Characteristics of chronically paced cardiac functions in the congenital complete atrioventricular block.

Abstract:

:Characteristics of morphology, cardiac function, and cardiac reserve at late state were evaluated at rest, by changing the pacing rates, and after exercise in patients with ventricular pacemakers for isolated congenital complete atrioventricular block. Heart size was reduced statistically after pacemaker implantation, and concentric myocardial hypertrophy was observed. Cardiac pump functions at rest seemed fairly well compensated by increased ejection fraction, but the cardiac index was still lower than that of the normal heart. Responses of cardiac function towards the changing rates were considered satisfactory, and those variables had statistic correlations with the pacing rates. After exercise, significant increase of cardiac pump function and also statistic acceleration of myocardial function were observed. This fact proved that cardiac reserve was good, although the increased cardiac output after exercise was still insufficient without an increase in heart rate. More physiological pacing modes would be required as currently recommended.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Nawa S,Kioka Y,Shimizu A,Tsuji H,Miyachi Y,Ebara K,Kino K,Shigenobu M,Murakami T,Senoo Y

doi

10.1111/j.1525-1594.1987.tb02667.x

subject

Has Abstract,Author List Incomplete

pub_date

1987-06-01 00:00:00

pages

252-8

issue

3

eissn

0160-564X

issn

1525-1594

journal_volume

11

pub_type

杂志文章
  • High cell-density culture system of hepatocytes entrapped in a three-dimensional hollow fiber module with collagen gel.

    abstract::A compact three-dimensional (3D) module is needed for hepatocyte culture in order to develop an effective hybrid artificial liver system that can retain hepatocellular structure and differentiated functions. We treated the 3D module with collagen gel to entrap rat hepatocytes. This method yielded a high hepatocellular...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1995.tb02310.x

    authors: Takeshita K,Ishibashi H,Suzuki M,Yamamoto T,Akaike T,Kodama M

    更新日期:1995-02-01 00:00:00

  • Is the dog a useful model for accelerated calcification study of cardiovascular bioprostheses?

    abstract::Chitosan posttreatment has been shown to be effective in prevention of calcification of the glutaraldehyde treated bovine pericardium when implanted subdermally in rats for 12 weeks. The efficacy of chitosan posttreatment in complete calcium mitigation of the glutaraldehyde treated porcine aortic valves implanted in t...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb00735.x

    authors: Chanda J,Kuribayashi R,Abe T,Sekine S,Shibata Y,Yamagishi I

    更新日期:1997-05-01 00:00:00

  • Development of cellulose-DNA immunoadsorbent.

    abstract::The aim of this study was to prepare a DNA immunoadsorbent for the specific, extracorporeal removal of anti-DNA antibodies from the blood of patients with systemic lupus erythematosus (SLE) and rheumatoid arthritis (RA). Two kinds of cellulose beads were applied as a carrier. Calf thymus DNA was covalently coupled to ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2002.06721.x

    authors: Kong D,Schuett W,Dai J,Kunkel S,Holtz M,Yamada R,Yu Y,Klinkmann H

    更新日期:2002-02-01 00:00:00

  • Development of a novel centrifugal pump: magnetic rotary pump.

    abstract::The rotational axis of the centrifugal pump has some associated problems such as blood destruction and sealing between the axis and pump housing. To improve upon these deficits we have developed a new type of blood pump, the magnetic rotary pump (MRP). The MRP has an original design with no rotational axis and no impe...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb03734.x

    authors: Naganuma S,Yambe T,Sonobe T,Kobayashi S,Nitta S

    更新日期:1997-07-01 00:00:00

  • Surgical use of fluosol-DA in Jehovah's Witness patients.

    abstract::The effects of Fluosol-DA 20% on circulating blood cells, hemodynamic parameters, blood gases, and organs are described and compared with the results of phase I human studies and animal experiments. Bleeding of preoperative anemia and/or surgical bleeding, Fluosol-DA 20% was administered to 7 of 10 Jehovah's Witness p...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1984.tb04238.x

    authors: Ohyanagi H,Nakaya S,Okumura S,Saitoh Y

    更新日期:1984-02-01 00:00:00

  • The use of an approved biodegradable polymer scaffold as a solid support system for improvement of islet engraftment.

    abstract::The aim of this study was to investigate whether the use of a medically approved biodegradable scaffold as a solid support system would enhance graft survival following transplantation into the omental pouch in a preclinical large animal model. Six beagle dogs underwent total pancreatectomy followed by islet autotrans...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00688.x

    authors: Kin T,O'Neil JJ,Pawlick R,Korbutt GS,Shapiro AM,Lakey JR

    更新日期:2008-12-01 00:00:00

  • Quantification of the secondary flow in a radial coupled centrifugal blood pump based on particle tracking velocimetry.

    abstract::Secondary flow in the centrifugal blood pump helps to enhance the washout effect and to minimize thrombus formation. On the other hand, it has an adverse effect on pump efficiency. Excessive secondary flow may induce hemolytic effects. Understanding the secondary flow is thus important to the design of a compact, effi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2004.29012.x

    authors: Watanabe N,Masuda T,Iida T,Kataoka H,Fujimoto T,Takatani S

    更新日期:2005-01-01 00:00:00

  • Aging adversely impacts biological properties of human bone marrow-derived mesenchymal stem cells: implications for tissue engineering heart valve construction.

    abstract::Our aim was to study the aging effects on the in vitro biological properties of bone marrow-derived mesenchymal stem cells (BMSCs) for construction of tissue-engineered heart valves. BMSCs were taken from teenagers with congenital heart diseases, and middle-aged and elderly patients with valvular diseases. Proliferati...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00824.x

    authors: Xin Y,Wang YM,Zhang H,Li J,Wang W,Wei YJ,Hu SS

    更新日期:2010-03-01 00:00:00

  • Effect of temporary catheter and late referral on hospitalization and mortality during the first year of hemodialysis treatment.

    abstract::Late referral (LR) to dialysis therapy has been associated with poor outcomes in people with end-stage renal disease. This had been ascribed to the frequent use of temporary vascular catheters (TVCs) in LR patients. The effects of LR and TVC on the outcomes of an incident hemodialysis population (n = 101) were investi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2004.00016.x

    authors: Gonçalves EA,Andreoli MC,Watanabe R,Freitas MC,Pedrosa AC,Manfredi SR,Draibe SA,Cendoroglo M,Canziani ME

    更新日期:2004-11-01 00:00:00

  • Outcome analysis for prediction of intraaortic balloon pump support failure and long-term survival in high-risk patients undergoing mitral valve surgery.

    abstract::The outcome predictors of intra-aortic balloon pump (IABP) in patients who undergo mitral valve surgery remain unknown. This study aimed to retrospectively review valvular surgery in patients who received an IABP to identify the predictors of failure of IABP support and anticipate the necessary therapy. This retrospec...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13669

    authors: Liang M,Wang C,Feng K,Chen G,Wang K,Wu Z

    更新日期:2020-08-01 00:00:00

  • Surface modification of silicone rubber membrane by plasma induced graft copolymerization as artificial cornea.

    abstract::In this study a highly biocompatible polymer membrane was prepared by surface modification. An artificial cornea was also developed for clinical applications. Silicone rubber (SR) membrane was grafted with hydrophilic monomers such as 2-hydroxyethyl methacrylate (HEMA) and acrylic acid by plasma induced grafted polyme...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1996.tb00661.x

    authors: Hsiue GH,Lee SD,Chang PC

    更新日期:1996-11-01 00:00:00

  • Femoro-femoral versus atrio-aortic extracorporeal membrane oxygenation: selecting the ideal cannulation technique.

    abstract::Veno-arterial extracorporeal membrane oxygenation (ECMO) may be implanted using peripheral ECMO (pECMO) or central ECMO (cECMO) cannulation techniques. The aim of this study was to compare the outcome between these two cannulation techniques. A retrospective study was performed at Düsseldorf University Hospital from O...

    journal_title:Artificial organs

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/aor.12245

    authors: Saeed D,Stosik H,Islamovic M,Albert A,Kamiya H,Maxhera B,Lichtenberg A

    更新日期:2014-07-01 00:00:00

  • Nitric oxide added to the sweep gas of the oxygenator during cardiopulmonary bypass in infants: A pilot randomized controlled trial.

    abstract::Our objective was to assess the effect of nitric oxide added to the sweep gas of the oxygenator during cardiopulmonary bypass (CPB) in infants on platelet count, platelet function, clinical outcomes, and safety. A randomized, double-blinded, placebo-controlled clinical trial in infants less than a year of age undergoi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13788

    authors: Niebler RA,Chiang-Ching H,Daley K,Janecke R,Jobe SM,Mitchell ME,Varner C,Woods K,Scott JP

    更新日期:2020-08-01 00:00:00

  • Comparison of rapid in situ, regular in situ, and ex vivo flushing on hepatic function.

    abstract::The efficacy of three flushing techniques on subsequent liver function was assessed using the in vivo isolated liver perfusion model (ILPM). Livers from brain-dead mongrel dogs were flushed with cold Euro-Collins as follows: Group I, rapid in situ flushing (10 min); Group II, regular in situ flushing (45 min); Group I...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1988.tb02760.x

    authors: Castellanos J,Toledo-Pereyra LH,Finkelstein I,Kestenberg W,Chapman M,Choudhury S

    更新日期:1988-06-01 00:00:00

  • Biological evaluation of liposome-encapsulated hemoglobin surface-modified with a novel PEGylated nonphospholipid amphiphile.

    abstract::Traumatic injury is often associated with hemorrhagic shock. Liposome-encapsulated hemoglobin (LEH) is being developed as an artificial oxygen carrier to address post-hemorrhage oxygen and volume deficit. Here, we report a new composition of LEH based on the use of polyethylene glycol (PEG2K ) conjugated with nonphosp...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12304

    authors: Yadav VR,Nag O,Awasthi V

    更新日期:2014-08-01 00:00:00

  • Down-regulation of TNF-alpha by small interfering RNA inhibits particle-induced inflammation in vitro.

    abstract::Aseptic joint loosening is a key factor that reduces the life span of arthroplasty. There are currently few effective treatments for joint loosening except surgical revision. We explored the inhibitory effects of tumor necrosis factor (TNF)-alpha-targeted small interfering RNA (siRNA) on particle-induced inflammatory ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2010.01175.x

    authors: Qin CQ,Ding Y,Huang DS,Xu J,Ma RF,Huang JB

    更新日期:2011-07-01 00:00:00

  • Estimation of the native cardiac output from a rotary blood pump flow: in vitro study.

    abstract::The rotary blood pump will be an implantable left ventricular assist device (LVAD) in the near future. However, the best control method and the interrelationship between the rotary blood pump and native heart functions are unclear. An estimation was made of the native heart cardiac output from the change of an LVAD's ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.06127.x

    authors: Nakata K,Ohashi Y,Tayama E,Ohtsuka G,Takami Y,Mueller J,Glueck J,Nosé Y

    更新日期:1998-05-01 00:00:00

  • Clinical use of low porosity woven ultrafine polyester fiber grafts.

    abstract::A woven fabric graft made of ultrafine polyester fibers (UFPF) (Toray Graft, water porosity: 100 ml/min/cm2:120 mm Hg H2O) was clinically applied in 81 cases (28 thoracic aortic aneurysms, 6 thoracoabdominal aortic aneurysms, 42 abdominal aortic aneurysms, and 5 atherosclerotic obstructions of the peripheral arteries)...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1995.tb02245.x

    authors: Satoh S,Niu S,Kanda K,Hirai J,Nakazima S,Wada Y,Oka T,Noishiki Y

    更新日期:1995-01-01 00:00:00

  • Influence of flow design on microcirculation in conditions of undulation pump-left ventricle assist device testing.

    abstract::To study the microvessels in bulbar conjunctiva, we conducted an experiment in goat with a pneumatically driven left heart bypass pump, which was replaced with an undulation pump-left ventricle assist device for 9 days. Three flow patterns were tested: complete pulsatile, continuous, and percentage of pulsatile. We st...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2006.00244.x

    authors: Dobsák P,Novakova M,Baba A,Vasku J,Isoyama T,Saito I,Abe Y,Chinzei T,Imachi K

    更新日期:2006-06-01 00:00:00

  • Uremic neuropathy: evidence of middle molecule toxicity.

    abstract::Ten dialysis patients were followed in a prospective study to determine the neurotoxicity of metabolites in the middle molecule (MM) molecular weight (mol wt) range of 500-200 daltons/molecule. In the absence of readily available direct serum measurements of MM concentrations, a theoretically calculated dialysis index...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1978.tb01002.x

    authors: Milutinovic J,Babb AL,Eschbach JW,Follette WC,Graefe U,Strand MJ,Scribner BH

    更新日期:1978-02-01 00:00:00

  • Quantification of Shear-Induced Platelet Activation: High Shear Stresses for Short Exposure Time.

    abstract::Thrombosis and thromboembolism are the life-threatening clinical complications for patients supported or treated with prosthetic cardiovascular devices. The high mechanical shear stress within these devices is believed to be the major contributing factor to cause platelet activation (PA) and function alteration, leadi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12438

    authors: Ding J,Chen Z,Niu S,Zhang J,Mondal NK,Griffith BP,Wu ZJ

    更新日期:2015-07-01 00:00:00

  • Eccentric roller type total artificial heart creating interatrial shunt.

    abstract::Creating an interatrial shunt to achieve left-right flow balance and modification of the blood chambers to improve the basic performance of the device were performed in developing an eccentric roller type total artificial heart (ERTAH). Smaller blood chambers reduce friction loss and increase durability and energy eff...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06602.x

    authors: Wada H,Fukunaga S,Watari M,Imai K,Sakai H,Shibamura H,Sueda T,Matsuura Y

    更新日期:2000-08-01 00:00:00

  • Thrombogenicity of deflated intraaortic balloon: impact of heparin coating.

    abstract::In a calf model, 3 standard and 3 heparin coated intraaortic balloons (IAB) were inserted and left deflated in the descending aorta during 20 min to simulate balloon rupture. At the end of the experiment, the IAB were examined, and 3 samples of each were collected for scanning electron microscopy (SEM) analysis. None ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06228.x

    authors: Mueller XM,Tevaearai HT,Hayoz D,von Segesser LK

    更新日期:1999-02-01 00:00:00

  • Investigation of parameter estimator and adaptive controller for assist pump by computer simulation.

    abstract::The multi-output adaptive controller of a left ventricular assist device (LVAD) was studied by computer simulation. The controller regulated two outputs--mean aortic pressure (mAoP) and mean atrial pressure (mLAP)--by regulating vacuum pressure (input). The autoregressive models were used to describe the circulatory s...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1991.tb00769.x

    authors: Shimooka T,Mitamura Y,Yuhta T

    更新日期:1991-04-01 00:00:00

  • Significant left ventricular unloading with transaortic catheter venting during venoarterial bypass.

    abstract::Insufficient unloading of the left ventricle with blood stagnation is a main cause of unsuccessful left ventricular (LV) recovery during percutaneous cardiopulmonary support (PCPS). The purpose of this investigation was to evaluate the effectiveness of transaortic catheter venting (TACV) for LV unloading. Six adult mo...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb03744.x

    authors: Shibuya M,Kitamura M,Kurihara H,Kikuchi C,Endo M,Koyanagi H

    更新日期:1997-07-01 00:00:00

  • Effects of pK variability on bicarbonate balance evaluation in dialysis patients.

    abstract::Bicarbonate balance is usually calculated from the Henderson-Hasselbalch equation under the assumption that pK is constant. To evaluate the pK variability and its effects on bicarbonate computed with autoanalyzers in dialysis patients, we studied 44 patients on maintenance hemodialysis. The pH, PCO2, total CO2, and pK...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1987.tb02715.x

    authors: Santoro A,Ferrari G,Spongano M,Cavalli F,Zucchelli P

    更新日期:1987-12-01 00:00:00

  • Usability and safety of ventricular assist devices: human factors and design aspects.

    abstract::The purpose of this study was the investigation of the usability and ergonomics of ventricular assist devices (VADs) in everyday usage. Patients with four different VAD types were observed. After implantation, instruction, and discharge from the hospital, the patients returned on a regular basis to the outpatient clin...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00844.x

    authors: Geidl L,Zrunek P,Deckert Z,Zimpfer D,Sandner S,Wieselthaler G,Schima H

    更新日期:2009-09-01 00:00:00

  • The mechanics of spiral flow: Enhanced washout and transport.

    abstract::Spiral/helical forms of blood flow have been observed in large arteries of the cardiovascular system, but their benefits remain underappreciated. Spiral flow has been postulated to improve near-wall washout, promoting anti-atherothrombotic conditions. This research aims to study the washout characteristics of spiral f...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13520

    authors: Huang Zhang P,Tkatch C,Newman R,Grimme W,Vainchtein D,Kresh JY

    更新日期:2019-12-01 00:00:00

  • Estimation of maximum ventricular elastance under assistance with a rotary blood pump.

    abstract::The maximum ventricular elastance is a reliable index for assessing the cardiac function from changes in its pressure-volume relationship. The advantage of this index is that it can represent the contractility of either unassisted hearts or native hearts assisted with rotary blood pumps. However, there are situations ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00876.x

    authors: Sugai TK,Tanaka A,Yoshizawa M,Shiraishi Y,Yambe T,Nitta S,Baba A

    更新日期:2010-05-01 00:00:00

  • Computational simulation of a non-newtonian model of the blood separation process.

    abstract::The aim of this work is to construct a computational fluid dynamics model capable of simulating the transient non-Newtonian process of apheresis. A Lagrangian-Eulerian model has been developed which tracks the blood particles within a two-dimensional flow configuration. Within the Eulerian method, the fluid mass and m...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2005.00164.x

    authors: De Gruttola S,Boomsma K,Poulikakos D

    更新日期:2005-12-01 00:00:00