Forward osmosis process for dialysis fluid regeneration.

Abstract:

:In a preliminary experiment, 38% of the spent dialysis fluid water was reclaimed by a forward osmosis process through a cellulose triacetate membrane. The simplicity of forward osmosis and its minimal external energy requirements may allow the construction of a small bulk device that can reclaim a considerable portion of the water used in the patient's dialysis process. For developing an acceptable ambulatory dialysis system, decreasing the bulk of the fluid and equipment carried on the patient is essential. Forward osmosis may feasibly be used for dialysis fluid regeneration in ambulatory dialysis systems.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Talaat KM

doi

10.1111/j.1525-1594.2009.00816.x

subject

Has Abstract

pub_date

2009-12-01 00:00:00

pages

1133-5

issue

12

eissn

0160-564X

issn

1525-1594

pii

AOR816

journal_volume

33

pub_type

杂志文章
  • Implantable volume monitor and miniaturized stimulator dedicated to bladder control.

    abstract::This paper describes a new miniaturized implantable bladder controller that is composed of 4 main parts: a volume monitoring device based on the tomography approach, a fully programmable miniaturized central processor and stimulator, a bidirectional data and power link, and an external controller. The proposed system ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors: Sawan M,Arabi K,Provost B

    更新日期:1997-03-01 00:00:00

  • Temporary right heart assist: a minimally invasive approach.

    abstract::A surgical method for the implantation of a mechanical right ventricular assist device which avoids resternotomy/thoracotomy and related complications at the time of explantation is presented. In order to support the failing right heart, a Dacron vascular graft was sewn to the pulmonary artery. For venous drainage, a ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2012.01520.x

    authors: Schopka S,Haneya A,Rupprecht L,Camboni D,Schmid C,Hilker M

    更新日期:2012-08-01 00:00:00

  • Low-intensity ultrasound stimulation enhances chondrogenic differentiation in alginate culture of mesenchymal stem cells.

    abstract::Mesenchymal stem cells (MSCs) are regarded as a potential autologous source for cartilage repair, because they can differentiate into chondrocytes by transforming growth factor-beta (TGF-beta) treatment under the 3-dimensional (3-D) culture condition. However, more efficient and versatile methods for chondrogenic diff...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2006.00288.x

    authors: Lee HJ,Choi BH,Min BH,Son YS,Park SR

    更新日期:2006-09-01 00:00:00

  • Modified DALI LDL-apheresis using trisodium citrate anticoagulation plus bicarbonate or lactate-buffered hemofiltration substitution fluids as primers.

    abstract:BACKGROUND:DALI (direct adsorption of lipids) is the first LDL-apheresis technique able to adsorb low-density lipoprotein (LDL) and lipoproteina) directly from whole blood. In the standard procedure, acid citrate dextrose (ACD-A) is used as anticoagulation and the adsorber is rinsed with a specially manufactured primin...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1046/j.1525-1594.2003.07104.x

    authors: Bosch T,Wendler T,Maschke H

    更新日期:2003-06-01 00:00:00

  • Cerebral and lower limb near-infrared spectroscopy in adults on extracorporeal membrane oxygenation.

    abstract::Percutaneous femoral venoarterial (VA) or jugular venovenous (VV) extracorporeal membrane oxygenation (ECMO) can result in delivery of hypoxic blood to the brain, coronaries, and upper extremities. Additionally, VA-ECMO by percutaneous femoral artery cannulation may compromise perfusion to the lower limbs. Use of near...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2012.01496.x

    authors: Wong JK,Smith TN,Pitcher HT,Hirose H,Cavarocchi NC

    更新日期:2012-08-01 00:00:00

  • Hemolysis test of a centrifugal pump in a pulsatile mode: the effect of pulse rate and RPM variance.

    abstract::Centrifugal pumps are generally employed as nonpulsatile blood flow pumps; however, these pumps can produce pulsatile flow by periodically alternating the impeller rotation speed. This study investigates blood trauma due to the effect of pulse frequency and various ranges of pump speed. The hemolysis tests were conduc...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb00489.x

    authors: Tayama E,Niimi Y,Takami Y,Ohashi Y,Ohtsuka G,Glueck JA,Mueller J,Nosé Y

    更新日期:1997-12-01 00:00:00

  • Double catheterization of the internal jugular vein for hemodialysis: indications, techniques, and clinical results.

    abstract::Central vascular catheters are used to access the central vascular system in both acute and chronic uremic patients undergoing hemodialysis. Among different approaches, the internal jugular vein seems to have less adverse effects. We describe our long-term experience with a two-catheter system. Percutaneous jugular ve...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1994.tb02200.x

    authors: Tesio F,De Baz H,Panarello G,Calianno G,Quaia P,Raimondi A,Schinella D

    更新日期:1994-04-01 00:00:00

  • Stem damage during implantation of modular hip prostheses.

    abstract::Modular hip prostheses are commonly used today. Dedicated surgical auxiliary instrumentation is indispensable. A correct coupling between the prosthesis and the instrument is necessary to avoid damage. Based on a specific commercial design (AnCAFit, Wright Cremascoli Ortho, Toulon, France), the aim of this work was to...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2006.00261.x

    authors: Varini E,Cristofolini L,Viceconti M,Traina F

    更新日期:2006-07-01 00:00:00

  • Biological evaluation of liposome-encapsulated hemoglobin surface-modified with a novel PEGylated nonphospholipid amphiphile.

    abstract::Traumatic injury is often associated with hemorrhagic shock. Liposome-encapsulated hemoglobin (LEH) is being developed as an artificial oxygen carrier to address post-hemorrhage oxygen and volume deficit. Here, we report a new composition of LEH based on the use of polyethylene glycol (PEG2K ) conjugated with nonphosp...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12304

    authors: Yadav VR,Nag O,Awasthi V

    更新日期:2014-08-01 00:00:00

  • Effects of continuous-flow left ventricular assist devices on cerebral hemodynamics.

    abstract::Continuous-flow left ventricular assist devices (LVADs) reduce peak systolic flow, increase diastolic flow, and eliminate pulsatility of circulation. Altered blood flow may lead to a change in end-organ perfusion. Analysis of the flow dynamics of the arteries of end organs, such as the brain, may indicate whether an o...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13616

    authors: Karahan M,Kocabeyoglu SS,Kervan U,Sert DE,Aygun E,Tola M,Demirkan B,Mungan S,Kursun O,Catav Z,Pac M

    更新日期:2020-05-01 00:00:00

  • Magnevad status of design improvements human blood results and preliminary sheep trial.

    abstract::Magnevad II is an improved version of Magnevad I and both are fourth-generation axial flow left ventricular assist devices. A major simplification has been implemented and tested. Magnevad I used a magnetically suspended rotor requiring active axial control. Magnevad II is completely passive but otherwise similar. A s...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2005.29113.x

    authors: Goldowsky M,Lafaro R,Reed G

    更新日期:2005-10-01 00:00:00

  • How to comply with the Food and Drug Administration's "Investigational Device Exemption (IDE)" regulations including an application form (revised January 1982).

    abstract::This is a revision of the IDE Application Form, "How to Comply with the Food and Drug Administration's New 'Investigational Device Exemption (IDE)' Regulations, Including an Application Form" originally published in Artificial Organs, Volume 4, Number 4, November 1980. This publication updates the IDE application form...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors:

    更新日期:1982-02-01 00:00:00

  • Development of a composite degradable/nondegradable tissue-engineered vascular graft.

    abstract::The present study aimed to determine the feasibility of constructing a reinforced autologous vascular graft by combining the advantages of fibrin gel as an autologous cell carrier material with the inherent mechanical strength of an integrated mesh structure. It was hypothesized that the mesh and dynamic culture condi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00601.x

    authors: Tschoeke B,Flanagan TC,Cornelissen A,Koch S,Roehl A,Sriharwoko M,Sachweh JS,Gries T,Schmitz-Rode T,Jockenhoevel S

    更新日期:2008-10-01 00:00:00

  • Comparison of four methods of cleaning hollow-fiber dialyzers for reuse.

    abstract::Four methods of cleaning hollow-fiber artificial kidneys (HFAKs) for reuse were compared in a prospective study. Each cleaning method was randomly assigned and HFAKs were reused until volume loss was greater than or equal to 15 ml, unless discarded for other reasons. HFAKs cleaned with 0.3 M sodium hydroxide averaged ...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1111/j.1525-1594.1986.tb02602.x

    authors: Dennis MB Jr,Vizzo JE,Cole JJ,Westendorf DL,Ahmad S

    更新日期:1986-12-01 00:00:00

  • Hemodynamic Evaluation of a Biological and Mechanical Aortic Valve Prosthesis Using Patient-Specific MRI-Based CFD.

    abstract::Modeling different treatment options before a procedure is performed is a promising approach for surgical decision making and patient care in heart valve disease. This study investigated the hemodynamic impact of different prostheses through patient-specific MRI-based CFD simulations. Ten time-resolved MRI data sets w...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12955

    authors: Hellmeier F,Nordmeyer S,Yevtushenko P,Bruening J,Berger F,Kuehne T,Goubergrits L,Kelm M

    更新日期:2018-01-01 00:00:00

  • Effect of Continuous-Flow Mechanical Circulatory Support on Microvasculature Remodeling in the Failing Heart.

    abstract::Left ventricle (LV) unloading caused by a left ventricular assist device (LVAD) has been shown to enhance reverse LV remodeling in end-stage cardiomyopathy. Several reports consistently suggest that a pulsatile-flow LVAD has more profound effects compared to continuous-flow LVAD, though the responsible mechanisms are ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13348

    authors: Saito T,Miyagawa S,Toda K,Yoshikawa Y,Fukushima S,Saito S,Yoshioka D,Sakata Y,Daimon T,Sawa Y

    更新日期:2019-04-01 00:00:00

  • Rotary blood pump flow spontaneously increases during exercise under constant pump speed: results of a chronic study.

    abstract::Many types of rotary blood pumps and pump control methods have recently been developed with the goal of clinical use. From experiments, we know that pump flow spontaneously increases during exercise without changing pump control parameters. The purpose of this study was to determine the hemodynamics associated with th...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06426.x

    authors: Akimoto T,Yamazaki K,Litwak P,Litwak KN,Tagusari O,Mori T,Antaki JF,Kameneva MV,Watach MJ,Umezu M,Tomioka J,Kormos RL,Koyanagi H,Griffith BP

    更新日期:1999-08-01 00:00:00

  • Effects of hemodynamic conditions and valve sizing on leaflet bending stress in self-expanding transcatheter aortic valve: An in vitro study.

    abstract::Transcatheter aortic valve (TAV) replacement has become a viable alternative to surgery for high and intermediate risk patients with severe aortic stenosis. This technology may extend to the younger and lower risk patients. In this population, long-term durability of the TAV is key. Increased leaflet mechanical stress...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13654

    authors: Stanová V,Zenses AS,Thollon L,Kadem L,Barragan P,Rieu R,Pibarot P

    更新日期:2020-07-01 00:00:00

  • Apheresis technologies: an international perspective.

    abstract::The developments in apheresis techniques and their clinical applications world-wide are technologically driven. In the past, apheresis survey statistics have high-lighted both the differences by region in clinical practice and in the types of technologies utilized. Such differences have provided a basis for the scient...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1995.tb02334.x

    authors: Malchesky PS,Bambauer R,Horiuchi T,Kaplan A,Sakurada Y,Samuelsson G

    更新日期:1995-04-01 00:00:00

  • Numerical modeling of blood flow in the ventricular cavity of the artificial heart.

    abstract::The flow of blood as a viscous, Newtonian, incompressible liquid in an expanding spherical cavity with a ball-type inlet valve was examined. This type of flow can serve as a model of the phase of ventricular diastole in a sac-type artificial heart. The critical values of Reynolds numbers at which flow interruption beh...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1983.tb04170.x

    authors: Starobin IM,Zaĭko VM

    更新日期:1983-02-01 00:00:00

  • Intermittent stops of shear reduce the mechanical damage of red blood cells.

    abstract::Continuous and intermittent high shear were loaded to red blood cells in a cone and a plate rheoscope. The mechanical damage to red cells was compared for continuous and intermittent shear. The intermittent shear was achieved by alternately starting and stopping shear repeatedly. In the case of intermittent shear load...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2007.00408.x

    authors: Mizunuma H,Sakai S

    更新日期:2007-06-01 00:00:00

  • Heart valve inspired and multi-stream aortic cannula: Novel designs for cardiopulmonary bypass improvement in neonates.

    abstract::In a typical open-heart surgery, the blood flow through the aortic cannula is a critical element of the cardiopulmonary bypass (CPB) procedure. Especially for the neonatal and pediatric CPB flow conditions, the need for small hydraulic diameter and large blood flow results confined turbulent jet flow regimes that exac...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13462

    authors: Rasooli R,Pekkan K

    更新日期:2019-10-01 00:00:00

  • The status of pacemaker implantations in Japan.

    abstract::It has been over 40 years since the initial clinical application of a cardiac pacemaker. Currently, approximately 300 per million patients in the United States and Europe are kept alive owing to the benefit of implantable pacemakers. Recently, the Japanese Cardiac Pacing Society and the Japanese Society of Artificial ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1994.tb03303.x

    authors: Kojima R

    更新日期:1994-01-01 00:00:00

  • The SlideReactor--a simple hollow fiber based bioreactor suitable for light microscopy.

    abstract::Most bioartificial liver support systems are based on hollow fiber capillaries within modified dialysis cartridges or more sophisticated bioreactor constructions. Due to their design microscopic follow-up of reorganization and growth of tissue between the hollow fibers is not possible. The SlideReactor is a simple hol...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2005.29049.x

    authors: Sauer IM,Schwartlander R,Schmid J,Efimova E,Vondran FW,Kehr D,Pless G,Spinelli A,Brandenburg B,Hildt E,Neuhaus P

    更新日期:2005-03-01 00:00:00

  • A computerized model to analyze transcellular fluid shift during hemofiltration.

    abstract::Using urea and inulin as markers, we have developed a simple method to calculate intracellular and extracellular fluid volume in patients before and after hemofiltration therapy. During conventional hemofiltration using substitution fluid with a Na+ concentration of 140 mEq/L, a decrease in extracellular fluid volume ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1982.tb04054.x

    authors: Kimura G,Satani M,Kojima S,Kuroda K,Itoh K,Ikeda M

    更新日期:1982-02-01 00:00:00

  • Treatment of severe hyperlipidemia: six years' experience with low-density lipoprotein apheresis.

    abstract::In total, 30 patients suffering from familial hypercholesterolemia, resistant to diet and lipid-lowering drugs, were treated for up to 6 years (3.6 + or - 1.6; range, 0.2-6.8 years) with low-density lipoprotein (LDL) apheresis. Three different systems were used; the dextran sulfate adsorption system (Kaneka) for 27 of...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1525-1594.1996.tb04455.x

    authors: Bambauer R,Schiel R,Latza R,Klinkmann J

    更新日期:1996-04-01 00:00:00

  • Wear-Resistant, Hemocompatible Ti-Nb-Zr and Zr-Nb Alloys to Improve Blood Pump Design and Performance.

    abstract::Over the past several years, we have developed novel titanium-niobium-zirconium (Ti-Nb-Zr) alloys to address the long-term performance needs of orthopedic implants. The unique properties of these alloys also render them promising candidates for blood pumps. These properties include excellent biocompatibility in combin...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1996.tb04473.x

    authors: Davidson JA,Daigle KP,Kovacs P

    更新日期:1996-05-01 00:00:00

  • Oral treatment for jaundice using immobilized bilirubin oxidase.

    abstract::Jaundice is characterized by an excessive accumulation of bilirubin in the blood and tissues. A novel approach to reduce plasma levels of bilirubin by blocking its enterohepatic circulation was investigated. The treatment consisted of oral administration of immobilized bilirubin oxidase, which could oxidize bilirubin ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1992.tb00527.x

    authors: Soltys PJ,Mullon C,Langer R

    更新日期:1992-08-01 00:00:00

  • Binding of antithrombin to immobilized heparin under varying flow conditions.

    abstract::Rheologic factors are likely to influence the balance between thrombotic and antithrombotic forces at the level of the vascular wall. In this study, the effects of flow-velocity/wall shear stress on the interaction of antithrombin (AT) with surface-immobilized heparin were investigated. The binding of AT to low-affini...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors: Pasche B,Elgue G,Olsson P,Riesenfeld J,Rasmuson A

    更新日期:1991-12-01 00:00:00

  • Outcomes with ventricular assist device versus extracorporeal membrane oxygenation as a bridge to pediatric heart transplantation.

    abstract::Extracorporeal membrane oxygenation (ECMO) has long been the sole means of mechanical support for pediatric patients with end-stage cardiac failure, but has a high waitlist mortality and a reported survival to hospital discharge of less than 50%. The purpose of this study was to compare waitlist mortality and survival...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00969.x

    authors: Jeewa A,Manlhiot C,McCrindle BW,Van Arsdell G,Humpl T,Dipchand AI

    更新日期:2010-12-01 00:00:00