Doppler ultrasonic detection of particulate release during hemodialysis with cellulose hollow-fiber and sorbent suspension reciprocating dialyzers.

Abstract:

:Doppler ultrasound is a noninvasive technique for monitoring moving objects such as flowing blood while ignoring stationary objects such as shunt tubing. A Doppler system was investigated to determine its sensitivity in detecting particulate release in blood during hemodialysis. Seven hemodialysis procedures with dogs and six trials with humans were done using a sorbent suspension reciprocating dialyzer ( SSRD ). Two additional trials were done with humans using a cellulose acetate hollow-fiber dialyzer (HFD). A large increase (approximately twofold) was found in the reflected Doppler signal in outflowing blood from the SSRD and HFD in both dogs and humans. Numerous additional studies to characterize the nature of the particulate matter showed platelet aggregates in the dogs and fibrinogen-fibrin degradation products in the humans to be present in the outflowing blood. In vitro studies suggested microscopic air bubbles (less than 25 micron in diameter) may have contributed to the particulate matter detected during hemodialysis by this sensitive monitoring system.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Badylak SF,Ash SR,Thornhill JA,Carr DJ

doi

10.1111/j.1525-1594.1984.tb04275.x

subject

Has Abstract

pub_date

1984-05-01 00:00:00

pages

220-3

issue

2

eissn

0160-564X

issn

1525-1594

journal_volume

8

pub_type

杂志文章
  • Ferritin: a reliable indicator of iron supplementation in patients on chronic hemodialysis/hemofiltration treatment?

    abstract::Four hundred and forty-two serum ferritin determinations were performed in 144 patients on chronic intermittent hemodialysis treatment with intravenous iron substitution and/or oral iron substitution. Iron substitution should be done individually according to regular serum ferritin determinations. Intravenous iron sub...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1981.tb03980.x

    authors: Müller HA,Schneider H,Hövelborn U,Streicher E

    更新日期:1981-05-01 00:00:00

  • Analysis of left ventricular impedance in comparison with ultrasound images.

    abstract::Cardiac monitoring of ventricular assist devices (VADs) is important for detecting heart failure risks, such as critical arrhythmia and ventricular fibrillation, and for supplying data that are useful for hemodynamic control. Specifically, impedance cardiograms (ICGs) are especially beneficial because they have no eff...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2011.01381.x

    authors: Choi SW,Park SM

    更新日期:2012-05-01 00:00:00

  • Electrical pulse train and single pulse stimulation of the small intestine: acute and chronic studies in the dog.

    abstract::In vitro tests have shown that electric currents may lead either to relaxation or contraction of the bowel wall. Because voluntary changes of the intestinal motility could be useful in the treatment of intestinal disorders, we investigated the reactions elicited by electrostimulation of the small intestine in the inta...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1989.tb02846.x

    authors: Moritz A,Grundfest-Broniatowski S,Ilyes L,Kasick J,Jacobs G,Olsen E,Nosé Y

    更新日期:1989-04-01 00:00:00

  • Electrotactile stimulator for artificial proprioception.

    abstract::With the goal of investigating artificial proprioception elicited by electrical stimulation, we have developed a tactile phi phenomenon-based stimulator. This two-channel microprocessed pulse amplitude modulation system generates two different envelope waveforms (triangular and elliptical) and allows programming and v...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1995.tb02318.x

    authors: Nohama P,Lopes AV,Cliquet Júnior A

    更新日期:1995-03-01 00:00:00

  • Use of tactile stiffness to detect fatigue in the latissimus dorsi muscle.

    abstract::In clinical settings, no method has been established to examine the fatigue of a latissimus dorsi muscle (LDM) preconditioned for cardiomyoplasty. We examined the feasibility of measuring muscle stiffness (tactile stiffness) to evaluate muscle fatigue in situ using our tactile sensor. We stimulated canine LDM with bur...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06551.x

    authors: Inaba H,Miyaji K,Kaneko Y,Ohtsuka T,Ezure M,Tambara K,Takamoto S,Omata S

    更新日期:2000-10-01 00:00:00

  • Artificial matrix helps neonatal cardiomyocytes restore injured myocardium in rats.

    abstract::The purpose of this study was to investigate whether an artificial matrix can help neonatal cardiomyocytes restore an injured heart in a rat model of myocardial infarction (MI). The left coronary arteries of female Sprague Dawley (SD) rats were ligated to create MI models. Ventricular cardiomyocytes from 1- to 3-day-o...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2006.00186.x

    authors: Zhang P,Zhang H,Wang H,Wei Y,Hu S

    更新日期:2006-02-01 00:00:00

  • A novel method to evaluate thromboresistance of drip chambers with filter used in extracorporeal blood circuits for hemodialysis.

    abstract::We have developed a novel method to simultaneously evaluate thromboresistance of two different types of drip chambers with a filter used in extracorporeal blood circuits for hemodialysis using canine arteriovenous shunt models. Bilateral bypasses between the femoral artery and vein on both sides of the animal were for...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb00354.x

    authors: Yamazaki M,Kobayashi K,Mori Y,Satoh T,Kubota S

    更新日期:1997-02-01 00:00:00

  • Cooling device for bradycardia based on Peltier element for accurate anastomosis of off-pump coronary artery bypass grafting.

    abstract::Upon introducing off-pump coronary artery bypass grafting (CABG), the indications for CABG were expanded to include patients who previously had no operative indications. For accurate anastomosis, various devices and methods have been developed. Bradycardia is easily induced by drug administration. However, this method...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2002.07087.x

    authors: Kuniyoshi Y,Koja K,Miyagi K,Shimoji M,Uezu T,Arakaki K,Yamashiro S,Mabuni K,Senaha S

    更新日期:2002-10-01 00:00:00

  • Cerebral and lower limb near-infrared spectroscopy in adults on extracorporeal membrane oxygenation.

    abstract::Percutaneous femoral venoarterial (VA) or jugular venovenous (VV) extracorporeal membrane oxygenation (ECMO) can result in delivery of hypoxic blood to the brain, coronaries, and upper extremities. Additionally, VA-ECMO by percutaneous femoral artery cannulation may compromise perfusion to the lower limbs. Use of near...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2012.01496.x

    authors: Wong JK,Smith TN,Pitcher HT,Hirose H,Cavarocchi NC

    更新日期:2012-08-01 00:00:00

  • Influence of hydration state on plasma volume changes during ultrafiltration.

    abstract::To assess the influence of hydration state on plasma volume (PV) changes during ultrafiltration, 11 clinically normhydrated patients on maintenance hemodialysis were studied intraindividually during 2 hydration states differing by 2-15% of lean body mass (LBM). Plasma volume was measured continually during a 15-min ul...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1995.tb02352.x

    authors: Wizemann V,Leibinger A,Mueller K,Nilson A

    更新日期:1995-05-01 00:00:00

  • Relation between echinocytosis and erythrocyte calcium content in hemodialyzed uremic patients.

    abstract::A rise in intracellular calcium concentration in erythrocytes has multiple effects on these cells. The purpose of this study was to determine the changes of calcium content in red blood cells (RBCs) and of echinocyte percentages in uremic patients during hemodialysis sessions. In 30 uremic patients under hemodialysis,...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2001.025006486.x

    authors: Agroyannis B,Kopelias I,Fourtounas C,Paraskevopoulos A,Tzanatos H,Dalamangas A,Mallas E

    更新日期:2001-06-01 00:00:00

  • Reciprocal influences between ambulatorial peritoneal dialysis and pulmonary function.

    abstract::The aim of this study was to verify if dialysis solution volumes used in patients on continuous ambulatory peritoneal dialysis (CAPD) interfere with pulmonary function and if the pulmonary volumes interfere with the lymphatic absorption of the peritoneal cavity. We submitted 10 CAPD patients with a mean age of 48 +/- ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2001.06904.x

    authors: Marmanillo CG,Pecoits-Filho RF,Romão JE Jr,Kakehashi ET,Sabbaga E,Marcondes M,Abensur H

    更新日期:2001-11-01 00:00:00

  • Anemia in acute renal failure: role for erythropoiesis-stimulating proteins?

    abstract::The use of recombinant human erythropoietin (rHuEpo) has revolutionized anemia management of early and late stages of chronic kidney disease. Darbopoietin is also now available for the treatment of anemia of chronic kidney disease. In addition, rHuEpo has been used for the treatment of anemia observed in critical illn...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1046/j.1525-1594.2003.07287.x

    authors: Liangos O,Pereira BJ,Jaber BL

    更新日期:2003-09-01 00:00:00

  • Microcirculation and artificial heart research.

    abstract::Small blood vessels may play a more important role in artificial heart (AH) recipients than ever suspected before. Observations of elevated total peripheral resistance, low hematocrit, reduced oncotic pressure, high circulating blood volume, and arterial pulsations with nonpulsatile devices require consideration of pe...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1988.tb01529.x

    authors: Lübbe AS

    更新日期:1988-02-01 00:00:00

  • In Vitro Evaluation of Pediatric Hollow-Fiber Membrane Oxygenators on Hemodynamic Performance and Gaseous Microemboli Handling: An International Multicenter/Multidisciplinary Approach.

    abstract::The objective of this study was to compare the hemodynamic performances and gaseous microemboli (GME) handling ability of two pediatric oxygenators in a simulated pediatric cardiopulmonary bypass (CPB) model and the importance of adding an arterial filter in the circuit. The circuit consisted of a Braile Infant oxygen...

    journal_title:Artificial organs

    pub_type: 杂志文章,多中心研究

    doi:10.1111/aor.12912

    authors: Wang S,Caneo LF,Jatene MB,Jatene FB,Cestari IA,Kunselman AR,Ündar A

    更新日期:2017-09-01 00:00:00

  • Is low-intensity anticoagulant therapy possible with an open pivot valve?: analysis of its development.

    abstract::In 1976, the authors became the codevelopers of the first successful bileaflet heart valve which has become the standard in valvular surgery. However, there still remains a significant rate of thromboembolism and thrombosis which can be attributed to the inherent design of cavities in the pivot area. These cavities co...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2002.06999.x

    authors: Nicoloff DM,Friedberg HD,Villafaña MA

    更新日期:2002-05-01 00:00:00

  • Reversal of experimental posthepatectomy liver failure in pigs: a new application of hepatocyte bioreactors.

    abstract::Postoperative liver failure remains a major cause of morbidity and mortality after extensive hepatectomies. This study aims to evaluate the effectiveness of a hepatocyte bioreactor in the treatment of experimental post-hepatectomy liver failure. Our experimental model included a combination of a side-to-side portacava...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2010.01016.x

    authors: Arkadopoulos N,Kostopanagiotou G,Nastos C,Papalois A,Papoutsidakis N,Kalimeris K,Defterevos G,Kanna T,Polyzois K,Kampouroglou G,Kypriotis D,Costopanagiotou C,Pafiti A,Tzanatos H,Smyrniotis V

    更新日期:2011-01-01 00:00:00

  • Dialyzer membranes: effect of surface area and chemical modification of cellulose on complement and platelet activation.

    abstract::Using an ex vivo model, the effects of membrane composition and surface area on both the complement system (as reflected by plasma C3a levels) and platelets [as indicated by plasma concentrations of thromboxane B2 (TXB2) and platelet factor 4 (PF4)] were studied. In this model, polyacrylonitrile (PAN) was associated w...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1987.tb02648.x

    authors: Mahiout A,Meinhold H,Kessel M,Schulze H,Baurmeister U

    更新日期:1987-04-01 00:00:00

  • Heparin-conjugated poly(lactic-co-glycolic acid) nanospheres enhance large-wound healing by delivering growth factors in platelet-rich plasma.

    abstract::Platelet-rich plasma (PRP) contains many growth factors that are involved in tissue regeneration processes. For successful tissue regeneration, protein growth factors require a delivery vehicle for long-term and sustained release to a defect site in order to maintain their bioactivity. Previously, we showed that hepar...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12389

    authors: La WG,Yang HS

    更新日期:2015-04-01 00:00:00

  • Influence of different heparin concentrations on the results of in vitro investigations in plasmaseparation technology using capillary membrane filters.

    abstract::Capillary membrane filters are devices commonly used for plasmapheresis and recirculating detoxification systems, including plasmaseparation units. Besides clinical trials and case reports, research on plasmafiltration techniques is carried out using in vitro systems. Notably, such hemoperfused in vitro systems requir...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2003.07132.x

    authors: Unger JK,Haltern C,Dohmen B,Rossaint R

    更新日期:2003-07-01 00:00:00

  • Restoration of muscle volume and shape induced by electrical stimulation of denervated degenerated muscles: qualitative and quantitative measurement of changes in rectus femoris using computer tomography and image segmentation.

    abstract::This study demonstrates in a novel way how volume and shape are restored to denervated degenerated muscles due to a special pattern of electrical stimulation. To this purpose, Spiral Computer Tomography (CT) and special image processing tools were used to develop a method to isolate the rectus femoris from other muscl...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00610.x

    authors: Gargiulo P,Vatnsdal B,Ingvarsson P,Knútsdóttir S,Gudmundsdóttir V,Yngvason S,Helgason T

    更新日期:2008-08-01 00:00:00

  • Effects of scaling on centrifugal blood pumps.

    abstract::Experimental studies on the effects of scaling on the performance of centrifugal blood pumps were conducted in a closed-loop test rig. For the prototype, eight different impellers of the same outer diameter of 25 mm were tested at 1,500, 2,000, and 2,500 revolutions per minute (rpm) using blood analog as fluid medium....

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2002.07119.x

    authors: Wong YW,Chan WK,Yu SC,Chua LP

    更新日期:2002-11-01 00:00:00

  • HeartWare Ventricular Assist Device Implantation for Pediatric Heart Failure-A Single Center Approach.

    abstract::While pediatric HeartWare HVAD application has increased, determining candidacy and timing for initiation of pediatric VAD support has remained a challenge. We present our experience with a systematic approach to HVAD implantation as a bridge to pediatric heart transplantation. We performed a retrospective, single cen...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13344

    authors: Nelson McMillan K,Hibino N,Brown EE,Wadia R,Hunt EA,Marshall C,Alvarez-Machado M,Alejo D,Coulson JD,Ravekes W,Vricella LA

    更新日期:2019-01-01 00:00:00

  • Fluctuations of the hemodynamic derivatives during left ventricular assistance using oscillated blood flow.

    abstract::To analyze the autonomic nervous system during left heart bypass with a vibrating flow pump (VFP), fluctuations in hemodynamic derivatives were evaluated by the spectral analysis method using fast fourier transform methodology. After the left pleural cavity was opened through the fourth intercostal space under general...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors: Yambe T,Kobayashi S,Nanka S,Naganuma S,Nitta S,Matsuki H,Abe K,Yoshizawa M,Fukuju T,Tabayashi K,Takeda H,Hashimoto H

    更新日期:1996-06-01 00:00:00

  • Double filtration plasmapheresis for the treatment of rheumatoid arthritis: a study of 21 cases.

    abstract::The treatment of rheumatoid arthritis remains difficult and often controversial. Plasma exchange has been advocated in some cases. In the present study 71 sessions of double filtration plasmapheresis (DFPP) were performed in 21 patients with rheumatoid arthritis in an average of 3.7 +/- 1.1 sessions per patient within...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb00344.x

    authors: Liu JD,Zhang C,Li WS,Lun LD

    更新日期:1997-02-01 00:00:00

  • Usability and safety of ventricular assist devices: human factors and design aspects.

    abstract::The purpose of this study was the investigation of the usability and ergonomics of ventricular assist devices (VADs) in everyday usage. Patients with four different VAD types were observed. After implantation, instruction, and discharge from the hospital, the patients returned on a regular basis to the outpatient clin...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00844.x

    authors: Geidl L,Zrunek P,Deckert Z,Zimpfer D,Sandner S,Wieselthaler G,Schima H

    更新日期:2009-09-01 00:00:00

  • Hemolysis and heat generation in six different types of centrifugal blood pumps.

    abstract::What the most causative factor affecting hemolysis is still controversial. To resolve this problem, we investigated the relationship between hemolysis and heat generation in six types of centrifugal blood pumps (Bio-Pump, Delphin, Capiox, Nikkiso, Isoflow, and Toyobo). The analyzed parameters were index of hemolysis i...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1995.tb02453.x

    authors: Araki K,Taenaka Y,Masuzawa T,Tatsumi E,Wakisaka Y,Watari M,Nakatani T,Akagi H,Baba Y,Anai H

    更新日期:1995-09-01 00:00:00

  • Prediction of postdialysis serum sodium concentration and transcellular fluid shift without measuring body fluid volumes.

    abstract::The postdialysis levels of serum sodium concentration, urea concentration, and osmolality, as well as the magnitude of both transcellular fluid shifts and sodium removal, were predicted based on computer modeling without measuring body fluid volumes. A 4-h hemodialysis was performed in five patients at a constant ultr...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1983.tb04219.x

    authors: Kimura G,Van Stone JC,Bauer JH

    更新日期:1983-11-01 00:00:00

  • Experimental study on shear stress distributions in a centrifugal blood pump.

    abstract::Wall shear stress on the pump casing cover was measured using a surface-mounted hot-film sensor. In addition, the shear stress distribution in the pump was qualitatively investigated by means of oil-film visualization. The characteristics of shear stress in the pump are discussed, including the results on the oil-film...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2007.00421.x

    authors: Mizunuma H,Nakajima R

    更新日期:2007-07-01 00:00:00

  • Baroreflex sensitivity of an arterial wall during rotary blood pump assistance.

    abstract::It is well known that the baroreflex system is one of the most important indicators of the pathophysiology in hypertensive patients. We can check the sensitivity of the baroreflex by observing heart rate (HR) responses; however, there is no simple diagnostic method to measure the arterial behavior in the baroreflex sy...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00864.x

    authors: Yambe T,Imachi K,Shiraishi Y,Yamaguchi T,Shibata M,Kameyama T,Yoshizawa M,Sugita N

    更新日期:2009-09-01 00:00:00