Abstract:
:Although current continuous-flow total artificial hearts (CFTAHs) are much smaller than previous models, venous kinking may still occur after device implantation, especially in smaller animals. By inserting a self-expanding stent at the site of venous narrowing in a sheep model implanted with a CFTAH, we were able to restore the normal venous geometry and dramatically increase the CFTAH output. Because this percutaneous approach avoids the challenges associated with reoperation in these cases, it may be useful to other CFTAH investigators.
journal_name
Artif Organsjournal_title
Artificial organsauthors
Tuzun E,Parnis S,Rios J,Winkler JA,Cohn WEdoi
10.1111/j.1525-1594.2011.01233.xsubject
Has Abstractpub_date
2011-07-01 00:00:00pages
E161-3issue
7eissn
0160-564Xissn
1525-1594journal_volume
35pub_type
杂志文章abstract::Ten dialysis patients were followed in a prospective study to determine the neurotoxicity of metabolites in the middle molecule (MM) molecular weight (mol wt) range of 500-200 daltons/molecule. In the absence of readily available direct serum measurements of MM concentrations, a theoretically calculated dialysis index...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1978.tb01002.x
更新日期:1978-02-01 00:00:00
abstract::Hypoalbuminemia, a strong predictor of morbidity and mortality in hemodialysis patients, can be a consequence of a combination of malnutrition and inflammatory reactions. The purpose of this study was to analyze serum albumin as a marker of nutritional status in maintenance hemodialysis patients with no signs of infla...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.2003.07273.x
更新日期:2003-08-01 00:00:00
abstract::In 1993, the development began of a small axial flow blood pump, the DeBakey ventricular assist device (VAD). The material was recently converted to a titanium alloy, and a waterproof pump package was incorporated for long-term intracorporeal circulation. Thirteen intrathoracic implantations in calves were achieved. N...
journal_title:Artificial organs
pub_type: 临床试验,杂志文章
doi:10.1046/j.1525-1594.1999.06300.x
更新日期:1999-12-01 00:00:00
abstract::A centrifugal blood pump with a double pivot impeller and an eccentric inlet port is being developed as an implantable artificial heart by the Baylor College of Medicine and Miwatec Co. Ltd. Flow visualization measurements were conducted to compare the flow around the pivot for two impeller operational modes: the top ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2006.00155.x
更新日期:2006-01-01 00:00:00
abstract::We aimed to investigate whether acellular endocardium can be used as a useful biomaterial for the intima of engineered small-caliber vascular grafts. Fresh endocardium was harvested from the swine left atrium and was decellularized by digestion with the decellularization solution of Triton X-100 and SDS containing DNa...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.12814
更新日期:2016-12-01 00:00:00
abstract::The combination of hypothermia and potassium cardioplegic arrest has become the most common method of myocardial protection in the evolution of myocardial protection. This review focuses on myocardial protection in pediatric cardiac surgery. In the 1980s, blood was added to cardioplegia solution in order to supply the...
journal_title:Artificial organs
pub_type: 杂志文章,评审
doi:10.1111/aor.12029
更新日期:2013-01-01 00:00:00
abstract::Malfunction of bileaflet mechanical heart valves in the mitral position could either be due to patient-prosthesis mismatch (PPM) or leaflet obstruction. The aim of this article is to investigate the validity of current echocardiographic criteria used for diagnosis of mitral prosthesis malfunction, namely maximum veloc...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.12653
更新日期:2016-05-01 00:00:00
abstract::To provide percutaneous access, a new circulatory assist system was developed. We call this newly developed system the modified assist device (MAD). The system is composed of a sac-type blood pump and cannula. Inflow and outflow valves are mounted in the apex and at the side wall 10 cm from the apex of the cannula, re...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1996.tb00718.x
更新日期:1996-02-01 00:00:00
abstract::The PI3K/Akt signaling pathway has been implicated in playing an important role in platelet activation during hemostasis and thrombosis involving platelet-matrix interaction and platelet aggregation. Its role in non-physiological shear stress (NPSS)-induced platelet activation relevant to high-shear blood contacting m...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.13465
更新日期:2019-09-01 00:00:00
abstract::While pediatric HeartWare HVAD application has increased, determining candidacy and timing for initiation of pediatric VAD support has remained a challenge. We present our experience with a systematic approach to HVAD implantation as a bridge to pediatric heart transplantation. We performed a retrospective, single cen...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.13344
更新日期:2019-01-01 00:00:00
abstract::Renal Solutions Allient Sorbent Hemodialysis System utilizes a two-chambered pneumatic pump (Pulsar Blood Pump, Renal Solutions, Inc., Warrendale, PA, USA) to avoid limitations associated with peristaltic pumping systems. Single-needle access is enabled by counter-pulsing the two pump chambers, thereby obviating compl...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2009.00724.x
更新日期:2009-04-01 00:00:00
abstract::Aortic arch repair in newborns and infants has traditionally been accomplished using a period of deep hypothermic circulatory arrest. To reduce neurologic and cardiac dysfunction related to circulatory arrest and myocardial ischemia during complex aortic arch surgery, an alternative and novel strategy for cerebro-myoc...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.13128
更新日期:2018-04-01 00:00:00
abstract::This study deals with the design of a controller for cycling induced by functional electrical stimulation. The controller will be exploitable in the rehabilitation of hemiparetic patients who need to recover motor symmetry. It uses the pulse width as the control variable in the stimulation of the two legs in order to ...
journal_title:Artificial organs
pub_type: 临床试验,杂志文章
doi:10.1111/j.1525-1594.2009.00941.x
更新日期:2010-08-01 00:00:00
abstract::When cavitation occurs near a material surface of a mechanical heart valve (MHV), pits on the surface of the MHV and hemolysis are caused. Therefore, it is very important to investigate the possibility of the occurrence of cavitation in an MHV. To study the possibility of cavitation occurrence in a 25 mm Björk-Shiley ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.2003.06981.x
更新日期:2003-08-01 00:00:00
abstract::Filtration through membranes with different nominal cut-off was used for isolation of middle molecule fractions from uremic serum. Comparison was made with test substances which in gel filtration did not show a regular relationship between molecular weight and partition coefficient. The XM50 membrane (cut-off 50,000 D...
journal_title:Artificial organs
pub_type: 杂志文章
doi:
更新日期:1981-01-01 00:00:00
abstract::Cybernetics-based concepts can allow for complete independence for paralyzed individuals, including sensory motor recovery. Spinal cord injuries are responsible for a huge stress on health and a financial burden to society. This article focuses on novel procedures such as functional diagnosis for paraplegics and tetra...
journal_title:Artificial organs
pub_type: 杂志文章,评审
doi:10.1111/aor.12620
更新日期:2015-10-01 00:00:00
abstract::To develop artificial materials for prolonged use in the vascular system, the complicated process of surface-induced thrombosis needs to be better understood. It is documented that certain antihypertensive drugs can inhibit platelet adhesion to an artificial surface; on the other hand, steroid drugs increase platelet ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:
更新日期:1991-06-01 00:00:00
abstract::We previously demonstrated that tumor necrosis factor-alpha (TNF-alpha) increased following a reduction in systemic blood flow to 60% or less of the original cardiac output using a left ventricular assist device (LVAD). The aim of this study was to investigate the effect of reducing systemic blood flow on tissue oxyge...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.2001.025001053.x
更新日期:2001-01-01 00:00:00
abstract::A galactosamine-induced fulminant hepatic failure (FHF) rat model was used to study the effects of homologous cross-circulation and in situ liver perfusion. Cross-circulation with homologous donors did not significantly improve the survival time or recovery rate of grade II hepatic coma rats. Homologous in situ liver ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1980.tb03929.x
更新日期:1980-08-01 00:00:00
abstract::This study assessed the efficacy of multiarterial bypass in coronary artery bypass grafting (CABG) in dialysis patients. Eighty dialysis patients who underwent CABG were divided into 2 groups. Group A consisted of 38 patients in whom the left internal thoracic artery and additional saphenous vein graft (SVG) had been ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:
更新日期:2001-04-01 00:00:00
abstract::The aim of this study was to develop procedures for the diagnosis and nonsurgical management of decreased insulin flow in an implantable programmable pump for long-term intraperitoneal or intravenous insulin delivery featuring a sideport. Patency of the catheter lumen was tested by measuring the time needed for sidepo...
journal_title:Artificial organs
pub_type: 临床试验,杂志文章
doi:10.1111/j.1525-1594.1996.tb04586.x
更新日期:1996-09-01 00:00:00
abstract::Growth factors and morphogens secreted by bone marrow mesenchymal stem cells (BMSCs) of bone marrow fluid may promote tooth regeneration. Accordingly, a tissue engineering approach was utilized to develop an economical strategy for obtaining the growth factors and morphogens from BMSCs. Unerupted second molar tooth bu...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2010.01064.x
更新日期:2011-02-01 00:00:00
abstract::Neurologic complications during on-pump cardiovascular surgery are often induced by mobilization of atherosclerotic plaques, which is directly related to enhanced wall shear stress. In the present study, we numerically evaluated the impact of dispersive aortic cannulas on aortic blood flow characteristics, with specia...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.12359
更新日期:2015-03-01 00:00:00
abstract::The purpose of this study was to characterize changes in hepatic venous pressures in patients with chronic hepatitis C. The histology and laboratory data from patients with chronic hepatitis C who underwent a transjugular liver biopsy (TJLB) and hepatic venous pressure gradient measurement were analyzed. Portal hypert...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2009.00925.x
更新日期:2010-07-01 00:00:00
abstract::In an attempt to find an adequate end-point rewarming temperature after hypothermic cardiopulmonary bypass (CPB), 50 pediatric patients who underwent cardiac surgery were randomly assigned for the end-point rectal rewarming temperature at either 35.5 (Group 1) or 37.0 degrees C (Group 2). The patients' rectal temperat...
journal_title:Artificial organs
pub_type: 杂志文章,随机对照试验
doi:10.1111/j.1525-1594.2005.00149.x
更新日期:2005-11-01 00:00:00
abstract::We made miniature modules filled with artificial oxygenator hollow fibers and conducted a simple experiment to study the effect of different membrane structures on the blood. Three types of modules were made: one filled with polyolefin, one filled with polypropylene, and a blank module. The 3 modules were connected th...
journal_title:Artificial organs
pub_type: 临床试验,杂志文章
doi:10.1111/j.1525-1594.1996.tb00677.x
更新日期:1996-12-01 00:00:00
abstract::Protein adsorption and platelet adhesion are two important biological processes arising at the blood prosthetic interface. The effect of certain antibiotics, namely, neomycin, gentamicin, ampicillin, penicillin-G, and streptomycin to modulate the albumin polycarbonate surface interaction was investigated using 125I al...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1988.tb02747.x
更新日期:1988-04-01 00:00:00
abstract::This article presents the first in vivo experiments with a new type of valveless ventricular assist device, a wave-generating pump. Our goal was to evaluate the hemodynamic performance of the pump by comparing it with the Biomedicus BP-80 centrifugal pump and by sustaining a 3 h long left ventricular assistance. We co...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.2002.06973.x
更新日期:2002-12-01 00:00:00
abstract::We studied 22 patients with residual pulmonary hypertension or symptoms of postoperative pulmonary hypertensive crisis. They received low-dose inhalation (10 ppm) of nitric oxide (NO), a selective pulmonary vasodilator, after total correction for congenital heart anomalies. Fifteen minutes of NO inhalation improved th...
journal_title:Artificial organs
pub_type: 临床试验,杂志文章
doi:10.1111/j.1525-1594.1997.tb00692.x
更新日期:1997-01-01 00:00:00
abstract::In a healthy human cardiac system, a large asymmetric clockwise vortex present in the left ventricle (LV) efficiently diverts the filling jet from the mitral annulus to the left ventricular outflow track. However, prior clinical studies have shown that artificial mitral valve replacement can affect the formation of ph...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.13781
更新日期:2020-12-01 00:00:00