A pilot study of piracetam in cuprophan hemodialysis.

Abstract:

:Twelve patients, 8 male and 4 female, aged from 26 to 70 years were studied. They were on hemodialysis (HD) 4 h three times weekly with cuprophan hollow fiber dialyzers (Gambro 120M) and dialysate containing 35 mEq/L of acetate. The study compares two random HD sessions on each patient. Sixty minutes prior to one random session a placebo was administered orally, and prior to another random session piracetam was given at a dose of 8 g. Heparin dosage was not reduced during HD using QB 200 ml, QD 500 ml, and no ultrafiltration. Blood samples for leukocyte and platelet counts, serum C3, arterial paO2 and paCO2, thromboxane-B2 (TxB2), and beta-thromboglobulin (beta-TG) were taken from the arterial line before and at 15, 60, and 240 min during HD. Leukopenia at 15 min of HD was found to be less severe (p less than 0.01) in the piracetam study than in the placebo, whereas platelet count did not change. Serum C3 was slightly increased in both studies. Arterial oxygen was preserved close to the initial levels by piracetam (91.66 mm Hg versus 81.08, p less than 0.01 at 60 min, and 93.08 versus 80.17 mm Hg, p less than 0.01 at 240 min of HD sessions) but paCO2 did not change significantly. TxB2 increased less with piracetam in comparison to placebo (p less than 0.01 or p less than 0.001), but beta-TG was reduced significantly by piracetam at any time during HD (p less than 0.001).(ABSTRACT TRUNCATED AT 250 WORDS)

journal_name

Artif Organs

journal_title

Artificial organs

authors

Grekas D,Alivanis P,Karamouzis M,Pyrpasopoulos M,Tourkantonis A

doi

10.1111/j.1525-1594.1989.tb01551.x

subject

Has Abstract

pub_date

1989-10-01 00:00:00

pages

422-6

issue

5

eissn

0160-564X

issn

1525-1594

journal_volume

13

pub_type

临床试验,杂志文章,随机对照试验
  • Thrombogenicity of deflated intraaortic balloon: impact of heparin coating.

    abstract::In a calf model, 3 standard and 3 heparin coated intraaortic balloons (IAB) were inserted and left deflated in the descending aorta during 20 min to simulate balloon rupture. At the end of the experiment, the IAB were examined, and 3 samples of each were collected for scanning electron microscopy (SEM) analysis. None ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06228.x

    authors: Mueller XM,Tevaearai HT,Hayoz D,von Segesser LK

    更新日期:1999-02-01 00:00:00

  • Probing expert opinions on the future of kidney replacement therapies.

    abstract::Patients with kidney failure can only survive with some form of kidney replacement (transplant or dialysis). Unfortunately, innovations in kidney replacement therapy lag behind many other medical fields. This study compiles expert opinions on candidate technologies for future kidney replacement therapies. A worldwide ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13784

    authors: Pereira Cabral B,Bonventre JV,Wieringa F,Mota FB

    更新日期:2020-07-22 00:00:00

  • Building a Better Neonatal Extracorporeal Life Support Circuit: Comparison of Hemodynamic Performance and Gaseous Microemboli Handling in Different Pump and Oxygenator Technologies.

    abstract::Neurologic complications during neonatal extracorporeal life support (ECLS) are associated with significant morbidity and mortality. Gaseous microemboli (GME) in the ECLS circuit may be a possible cause. Advances in neonatal circuitry may improve hemodynamic performance and GME handling leading to reduction in patient...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12908

    authors: Glass K,Trivedi P,Wang S,Woitas K,Kunselman AR,Ündar A

    更新日期:2017-04-01 00:00:00

  • A new blood pump for cardiopulmonary bypass: the HiFlow centrifugal pump.

    abstract::Centrifugal blood pumps are considered to be generally superior to the traditionally used roller pumps in cardiopulmonary bypass. In our institute a new lightweight centrifugal sealless blood pump with a unique spherical thrust bearing and with a magnetic coupling was developed, the HiFlow. The small design makes the ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb03754.x

    authors: Göbel C,Eilers R,Reul H,Schwindke P,Jörger M,Rau G

    更新日期:1997-07-01 00:00:00

  • Evaluation of chitosan-alginate-hyaluronate complexes modified by an RGD-containing protein as tissue-engineering scaffolds for cartilage regeneration.

    abstract::In this study, a series of natural biodegradable materials in the form of chitosan (C)-alginate (A)-hyaluronate (H) complexes are evaluated as tissue-engineering scaffolds. The weight ratio of C/A is 1 : 1 or 1 : 2. Sodium hyaluronate is mixed in 2%. The complexes can be cast into films or fabricated as scaffolds. The...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2004.00046.x

    authors: Hsu SH,Whu SW,Hsieh SC,Tsai CL,Chen DC,Tan TS

    更新日期:2004-08-01 00:00:00

  • Combination of plasma exchange and continuous hemofiltration as temporary metabolic support for patients with acute liver failure.

    abstract::The combination of plasma exchange and continuous hemofiltration was applied to patients with acute liver failure, and its clinically advantageous effects were evaluated. This procedure was found to be a powerful approach in decreasing patient morbidity; however, the effect was temporary and the patients finally died....

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1994.tb02217.x

    authors: Matsubara S

    更新日期:1994-05-01 00:00:00

  • Venoarterial extracorporeal membrane oxygenation for postcardiotomy cardiogenic shock-A six-year service evaluation.

    abstract::Only a small number of English hospitals provide postcardiotomy venoarterial extracorporeal membrane oxygenation (VA-ECMO) and there are doubts about its efficacy and safety. The aim of this service evaluation was to determine local survival rates and report on patient demographics. This was a retrospective service ev...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13647

    authors: Charlesworth M,Garcia M,Head L,Barker JM,Ashworth AD,Barnard JB,Feddy L,Venkateswaran RV

    更新日期:2020-07-01 00:00:00

  • Kinetics of group IB and IIA phospholipase A2 during low-volume continuous hemodiafiltration in severe acute pancreatitis.

    abstract::Continuous hemodiafiltration (CHDF) has been performed for the treatment of severe acute pancreatitis. Phospholipase A2 (PLA2) is one of the important mediators which exacerbate acute pancreatitis, but whether PLA2 can be removed by CHDF is unclear. In this study, the kinetics of group IB and group IIA PLA2 was examin...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1525-1594.2007.00398.x

    authors: Suzuki M,Okahisa T,Sogabe M,Iwaki H,Okita Y,Ohnishi Y,Ito S

    更新日期:2007-05-01 00:00:00

  • Bone marrow combined with dental bud cells promotes tooth regeneration in miniature pig model.

    abstract::Growth factors and morphogens secreted by bone marrow mesenchymal stem cells (BMSCs) of bone marrow fluid may promote tooth regeneration. Accordingly, a tissue engineering approach was utilized to develop an economical strategy for obtaining the growth factors and morphogens from BMSCs. Unerupted second molar tooth bu...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2010.01064.x

    authors: Kuo TF,Lin HC,Yang KC,Lin FH,Chen MH,Wu CC,Chang HH

    更新日期:2011-02-01 00:00:00

  • Recharging the battery of implantable biomedical devices by light.

    abstract::This article describes a new powering system for implantable medical devices that could significantly increase their lifetime. The idea is based on the substitution of the usual implantable device battery for an electric accumulator (rechargeable battery), which is fed by the electric power generated by a photovoltaic...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00803.x

    authors: Algora C,Peña R

    更新日期:2009-10-01 00:00:00

  • A new technique to increase coronary flow. Preliminary report.

    abstract::This study was planned to investigate whether part of the energy produced by cardiac contraction to propel blood toward the systemic circulation can be used to increase the coronary flow in systole. Ten devices (I-X) designed to divert laterally part of a flow column (without substantially increasing resistance to flo...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1979.tb01080.x

    authors: Moulopoulos S,Stamatelopoulos S,Boufas D,Yannopoulos C,Marousis G,Kouvaras G

    更新日期:1979-11-01 00:00:00

  • Microcirculation and artificial heart research.

    abstract::Small blood vessels may play a more important role in artificial heart (AH) recipients than ever suspected before. Observations of elevated total peripheral resistance, low hematocrit, reduced oncotic pressure, high circulating blood volume, and arterial pulsations with nonpulsatile devices require consideration of pe...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1988.tb01529.x

    authors: Lübbe AS

    更新日期:1988-02-01 00:00:00

  • Gaseous micro-emboli activity during cardiopulmonary bypass in adults: pulsatile flow versus nonpulsatile flow.

    abstract::Cardiopulmonary bypass (CPB) has a risk of cerebral injury, with an important role of gaseous micro-emboli (GME) coming from the CPB circuit. Pulsatile perfusion is supposed to perform specific conditions for supplementary GME activity. We aimed to determine whether pulsatile CPB augments production and delivery of GM...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12000

    authors: Dodonov M,Milano A,Onorati F,Dal Corso B,Menon T,Ferrarini D,Tessari M,Faggian G,Mazzucco A

    更新日期:2013-04-01 00:00:00

  • Systemic consequences of ventricular assist devices: alterations of coagulation, immune function, inflammation, and the neuroendocrine system.

    abstract::Implantable ventricular assist devices have proven efficacious as a bridge to transplantation and as a bridge to recovery. Although current indications for use of assist devices are somewhat limited, they are likely to expand in the upcoming years, including their use as destination therapy for end-stage heart failure...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1046/j.1525-1594.2002.07122.x

    authors: Hampton CR,Verrier ED

    更新日期:2002-11-01 00:00:00

  • Is Multiple Overlapping Uncovered Stents Technique Suitable for Aortic Aneurysm Repair?

    abstract::A computational fluid dynamic model to assess the impact of flow-diverter device on intra-aneurysmal flow in complex aortic aneurysm from the viewpoint of hemodynamics is presented. The aim of this study is to investigate the hemodynamic effects of an endovascular flow-diverter technique using multiple overlapping unc...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12993

    authors: Yeow SL,Leo HL

    更新日期:2018-02-01 00:00:00

  • Dialyzer reuse: interaction between dialyzer membrane, disinfectant (formalin), and blood during dialyzer reprocessing.

    abstract::The growing practice of dialyzer reuse in recent years is mainly based on medical and economic considerations. However, adverse reactions such as immunohemolytic anemia due to anti-Nform antibody associated with dialyzer reuse have been reported. In this study, scanning electron microscopy and cytologic staining were ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1996.tb04418.x

    authors: Ng YY,Yang AH,Wong KC,Lan HY,Hung TL,Kerr PG,Huang TP

    更新日期:1996-01-01 00:00:00

  • Comparison of a New Miniaturized Extracorporeal Membrane Oxygenation System With Integrated Rotary Blood Pump to a Standard System in a Porcine Model of Acute Lung Injury.

    abstract::Extracorporeal membrane oxygenation (ECMO) is used for severe acute respiratory distress syndrome. However, available ECMO systems are large and not well designed for fast delivery, emergency implantation, and interhospital transfer. Therefore, a new miniaturized oxygenator with integrated rotary blood pump (ILIAS) wa...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12611

    authors: Pilarczyk K,Heckmann J,Lyskawa K,Strauß A,Haake N,Wiese I,Jakob H,Kamler M,Pizanis N

    更新日期:2016-07-01 00:00:00

  • Physiologic control of cardiac assist devices.

    abstract::Total artificial hearts (TAHs) and biventricular assist devices (BVADs) have varying levels of acceptance and reliability, and the research on both focuses on their control mechanisms. Efforts generally aim to achieve a response to physiologic demand and left/right output balance, and beneficial cardiac output (CO) an...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1996.tb04438.x

    authors: Hall AW,Soykan O,Harken AH

    更新日期:1996-03-01 00:00:00

  • Bulk mass transport limitations during high-flux hemodialysis.

    abstract::Solute clearance during high-flux hemodialysis is determined by the combined effects of solute convection and diffusion in the membrane, blood, and dialysate. Previous studies have focused almost entirely on the membrane transport phenomena, largely ignoring the potential contribution from bulk mass transport across t...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1993.tb00403.x

    authors: Zydney AL

    更新日期:1993-11-01 00:00:00

  • Oral treatment for jaundice using immobilized bilirubin oxidase.

    abstract::Jaundice is characterized by an excessive accumulation of bilirubin in the blood and tissues. A novel approach to reduce plasma levels of bilirubin by blocking its enterohepatic circulation was investigated. The treatment consisted of oral administration of immobilized bilirubin oxidase, which could oxidize bilirubin ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1992.tb00527.x

    authors: Soltys PJ,Mullon C,Langer R

    更新日期:1992-08-01 00:00:00

  • Optimal continuous retrograde coronary perfusion flow rate with beating heart in normal temperature.

    abstract:PURPOSE:We were led to the premise that with retrograde oxygenated blood perfusion, it would be possible to perform operations on the beating heart. METHODS:The experiment consisted of two stages: procedure 1 and 2. In procedure 1, six pigs were used. Retrograde perfusion flow was controlled to be in the range of 5.0-...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2004.47279.x

    authors: Tsukioka T,Tomita S,Watanabe G,Takemura H

    更新日期:2004-03-01 00:00:00

  • A comparative study between flow visualization and computational fluid dynamic analysis for the sun medical centrifugal blood pump.

    abstract::Flow visualization experiments and computational fluid dynamic (CFD) analyses were performed and the results were compared to clarify the detailed fluid dynamic characteristics for the prototype design of a centrifugal pump, namely, an implantable ventricular assist system from Sun Medical, whose hemocompatibility was...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2004.07161.x

    authors: Yamane T,Miyamoto Y,Tajima K,Yamazaki K

    更新日期:2004-05-01 00:00:00

  • Totally Endoscopic Robotic-Assisted Cardiac Surgery in Children.

    abstract::Robotic surgery for intracardiac pathologies in children is relatively uncommon. This study presents our initial experience with robotic-assisted cardiac surgery in children. We also present the feasibility and safety of robotic surgery in children. From May 2013 to June 2018, 30 children underwent totally endoscopic ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13357

    authors: Onan B,Aydin U,Kadirogullari E,Onan IS,Sen O

    更新日期:2019-04-01 00:00:00

  • Effect of heparin, platelets, activated platelets, platelet fragments, and hematocrit on activated clotting time.

    abstract::Activated clotting time (ACT) is the most commonly used laboratory test to control the heparin effect during extracorporeal techniques. The study was undertaken in order to test in vitro the influence of heparin, platelet count, hematocrit, platelet fragmentation, and platelet activation on ACT. Blood was drawn from v...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06552.x

    authors: Girardi L,Sudi K,Muntean W

    更新日期:2000-07-01 00:00:00

  • Significance of percutaneous cardiopulmonary bypass support for volume reduction surgery with severe hypercapnia.

    abstract::In patients with reduced respiratory function, lung resection is associated with high risk because separate ventilation is generally needed for safe management. For patients with end-stage emphysema, intraoperative respiratory management is important and particularly difficult because neither incomplete oxygenation no...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06339.x

    authors: Tsunezuka Y,Sato H,Tsubota M,Seki M

    更新日期:2000-01-01 00:00:00

  • Experimental study of a new method for early detection of vascular access stenoses: pulse pressure analysis at hemodialysis needle.

    abstract::Hemodialysis vascular access (VA) stenosis remains a frequent complication. However, early detection is challenging and costly. The aim of this in vitro study was to assess a new detection method based on pulse pressure analysis at the hemodialysis needle. A silicon model of a radiocephalic arteriovenous fistula was b...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00772.x

    authors: Van Canneyt K,Planken RN,Eloot S,Segers P,Verdonck P

    更新日期:2010-02-01 00:00:00

  • Unsteady fluid dynamics of several mechanical prosthetic heart valves using a two component laser Doppler anemometer system.

    abstract::Five typical mechanical heart valves (Starr-Edwards, Björk-Shiley convexo-concave (c-c), Björk-Shiley monostrut, Bicer-Val, and St. Jude Medical) were tested in the mitral position under the pulsatile flow condition. The test program included measurements of velocity and turbulent stresses at 5 downstream locations. T...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb00451.x

    authors: Akutsu T,Modi VJ

    更新日期:1997-10-01 00:00:00

  • Renal complications of infected ventriculoatrial shunts.

    abstract::Contamination of a ventriculoatrial shunt (VAS) with skin organisms that are usually nonpathogenic may be followed by an immunologically mediated renal injury. The bacteria characteristically involved are coagulase-negative Staphylococci (e.g., Staphylococcus epidermidis), which strongly adhere to the plastic surface ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1993.tb00617.x

    authors: Samtleben W,Bauriedel G,Bosch T,Goetz C,Klare B,Gurland HJ

    更新日期:1993-08-01 00:00:00

  • Anemia in acute renal failure: role for erythropoiesis-stimulating proteins?

    abstract::The use of recombinant human erythropoietin (rHuEpo) has revolutionized anemia management of early and late stages of chronic kidney disease. Darbopoietin is also now available for the treatment of anemia of chronic kidney disease. In addition, rHuEpo has been used for the treatment of anemia observed in critical illn...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1046/j.1525-1594.2003.07287.x

    authors: Liangos O,Pereira BJ,Jaber BL

    更新日期:2003-09-01 00:00:00

  • Microencapsulation of crystalline insulin or islets of Langerhans: an insulin diffusion study.

    abstract::Microcapsules containing insulin crystals or islets of Langerhans were made by extruding a mixture of insulin crystals or islets and sodium alginate into a calcium chloride solution, and then coating it with poly-l-lysine. When these microcapsules were incubated at 37 degrees C, insulin could be detected readily in th...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1983.tb04187.x

    authors: Leung YF,O'Shea GM,Goosen MF,Sun AM

    更新日期:1983-05-01 00:00:00