Eccentric roller type total artificial heart creating interatrial shunt.

Abstract:

:Creating an interatrial shunt to achieve left-right flow balance and modification of the blood chambers to improve the basic performance of the device were performed in developing an eccentric roller type total artificial heart (ERTAH). Smaller blood chambers reduce friction loss and increase durability and energy efficiency. We changed the left blood chamber volume of 60 ml to 40 ml and the right blood chamber volume of 53 ml to 35 ml compared with previous types. Designs of inlet and outlet ports were modified to prevent backflow. In the mock circulatory system, redesigning the blood chambers resulted in a 20% increase in energy efficiency, about a two-fold increase of cardiac output and improved durability compared to the previous type. In an animal experiment, the ERTAH operated at a driving rate of 160 rpm with a left flow rate of 6.0 L/min and a right flow rate of 5.4 L/min. Interatrial shunt flow rate was 250-400 ml/min.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Wada H,Fukunaga S,Watari M,Imai K,Sakai H,Shibamura H,Sueda T,Matsuura Y

doi

10.1046/j.1525-1594.2000.06602.x

subject

Has Abstract

pub_date

2000-08-01 00:00:00

pages

671-5

issue

8

eissn

0160-564X

issn

1525-1594

pii

aor6602

journal_volume

24

pub_type

杂志文章
  • The BiVACOR rotary biventricular assist device: concept and in vitro investigation.

    abstract::The BiVACOR is a novel rotary Biventricular Assist Device (BiVAD) undergoing development to treat global end-stage heart failure. The design includes left and right vanes positioned on a shared rotating hub to form a double-sided magnetically and hydrodynamically suspended centrifugal impeller. The performance of the ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00633.x

    authors: Timms D,Fraser J,Hayne M,Dunning J,McNeil K,Pearcy M

    更新日期:2008-10-01 00:00:00

  • Clinical experience with BioMedicus centrifugal ventricular support in 172 patients.

    abstract::One hundred and seventy-two patients at The Methodist Hospital in Houston, Texas, were placed on BioMedicus centrifugal ventricular support. One hundred thirty-nine patients were male and 33 were female with a mean age of 59.7 years. Reasons for support were postcardiotomy cardiac failure (129 patients), cardiac allog...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1995.tb02419.x

    authors: Noon GP,Ball JW Jr,Papaconstantinou HT

    更新日期:1995-07-01 00:00:00

  • Investigation of parameter estimator and adaptive controller for assist pump by computer simulation.

    abstract::The multi-output adaptive controller of a left ventricular assist device (LVAD) was studied by computer simulation. The controller regulated two outputs--mean aortic pressure (mAoP) and mean atrial pressure (mLAP)--by regulating vacuum pressure (input). The autoregressive models were used to describe the circulatory s...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1991.tb00769.x

    authors: Shimooka T,Mitamura Y,Yuhta T

    更新日期:1991-04-01 00:00:00

  • Reduction of early postoperative morbidity in cardiac surgery patients treated with continuous veno-venous hemofiltration during cardiopulmonary bypass.

    abstract::Cardiac surgery with cardiopulmonary bypass is associated with a systemic inflammatory response syndrome. The major clinical features of this include a reduction of pulmonary compliance and increased extracellular fluids, with increased pulmonary shunt fraction similar to acute respiratory distress syndrome, thus resu...

    journal_title:Artificial organs

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/j.1525-1594.2009.00777.x

    authors: Luciani R,Goracci M,Simon C,Principe F,Fazzari L,Punzo G,Menè P

    更新日期:2009-08-01 00:00:00

  • Centrifugal pumps and heparin-coated circuits in surgical treatment of giant cerebral aneurysms.

    abstract::Giant cerebral aneurysms may be untreatable by conventional neurosurgical techniques. Early attempts to use circulatory assistance and deep hypothermia were abandoned due to hemorrhagic complications. More recently, interest in circulatory support for complex neurosurgical procedures has been renewed. A consecutive se...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06594.x

    authors: Mesana T,Collart F,Caus T,Pomane C,Graziani N,Bruder N,Dufour H,Grisoli F,Montiès JR

    更新日期:2000-06-01 00:00:00

  • Computational simulation of a non-newtonian model of the blood separation process.

    abstract::The aim of this work is to construct a computational fluid dynamics model capable of simulating the transient non-Newtonian process of apheresis. A Lagrangian-Eulerian model has been developed which tracks the blood particles within a two-dimensional flow configuration. Within the Eulerian method, the fluid mass and m...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2005.00164.x

    authors: De Gruttola S,Boomsma K,Poulikakos D

    更新日期:2005-12-01 00:00:00

  • Development of a Tissue-Engineered Artificial Ligament: Reconstruction of Injured Rabbit Medial Collateral Ligament With Elastin-Collagen and Ligament Cell Composite Artificial Ligament.

    abstract::Ligament reconstruction using a tissue-engineered artificial ligament (TEAL) requires regeneration of the ligament-bone junction such that fixation devices such as screws and end buttons do not have to be used. The objective of this study was to develop a TEAL consisting of elastin-coated polydioxanone (PDS) sutures c...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13124

    authors: Hirukawa M,Katayama S,Sato T,Inoue K,Niwa K,Ito N,Hattori T,Hosoi T,Unno H,Suzuki Y,Hasegawa M,Miyamoto K,Horiuchi T

    更新日期:2018-07-01 00:00:00

  • Plasma middle molecules in asymptomatic and "sick" uremic patients.

    abstract::By using high speed gel filtration combined with ion exchange gradient elution chromatography, the concentrations of plasma (p) middle molecules (MM) were determined in 126 samples from 90 non-dialyzed azotemic patients and in 210 pre-dialysis samples from 53 regular hemodialysis and 24 intermittent peritoneal dialysi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors: Asaba H,Bergström J,Fürst P,Johnson C,Yahiel V

    更新日期:1981-01-01 00:00:00

  • Ferritin: a reliable indicator of iron supplementation in patients on chronic hemodialysis/hemofiltration treatment?

    abstract::Four hundred and forty-two serum ferritin determinations were performed in 144 patients on chronic intermittent hemodialysis treatment with intravenous iron substitution and/or oral iron substitution. Iron substitution should be done individually according to regular serum ferritin determinations. Intravenous iron sub...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1981.tb03980.x

    authors: Müller HA,Schneider H,Hövelborn U,Streicher E

    更新日期:1981-05-01 00:00:00

  • Biodegradation and biocompatibility of polyorganophosphazene.

    abstract::We investigated biodegradation and biocompatibility of poly(organophosphazenes). We prepared poly(organophosphazenes) having different side chain groups. The blood compatibility of poly(organophosphazenes) containing fluorinated side groups, poly(bis[trifluoroethoxy]phosphazene) (PbFP) and poly([trifluoroethoxy][ethyl...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2002.07029.x

    authors: Kawakami H,Kanezaki S,Sudo M,Kanno M,Nagaoka S,Kubota S

    更新日期:2002-10-01 00:00:00

  • Evaluation of cardiac beat synchronization control for a rotary blood pump on valvular regurgitation with a mathematical model.

    abstract::We have studied the cardiac beat synchronization (CBS) control for a rotary blood pump (RBP) and revealed that it can promote pulsatility and reduce cardiac load. Besides, patients with LVAD support sometimes suffer from aortic and mitral regurgitation (AR and MR). A control method for the RBP should be validated in w...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13795

    authors: Ogawa D,Kobayashi S,Yamazaki K,Motomura T,Nishimura T,Shimamura J,Tsukiya T,Mizuno T,Takewa Y,Tatsumi E,Nishinaka T

    更新日期:2020-08-19 00:00:00

  • Numerical Simulation of Nonpulsatile Left Ventricular Bypass.

    abstract::A computer simulation was carried out to investigate the influence of nonpulsatile left ventricular assistance on hemodynamics. A simulation circuit was constructed to represent the circulatory system. A source of current was added to denote the nonpulsatile blood pump. The left and right ventricles were replaced by v...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1996.tb04494.x

    authors: Mitsui N,Fukunaga S,Koura Y,Morita S,Hotei H,Sueshiro M,Sueda T,Matsuura Y

    更新日期:1996-05-01 00:00:00

  • Methodology for identification of serum middle molecules.

    abstract::Filtration through membranes with different nominal cut-off was used for isolation of middle molecule fractions from uremic serum. Comparison was made with test substances which in gel filtration did not show a regular relationship between molecular weight and partition coefficient. The XM50 membrane (cut-off 50,000 D...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors: Buzio C,Montagna G,Calderini C,Manari A,Migone L

    更新日期:1981-01-01 00:00:00

  • Microencapsulation of crystalline insulin or islets of Langerhans: an insulin diffusion study.

    abstract::Microcapsules containing insulin crystals or islets of Langerhans were made by extruding a mixture of insulin crystals or islets and sodium alginate into a calcium chloride solution, and then coating it with poly-l-lysine. When these microcapsules were incubated at 37 degrees C, insulin could be detected readily in th...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1983.tb04187.x

    authors: Leung YF,O'Shea GM,Goosen MF,Sun AM

    更新日期:1983-05-01 00:00:00

  • The mechanics of spiral flow: Enhanced washout and transport.

    abstract::Spiral/helical forms of blood flow have been observed in large arteries of the cardiovascular system, but their benefits remain underappreciated. Spiral flow has been postulated to improve near-wall washout, promoting anti-atherothrombotic conditions. This research aims to study the washout characteristics of spiral f...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13520

    authors: Huang Zhang P,Tkatch C,Newman R,Grimme W,Vainchtein D,Kresh JY

    更新日期:2019-12-01 00:00:00

  • Hemodynamic controller for left ventricular assist device based on pulsatility ratio.

    abstract::Hemodynamic control of left ventricular assist devices (LVADs) is generally a complicated problem due to diverse operating environments and the variability of the patients: both the changes in the circulatory and metabolic parameters as well as disturbances that require adjustment to the operating point. This challeng...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2007.00350.x

    authors: Choi S,Boston JR,Antaki JF

    更新日期:2007-02-01 00:00:00

  • Influence of Instruments Used in Root Canal Preparation on Amount of Apically Extruded Debris.

    abstract::The aim of the present study was to compare the effects of ProTaper Gold, WaveOne Gold, ProTaper Universal, and WaveOne instruments on the amount of apically extruded debris. Eighty mandibular premolar teeth with straight root canals were selected and assigned to four groups (n = 20). The root canals were instrumented...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12675

    authors: Karataş E,Ersoy İ,Gündüz HA,Uygun AD,Kol E,Çakıcı F

    更新日期:2016-08-01 00:00:00

  • Fluid dynamic characteristics of the VentrAssist rotary blood pump.

    abstract::The VentrAssist pump has no shaft or seal, and the device is unique in design because the rotor is suspended passively by hydrodynamic forces, and urging is accomplished by an integrated direct current motor rotor that also acts as the pump impeller. This device has led to many challenges in its fluidic design, namely...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06584.x

    authors: Tansley G,Vidakovic S,Reizes J

    更新日期:2000-06-01 00:00:00

  • Percutaneous introduction of left atrial cannula for left heart bypass: utility of biplane transesophageal echocardiographic guidance for transseptal puncture.

    abstract::For introduction of a left atrial (LA) cannula by the transseptal puncture technique, we examined the feasibility of using biplane transesophageal echocardiography (B-TEE). A transseptal puncture was performed on 15 patients (3 male; 12 female; mean age, 48.9 +/- 11.2 years) by B-TEE guide during percutaneous transven...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1992.tb00537.x

    authors: Kyo S,Motoyama T,Miyamoto N,Noda H,Dohi Y,Omoto R

    更新日期:1992-08-01 00:00:00

  • Effect of temporary catheter and late referral on hospitalization and mortality during the first year of hemodialysis treatment.

    abstract::Late referral (LR) to dialysis therapy has been associated with poor outcomes in people with end-stage renal disease. This had been ascribed to the frequent use of temporary vascular catheters (TVCs) in LR patients. The effects of LR and TVC on the outcomes of an incident hemodialysis population (n = 101) were investi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2004.00016.x

    authors: Gonçalves EA,Andreoli MC,Watanabe R,Freitas MC,Pedrosa AC,Manfredi SR,Draibe SA,Cendoroglo M,Canziani ME

    更新日期:2004-11-01 00:00:00

  • Evidence of absence of porcine endogenous retrovirus (PERV) infection in patients treated with a bioartificial liver support system.

    abstract::Porcine endogenous retrovirus (PERV) genomes are present in all pig cells. In this retrospective study, we assessed PERV infectivity in 28 patients treated with an extracorporeal bioartificial liver (HepatAssist system) that includes a membrane device containing porcine hepatocytes. All patients tested negative for PE...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06444.x

    authors: Pitkin Z,Mullon C

    更新日期:1999-09-01 00:00:00

  • Intravenous prostacyclin mitigates inhaled nitric oxide rebound effect: A case control study.

    abstract::Although extracorporeal membrane oxygenation (ECMO) improves oxygenation, pulmonary vascular resistance may be increased due to endothelial function impairment. Inhaled nitric oxide (iNO) is increasingly used for treatment of pulmonary hypertension after surgical repair of congenital heart defects, with or without ECM...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06448.x

    authors: Hermon M,Golej J,Burda G,Marx M,Trittenwein G,Pollak A

    更新日期:1999-11-01 00:00:00

  • High cell-density culture system of hepatocytes entrapped in a three-dimensional hollow fiber module with collagen gel.

    abstract::A compact three-dimensional (3D) module is needed for hepatocyte culture in order to develop an effective hybrid artificial liver system that can retain hepatocellular structure and differentiated functions. We treated the 3D module with collagen gel to entrap rat hepatocytes. This method yielded a high hepatocellular...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1995.tb02310.x

    authors: Takeshita K,Ishibashi H,Suzuki M,Yamamoto T,Akaike T,Kodama M

    更新日期:1995-02-01 00:00:00

  • LDL apheresis: a novel technique (LIPOCOLLECT 200).

    abstract::Therapeutic means to lower Lp(a) are limited. The most effective method to reduce plasma Lp(a) concentration significantly is therapeutic apheresis, namely, low-density lipoprotein (LDL) lipoprotein(a) (Lp(a)) apheresis. A novel technique based on reusable LDL adsorber called Lipocollect 200 (Medicollect, Rimbach, Ger...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00959.x

    authors: Stefanutti C,Di Giacomo S,Mazzarella B,Castelli A

    更新日期:2009-12-01 00:00:00

  • Visually guided performance of simple tasks using simulated prosthetic vision.

    abstract::Loss of photoreceptor cells is one of the major causes of blindness. Several groups are exploring the functional replacement of photoreceptors by a retinal prosthesis. The goal of this study was to simulate the vision levels that recipients of retinal prostheses with 4 x 4, 6 x 10, and 16 x 16 electrode arrays may exp...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2003.07309.x

    authors: Hayes JS,Yin VT,Piyathaisere D,Weiland JD,Humayun MS,Dagnelie G

    更新日期:2003-11-01 00:00:00

  • Long-term performance of homograft and autograft valves.

    abstract::Five hundred and eighty homograft valves have been inserted into the aortic position as isolated valve replacements, and followed up for 7--14 years. After ten years 90% of frozen homografts, 80% of autografts and 70% of freeze-dried homografts were free of valve-related death. There was only one embolism reported giv...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1980.tb03894.x

    authors: Bodnar E,Wain WH,Martelli V,Ross DN

    更新日期:1980-02-01 00:00:00

  • Initial experience with Impella RP in a quaternary transplant center.

    abstract::Right ventricular failure is one of the most common complications encountered after left ventricular assist device implantation and heart transplantation. It has been reported to have an incidence up to 30%. It increases morbidity and short-term mortality. Impella RP is a small pump that can provide up to 4L/min of fl...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13610

    authors: Monteagudo-Vela M,Simon A,Panoulas V

    更新日期:2020-05-01 00:00:00

  • Novel approach for designing a low weight hip implant used in total hip arthroplasty adopting skeletal design techniques.

    abstract::Aseptic loosening is the major cause of failure of hip implants after total hip arthroplasty. Stress shielding of the femur is known to be the principal factor involved in the aseptic loosening of hip implants. Solid stems are found to have a greater rigidity; therefore, they transfer less load proximally, which resul...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2010.01145.x

    authors: Sivarasu S,Beulah P,Mathew L

    更新日期:2011-06-01 00:00:00

  • Heparin-conjugated poly(lactic-co-glycolic acid) nanospheres enhance large-wound healing by delivering growth factors in platelet-rich plasma.

    abstract::Platelet-rich plasma (PRP) contains many growth factors that are involved in tissue regeneration processes. For successful tissue regeneration, protein growth factors require a delivery vehicle for long-term and sustained release to a defect site in order to maintain their bioactivity. Previously, we showed that hepar...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12389

    authors: La WG,Yang HS

    更新日期:2015-04-01 00:00:00

  • Experimental study on shear stress distributions in a centrifugal blood pump.

    abstract::Wall shear stress on the pump casing cover was measured using a surface-mounted hot-film sensor. In addition, the shear stress distribution in the pump was qualitatively investigated by means of oil-film visualization. The characteristics of shear stress in the pump are discussed, including the results on the oil-film...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2007.00421.x

    authors: Mizunuma H,Nakajima R

    更新日期:2007-07-01 00:00:00