Abstract:
:Wall shear stress on the pump casing cover was measured using a surface-mounted hot-film sensor. In addition, the shear stress distribution in the pump was qualitatively investigated by means of oil-film visualization. The characteristics of shear stress in the pump are discussed, including the results on the oil-film visualization. The centrifugal blood pump used was a Nikkiso HPM-15 (Nikkiso Co., Ltd, Tokyo, Japan). The hot-film measurement indicated that the shear stress was approximately proportional to the rotating speed, and exceeded 300 Pa when r/R > 0.5 at 3000 rpm. The circumferential average shear stress on the casing cover was of the same order as the characteristic stress sigma obtained from the pump axial torque. These results suggest that the shear stress on the casing cover can be used to evaluate the characteristic shear stress in the pump.
journal_name
Artif Organsjournal_title
Artificial organsauthors
Mizunuma H,Nakajima Rdoi
10.1111/j.1525-1594.2007.00421.xsubject
Has Abstractpub_date
2007-07-01 00:00:00pages
550-9issue
7eissn
0160-564Xissn
1525-1594pii
AOR421journal_volume
31pub_type
杂志文章abstract::The blood flow through the hemofilter device is the key point for ultrafiltrate production during continuous arteriovenous hemofiltration. It mainly depends on arteriovenous pressure gradient and vascular access, which is the major problem for arteriovenous hemofiltration in infants and small children. In infants, we ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1988.tb01518.x
更新日期:1988-02-01 00:00:00
abstract::The addition of human serum albumin (HSA) to peritoneal dialysate increases the clearance of bilirubin in rats suffering from obstructive jaundice. The acceptor properties of the fluid can be enhanced by using HSA that does not contain standard stabilizing additives and has been purified by further adsorption on activ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1993.tb00390.x
更新日期:1993-10-01 00:00:00
abstract::The accurate representation of rotary blood pumps in a numerical environment is important for meaningful investigation of pump-cardiovascular system interactions. Although numerous models for ventricular assist devices (VADs) have been developed, modeling methods for rotary total artificial hearts (rTAHs) are still re...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.12142
更新日期:2014-03-01 00:00:00
abstract::The vibrating flow pump (VFP) can generate high frequency oscillated blood flow. Because of the high frequency driving with short stroke volume, the pump system can be small. The disposable type VFP (D-VFP) was developed for use for extracorporeal circulation. The electromagnetic actuator was detached from the vibrati...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1997.tb03724.x
更新日期:1997-07-01 00:00:00
abstract::In transplantation surgery, extending the criteria for organ donation to include organs that may have otherwise been previously discarded has provided the impetus to improve organ preservation. The traditional method of cold static storage (CS) has been tried and tested and is suitable for organs meeting standard crit...
journal_title:Artificial organs
pub_type: 杂志文章,评审
doi:10.1111/aor.12865
更新日期:2017-09-01 00:00:00
abstract::Electrolyzed water accelerated the healing of full-thickness cutaneous wounds in rats, but only anode chamber water (acid pH or neutralized) was effective. Hypochlorous acid (HOCl), also produced by electrolysis, was ineffective, suggesting that these types of electrolyzed water enhance wound healing by a mechanism un...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.2000.06557-3.x
更新日期:2000-12-01 00:00:00
abstract::A physiological controller is a key component to optimize the performance of left ventricular assist devices (LVADs) from short term to long term (10-20 years). The difficulties of its design lie in the inaccurate modeling of any particular human cardiovascular system because of limited knowledge, the large fluctuatio...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2004.07381.x
更新日期:2004-10-01 00:00:00
abstract::The PI3K/Akt signaling pathway has been implicated in playing an important role in platelet activation during hemostasis and thrombosis involving platelet-matrix interaction and platelet aggregation. Its role in non-physiological shear stress (NPSS)-induced platelet activation relevant to high-shear blood contacting m...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.13465
更新日期:2019-09-01 00:00:00
abstract::A compact three-dimensional (3D) module is needed for hepatocyte culture in order to develop an effective hybrid artificial liver system that can retain hepatocellular structure and differentiated functions. We treated the 3D module with collagen gel to entrap rat hepatocytes. This method yielded a high hepatocellular...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1995.tb02310.x
更新日期:1995-02-01 00:00:00
abstract::There is increasing evidence showing that adult stem cells are useful for tissue regeneration. Bone marrow mesenchymal stem cells (MSCs) are self-renewing and are potent in differentiating into multiple cells and tissues. To investigate the practicability of repairing burn wounds with tissue-engineered (TE) skin combi...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2008.00654.x
更新日期:2008-12-01 00:00:00
abstract::Artificial oxygen (O2 ) carriers were reported to be protective in ischemia/reperfusion (I/R) in various organs including the heart. In the current study, 20 rats underwent ligation (MI) of the left anterior descending artery, were treated with 10 mL/kg of PEGylated carboxyhemoglobin bovine (SANGUINATE, S+, n = 10) or...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.13384
更新日期:2018-12-01 00:00:00
abstract::The combination of hypothermia and potassium cardioplegic arrest has become the most common method of myocardial protection in the evolution of myocardial protection. This review focuses on myocardial protection in pediatric cardiac surgery. In the 1980s, blood was added to cardioplegia solution in order to supply the...
journal_title:Artificial organs
pub_type: 杂志文章,评审
doi:10.1111/aor.12029
更新日期:2013-01-01 00:00:00
abstract::A beta2-microglobulin (beta2M) selective adsorbent (Lixelle) for direct hemoperfusion has been used for the treatment of hemodialysis patients with the long-term complication of dialysis related amyloidosis (DRA), but there is no significant correlation between the serum level of beta2M and the occurrence of DRA. Infl...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.1998.06179.x
更新日期:1998-12-01 00:00:00
abstract::A surgical method for the implantation of a mechanical right ventricular assist device which avoids resternotomy/thoracotomy and related complications at the time of explantation is presented. In order to support the failing right heart, a Dacron vascular graft was sewn to the pulmonary artery. For venous drainage, a ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2012.01520.x
更新日期:2012-08-01 00:00:00
abstract::It has been over 40 years since the initial clinical application of a cardiac pacemaker. Currently, approximately 300 per million patients in the United States and Europe are kept alive owing to the benefit of implantable pacemakers. Recently, the Japanese Cardiac Pacing Society and the Japanese Society of Artificial ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1994.tb03303.x
更新日期:1994-01-01 00:00:00
abstract::A 53-year-old man was referred to our department with a history of cough, especially at night, for 3 months. He was found to have a huge retrosternal goiter. We applied a novel combined cervical and robot-assisted approach to resect this difficult goiter. Using the da Vinci robot system, the intrathoracic part of the ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.12196
更新日期:2014-05-01 00:00:00
abstract::To develop a method for making percutaneous devices that have high biocompatibility and do not induce downgrowth of epidermal cells, we prepared a partial decellularized dermis (DD)/poly(methyl methacrylate) (PMMA) complex (PDPC) with a PMMA rod firmly stabilized inside. The porcine decellularized tissue was chosen be...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.12330
更新日期:2014-12-01 00:00:00
abstract::Progress in the techniques for surgical implantation of the artificial heart has progressed in parallel with the technology and design of the prosthesis. In the author's first experience with total artificial heart (TAH) implantation (1968) a trans-sternal split was used opening the sixth intercostal space on the righ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1977.tb00984.x
更新日期:1977-11-01 00:00:00
abstract::Eight patients were studied during four sessions of acetate-free biofiltration (AFBF). AFBF is a new dialysis technique with no base replacement agents in the dialysate and with the addition in postdilution mode of bicarbonate (HCO3) solution directly into the extracorporeal blood circuit. In this study the effects on...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1989.tb01561.x
更新日期:1989-10-01 00:00:00
abstract::To assess the efficiency of respiratory gas exchange in vitro through a dialysis membrane mounted inside a flat plate Kiil dialyzer, the model reactions of hydrogen peroxide reduction by a metal ion and of the carbon dioxide precipitation in the form of a carbonate in the dialysate were used. A comparison of the rates...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1983.tb04189.x
更新日期:1983-05-01 00:00:00
abstract::Effect of hemodialysis (HD) on some indices of immune response was studied in nine chronic uremics. Total lymphocyte, OKT4+, and OKT8+ cell numbers significantly decreased during the first 20 min of HD, and they were decreased till the third hour of the procedure, whereas the OKT4+/OKT8+ cell number ratio did not chan...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1989.tb02861.x
更新日期:1989-06-01 00:00:00
abstract::Widespread use of heart transplantation is limited by the scarcity of donor organs. Total artificial heart (TAH) development has been pursued to address this shortage, especially to treat patients who require biventricular support. We have developed a novel TAH that utilizes a continuously spinning rotor that shuttles...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.12959
更新日期:2017-10-01 00:00:00
abstract::The objective of this study was to evaluate the hemodynamic performance and gaseous microemboli (GME) handling ability of a simulated neonatal extracorporeal life support (ECLS) circuit with an in-line continuous renal replacement therapy (CRRT) device. The circuit consisted of a Maquet RotaFlow centrifugal pump or HL...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.12987
更新日期:2018-04-01 00:00:00
abstract::This study assessed the efficacy of multiarterial bypass in coronary artery bypass grafting (CABG) in dialysis patients. Eighty dialysis patients who underwent CABG were divided into 2 groups. Group A consisted of 38 patients in whom the left internal thoracic artery and additional saphenous vein graft (SVG) had been ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:
更新日期:2001-04-01 00:00:00
abstract::The aim of this study was to characterize and compare human great saphenous veins (HGSVs), HGSV cryoallografts, expanded polytetrafluoroethylene (ePTFE) segments, and elastic and muscular arteries' biomechanics, so as to identify if the biomechanical coupling and the HGSV advantages with respect to ePTFE depend on the...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2007.00467.x
更新日期:2007-11-01 00:00:00
abstract::The specific timing for discontinuing renal replacement therapy (RRT) in acute kidney injury (AKI) patients is debatable. The predictive abilities of variables at the time of discontinuation of RRT for the long-term prognoses of patients have not been explored. This study aimed to explore the prognostic factors upon d...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.12927
更新日期:2017-12-01 00:00:00
abstract::The maximum ventricular elastance is a reliable index for assessing the cardiac function from changes in its pressure-volume relationship. The advantage of this index is that it can represent the contractility of either unassisted hearts or native hearts assisted with rotary blood pumps. However, there are situations ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2009.00876.x
更新日期:2010-05-01 00:00:00
abstract::Percutaneous femoral venoarterial (VA) or jugular venovenous (VV) extracorporeal membrane oxygenation (ECMO) can result in delivery of hypoxic blood to the brain, coronaries, and upper extremities. Additionally, VA-ECMO by percutaneous femoral artery cannulation may compromise perfusion to the lower limbs. Use of near...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2012.01496.x
更新日期:2012-08-01 00:00:00
abstract::Continuous and intermittent high shear were loaded to red blood cells in a cone and a plate rheoscope. The mechanical damage to red cells was compared for continuous and intermittent shear. The intermittent shear was achieved by alternately starting and stopping shear repeatedly. In the case of intermittent shear load...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2007.00408.x
更新日期:2007-06-01 00:00:00
abstract::The aim of this study was to evaluate the safety and performance of the Arrow CorAide left ventricular assist system (LVAS) (Arrow International, Reading, PA, USA), a continuous-flow left ventricular assist device, as bridge to transplantation or recovery as well as destination therapy in patients with New York Heart ...
journal_title:Artificial organs
pub_type: 杂志文章,多中心研究,随机对照试验
doi:10.1111/j.1525-1594.2012.01539.x
更新日期:2013-02-01 00:00:00