A novel, valveless ventricular assist device: the FishTail pump. First experimental in vivo studies.

Abstract:

:This article presents the first in vivo experiments with a new type of valveless ventricular assist device, a wave-generating pump. Our goal was to evaluate the hemodynamic performance of the pump by comparing it with the Biomedicus BP-80 centrifugal pump and by sustaining a 3 h long left ventricular assistance. We connected the two pumps in parallel and switched between them. We increased the aspiration by increments of -10 mm Hg at the inlet and measured developed flow, right carotid and femoral pressure, left atrial pressure, and left carotid flow. Then, we let the FishTail perform a 3 h long left ventricular assistance. The mean developed flow on the outlet was higher with the FishTail, with statistical significance, but this difference was not clinically significant. However, we observed an important amount of hemolysis during the ventricular assistance period. Although promising, this novel pumping device needs further prototypes to be clinically applicable.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Feier H,Mekkaoui C,Drevet JB,Sérée Y,Richomme C,Rolland PH,Mesana TG

doi

10.1046/j.1525-1594.2002.06973.x

subject

Has Abstract

pub_date

2002-12-01 00:00:00

pages

1026-31

issue

12

eissn

0160-564X

issn

1525-1594

pii

aor6973

journal_volume

26

pub_type

杂志文章
  • Visually guided performance of simple tasks using simulated prosthetic vision.

    abstract::Loss of photoreceptor cells is one of the major causes of blindness. Several groups are exploring the functional replacement of photoreceptors by a retinal prosthesis. The goal of this study was to simulate the vision levels that recipients of retinal prostheses with 4 x 4, 6 x 10, and 16 x 16 electrode arrays may exp...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2003.07309.x

    authors: Hayes JS,Yin VT,Piyathaisere D,Weiland JD,Humayun MS,Dagnelie G

    更新日期:2003-11-01 00:00:00

  • First experiences with outpatient care of patients with implanted axial flow pumps.

    abstract::As known from patients with pulsatile ventricular assist devices (VADs), early mobilization, physical exercise, and return to normal life are essential for optimal recovery. Recently, implantable rotary pumps became available for extended left ventricular support as bridges to transplantation. Modified procedures are ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2001.025005331.x

    authors: Wieselthaler GM,Schima H,Dworschak M,Quittan M,Nuhr M,Czerny M,Seebacher G,Huber L,Grimm M,Wolner E

    更新日期:2001-05-01 00:00:00

  • Influence of different heparin concentrations on the results of in vitro investigations in plasmaseparation technology using capillary membrane filters.

    abstract::Capillary membrane filters are devices commonly used for plasmapheresis and recirculating detoxification systems, including plasmaseparation units. Besides clinical trials and case reports, research on plasmafiltration techniques is carried out using in vitro systems. Notably, such hemoperfused in vitro systems requir...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2003.07132.x

    authors: Unger JK,Haltern C,Dohmen B,Rossaint R

    更新日期:2003-07-01 00:00:00

  • The effect of electrode placement and interphase interval on force production during stimulation of the dorsiflexor muscles.

    abstract::The aims of this study were to investigate whether introducing an interphase interval (IPI) to biphasic pulses during stimulation of the dorsiflexor muscles would affect force production and to determine whether the IPI effect is dependent on electrode position. Twelve healthy volunteers participated in the study. Eac...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12346

    authors: Springer S,Braun-Benyamin O,Abraham-Shitreet C,Becher M,Laufer Y

    更新日期:2014-11-01 00:00:00

  • Surgical use of fluosol-DA in Jehovah's Witness patients.

    abstract::The effects of Fluosol-DA 20% on circulating blood cells, hemodynamic parameters, blood gases, and organs are described and compared with the results of phase I human studies and animal experiments. Bleeding of preoperative anemia and/or surgical bleeding, Fluosol-DA 20% was administered to 7 of 10 Jehovah's Witness p...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1984.tb04238.x

    authors: Ohyanagi H,Nakaya S,Okumura S,Saitoh Y

    更新日期:1984-02-01 00:00:00

  • Intestinal tissue oxygenation and tumor necrosis factor-alpha release during systemic blood flow changes in pigs with left ventricular assist devices.

    abstract::We previously demonstrated that tumor necrosis factor-alpha (TNF-alpha) increased following a reduction in systemic blood flow to 60% or less of the original cardiac output using a left ventricular assist device (LVAD). The aim of this study was to investigate the effect of reducing systemic blood flow on tissue oxyge...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2001.025001053.x

    authors: Uozaki Y,Dihmis WC,Yamauchi H,Moczar M,Miyama M,Pasteau F,Tixier D,Bambang SL,Loisance DY

    更新日期:2001-01-01 00:00:00

  • Estimation of the native cardiac output from a rotary blood pump flow: in vitro study.

    abstract::The rotary blood pump will be an implantable left ventricular assist device (LVAD) in the near future. However, the best control method and the interrelationship between the rotary blood pump and native heart functions are unclear. An estimation was made of the native heart cardiac output from the change of an LVAD's ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.06127.x

    authors: Nakata K,Ohashi Y,Tayama E,Ohtsuka G,Takami Y,Mueller J,Glueck J,Nosé Y

    更新日期:1998-05-01 00:00:00

  • Plasmapheresis-related hypotension.

    abstract::Hypotension is an uncommon complication of procedures involving extracorporeal circulation, including plasmapheresis. From November 1993 to March 1999, we treated 139 patients who underwent a total of 1,137 sessions of double filtration plasmapheresis (DFP). Hypotension was defined as a systolic blood pressure (BP) < ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06521.x

    authors: Yeh JH,Chiu HC

    更新日期:2000-09-01 00:00:00

  • Testosterone and hemoglobin in hemodialysis male and female patients.

    abstract::It has been speculated that testosterone stimulates erythropoiesis. We hypothesized that hemoglobin levels in hemodialysis (HD) patients are associated with serum testosterone concentrations. Testosterone, hemoglobin, and other biochemical parameters were measured in a representative sample of 98 chronic HD patients (...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12218

    authors: Ekart R,Taskovska M,Hojs N,Bevc S,Hojs R

    更新日期:2014-07-01 00:00:00

  • Totally Endoscopic Robotic-Assisted Cardiac Surgery in Children.

    abstract::Robotic surgery for intracardiac pathologies in children is relatively uncommon. This study presents our initial experience with robotic-assisted cardiac surgery in children. We also present the feasibility and safety of robotic surgery in children. From May 2013 to June 2018, 30 children underwent totally endoscopic ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13357

    authors: Onan B,Aydin U,Kadirogullari E,Onan IS,Sen O

    更新日期:2019-04-01 00:00:00

  • A pilot study of piracetam in cuprophan hemodialysis.

    abstract::Twelve patients, 8 male and 4 female, aged from 26 to 70 years were studied. They were on hemodialysis (HD) 4 h three times weekly with cuprophan hollow fiber dialyzers (Gambro 120M) and dialysate containing 35 mEq/L of acetate. The study compares two random HD sessions on each patient. Sixty minutes prior to one rand...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1111/j.1525-1594.1989.tb01551.x

    authors: Grekas D,Alivanis P,Karamouzis M,Pyrpasopoulos M,Tourkantonis A

    更新日期:1989-10-01 00:00:00

  • Effects of scaling on centrifugal blood pumps.

    abstract::Experimental studies on the effects of scaling on the performance of centrifugal blood pumps were conducted in a closed-loop test rig. For the prototype, eight different impellers of the same outer diameter of 25 mm were tested at 1,500, 2,000, and 2,500 revolutions per minute (rpm) using blood analog as fluid medium....

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2002.07119.x

    authors: Wong YW,Chan WK,Yu SC,Chua LP

    更新日期:2002-11-01 00:00:00

  • Bacterial and fungal infection in neonates undergoing venoarterial extracorporeal membrane oxygenation: an analysis of the registry data of the extracorporeal life support organization.

    abstract::A review and analysis of 5,001 neonatal venoarterial (VA) extracorporeal membrane oxygenation (ECMO) cases showed that bacterial and fungal infection occurred in 147 (2.9%) and 26 (0.6%) patients, respectively, with an overall incidence of 3.5%. Bivariate analysis was used to compare infected infants with controls, ba...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1996.tb04428.x

    authors: Douglass BH,Keenan AL,Purohit DM

    更新日期:1996-03-01 00:00:00

  • Device exchange versus nonexchange modalities in left ventricular assist device-specific infections: A systematic review and meta-analysis.

    abstract::No standardized treatment algorithm exists for the management of continuous-flow left ventricular assist device (CF-LVAD)-specific infections. The aim of this systematic review and meta-analysis was to compare the outcomes of CF-LVAD-specific infections as managed by device exchange to other treatment modalities not i...

    journal_title:Artificial organs

    pub_type: 杂志文章,meta分析

    doi:10.1111/aor.13378

    authors: Bauer TM,Choi JH,Luc JGY,Weber MP,Moncho Escrivá E,Patel S,Maynes EJ,Boyle AJ,Samuels LE,Entwistle JW,Morris RJ,Massey HT,Tchantchaleishvili V

    更新日期:2019-05-01 00:00:00

  • Restoration of muscle volume and shape induced by electrical stimulation of denervated degenerated muscles: qualitative and quantitative measurement of changes in rectus femoris using computer tomography and image segmentation.

    abstract::This study demonstrates in a novel way how volume and shape are restored to denervated degenerated muscles due to a special pattern of electrical stimulation. To this purpose, Spiral Computer Tomography (CT) and special image processing tools were used to develop a method to isolate the rectus femoris from other muscl...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00610.x

    authors: Gargiulo P,Vatnsdal B,Ingvarsson P,Knútsdóttir S,Gudmundsdóttir V,Yngvason S,Helgason T

    更新日期:2008-08-01 00:00:00

  • Are the Current Doppler Echocardiography Criteria Able to Discriminate Mitral Bileaflet Mechanical Heart Valve Malfunction? An In Vitro Study.

    abstract::Malfunction of bileaflet mechanical heart valves in the mitral position could either be due to patient-prosthesis mismatch (PPM) or leaflet obstruction. The aim of this article is to investigate the validity of current echocardiographic criteria used for diagnosis of mitral prosthesis malfunction, namely maximum veloc...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12653

    authors: Evin M,Guivier-Curien C,Pibarot P,Kadem L,Rieu R

    更新日期:2016-05-01 00:00:00

  • Evaluation of platelet adhesion and activation on materials for an implantable centrifugal blood pump.

    abstract::A totally implantable centrifugal artificial heart has been developed in which a pivot bearing supported centrifugal pump is used as a blood pump. The following have been adopted as blood contacting materials in our pump: titanium alloy (Ti-6A1-4V) for the housing and impeller, alumina ceramic (Al2O3) for the male piv...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.6184r.x

    authors: Takami Y,Yamane S,Makinouchi K,Niimi Y,Sueoka A,Nosé Y

    更新日期:1998-09-01 00:00:00

  • Substitution of acetic acid for hydrochloric acid in the bicarbonate buffered dialysate.

    abstract::In a multicenter study including 5 dialysis units, blood acetate changes during 4 h dialysis sessions in 141 patients treated with a 4 mM acetate-containing bicarbonate dialysate (ABD) were evaluated and compared to the values of 114 patients using an acetate-free bicarbonate dialysate (AFD). Acetate-free bicarbonate ...

    journal_title:Artificial organs

    pub_type: 杂志文章,多中心研究

    doi:10.1046/j.1525-1594.1998.06205.x

    authors: Fournier G,Potier J,Thébaud HE,Majdalani G,Ton-That H,Man NK

    更新日期:1998-07-01 00:00:00

  • Adult polycystic kidney disease: who needs hospital follow-up?

    abstract::Clinical data from 120 adult patients with genetically undifferentiated polycystic kidney disease who had been followed up for more than 3 months (range 3-172) were reviewed in order to try to identify clinical indicators that might predict deterioration in renal function. They were split into two groups dependent on ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2012.01441.x

    authors: Griveas I,Bishop K,World M

    更新日期:2012-07-01 00:00:00

  • Effects of uremic toxin p-cresol on proliferation, apoptosis, differentiation, and glucose uptake in 3T3-L1 cells.

    abstract::Malnutrition is a common feature seen in chronic dialysis patients, and the survival rate of obese patients receiving such treatment is higher than that of lean patients. Irrespective of obesity or diabetes, dialysis patients commonly have insulin resistance, and the leading cause of death is cardiovascular (CV) disea...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12252

    authors: Tanaka S,Yano S,Sheikh AM,Nagai A,Sugimoto T

    更新日期:2014-07-01 00:00:00

  • Hybrid assembly of metal head and femoral stem from different manufacturers during isolated acetabular revision.

    abstract::During revision of a failed acetabular component with well-fixed antiquated femoral stem, the same variant of metal head is usually not available in the inventory production. We gathered the stems retrieved from revision surgeries and tried to reassemble with the commercially available femoral heads. This study report...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2010.01015.x

    authors: Chen CF,Chen WM,Yang CT,Huang CK,Chen TH

    更新日期:2010-08-01 00:00:00

  • Circulatory support for patients experiencing postcardiotomy cardiogenic shock: analysis of risk factors for death and long-term follow-up.

    abstract::Over the last 5 years, 12 patients received ventricular assist devices (VADs) while in postcardiotomy cardiogenic shock. There were 7 male and 5 female patients ranging in age from 22 to 73 years (average age, 54). Eight patients underwent surgery for valve replacements, 3 for coronary artery bypass graftings, and 1 f...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1993.tb00608.x

    authors: Murakami T,Nakayama H,Irie H,Kino K,Hisamochi K,Koomoto T,Takagaki M,Sugawara E,Senoo Y,Teramoto S

    更新日期:1993-07-01 00:00:00

  • Respiratory gas exchange through the hydrophilic membrane.

    abstract::To assess the efficiency of respiratory gas exchange in vitro through a dialysis membrane mounted inside a flat plate Kiil dialyzer, the model reactions of hydrogen peroxide reduction by a metal ion and of the carbon dioxide precipitation in the form of a carbonate in the dialysate were used. A comparison of the rates...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1983.tb04189.x

    authors: Zborowski M

    更新日期:1983-05-01 00:00:00

  • Comparison of a New Miniaturized Extracorporeal Membrane Oxygenation System With Integrated Rotary Blood Pump to a Standard System in a Porcine Model of Acute Lung Injury.

    abstract::Extracorporeal membrane oxygenation (ECMO) is used for severe acute respiratory distress syndrome. However, available ECMO systems are large and not well designed for fast delivery, emergency implantation, and interhospital transfer. Therefore, a new miniaturized oxygenator with integrated rotary blood pump (ILIAS) wa...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12611

    authors: Pilarczyk K,Heckmann J,Lyskawa K,Strauß A,Haake N,Wiese I,Jakob H,Kamler M,Pizanis N

    更新日期:2016-07-01 00:00:00

  • Renal complications of infected ventriculoatrial shunts.

    abstract::Contamination of a ventriculoatrial shunt (VAS) with skin organisms that are usually nonpathogenic may be followed by an immunologically mediated renal injury. The bacteria characteristically involved are coagulase-negative Staphylococci (e.g., Staphylococcus epidermidis), which strongly adhere to the plastic surface ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1993.tb00617.x

    authors: Samtleben W,Bauriedel G,Bosch T,Goetz C,Klare B,Gurland HJ

    更新日期:1993-08-01 00:00:00

  • Cytotoxicity and genotoxicity of bovine pericardium preserved in glycerol.

    abstract::Bovine pericardium is a widely utilized biomaterial. Usually, after harvesting, it is advantageous that the pericardium be immersed in glycerol to improve its shelf life. This can induce some degree of toxicity in the material. The studies were performed in compliance with the rules of ISO 10993 and OECD 487, in the b...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00542.x

    authors: Rodas AC,Maizato MJ,Leirner AA,Pitombo RN,Polakiewicz B,Beppu MM,Higa OZ

    更新日期:2008-04-01 00:00:00

  • Development of a flow estimation and control system of an implantable centrifugal blood pump for circulatory assist.

    abstract::A bypass flow rate estimation and control system (BECS) for an implantable centrifugal blood pump (ICBP) has been developed in our institute. The estimated flow rate (EF) of the ICBP was derived from the electric power consumption, the rotating speed of a motor, and the blood viscosity presumed by the hematocrit and b...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.06130.x

    authors: Wakisaka Y,Okuzono Y,Taenaka Y,Chikanari K,Endo S,Masuzawa T,Takano H

    更新日期:1998-06-01 00:00:00

  • Microcirculation and artificial heart research.

    abstract::Small blood vessels may play a more important role in artificial heart (AH) recipients than ever suspected before. Observations of elevated total peripheral resistance, low hematocrit, reduced oncotic pressure, high circulating blood volume, and arterial pulsations with nonpulsatile devices require consideration of pe...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1988.tb01529.x

    authors: Lübbe AS

    更新日期:1988-02-01 00:00:00

  • Effect of cyclosporine therapy with low doses of corticosteroids on idiopathic nephrotic syndrome.

    abstract::Cyclosporine (CyA) has an immunosuppressive effect that might suggest a therapeutic role in idiopathic glomerular conditions. We focused on the optimization of CyA treatment control in patients with idiopathic nephrotic syndrome by using trough-level CyA measurements (C0) and the 2-h postdose levels (C2). Twenty-two p...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00838.x

    authors: Griveas I,Visvardis G,Papadopoulou D,Nakopolou L,Karanikas E,Gogos K,Stavianoudakis G

    更新日期:2010-03-01 00:00:00

  • Tissue-engineered skin containing mesenchymal stem cells improves burn wounds.

    abstract::There is increasing evidence showing that adult stem cells are useful for tissue regeneration. Bone marrow mesenchymal stem cells (MSCs) are self-renewing and are potent in differentiating into multiple cells and tissues. To investigate the practicability of repairing burn wounds with tissue-engineered (TE) skin combi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00654.x

    authors: Liu P,Deng Z,Han S,Liu T,Wen N,Lu W,Geng X,Huang S,Jin Y

    更新日期:2008-12-01 00:00:00