Artificial matrix helps neonatal cardiomyocytes restore injured myocardium in rats.

Abstract:

:The purpose of this study was to investigate whether an artificial matrix can help neonatal cardiomyocytes restore an injured heart in a rat model of myocardial infarction (MI). The left coronary arteries of female Sprague Dawley (SD) rats were ligated to create MI models. Ventricular cardiomyocytes from 1- to 3-day-old SD rats (both sexes) were isolated, cultured, and labeled. Three weeks after MI, the animals were randomized into four groups: (i) group cell plus matrix (n = 12); (ii) group cell (n = 12); (iii) group matrix (n = 12); and (iv) group control (n = 11). Four weeks after transplantation, echocardiography and the Langerdoff model were used to assess heart function. Immunohistochemical staining and polymerase chain reaction (PCR) were performed to track the implanted cardiomyocytes and detect the sex-determining region Y gene on the Y chromosome. Histology study and PCR showed that transplanted cardiomyocytes survived, formed condensed tissue, and produced connected protein in group cell plus matrix. Heart function assessment indicated transplantation of cardiomyocytes plus matrix preserved left ventricle wall thickness, fraction shortening, and end-systolic internal diameter most effectively.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Zhang P,Zhang H,Wang H,Wei Y,Hu S

doi

10.1111/j.1525-1594.2006.00186.x

subject

Has Abstract

pub_date

2006-02-01 00:00:00

pages

86-93

issue

2

eissn

0160-564X

issn

1525-1594

pii

AOR186

journal_volume

30

pub_type

杂志文章
  • Judicious usage of estrogen/progesterone for angiodysplasia.

    abstract::We recently experienced a case of a female hemodialysis patient with multiple intestinal angiodysplasias. In 2001, she complained of melena, and angiographic embolization halted bleeding from ileum angiodysplasia. In 2002, she again complained of black stool. Abdominal angiography found jejunum angiodysplasia, and pha...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2004.29003.x

    authors: Takenaka T,Kanno Y,Suzuki H

    更新日期:2005-01-01 00:00:00

  • Clinical evaluation of a new type of centrifugal pump.

    abstract::The major problems with existing centrifugal pumps are leakage, mechanical trauma, and thrombus formation. In consideration of these problems, a new compact centrifugal pump system was developed. The purpose of this study was to evaluate the new centrifugal pump system clinically. Ten patients underwent open heart sur...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1994.tb03403.x

    authors: Ninomiya J,Shoji T,Tanaka S,Ikeshita M,Ochi M,Yamauchi S,Yajima T,Yamauchi H,Sugimoto T,Aizawa T

    更新日期:1994-09-01 00:00:00

  • Physical testing of elastomers for cardiovascular applications.

    abstract::There are presently no short-term in vitro fatigue tests available that can predict long-term in vivo performance of elastomers in physiological environments. Thus, the introduction of new and better elastomers for cardiovascular applications is hampered in the development stage by lack of data about which materials s...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1983.tb04162.x

    authors: McMillin CR

    更新日期:1983-02-01 00:00:00

  • Multimodal flow visualization and optimization of pneumatic blood pump for sorbent hemodialysis system.

    abstract::Renal Solutions Allient Sorbent Hemodialysis System utilizes a two-chambered pneumatic pump (Pulsar Blood Pump, Renal Solutions, Inc., Warrendale, PA, USA) to avoid limitations associated with peristaltic pumping systems. Single-needle access is enabled by counter-pulsing the two pump chambers, thereby obviating compl...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00724.x

    authors: Shu F,Parks R,Maholtz J,Ash S,Antaki JF

    更新日期:2009-04-01 00:00:00

  • Relation between echinocytosis and erythrocyte calcium content in hemodialyzed uremic patients.

    abstract::A rise in intracellular calcium concentration in erythrocytes has multiple effects on these cells. The purpose of this study was to determine the changes of calcium content in red blood cells (RBCs) and of echinocyte percentages in uremic patients during hemodialysis sessions. In 30 uremic patients under hemodialysis,...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2001.025006486.x

    authors: Agroyannis B,Kopelias I,Fourtounas C,Paraskevopoulos A,Tzanatos H,Dalamangas A,Mallas E

    更新日期:2001-06-01 00:00:00

  • Control systems for the electric heart.

    abstract::Methods to predict and control cardiac output (CO) accurately in total artificial heart (TAH) recipients have varied significantly in the last few decades. Early models exhibited minimal control mechanisms and involved fixed pumping parameters. Elaborate electromechanical systems that have recently evolved require int...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors: White RK,Olsen DB

    更新日期:1991-10-01 00:00:00

  • Timing of Intra-Aortic Balloon Pump Placement Before Off-Pump Coronary Artery Bypass Grafting and Clinical Outcomes.

    abstract::We aimed to evaluate the timing of preoperative intra-aortic balloon pump (IABP) placement and outcomes in patients undergoing off-pump coronary artery bypass grafting (OPCAB). Patients with prophylactic IABP placement before OPCAB presenting between January 1, 2010 and December 31, 2013 were included. Patients were c...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13009

    authors: Liu F,Yang F,Du Z,Miao N,Zhao Y,Xu B,Hou X

    更新日期:2018-03-01 00:00:00

  • Visually guided performance of simple tasks using simulated prosthetic vision.

    abstract::Loss of photoreceptor cells is one of the major causes of blindness. Several groups are exploring the functional replacement of photoreceptors by a retinal prosthesis. The goal of this study was to simulate the vision levels that recipients of retinal prostheses with 4 x 4, 6 x 10, and 16 x 16 electrode arrays may exp...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2003.07309.x

    authors: Hayes JS,Yin VT,Piyathaisere D,Weiland JD,Humayun MS,Dagnelie G

    更新日期:2003-11-01 00:00:00

  • Hemolysis test of disposable type vibrating flow pump.

    abstract::The vibrating flow pump (VFP) can generate high frequency oscillated blood flow. Because of the high frequency driving with short stroke volume, the pump system can be small. The disposable type VFP (D-VFP) was developed for use for extracorporeal circulation. The electromagnetic actuator was detached from the vibrati...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb03724.x

    authors: Kobayashi S,Nitta S,Yambe T,Sonobe T,Naganuma S,Hashimoto H

    更新日期:1997-07-01 00:00:00

  • Acetate-free biofiltration: a viable alternative to bicarbonate dialysis.

    abstract::Eight patients were studied during four sessions of acetate-free biofiltration (AFBF). AFBF is a new dialysis technique with no base replacement agents in the dialysate and with the addition in postdilution mode of bicarbonate (HCO3) solution directly into the extracorporeal blood circuit. In this study the effects on...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1989.tb01561.x

    authors: Santoro A,Ferrari G,Spongano M,Badiali F,Zucchelli P

    更新日期:1989-10-01 00:00:00

  • Acellular Endocardium as a Novel Biomaterial for the Intima of Tissue-Engineered Small-Caliber Vascular Grafts.

    abstract::We aimed to investigate whether acellular endocardium can be used as a useful biomaterial for the intima of engineered small-caliber vascular grafts. Fresh endocardium was harvested from the swine left atrium and was decellularized by digestion with the decellularization solution of Triton X-100 and SDS containing DNa...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12814

    authors: Wang F,Guan X,Wu T,Qiao J,Han Z,Wu J,Yu X,You Q

    更新日期:2016-12-01 00:00:00

  • New versatile dual-support pediatric heart pump.

    abstract::Mechanical circulatory support (MCS) devices for pediatric patients continue to lag in development behind those for adults. There is no heart pump with the design innovation to support dysfunctional states of heart failure and the anatomic heterogeneity of cardiac defects in pediatric patients. To address this unmet n...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13507

    authors: Fox C,Sarkisyan H,Stevens R,Arabia F,Fischer W,Rossano J,Throckmorton A

    更新日期:2019-11-01 00:00:00

  • Delivery of the bioactive gas hydrogen sulfide during cold preservation of rat liver: effects on hepatic function in an ex vivo model.

    abstract::The insults sustained by transplanted livers (hepatectomy, hypothermic preservation, and normothermic reperfusion) could compromise hepatic function. Hydrogen sulfide (H₂S) is a physiologic gaseous signaling molecule, like nitric oxide (NO) and carbon monoxide (CO). We examined the effect of diallyl disulfide as a H₂S...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2011.01256.x

    authors: Balaban CL,Rodriguez JV,Guibert EE

    更新日期:2011-05-01 00:00:00

  • The effects of homologous cross-circulation and in situ liver perfusion on fulminant hepatic failure rats.

    abstract::A galactosamine-induced fulminant hepatic failure (FHF) rat model was used to study the effects of homologous cross-circulation and in situ liver perfusion. Cross-circulation with homologous donors did not significantly improve the survival time or recovery rate of grade II hepatic coma rats. Homologous in situ liver ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1980.tb03929.x

    authors: Mohsini K,Lister C,Chang TM

    更新日期:1980-08-01 00:00:00

  • Zero-balance ultrafiltration of the priming blood modifies the priming components and improves the clinical outcome in infants undergoing cardiopulmonary bypass: A randomized controlled trial.

    abstract::Cardiopulmonary bypass (CPB) requirement in infants presents a unique challenge because of the large prime volume-to-blood volume ratio. Packed red blood cells (PRBCs) tend to deteriorate with long-term storage owing to their unphysiological composition and osmolality. Given that blood priming is inevitable in neonate...

    journal_title:Artificial organs

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/aor.13559

    authors: Gholampour Dehaki M,Niknam S,Bakhshandeh H,Azarfarin R

    更新日期:2020-03-01 00:00:00

  • Hemolytic evaluation using polyurethane microcapsule suspensions in circulatory support devices: normalized index of hemolysis comparisons of commercial centrifugal blood pumps.

    abstract::We have been developing some types of microcapsule suspensions with polyurethane membranes to evaluate the absolute hemolytic characteristics of the centrifugal blood pumps used in circulatory support devices such as artificial hearts. In order to facilitate/realize hemolysis testing on centrifugal blood pumps that ha...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2007.00503.x

    authors: Maruyama O,Yamaguchi K,Nishida M,Onoguchi T,Tsutsui T,Jikuya T,Yamane T

    更新日期:2008-02-01 00:00:00

  • Adsorption of microorganism components by lixelle beads.

    abstract::We reported previously that Lixelle, which was used for beta-2 microglobulin (BMG) adsorption columns, could adsorb not only BMG but also inflammatory cytokines. We then were interested in the application of Lixelle to patients with systemic inflammatory response syndrome (SIRS) and tried to find out its ability to ad...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06502-2.x

    authors: Tsuchida K,Takemoto Y,Nakatani T,Nakamura T,Sugimura K,Yamamoto K

    更新日期:2000-07-01 00:00:00

  • Electrotactile stimulator for artificial proprioception.

    abstract::With the goal of investigating artificial proprioception elicited by electrical stimulation, we have developed a tactile phi phenomenon-based stimulator. This two-channel microprocessed pulse amplitude modulation system generates two different envelope waveforms (triangular and elliptical) and allows programming and v...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1995.tb02318.x

    authors: Nohama P,Lopes AV,Cliquet Júnior A

    更新日期:1995-03-01 00:00:00

  • The effect of electrode placement and interphase interval on force production during stimulation of the dorsiflexor muscles.

    abstract::The aims of this study were to investigate whether introducing an interphase interval (IPI) to biphasic pulses during stimulation of the dorsiflexor muscles would affect force production and to determine whether the IPI effect is dependent on electrode position. Twelve healthy volunteers participated in the study. Eac...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12346

    authors: Springer S,Braun-Benyamin O,Abraham-Shitreet C,Becher M,Laufer Y

    更新日期:2014-11-01 00:00:00

  • Ex vivo evaluation in normal dogs of insulin released by a bioartificial pancreas containing isolated rat islets of Langerhans.

    abstract::In bioartificial pancreatic systems, isolated islets of Langerhans are protected against immune rejection by an artificial membrane, permeable to glucose and insulin, but not to immunoglobulins and lymphocytes. Some of these devices, referred to as vascular systems, are set up to be connected to a vascular site in the...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1990.tb01588.x

    authors: Lepeintre J,Briandet H,Moussy F,Chicheportiche D,Darquy S,Rouchette J,Imbaud P,Duron JJ,Reach G

    更新日期:1990-02-01 00:00:00

  • Adverse events of subcutaneous recombinant human erythropoietin therapy: results of a controlled multicenter European study.

    abstract::In a controlled European multicenter study, clinical tolerance of subcutaneously administered recombinant human erythropoietin (rh-EPO) therapy and its influence on the course of illness in 362 hemodialyzed patients (162 males, 200 females) from 16 European dialysis centers was studied. Of these, 181 patients served a...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章,多中心研究,随机对照试验

    doi:10.1111/j.1525-1594.1993.tb00571.x

    authors: Klinkmann H,Wieczorek L,Scigalla P

    更新日期:1993-04-01 00:00:00

  • Evaluation of cardiac beat synchronization control for a rotary blood pump on valvular regurgitation with a mathematical model.

    abstract::We have studied the cardiac beat synchronization (CBS) control for a rotary blood pump (RBP) and revealed that it can promote pulsatility and reduce cardiac load. Besides, patients with LVAD support sometimes suffer from aortic and mitral regurgitation (AR and MR). A control method for the RBP should be validated in w...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13795

    authors: Ogawa D,Kobayashi S,Yamazaki K,Motomura T,Nishimura T,Shimamura J,Tsukiya T,Mizuno T,Takewa Y,Tatsumi E,Nishinaka T

    更新日期:2020-08-19 00:00:00

  • Immunologic studies of hollow-fiber dialyzer extracts.

    abstract::Testing failed to detect free isocyanates in dialyzer rinses or significant levels of immunoglobulin E antibodies to isocyanate-protein conjugates in the serum of individuals reacting during hemodialysis with dialyzers containing Cuprophan membranes. Extended immunization of rabbits with Limulus lysate-reactive materi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1984.tb04298.x

    authors: Butcher BT,Reed MA,O'Neil CE,Leech S,Pearson FC

    更新日期:1984-08-01 00:00:00

  • Effects of continuous-flow left ventricular assist devices on cerebral hemodynamics.

    abstract::Continuous-flow left ventricular assist devices (LVADs) reduce peak systolic flow, increase diastolic flow, and eliminate pulsatility of circulation. Altered blood flow may lead to a change in end-organ perfusion. Analysis of the flow dynamics of the arteries of end organs, such as the brain, may indicate whether an o...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13616

    authors: Karahan M,Kocabeyoglu SS,Kervan U,Sert DE,Aygun E,Tola M,Demirkan B,Mungan S,Kursun O,Catav Z,Pac M

    更新日期:2020-05-01 00:00:00

  • (13) C Breath Tests Are Feasible in Patients With Extracorporeal Membrane Oxygenation Devices.

    abstract::Temporary extracorporeal membrane oxygenation (ECMO) has been established as an essential part of therapy in patients with pulmonary or cardiac failure. As physiological gaseous exchange is artificially altered in this patient group, it is debatable whether a (13) C-breath test can be carried out. In this proof of tec...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12634

    authors: Bednarsch J,Menk M,Malinowski M,Weber-Carstens S,Pratschke J,Stockmann M

    更新日期:2016-07-01 00:00:00

  • Computational fluid dynamics prediction of blood damage in a centrifugal pump.

    abstract::This study explores a quantitative evaluation of blood damage that occurs in a continuous flow left ventricular assist device due to fluid stress. Computational fluid dynamics (CFD) analysis is used to track the shear stress history of 388 particle streaklines. The accumulation of shear and exposure time is integrated...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2003.00026.x

    authors: Song X,Throckmorton AL,Wood HG,Antaki JF,Olsen DB

    更新日期:2003-10-01 00:00:00

  • Bone marrow combined with dental bud cells promotes tooth regeneration in miniature pig model.

    abstract::Growth factors and morphogens secreted by bone marrow mesenchymal stem cells (BMSCs) of bone marrow fluid may promote tooth regeneration. Accordingly, a tissue engineering approach was utilized to develop an economical strategy for obtaining the growth factors and morphogens from BMSCs. Unerupted second molar tooth bu...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2010.01064.x

    authors: Kuo TF,Lin HC,Yang KC,Lin FH,Chen MH,Wu CC,Chang HH

    更新日期:2011-02-01 00:00:00

  • Selective removal of anti-acetylcholine receptor antibodies and IgG in vitro with an immunoadsorbent containing immobilized sulfathiazole.

    abstract::Adsorption therapy, which treats the autoimmune disease by the selective removal of pathogenic substances from the blood, is an active subject. In this therapy, bioactive molecules such as antigen, antibodies and protein A are usually used as affinity-ligands. The disadvantages of using these substances as affinity-li...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1990.tb02977.x

    authors: Yamamoto Y,Sameshima T,Akaike T

    更新日期:1990-10-01 00:00:00

  • Differential functional coupling between human saphenous cryoallografts and arteries: importance of the arterial type and the biomechanical parameter evaluated.

    abstract::The aim of this study was to characterize and compare human great saphenous veins (HGSVs), HGSV cryoallografts, expanded polytetrafluoroethylene (ePTFE) segments, and elastic and muscular arteries' biomechanics, so as to identify if the biomechanical coupling and the HGSV advantages with respect to ePTFE depend on the...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2007.00467.x

    authors: Bia D,Zócalo Y,Pessana F,Armentano R,Pérez H,Saldías M,Alvarez I

    更新日期:2007-11-01 00:00:00

  • Differentiation pattern of Vero cells cultured on poly(L-lactic acid)/poly(hydroxybutyrate-co-hydroxyvalerate) blends.

    abstract::This study evaluates the effect of poly(L-lactic acid) (PLLA) and poly(hydroxybutyrate-cohydroxyvalerate) (PHBV) bioabsorbable polymers and their blends on the induction of alteration of cell growth pattern in vitro. Vero cells were cultured on PLLA, PHBV, and different blends (100/0, 60/40, 50/50, 40/60, and 0/100). ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2004.47199.x

    authors: Santos AR Jr,Ferreira BM,Duek EA,Dolder H,Wada RS,Wada ML

    更新日期:2004-04-01 00:00:00