Abstract:
:Methods to predict and control cardiac output (CO) accurately in total artificial heart (TAH) recipients have varied significantly in the last few decades. Early models exhibited minimal control mechanisms and involved fixed pumping parameters. Elaborate electromechanical systems that have recently evolved require intricate communication between the circulating blood volume and the electric pump to maintain blood flow to critical organs. Attempts to quantitate specific end-organ blood flow, metabolic alterations, and oxygen delivery and, finally, to link these functions to the control of the TAH have not succeeded. Current devices seek to predict the needed CO by monitoring preload, afterload, or a combination of both. No consensus has developed concerning the appropriate physiologic parameters that should be surveyed in vivo and then used to regulate the output of the TAH.
journal_name
Artif Organsjournal_title
Artificial organsauthors
White RK,Olsen DBsubject
Has Abstractpub_date
1991-10-01 00:00:00pages
427-9issue
5eissn
0160-564Xissn
1525-1594journal_volume
15pub_type
杂志文章abstract::Dual chamber (DC) peritoneal dialysis (PD) dialysates contain fewer glucose degradation products (GDPs), so potentially reducing advanced glycosylation end products (AGEs), which have been reported to increase inflammation and cardiovascular risk. We wished to determine whether use of DC dialysates resulted in demonst...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.13768
更新日期:2020-07-09 00:00:00
abstract::For many years, it was thought that nonpulsatile perfusion produced physiological and circulatory abnormalities. Since 1977, Yukihiko Nosé and his colleagues have challenged this misconception. Toward that end, they did show that if a 20% higher blood flow uses more than that required for a pulsatile blood pump, then ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1996.tb04466.x
更新日期:1996-05-01 00:00:00
abstract::We report on 10 patients with acute renal involvement in Hantaan virus infection observed at the Department of Nephrology, Faculty of Medicine, Skopje, Republic of Macedonia, during a period of 3 years (October 1987-July 1990). Eight patients were male and 2 were female, aged 37.5 +/- 4.8 years. The diagnosis of Hanta...
journal_title:Artificial organs
pub_type: 临床试验,杂志文章
doi:10.1111/j.1525-1594.1995.tb02432.x
更新日期:1995-08-01 00:00:00
abstract::We have developed a novel method to simultaneously evaluate thromboresistance of two different types of drip chambers with a filter used in extracorporeal blood circuits for hemodialysis using canine arteriovenous shunt models. Bilateral bypasses between the femoral artery and vein on both sides of the animal were for...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1997.tb00354.x
更新日期:1997-02-01 00:00:00
abstract::In 1993, the development began of a small axial flow blood pump, the DeBakey ventricular assist device (VAD). The material was recently converted to a titanium alloy, and a waterproof pump package was incorporated for long-term intracorporeal circulation. Thirteen intrathoracic implantations in calves were achieved. N...
journal_title:Artificial organs
pub_type: 临床试验,杂志文章
doi:10.1046/j.1525-1594.1999.06300.x
更新日期:1999-12-01 00:00:00
abstract::Tissue engineering of cardiovascular structures represents a novel approach to improve clinical strategies in heart valve disease treatment. The aim of this study was to engineer decellularized atrioventricular heart valve neoscaffolds with an intact ultrastructure and to reseed them with umbilical cord-derived endoth...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.12321
更新日期:2014-07-01 00:00:00
abstract::In order to define physiological properties of the autograft root, magnetic resonance imaging (MRI) findings relative to three different operative techniques were compared with those of control subjects. Twenty-three patients, 18/5 M/F, aged 32 ± 9 years, underwent MRI assessment of the aortic root. Patients with norm...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2011.01202.x
更新日期:2011-12-01 00:00:00
abstract::We aimed to investigate whether acellular endocardium can be used as a useful biomaterial for the intima of engineered small-caliber vascular grafts. Fresh endocardium was harvested from the swine left atrium and was decellularized by digestion with the decellularization solution of Triton X-100 and SDS containing DNa...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.12814
更新日期:2016-12-01 00:00:00
abstract::In cardiac surgeries, it is frequently necessary to make the external blood circulation and oxygenation artificially. This procedure is called extracorporeal circulation (EC) or heart-lung bypass. During EC, one of the most important parameters, which demands continuous monitoring, is the blood flow. In many cases, th...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.2000.06532.x
更新日期:2000-03-01 00:00:00
abstract::Rheologic factors are likely to influence the balance between thrombotic and antithrombotic forces at the level of the vascular wall. In this study, the effects of flow-velocity/wall shear stress on the interaction of antithrombin (AT) with surface-immobilized heparin were investigated. The binding of AT to low-affini...
journal_title:Artificial organs
pub_type: 杂志文章
doi:
更新日期:1991-12-01 00:00:00
abstract::We have studied the cardiac beat synchronization (CBS) control for a rotary blood pump (RBP) and revealed that it can promote pulsatility and reduce cardiac load. Besides, patients with LVAD support sometimes suffer from aortic and mitral regurgitation (AR and MR). A control method for the RBP should be validated in w...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.13795
更新日期:2020-08-19 00:00:00
abstract::Solute clearance during high-flux hemodialysis is determined by the combined effects of solute convection and diffusion in the membrane, blood, and dialysate. Previous studies have focused almost entirely on the membrane transport phenomena, largely ignoring the potential contribution from bulk mass transport across t...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1993.tb00403.x
更新日期:1993-11-01 00:00:00
abstract::This article presents an image processing approach dedicated for a blind mobility aid facilitated through visual intracortical electrical stimulation. The method examines a display framework based on the distances related to a scene. The distances of objects to the walker are measured using a size perspective method w...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2011.01421.x
更新日期:2012-07-01 00:00:00
abstract::In this pilot study, we assessed the feasibility of using positron emission tomography (PET) imaging for in vivo measurement of skeletal muscle ventricle (SMV) tissue blood flow. In 4 dogs, with SMVs prepared from their latissimus dorsi muscle, we quantified SMV tissue blood flow by PET and related it to the tissue fl...
journal_title:Artificial organs
pub_type: 杂志文章
doi:
更新日期:2001-04-01 00:00:00
abstract::Centrifugal pumps have been used widely as the main pump in open heart surgery to reduce damage to blood elements and to reduce the activation of the coagulation system. The purpose of this study was the evaluation and comparison of the effects of two types of centrifugal pumps and of one type of roller pump on blood ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1996.tb04507.x
更新日期:1996-05-01 00:00:00
abstract::Chronic kidney disease is increasing in both developed and emerging countries with progressive encroachment on health services budgets. In spite of the lack of accurate registries, we tried to focus on the magnitude of the problem on different continents. Prevention of progression has been a remote but reachable goal....
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2006.00251.x
更新日期:2006-07-01 00:00:00
abstract::Liposome-encapsulated hemoglobin (LEH) was proven to be protective in cerebral ischemia/reperfusion injury. The present study evaluated LEH in a rat model of permanent middle cerebral artery (MCA) occlusion to clarify its effect during ischemia and reperfusion. Five minutes after thread occlusion of the MCA, rats were...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2008.00700.x
更新日期:2009-02-01 00:00:00
abstract::In this study, a series of natural biodegradable materials in the form of chitosan (C)-alginate (A)-hyaluronate (H) complexes are evaluated as tissue-engineering scaffolds. The weight ratio of C/A is 1 : 1 or 1 : 2. Sodium hyaluronate is mixed in 2%. The complexes can be cast into films or fabricated as scaffolds. The...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2004.00046.x
更新日期:2004-08-01 00:00:00
abstract:PURPOSE:We were led to the premise that with retrograde oxygenated blood perfusion, it would be possible to perform operations on the beating heart. METHODS:The experiment consisted of two stages: procedure 1 and 2. In procedure 1, six pigs were used. Retrograde perfusion flow was controlled to be in the range of 5.0-...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2004.47279.x
更新日期:2004-03-01 00:00:00
abstract::Continuous hemodiafiltration (CHDF) has been performed for the treatment of severe acute pancreatitis. Phospholipase A2 (PLA2) is one of the important mediators which exacerbate acute pancreatitis, but whether PLA2 can be removed by CHDF is unclear. In this study, the kinetics of group IB and group IIA PLA2 was examin...
journal_title:Artificial organs
pub_type: 临床试验,杂志文章
doi:10.1111/j.1525-1594.2007.00398.x
更新日期:2007-05-01 00:00:00
abstract::Present-day computational fluid dynamics (CFD) techniques can be used to analyze the behavior of fluid flow in a variety of pumps. CFD can be a powerful tool during the design stage for rapid virtual prototyping of different designs, analyzing performance parameters, and making design improvements. Computational flow ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:
更新日期:1996-06-01 00:00:00
abstract::Artificial oxygen (O2 ) carriers were reported to be protective in ischemia/reperfusion (I/R) in various organs including the heart. In the current study, 20 rats underwent ligation (MI) of the left anterior descending artery, were treated with 10 mL/kg of PEGylated carboxyhemoglobin bovine (SANGUINATE, S+, n = 10) or...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.13384
更新日期:2018-12-01 00:00:00
abstract::Excessive left ventricular (LV) volume unloading can affect right ventricular (RV) function by causing a leftward shift of the interventricular septum in patients with mitral regurgitation (MR) receiving left ventricular assist device (LVAD) support. Optimal settings for the LVAD should be chosen to appropriately cont...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.12702
更新日期:2016-11-01 00:00:00
abstract::Tissue-engineered heart valves constructed from a xenogeneic or allogeneic decellularized matrix might overcome the disadvantages of current heart valve substitutes. One major necessity besides effective decellularization is to preserve the biomechanical properties of the valve. Native and decellularized porcine pulmo...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2007.00452.x
更新日期:2008-01-01 00:00:00
abstract::Changing financial incentives have strongly influenced dosing patterns of recombinant human erythropoietin (rHuEPO) since its introduction in 1989. Although guidelines for prescribing rHuEPO exist, the extent to which they are adhered to is unknown. Using a retrospective cohort observational study design, the factors ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.2000.06495.x
更新日期:2000-02-01 00:00:00
abstract::The heparin-conjugated fibrin (HCF) system has been developed to deliver bone morphogenetic proteins (BMPs) for a long-term period and thus enhance bone regeneration. In the present study, we tested the effectiveness of the delivery system for spinal fusion with a very low dose of BMP-2. A total of 15 rabbits underwen...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2012.01578.x
更新日期:2013-05-01 00:00:00
abstract::We have been developing a new type of centrifugal pump for long-term use. The magnetically suspended centrifugal pump (MSCP) contains no shaft and seal so that long life expectancy is predicted. Paracorporeal left ventricular (LV) assist circulation between the left atrium and the descending aorta was instituted using...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1997.tb03713.x
更新日期:1997-07-01 00:00:00
abstract::The aim of this study is to compare the effect of a single diode laser application and agitation of EDTA with diode laser with different parameters at different time intervals on root fracture. Ninety mandibular incisors were instrumented except the negative control group. The specimens were divided randomly into 10 g...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.12608
更新日期:2016-06-01 00:00:00
abstract::Over the last 5 years, 12 patients received ventricular assist devices (VADs) while in postcardiotomy cardiogenic shock. There were 7 male and 5 female patients ranging in age from 22 to 73 years (average age, 54). Eight patients underwent surgery for valve replacements, 3 for coronary artery bypass graftings, and 1 f...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1993.tb00608.x
更新日期:1993-07-01 00:00:00
abstract::Cardiac monitoring of ventricular assist devices (VADs) is important for detecting heart failure risks, such as critical arrhythmia and ventricular fibrillation, and for supplying data that are useful for hemodynamic control. Specifically, impedance cardiograms (ICGs) are especially beneficial because they have no eff...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2011.01381.x
更新日期:2012-05-01 00:00:00