb00718.x
更新日期:1996-02-01 00:00:00
abstract::This article presents an image processing approach dedicated for a blind mobility aid facilitated through visual intracortical electrical stimulation. The method examines a display framework based on the distances related to a scene. The distances of objects to the walker are measured using a size perspective method w...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2011.01421.x
更新日期:2012-07-01 00:00:00
abstract::Albumin-coated Amberlite XAD-7 has been previously shown to be blood compatible in in vitro hemoperfusion experiments whith human blood. In this study, the preliminary results are reported on single hemoperfusions with albumin-coated XAD-7 resin in four patients with acute liver failure. The mean platelet count was 11...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1979.tb03800.x
更新日期:1979-02-01 00:00:00
abstract::By using high speed gel filtration combined with ion exchange gradient elution chromatography, the concentrations of plasma (p) middle molecules (MM) were determined in 126 samples from 90 non-dialyzed azotemic patients and in 210 pre-dialysis samples from 53 regular hemodialysis and 24 intermittent peritoneal dialysi...
journal_title:Artificial organs
pub_type: 杂志文章
doi:
更新日期:1981-01-01 00:00:00
abstract::It is well known that the baroreflex system is one of the most important indicators of the pathophysiology in hypertensive patients. We can check the sensitivity of the baroreflex by observing heart rate (HR) responses; however, there is no simple diagnostic method to measure the arterial behavior in the baroreflex sy...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2009.00864.x
更新日期:2009-09-01 00:00:00
abstract::The growing practice of dialyzer reuse in recent years is mainly based on medical and economic considerations. However, adverse reactions such as immunohemolytic anemia due to anti-Nform antibody associated with dialyzer reuse have been reported. In this study, scanning electron microscopy and cytologic staining were ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1996.tb04418.x
更新日期:1996-01-01 00:00:00
abstract::Few instruments are currently available to test mitral valve function in an ex vivo state due to the technical difficulties involved. To investigate the native ex vivo mitral valve or prosthetic mitral valve with chordae, we developed a mitral valve adapter with an annulus suturing portion and 2 papillary muscle sutur...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.1999.06293.x
更新日期:1999-10-01 00:00:00
abstract::Modeling different treatment options before a procedure is performed is a promising approach for surgical decision making and patient care in heart valve disease. This study investigated the hemodynamic impact of different prostheses through patient-specific MRI-based CFD simulations. Ten time-resolved MRI data sets w...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.12955
更新日期:2018-01-01 00:00:00
abstract::Although current continuous-flow total artificial hearts (CFTAHs) are much smaller than previous models, venous kinking may still occur after device implantation, especially in smaller animals. By inserting a self-expanding stent at the site of venous narrowing in a sheep model implanted with a CFTAH, we were able to ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2011.01233.x
更新日期:2011-07-01 00:00:00
abstract::The use of and demand for functional electrical stimulation (FES) systems and conventional orthoses in the spinal cord lesioned population was assessed. The assessment was conducted by a postal survey of the members of the spinal injury associations in the U.K. Out of all the respondents, only 2% had used an FES syste...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.1999.06361.x
更新日期:1999-05-01 00:00:00
abstract::Biomechanical actuation of an implanted ventricular assist device (VAD) is an attractive means of providing long-term circulatory support. Studies show that energy from electrically stimulated skeletal muscle can, in principle, be used to provide tether-free cardiac assistance without the need for percutaneous driveli...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2010.01170.x
更新日期:2011-07-01 00:00:00
abstract::The effect of blood hematocrit (HCT) on a noninvasive flow estimation algorithm was examined in a centrifugal implantable rotary blood pump (iRBP) used for ventricular assistance. An average flow estimator, based on three parameters, input electrical power, pump speed, and HCT, was developed. Data were collected in a ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2007.00339.x
更新日期:2007-01-01 00:00:00
abstract::The combination of hypothermia and potassium cardioplegic arrest has become the most common method of myocardial protection in the evolution of myocardial protection. This review focuses on myocardial protection in pediatric cardiac surgery. In the 1980s, blood was added to cardioplegia solution in order to supply the...
journal_title:Artificial organs
pub_type: 杂志文章,评审
doi:10.1111/aor.12029
更新日期:2013-01-01 00:00:00
abstract::We have been developing a new type of centrifugal pump for long-term use. The magnetically suspended centrifugal pump (MSCP) contains no shaft and seal so that long life expectancy is predicted. Paracorporeal left ventricular (LV) assist circulation between the left atrium and the descending aorta was instituted using...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1997.tb03713.x
更新日期:1997-07-01 00:00:00
abstract::The present study aimed to determine the feasibility of constructing a reinforced autologous vascular graft by combining the advantages of fibrin gel as an autologous cell carrier material with the inherent mechanical strength of an integrated mesh structure. It was hypothesized that the mesh and dynamic culture condi...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2008.00601.x
更新日期:2008-10-01 00:00:00
abstract::We treated 12 patients with rheumatoid arthritis by filtration leukocytapheresis (FLCP) and evaluated its effect on leukocyte enzyme activities. We calculated the number of leukocytes removed and assessed the clinical response. We also evaluated the cellular enzyme activities of elastase and dipeptidylpeptidase IV (DP...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.2002.06834.x
更新日期:2002-04-01 00:00:00
abstract::To assess the efficiency of respiratory gas exchange in vitro through a dialysis membrane mounted inside a flat plate Kiil dialyzer, the model reactions of hydrogen peroxide reduction by a metal ion and of the carbon dioxide precipitation in the form of a carbonate in the dialysate were used. A comparison of the rates...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1983.tb04189.x
更新日期:1983-05-01 00:00:00
abstract::The aim of this meta-analysis was to determine whether pulsatile perfusion during cardiac surgery has a lesser effect on renal dysfunction than nonpulsatile perfusion after cardiac surgery in randomized controlled trials. MEDLINE, EMBASE, and the Cochrane Central Register of Controlled Trials were used to identify ava...
journal_title:Artificial organs
pub_type: 杂志文章,meta分析
doi:10.1111/aor.12452
更新日期:2015-09-01 00:00:00
abstract::Twelve patients, 8 male and 4 female, aged from 26 to 70 years were studied. They were on hemodialysis (HD) 4 h three times weekly with cuprophan hollow fiber dialyzers (Gambro 120M) and dialysate containing 35 mEq/L of acetate. The study compares two random HD sessions on each patient. Sixty minutes prior to one rand...
journal_title:Artificial organs
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1111/j.1525-1594.1989.tb01551.x
更新日期:1989-10-01 00:00:00
abstract::We carried out this retrospective study to examine the magnesium status of our chronic ambulatory peritoneal dialysis (CAPD) patients dialyzed with 0.75 mmol/L (group I) or 0.50 mmol/L (group II) magnesium peritoneal dialysis solution. A total of 34 anuric patients on CAPD (age:31-72 years; duration of CAPD:7-74 month...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.2003.07193.x
更新日期:2003-09-01 00:00:00