Stent treatment of inferior vena cava compression in an ovine with a total artificial heart.

Abstract:

:Although current continuous-flow total artificial hearts (CFTAHs) are much smaller than previous models, venous kinking may still occur after device implantation, especially in smaller animals. By inserting a self-expanding stent at the site of venous narrowing in a sheep model implanted with a CFTAH, we were able to restore the normal venous geometry and dramatically increase the CFTAH output. Because this percutaneous approach avoids the challenges associated with reoperation in these cases, it may be useful to other CFTAH investigators.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Tuzun E,Parnis S,Rios J,Winkler JA,Cohn WE

doi

10.1111/j.1525-1594.2011.01233.x

subject

Has Abstract

pub_date

2011-07-01 00:00:00

pages

E161-3

issue

7

eissn

0160-564X

issn

1525-1594

journal_volume

35

pub_type

杂志文章
  • Uremic neuropathy: evidence of middle molecule toxicity.

    abstract::Ten dialysis patients were followed in a prospective study to determine the neurotoxicity of metabolites in the middle molecule (MM) molecular weight (mol wt) range of 500-200 daltons/molecule. In the absence of readily available direct serum measurements of MM concentrations, a theoretically calculated dialysis index...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1978.tb01002.x

    authors: Milutinovic J,Babb AL,Eschbach JW,Follette WC,Graefe U,Strand MJ,Scribner BH

    更新日期:1978-02-01 00:00:00

  • Is serum albumin a marker of nutritional status in hemodialysis patients without evidence of inflammation?

    abstract::Hypoalbuminemia, a strong predictor of morbidity and mortality in hemodialysis patients, can be a consequence of a combination of malnutrition and inflammatory reactions. The purpose of this study was to analyze serum albumin as a marker of nutritional status in maintenance hemodialysis patients with no signs of infla...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2003.07273.x

    authors: Santos NS,Draibe SA,Kamimura MA,Canziani ME,Cendoroglo M,Júnior AG,Cuppari L

    更新日期:2003-08-01 00:00:00

  • The DeBakey ventricular assist device: current status in 1997.

    abstract::In 1993, the development began of a small axial flow blood pump, the DeBakey ventricular assist device (VAD). The material was recently converted to a titanium alloy, and a waterproof pump package was incorporated for long-term intracorporeal circulation. Thirteen intrathoracic implantations in calves were achieved. N...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1046/j.1525-1594.1999.06300.x

    authors: Tayama E,Olsen DB,Ohashi Y,Benkowski R,Morley D,Noon GP,Nosé Y,Debakey ME

    更新日期:1999-12-01 00:00:00

  • The pivot wash in two impeller modes for the Baylor/Miwatec centrifugal blood pump.

    abstract::A centrifugal blood pump with a double pivot impeller and an eccentric inlet port is being developed as an implantable artificial heart by the Baylor College of Medicine and Miwatec Co. Ltd. Flow visualization measurements were conducted to compare the flow around the pivot for two impeller operational modes: the top ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2006.00155.x

    authors: Yamane T,Kodama T,Nishida M,Maruyama O,Yamamoto Y,Shinohara T,Motomura T,Nosé Y

    更新日期:2006-01-01 00:00:00

  • Acellular Endocardium as a Novel Biomaterial for the Intima of Tissue-Engineered Small-Caliber Vascular Grafts.

    abstract::We aimed to investigate whether acellular endocardium can be used as a useful biomaterial for the intima of engineered small-caliber vascular grafts. Fresh endocardium was harvested from the swine left atrium and was decellularized by digestion with the decellularization solution of Triton X-100 and SDS containing DNa...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12814

    authors: Wang F,Guan X,Wu T,Qiao J,Han Z,Wu J,Yu X,You Q

    更新日期:2016-12-01 00:00:00

  • Myocardial protection in pediatric cardiac surgery.

    abstract::The combination of hypothermia and potassium cardioplegic arrest has become the most common method of myocardial protection in the evolution of myocardial protection. This review focuses on myocardial protection in pediatric cardiac surgery. In the 1980s, blood was added to cardioplegia solution in order to supply the...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1111/aor.12029

    authors: Turkoz R

    更新日期:2013-01-01 00:00:00

  • Are the Current Doppler Echocardiography Criteria Able to Discriminate Mitral Bileaflet Mechanical Heart Valve Malfunction? An In Vitro Study.

    abstract::Malfunction of bileaflet mechanical heart valves in the mitral position could either be due to patient-prosthesis mismatch (PPM) or leaflet obstruction. The aim of this article is to investigate the validity of current echocardiographic criteria used for diagnosis of mitral prosthesis malfunction, namely maximum veloc...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12653

    authors: Evin M,Guivier-Curien C,Pibarot P,Kadem L,Rieu R

    更新日期:2016-05-01 00:00:00

  • A percutaneously accessible pulsatile left ventricular assist device: modified assist device type 5.

    abstract::To provide percutaneous access, a new circulatory assist system was developed. We call this newly developed system the modified assist device (MAD). The system is composed of a sac-type blood pump and cannula. Inflow and outflow valves are mounted in the apex and at the side wall 10 cm from the apex of the cannula, re...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1996.tb00718.x

    authors: Imanishi K,Imachi K,Yoshito H,Isoyama T,Abe Y,Chinzei T,Mabuchi K,Kanda K,Tsutsui N,Suma K,Fujimasa I

    更新日期:1996-02-01 00:00:00

  • The role of PI3K/Akt signaling pathway in non-physiological shear stress-induced platelet activation.

    abstract::The PI3K/Akt signaling pathway has been implicated in playing an important role in platelet activation during hemostasis and thrombosis involving platelet-matrix interaction and platelet aggregation. Its role in non-physiological shear stress (NPSS)-induced platelet activation relevant to high-shear blood contacting m...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13465

    authors: Chen Z,Li T,Kareem K,Tran D,Griffith BP,Wu ZJ

    更新日期:2019-09-01 00:00:00

  • HeartWare Ventricular Assist Device Implantation for Pediatric Heart Failure-A Single Center Approach.

    abstract::While pediatric HeartWare HVAD application has increased, determining candidacy and timing for initiation of pediatric VAD support has remained a challenge. We present our experience with a systematic approach to HVAD implantation as a bridge to pediatric heart transplantation. We performed a retrospective, single cen...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13344

    authors: Nelson McMillan K,Hibino N,Brown EE,Wadia R,Hunt EA,Marshall C,Alvarez-Machado M,Alejo D,Coulson JD,Ravekes W,Vricella LA

    更新日期:2019-01-01 00:00:00

  • Multimodal flow visualization and optimization of pneumatic blood pump for sorbent hemodialysis system.

    abstract::Renal Solutions Allient Sorbent Hemodialysis System utilizes a two-chambered pneumatic pump (Pulsar Blood Pump, Renal Solutions, Inc., Warrendale, PA, USA) to avoid limitations associated with peristaltic pumping systems. Single-needle access is enabled by counter-pulsing the two pump chambers, thereby obviating compl...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00724.x

    authors: Shu F,Parks R,Maholtz J,Ash S,Antaki JF

    更新日期:2009-04-01 00:00:00

  • Selective Cerebro-Myocardial Perfusion in Complex Neonatal Aortic Arch Pathology: Midterm Results.

    abstract::Aortic arch repair in newborns and infants has traditionally been accomplished using a period of deep hypothermic circulatory arrest. To reduce neurologic and cardiac dysfunction related to circulatory arrest and myocardial ischemia during complex aortic arch surgery, an alternative and novel strategy for cerebro-myoc...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13128

    authors: Hoxha S,Abbasciano RG,Sandrini C,Rossetti L,Menon T,Barozzi L,Linardi D,Rungatscher A,Faggian G,Luciani GB

    更新日期:2018-04-01 00:00:00

  • Design of a symmetry controller for cycling induced by electrical stimulation: preliminary results on post-acute stroke patients.

    abstract::This study deals with the design of a controller for cycling induced by functional electrical stimulation. The controller will be exploitable in the rehabilitation of hemiparetic patients who need to recover motor symmetry. It uses the pulse width as the control variable in the stimulation of the two legs in order to ...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1525-1594.2009.00941.x

    authors: Ambrosini E,Ferrante S,Schauer T,Ferrigno G,Molteni F,Pedrocchi A

    更新日期:2010-08-01 00:00:00

  • Measurement of the closing behavior of the björk-shiley monoleaflet mechanical heart valve with an electrohydraulic total artificial heart.

    abstract::When cavitation occurs near a material surface of a mechanical heart valve (MHV), pits on the surface of the MHV and hemolysis are caused. Therefore, it is very important to investigate the possibility of the occurrence of cavitation in an MHV. To study the possibility of cavitation occurrence in a 25 mm Björk-Shiley ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2003.06981.x

    authors: Lee H,Tsukiya T,Homma A,Taenaka Y,Tatsumi E,Takano H

    更新日期:2003-08-01 00:00:00

  • Methodology for identification of serum middle molecules.

    abstract::Filtration through membranes with different nominal cut-off was used for isolation of middle molecule fractions from uremic serum. Comparison was made with test substances which in gel filtration did not show a regular relationship between molecular weight and partition coefficient. The XM50 membrane (cut-off 50,000 D...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors: Buzio C,Montagna G,Calderini C,Manari A,Migone L

    更新日期:1981-01-01 00:00:00

  • Experiencing Functional Electrical Stimulation Roots on Education, and Clinical Developments in Paraplegia and Tetraplegia With Technological Innovation.

    abstract::Cybernetics-based concepts can allow for complete independence for paralyzed individuals, including sensory motor recovery. Spinal cord injuries are responsible for a huge stress on health and a financial burden to society. This article focuses on novel procedures such as functional diagnosis for paraplegics and tetra...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1111/aor.12620

    authors: Varoto R,Cliquet A Jr

    更新日期:2015-10-01 00:00:00

  • Influence of antihypertensive drugs and steroid hormones on protein adsorption/desorption on polycarbonate.

    abstract::To develop artificial materials for prolonged use in the vascular system, the complicated process of surface-induced thrombosis needs to be better understood. It is documented that certain antihypertensive drugs can inhibit platelet adhesion to an artificial surface; on the other hand, steroid drugs increase platelet ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors: Chandy T,Sharma CP

    更新日期:1991-06-01 00:00:00

  • Intestinal tissue oxygenation and tumor necrosis factor-alpha release during systemic blood flow changes in pigs with left ventricular assist devices.

    abstract::We previously demonstrated that tumor necrosis factor-alpha (TNF-alpha) increased following a reduction in systemic blood flow to 60% or less of the original cardiac output using a left ventricular assist device (LVAD). The aim of this study was to investigate the effect of reducing systemic blood flow on tissue oxyge...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2001.025001053.x

    authors: Uozaki Y,Dihmis WC,Yamauchi H,Moczar M,Miyama M,Pasteau F,Tixier D,Bambang SL,Loisance DY

    更新日期:2001-01-01 00:00:00

  • The effects of homologous cross-circulation and in situ liver perfusion on fulminant hepatic failure rats.

    abstract::A galactosamine-induced fulminant hepatic failure (FHF) rat model was used to study the effects of homologous cross-circulation and in situ liver perfusion. Cross-circulation with homologous donors did not significantly improve the survival time or recovery rate of grade II hepatic coma rats. Homologous in situ liver ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1980.tb03929.x

    authors: Mohsini K,Lister C,Chang TM

    更新日期:1980-08-01 00:00:00

  • Coronary artery bypass grafting for dialysis patients: usefulness of multiarterial bypass.

    abstract::This study assessed the efficacy of multiarterial bypass in coronary artery bypass grafting (CABG) in dialysis patients. Eighty dialysis patients who underwent CABG were divided into 2 groups. Group A consisted of 38 patients in whom the left internal thoracic artery and additional saphenous vein graft (SVG) had been ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors: Nakayama Y,Sakata R,Ura M

    更新日期:2001-04-01 00:00:00

  • Use of an integrated sideport for diagnosis and management of decreased flow rates in a programmable implanted insulin delivery system. Implantable Insulin Pump Trial Study Group.

    abstract::The aim of this study was to develop procedures for the diagnosis and nonsurgical management of decreased insulin flow in an implantable programmable pump for long-term intraperitoneal or intravenous insulin delivery featuring a sideport. Patency of the catheter lumen was tested by measuring the time needed for sidepo...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1525-1594.1996.tb04586.x

    authors: Scavini M,Reich S,Eaton RP,Charles MA,Dunn FL

    更新日期:1996-09-01 00:00:00

  • Bone marrow combined with dental bud cells promotes tooth regeneration in miniature pig model.

    abstract::Growth factors and morphogens secreted by bone marrow mesenchymal stem cells (BMSCs) of bone marrow fluid may promote tooth regeneration. Accordingly, a tissue engineering approach was utilized to develop an economical strategy for obtaining the growth factors and morphogens from BMSCs. Unerupted second molar tooth bu...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2010.01064.x

    authors: Kuo TF,Lin HC,Yang KC,Lin FH,Chen MH,Wu CC,Chang HH

    更新日期:2011-02-01 00:00:00

  • Dispersive aortic cannulas reduce aortic wall shear stress affecting atherosclerotic plaque embolization.

    abstract::Neurologic complications during on-pump cardiovascular surgery are often induced by mobilization of atherosclerotic plaques, which is directly related to enhanced wall shear stress. In the present study, we numerically evaluated the impact of dispersive aortic cannulas on aortic blood flow characteristics, with specia...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12359

    authors: Assmann A,Gül F,Benim AC,Joos F,Akhyari P,Lichtenberg A

    更新日期:2015-03-01 00:00:00

  • Dialysis reduces portal pressure in patients with chronic hepatitis C.

    abstract::The purpose of this study was to characterize changes in hepatic venous pressures in patients with chronic hepatitis C. The histology and laboratory data from patients with chronic hepatitis C who underwent a transjugular liver biopsy (TJLB) and hepatic venous pressure gradient measurement were analyzed. Portal hypert...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00925.x

    authors: Khurana S,Simcox T,Twaddell W,Drachenberg C,Flasar M

    更新日期:2010-07-01 00:00:00

  • End-point temperature of rewarming after hypothermic cardiopulmonary bypass in pediatric patients.

    abstract::In an attempt to find an adequate end-point rewarming temperature after hypothermic cardiopulmonary bypass (CPB), 50 pediatric patients who underwent cardiac surgery were randomly assigned for the end-point rectal rewarming temperature at either 35.5 (Group 1) or 37.0 degrees C (Group 2). The patients' rectal temperat...

    journal_title:Artificial organs

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/j.1525-1594.2005.00149.x

    authors: Kim WG,Yang JH

    更新日期:2005-11-01 00:00:00

  • Simple evaluation method of biocompatibility of artificial oxygenator hollow fiber.

    abstract::We made miniature modules filled with artificial oxygenator hollow fibers and conducted a simple experiment to study the effect of different membrane structures on the blood. Three types of modules were made: one filled with polyolefin, one filled with polypropylene, and a blank module. The 3 modules were connected th...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1525-1594.1996.tb00677.x

    authors: Nishida H,Shibuya M,Endo M,Koyanagi H

    更新日期:1996-12-01 00:00:00

  • Changes in albumin/platelet interaction with an artificial surface--due to a antibiotics, pyridoxal phosphate, and lymphocytes.

    abstract::Protein adsorption and platelet adhesion are two important biological processes arising at the blood prosthetic interface. The effect of certain antibiotics, namely, neomycin, gentamicin, ampicillin, penicillin-G, and streptomycin to modulate the albumin polycarbonate surface interaction was investigated using 125I al...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1988.tb02747.x

    authors: Chandy T,Sharma CP

    更新日期:1988-04-01 00:00:00

  • A novel, valveless ventricular assist device: the FishTail pump. First experimental in vivo studies.

    abstract::This article presents the first in vivo experiments with a new type of valveless ventricular assist device, a wave-generating pump. Our goal was to evaluate the hemodynamic performance of the pump by comparing it with the Biomedicus BP-80 centrifugal pump and by sustaining a 3 h long left ventricular assistance. We co...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2002.06973.x

    authors: Feier H,Mekkaoui C,Drevet JB,Sérée Y,Richomme C,Rolland PH,Mesana TG

    更新日期:2002-12-01 00:00:00

  • Effects of inhaled nitric oxide on postoperative pulmonary circulation in patients with congenital heart disease.

    abstract::We studied 22 patients with residual pulmonary hypertension or symptoms of postoperative pulmonary hypertensive crisis. They received low-dose inhalation (10 ppm) of nitric oxide (NO), a selective pulmonary vasodilator, after total correction for congenital heart anomalies. Fifteen minutes of NO inhalation improved th...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1525-1594.1997.tb00692.x

    authors: Matsui J,Yahagi N,Kumon K,Hayashi H,Watanabe Y,Haruna M,Tanigami H,Yagihara T,Takamoto S,Kamiya T

    更新日期:1997-01-01 00:00:00

  • An in vitro investigation into the hemodynamic effects of orifice geometry and position on left ventricular vortex formation and turbulence intensity.

    abstract::In a healthy human cardiac system, a large asymmetric clockwise vortex present in the left ventricle (LV) efficiently diverts the filling jet from the mitral annulus to the left ventricular outflow track. However, prior clinical studies have shown that artificial mitral valve replacement can affect the formation of ph...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13781

    authors: Tan SG,Hon JKF,Nguyen YN,Kim S,Leo HL

    更新日期:2020-12-01 00:00:00