Influence of different heparin concentrations on the results of in vitro investigations in plasmaseparation technology using capillary membrane filters.

Abstract:

:Capillary membrane filters are devices commonly used for plasmapheresis and recirculating detoxification systems, including plasmaseparation units. Besides clinical trials and case reports, research on plasmafiltration techniques is carried out using in vitro systems. Notably, such hemoperfused in vitro systems require anticoagulation protocols suitable for investigating the clearance performance and hemocompatibility of a plasmafilter. This study analyzes how different heparin concentrations affect filtration performance and the hemocompatibility under conditions typically employed during in vitro experiments. Porcine blood from healthy slaughtered animals was used in an in vitro circuit. The blood collecting system was primed with heparin. Depending on the study group, blood was anticoagulated with either 2.5 IU/ml or 5 IU/ml heparin. The filters were n=10 PF1000N (effective membrane surface: 0.15 m2). For each experiment, the maximal permissible flow rate was established by determining the point where spontaneous hemolysis occurred and/or pressure values exceeded the highest limit of the pressure units on the apheresis monitor. Sieving coefficients of ten parameters, platelet counts, and coagulation patterns were determined at the lowest and highest blood flow (Qb) and filtration rates (Qf). Except for the activated clotting time (ACT), both anticoagulation protocols caused the blood to respond to its exposition to the plasmafilters concerning the activation and inhibition of the coagulation system. A significant decrease in platelet counts did not occur. There were sporadic differences in sieving properties between the groups. However, heparinization with 2.5 IU/ml resulted in unreproducible flow rate profiles, and pressure levels were higher than in the group with 5 IU/ml heparin. Compared to heparinization at 2.5 IU/ml, higher levels of heparinization stabilize rheological properties of the blood, and thereby increase the reliability of data obtained from plasmafiltration experiments carried out in vitro.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Unger JK,Haltern C,Dohmen B,Rossaint R

doi

10.1046/j.1525-1594.2003.07132.x

subject

Has Abstract

pub_date

2003-07-01 00:00:00

pages

649-57

issue

7

eissn

0160-564X

issn

1525-1594

pii

7132

journal_volume

27

pub_type

杂志文章
  • The compliance problem: a major obstacle in the development of implantable blood pumps.

    abstract::The compliance problem represents a major obstacle in the development of implantable blood pumps. The motor-driven pumps are enclosed in an airtight casing with gas in the motor space. The trapped gas in the motor space either increases the load on the motor during systole or impedes blood sac filling. Potential solut...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1984.tb04248.x

    authors: Lee S,Rosenberg G,Donachy JH,Wisman CB,Pierce WS

    更新日期:1984-02-01 00:00:00

  • An advanced mock circulation loop for in vitro cardiovascular device evaluation.

    abstract::Controlled and repeatable in vitro evaluation of cardiovascular devices using a mock circulation loop (MCL) is essential prior to in vivo or clinical trials. MCLs often consist of only a systemic circulation with no autoregulatory responses and limited validation. This study aimed to develop, and validate against huma...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13636

    authors: Gregory SD,Pauls JP,Wu EL,Stephens A,Steinseifer U,Tansley G,Fraser JF

    更新日期:2020-06-01 00:00:00

  • Treatment of severe hyperlipidemia: six years' experience with low-density lipoprotein apheresis.

    abstract::In total, 30 patients suffering from familial hypercholesterolemia, resistant to diet and lipid-lowering drugs, were treated for up to 6 years (3.6 + or - 1.6; range, 0.2-6.8 years) with low-density lipoprotein (LDL) apheresis. Three different systems were used; the dextran sulfate adsorption system (Kaneka) for 27 of...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1525-1594.1996.tb04455.x

    authors: Bambauer R,Schiel R,Latza R,Klinkmann J

    更新日期:1996-04-01 00:00:00

  • Relation between echinocytosis and erythrocyte calcium content in hemodialyzed uremic patients.

    abstract::A rise in intracellular calcium concentration in erythrocytes has multiple effects on these cells. The purpose of this study was to determine the changes of calcium content in red blood cells (RBCs) and of echinocyte percentages in uremic patients during hemodialysis sessions. In 30 uremic patients under hemodialysis,...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2001.025006486.x

    authors: Agroyannis B,Kopelias I,Fourtounas C,Paraskevopoulos A,Tzanatos H,Dalamangas A,Mallas E

    更新日期:2001-06-01 00:00:00

  • Computational fluid dynamics prediction of blood damage in a centrifugal pump.

    abstract::This study explores a quantitative evaluation of blood damage that occurs in a continuous flow left ventricular assist device due to fluid stress. Computational fluid dynamics (CFD) analysis is used to track the shear stress history of 388 particle streaklines. The accumulation of shear and exposure time is integrated...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2003.00026.x

    authors: Song X,Throckmorton AL,Wood HG,Antaki JF,Olsen DB

    更新日期:2003-10-01 00:00:00

  • Anionic collagen: polymer composites with improved dielectric and rheological properties.

    abstract::This work describes the preparation and characterization of anionic collagen composites with rhamsan and vinylidene fluoride-trifluorethylene with improved rheological and dielectric properties without loss of collagen secondary structure with an interaction occurring between both macromolecules of the composites. On ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.06109.x

    authors: Goissis G,Piccirili L,Goes JC,de Guzzi Plepis AM,Das-Gupta DK

    更新日期:1998-03-01 00:00:00

  • Minimally invasive access for central extracorporeal life support: how we do it.

    abstract::Central extracorporeal life support (ECLS) is an effective treatment method of cardiogenic shock patients with or without lung failure. However, complications like infection and bleeding are common. The classical implantation approach requires full sternotomy, mobilization of the heart, with the well-known risks of bl...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12344

    authors: Weymann A,Sabashnikov A,Patil NP,Mohite PN,Zych B,Garcia Saez D,Popov AF,Simon AR

    更新日期:2015-02-01 00:00:00

  • Antimicrobial Wound Dressing Containing Silver Sulfadiazine With High Biocompatibility: In Vitro Study.

    abstract::Many patients all over the world suffer from acute wounds caused by traumas or burns. In most crucial cases, skin regeneration cannot be promoted spontaneously, and skin grafts are applied as the main treatment. However, this therapy has some drawbacks which motivate researchers to develop wound dressings. In this stu...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12682

    authors: Mohseni M,Shamloo A,Aghababaei Z,Vossoughi M,Moravvej H

    更新日期:2016-08-01 00:00:00

  • Forward osmosis process for dialysis fluid regeneration.

    abstract::In a preliminary experiment, 38% of the spent dialysis fluid water was reclaimed by a forward osmosis process through a cellulose triacetate membrane. The simplicity of forward osmosis and its minimal external energy requirements may allow the construction of a small bulk device that can reclaim a considerable portion...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00816.x

    authors: Talaat KM

    更新日期:2009-12-01 00:00:00

  • Intermittent stops of shear reduce the mechanical damage of red blood cells.

    abstract::Continuous and intermittent high shear were loaded to red blood cells in a cone and a plate rheoscope. The mechanical damage to red cells was compared for continuous and intermittent shear. The intermittent shear was achieved by alternately starting and stopping shear repeatedly. In the case of intermittent shear load...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2007.00408.x

    authors: Mizunuma H,Sakai S

    更新日期:2007-06-01 00:00:00

  • Evaluation of perfusion modes on vital organ recovery and thyroid hormone homeostasis in pediatric patients undergoing cardiopulmonary bypass.

    abstract::The objectives of this study were: (i) to evaluate the effects of perfusion modes (pulsatile vs. nonpulsatile) on vital organs recovery and (ii) to investigate the influences of two different perfusion modes on the homeostasis of thyroid hormones in pediatric patients undergoing cardiopulmonary bypass (CPB) procedures...

    journal_title:Artificial organs

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/j.1525-1594.2010.01159.x

    authors: Akçevin A,Alkan-Bozkaya T,Qiu F,Undar A

    更新日期:2010-11-01 00:00:00

  • Design of a symmetry controller for cycling induced by electrical stimulation: preliminary results on post-acute stroke patients.

    abstract::This study deals with the design of a controller for cycling induced by functional electrical stimulation. The controller will be exploitable in the rehabilitation of hemiparetic patients who need to recover motor symmetry. It uses the pulse width as the control variable in the stimulation of the two legs in order to ...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1525-1594.2009.00941.x

    authors: Ambrosini E,Ferrante S,Schauer T,Ferrigno G,Molteni F,Pedrocchi A

    更新日期:2010-08-01 00:00:00

  • New immunosuppressive proteins (KX-2, -4, and -5) induced by liver transplantation.

    abstract::The presence in rat serum of three novel immunosuppressive proteins is associated with induction of tolerance after liver grafting. One of these, KX-5 (40 kilodalton molecular weight) is present 40-100 days after grafting of DA liver into PVG, a combination in which liver grafts are not rejected; two others, KX-2 (87 ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1996.tb00646.x

    authors: Kamada N

    更新日期:1996-10-01 00:00:00

  • Ex vivo evaluation in normal dogs of insulin released by a bioartificial pancreas containing isolated rat islets of Langerhans.

    abstract::In bioartificial pancreatic systems, isolated islets of Langerhans are protected against immune rejection by an artificial membrane, permeable to glucose and insulin, but not to immunoglobulins and lymphocytes. Some of these devices, referred to as vascular systems, are set up to be connected to a vascular site in the...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1990.tb01588.x

    authors: Lepeintre J,Briandet H,Moussy F,Chicheportiche D,Darquy S,Rouchette J,Imbaud P,Duron JJ,Reach G

    更新日期:1990-02-01 00:00:00

  • Testosterone and hemoglobin in hemodialysis male and female patients.

    abstract::It has been speculated that testosterone stimulates erythropoiesis. We hypothesized that hemoglobin levels in hemodialysis (HD) patients are associated with serum testosterone concentrations. Testosterone, hemoglobin, and other biochemical parameters were measured in a representative sample of 98 chronic HD patients (...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12218

    authors: Ekart R,Taskovska M,Hojs N,Bevc S,Hojs R

    更新日期:2014-07-01 00:00:00

  • Development of integrated electronics unit for drive and control of undulation pump-left ventricular assist device.

    abstract::In this study, we have developed an implantable electronics unit (IEU) for driving an undulation pump-left ventricular assist device (UP-LVAD). The IEU consists of a pump driver, three series-connected lithium ion batteries (1800 mAh), a charger, and a transcutaneous information transmission system. These electronic s...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2006.00233.x

    authors: Okamoto E,Makino T,Inoue Y,Tanaka S,Yasuda T,Nakamura M,Saito I,Abe Y,Chinzei T,Isoyama T,Mochiizuki S,Imachi K,Mitamura Y

    更新日期:2006-05-01 00:00:00

  • Asymptomatic atherosclerosis and hypertension in nondiabetic patients with chronic kidney disease.

    abstract::Atherosclerosis is accelerated in dialysis patients, but less is known about asymptomatic atherosclerosis and major risk factors in patients with different stages of chronic kidney disease (CKD). We compared intima media thickness (IMT) and plaque occurrence in the carotid arteries in 104 nondiabetic patients (stages ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2007.00522.x

    authors: Ekart R,Hojs R,Bevc S,Balon BP

    更新日期:2008-03-01 00:00:00

  • Timing of Intra-Aortic Balloon Pump Placement Before Off-Pump Coronary Artery Bypass Grafting and Clinical Outcomes.

    abstract::We aimed to evaluate the timing of preoperative intra-aortic balloon pump (IABP) placement and outcomes in patients undergoing off-pump coronary artery bypass grafting (OPCAB). Patients with prophylactic IABP placement before OPCAB presenting between January 1, 2010 and December 31, 2013 were included. Patients were c...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13009

    authors: Liu F,Yang F,Du Z,Miao N,Zhao Y,Xu B,Hou X

    更新日期:2018-03-01 00:00:00

  • Correlation between cerebral-renal near-infrared spectroscopy and ipsilateral renal perfusion parameters as clinical outcome predictors after open heart surgery in neonates and infants.

    abstract::The objective of this clinical study is to determine whether correlation exists among cerebral and renal near-infrared spectroscopy (NIRS) measurements, renal Doppler ultrasonography parameters (resistive index, peak systolic velocity), and early postoperative clinical outcomes following cardiac surgery in neonates an...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12455

    authors: Örmeci T,Alkan-Bozkaya T,Özyüksel A,Ersoy C,Ündar A,Akçevin A,Türkoğlu H

    更新日期:2015-01-01 00:00:00

  • Characteristics of chronically paced cardiac functions in the congenital complete atrioventricular block.

    abstract::Characteristics of morphology, cardiac function, and cardiac reserve at late state were evaluated at rest, by changing the pacing rates, and after exercise in patients with ventricular pacemakers for isolated congenital complete atrioventricular block. Heart size was reduced statistically after pacemaker implantation,...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1987.tb02667.x

    authors: Nawa S,Kioka Y,Shimizu A,Tsuji H,Miyachi Y,Ebara K,Kino K,Shigenobu M,Murakami T,Senoo Y

    更新日期:1987-06-01 00:00:00

  • Expression of inflammation in myocardial tissue of rabbits: comparison of two miniaturized heart-lung machines.

    abstract::The majority of cases involving the surgical treatment of congenital heart disease require implementation of cardiopulmonary bypass (CPB). However, neonates and infants are particularly prone to serious complications associated with CPB as a result of capillary leak due to cardiovascular failure. These complications a...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12025

    authors: Schnoering H,Arens J,Detering SM,Sachweh JS,Goetzenich A,Schmitz-Rode T,Steinseifer U,Vazquez-Jimenez JF

    更新日期:2013-06-01 00:00:00

  • Circulatory loop design and components introduce artifacts impacting in vitro evaluation of ventricular assist device thrombogenicity: A call for caution.

    abstract::Mechanical circulatory support (MCS) devices continue to be hampered by thrombotic adverse events (AEs), a consequence of device-imparted supraphysiologic shear stresses, leading to shear-mediated platelet activation (SMPA). In advancing MCS devices from design to clinical use, in vitro circulatory loops containing th...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13626

    authors: Li M,Walk R,Roka-Moiia Y,Sheriff J,Bluestein D,Barth EJ,Slepian MJ

    更新日期:2020-06-01 00:00:00

  • Renal effects of multiple infusion of pyridoxalated-hemoglobin-polyoxyethylene conjugate (PHP) solution in dogs.

    abstract::Pyridoxalated-hemoglobin-polyoxyethylene conjugate (PHP), which is made from out-dated human red blood cells by two major chemical modifications, namely pyridoxalation and conjugation with polyoxyethylene (POE), is currently under development as a physiological oxygen carrier. This study assessed the effects of PHP-88...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1993.tb00424.x

    authors: Takahashi T,Iwasaki K,Malchesky PS,Harasaki H,Matsushita M,Nosé Y,Rolin H 3rd,Hall PM

    更新日期:1993-03-01 00:00:00

  • Diabetes-induced alterations in latissimus dorsi muscle properties impair effectiveness of dynamic cardiomyoplasty in rats.

    abstract::Short-term diabetes was induced in male Wistar rats with streptozotocin injection. The effects of diabetes on latissimus dorsi (LD) muscle contractile and biochemical properties and acute cardiomyoplasty (CDM) were assessed and compared with data from 16 control rats. Isometric force, contractile properties, and fatig...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2004.47349.x

    authors: De Angelis K,Senna S,Irigoyen MC,Cestari IA

    更新日期:2004-04-01 00:00:00

  • A preliminary study of microcapsule suspension for hemolysis evaluation of artificial organs.

    abstract::A microcapsule suspension, a substitute for animal blood in hemolysis tests, has been developed for evaluation of the absolute hemolytic properties of circulatory artificial organs. The microcapsule suspension was made by dispersing microcapsule slurry into an ethylene glycol sodium chloride solution. The microcapsule...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06316.x

    authors: Maruyama O,Yamane T,Tsunemoto N,Nishida M,Tsutsui T,Jikuya T

    更新日期:1999-03-01 00:00:00

  • Superior mesenteric artery mycotic aneurysm in patients with left ventricular assist device support and intravenous drug abuse.

    abstract::Mycotic aneurysm of the superior mesenteric artery (SMA) is one of the complications associated with infective endocarditis. However, there are no previous case reports in the literature describing mycotic SMA aneurysm after left ventricular assist device (LVAD) implantation. We describe the case of a 31-year-old male...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2011.01250.x

    authors: Motomura T,Bruckner B,Leon-Becerril J,Anaya-Ayala JE,de Rienzo-Madero B,Bismuth J,Bunge R,Irwin S,Loebe M

    更新日期:2011-07-01 00:00:00

  • Treatment of thyrotoxic crisis with plasmapheresis and single pass albumin dialysis: a case report.

    abstract::Thyrotoxic crisis (thyroid storm) is a life-threatening condition. Standard therapy is based on thiamazole, prednisolone, and nonselective beta-blockers. Extracorporeal plasmapheresis is an additional tool for removing circulating thyroxine in patients who do not respond quickly to conventional standard therapy. As th...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00924.x

    authors: Koball S,Hickstein H,Gloger M,Hinz M,Henschel J,Stange J,Mitzner S

    更新日期:2010-02-01 00:00:00

  • The accurate control of ultrafiltration.

    abstract::An apparatus has been contructed to regulate ultrafiltration accurately during dialysis. The principle of the apparatus is that, per unit of time, exactly the same amount of dialysate is introduced into the dialyzer as is discharged from it. The apparatus consists of two isovolumetric pumps connected in line. The four...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1978.tb03442.x

    authors: Flendrig JG,Carpay WM,Dekkers WT

    更新日期:1978-05-01 00:00:00

  • Myristoyl gelatin as a sealant for Dacron vascular prostheses.

    abstract::Myristoyl gelatin (MG) retains its gel structure at temperatures above body temperature without any crosslinking. As a coating material, MG adheres well to polyester fibers, and the outermost layers of the sealant that are in contact with blood or surrounding tissue become hydrophilic. We produced MG-impregnated knitt...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb00363.x

    authors: Sasajima T,Inaba M,Azuma N,Goh K,Koshiko S,Kubo Y,Miyamoto K,Tokita M,Komai T

    更新日期:1997-04-01 00:00:00

  • Plasma exchange and immunoadsorption for removal of antibodies prior to ABO incompatible bone marrow transplant.

    abstract::ABO incompatible allogeneic bone marrow transplants can be performed successfully to treat patients with leukemia or aplastic anemia. These transplants carry no great risk of rejection or graft-versus-host disease, however, some method must be used to avoid acute hemolysis at the time of infusion of ABO incompatible m...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1981.tb03998.x

    authors: Bensinger WI

    更新日期:1981-08-01 00:00:00