Abstract:
:The efficacy of three flushing techniques on subsequent liver function was assessed using the in vivo isolated liver perfusion model (ILPM). Livers from brain-dead mongrel dogs were flushed with cold Euro-Collins as follows: Group I, rapid in situ flushing (10 min); Group II, regular in situ flushing (45 min); Group III, ex vivo flushing (10 min). All livers were then heterotopically transplanted into recipients, using the ILPM, by anastomosis of the portal vein, vena cava, and hepatic artery to the recipient's portal vein, iliac vein, and iliac artery. Reperfusion followed for 30 min. Laboratory samples collected at 0, 5, 15, and 30 min showed that hepatic function was not altered by ex vivo flushing and was only slightly altered by rapid in situ flushing. Regular in situ flushing proved to be damaging to livers. Histological analysis confirmed these findings. Therefore, either rapid in situ or ex vivo flushing can be safely used by the transplant specialist.
journal_name
Artif Organsjournal_title
Artificial organsauthors
Castellanos J,Toledo-Pereyra LH,Finkelstein I,Kestenberg W,Chapman M,Choudhury Sdoi
10.1111/j.1525-1594.1988.tb02760.xsubject
Has Abstractpub_date
1988-06-01 00:00:00pages
222-6issue
3eissn
0160-564Xissn
1525-1594journal_volume
12pub_type
杂志文章abstract::The rotary blood pump will be an implantable left ventricular assist device (LVAD) in the near future. However, the best control method and the interrelationship between the rotary blood pump and native heart functions are unclear. An estimation was made of the native heart cardiac output from the change of an LVAD's ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.1998.06127.x
更新日期:1998-05-01 00:00:00
abstract::To develop a method for making percutaneous devices that have high biocompatibility and do not induce downgrowth of epidermal cells, we prepared a partial decellularized dermis (DD)/poly(methyl methacrylate) (PMMA) complex (PDPC) with a PMMA rod firmly stabilized inside. The porcine decellularized tissue was chosen be...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.12330
更新日期:2014-12-01 00:00:00
abstract::Technological innovations in pediatric extracorporeal life support circuits can reduce system-related complications and may improve patients' outcome. The Deltastream DP3 (Medos Medizintechnik AG, Stolberg, Germany) is a novel rotational pump with a diagonally streamed impeller that can be used over a broad range of f...
journal_title:Artificial organs
pub_type: 杂志文章,多中心研究
doi:10.1111/aor.13016
更新日期:2018-04-01 00:00:00
abstract::Rheologic factors are likely to influence the balance between thrombotic and antithrombotic forces at the level of the vascular wall. In this study, the effects of flow-velocity/wall shear stress on the interaction of antithrombin (AT) with surface-immobilized heparin were investigated. The binding of AT to low-affini...
journal_title:Artificial organs
pub_type: 杂志文章
doi:
更新日期:1991-12-01 00:00:00
abstract::EXTEND (EXTra-uterine Environment for Neonatal Development) is a novel system for supporting extremely premature infants that replicates in utero conditions by maintaining a sterile fluid environment and providing gas exchange via a pumpless arteriovenous oxygenator circuit connected to the umbilical vessels. Target g...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.13524
更新日期:2019-12-01 00:00:00
abstract::Microcapsules containing insulin crystals or islets of Langerhans were made by extruding a mixture of insulin crystals or islets and sodium alginate into a calcium chloride solution, and then coating it with poly-l-lysine. When these microcapsules were incubated at 37 degrees C, insulin could be detected readily in th...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1983.tb04187.x
更新日期:1983-05-01 00:00:00
abstract::This article describes two ongoing numerical studies of fluid-structure interaction in the cardiovascular system: an idealized pulsatile ventricular assist device (VAD), consisting of two fluid chambers separated by a flexible diaphragm; and blood flow and heart wall motion during passive filling of a canine heart. Si...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2008.00644.x
更新日期:2008-11-01 00:00:00
abstract::The use of Berlin Heart EXCOR VAD (BH) is a validated therapy to bridge pediatric patients to heart transplant. Serial echocardiographic (ECHO) assessment of VAD patients is necessary to support patients' management. This work aims at developing an innovative strategy to evaluate the BH device functioning by ECHO and ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.13122
更新日期:2018-04-01 00:00:00
abstract::Adsorption therapy, which treats the autoimmune disease by the selective removal of pathogenic substances from the blood, is an active subject. In this therapy, bioactive molecules such as antigen, antibodies and protein A are usually used as affinity-ligands. The disadvantages of using these substances as affinity-li...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1990.tb02977.x
更新日期:1990-10-01 00:00:00
abstract::The developments in apheresis techniques and their clinical applications world-wide are technologically driven. In the past, apheresis survey statistics have high-lighted both the differences by region in clinical practice and in the types of technologies utilized. Such differences have provided a basis for the scient...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1995.tb02334.x
更新日期:1995-04-01 00:00:00
abstract::Using an ex vivo model, the effects of membrane composition and surface area on both the complement system (as reflected by plasma C3a levels) and platelets [as indicated by plasma concentrations of thromboxane B2 (TXB2) and platelet factor 4 (PF4)] were studied. In this model, polyacrylonitrile (PAN) was associated w...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1987.tb02648.x
更新日期:1987-04-01 00:00:00
abstract::In previous studies, we presented main strategies for suspending the rotor of a mixed-flow type (centrifugal and axial) ventricular assist device (VAD), originally presented by the Institute Dante Pazzanese of Cardiology (IDPC), Brazil. Magnetic suspension is achieved by the use of a magnetic bearing architecture in w...
journal_title:Artificial organs
pub_type: 杂志文章,多中心研究
doi:10.1111/j.1525-1594.2011.01265.x
更新日期:2011-05-01 00:00:00
abstract::Spiral/helical forms of blood flow have been observed in large arteries of the cardiovascular system, but their benefits remain underappreciated. Spiral flow has been postulated to improve near-wall washout, promoting anti-atherothrombotic conditions. This research aims to study the washout characteristics of spiral f...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.13520
更新日期:2019-12-01 00:00:00
abstract::The PI3K/Akt signaling pathway has been implicated in playing an important role in platelet activation during hemostasis and thrombosis involving platelet-matrix interaction and platelet aggregation. Its role in non-physiological shear stress (NPSS)-induced platelet activation relevant to high-shear blood contacting m...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.13465
更新日期:2019-09-01 00:00:00
abstract::As the aortic valve (AV) opens, the pump pressure head remains constant, which is reflected as a "notch/plateau" in pump pressure and flow signals. However, instantaneous flow estimation may be influenced by friction and is particularly difficult in axial pumps. Therefore, a new method to determine the duration of AV ...
journal_title:Artificial organs
pub_type: 杂志文章,多中心研究
doi:10.1111/aor.12570
更新日期:2015-08-01 00:00:00
abstract::Transplanted allogeneic marrow grafts often fail to engraft in a lethally irradiated host. Resistance to hemopoietic allograft is a complexed phenomenon involving multiple components. To study the involvement of a hemopoietic cytokine, which was known to play a role for stem cell function, we established lines of mice...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1996.tb04563.x
更新日期:1996-08-01 00:00:00
abstract::By using high speed gel filtration combined with ion exchange gradient elution chromatography, the concentrations of plasma (p) middle molecules (MM) were determined in 126 samples from 90 non-dialyzed azotemic patients and in 210 pre-dialysis samples from 53 regular hemodialysis and 24 intermittent peritoneal dialysi...
journal_title:Artificial organs
pub_type: 杂志文章
doi:
更新日期:1981-01-01 00:00:00
abstract::Individualized short hemodialysis treatment schedules, approximately three 3-h treatments per week, were introduced in a nephrology unit in 1976. In May 1985, 259 patients had been treated, which corresponds to approximately 60 new patients per million inhabitants per year. Ages at start of therapy ranged between 17 a...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1986.tb02541.x
更新日期:1986-06-01 00:00:00
abstract::The development of a ventricular assist device is depicted. The seven subprograms that make up the project are described briefly. Results obtained during the clinical assay showed that the new design of the input cannula working as a false auricle provides better efficiency, as well as a certain level of autoregulatio...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1994.tb03364.x
更新日期:1994-07-01 00:00:00
abstract::The E4T is a totally implantable total artificial heart (TAH) resulting from many years of research work at the Cleveland Clinic Foundation (CCF) and Nimbus, Inc. It consists of four implanted subsystems: the pumping unit, the variable volume device, the transcutaneous transformer, and the internal battery. The pumpin...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1988.tb02795.x
更新日期:1988-10-01 00:00:00
abstract::The microsystems based visual prosthesis (MiViP) visual prosthesis generates visual perceptions well below safety and stimulator saturation limits. These perceptions, called phosphenes, are of reasonably small size and are broadly distributed in the visual field. They can thus be used to convey useful visual informati...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.2002.06939.x
更新日期:2002-03-01 00:00:00
abstract::To date, single-needle (SN) hemodialysis (HD) requires a dialysis machine equipped with two blood pumps-one controlling arterial blood flow (Qb) and one controlling venous Qb. B. Braun has developed an innovative single-pump SN HD system. Therefore, usability is improved by reducing complexity. The aim of this study w...
journal_title:Artificial organs
pub_type: 杂志文章,随机对照试验
doi:10.1111/aor.13149
更新日期:2018-08-01 00:00:00
abstract::In total, 30 patients suffering from familial hypercholesterolemia, resistant to diet and lipid-lowering drugs, were treated for up to 6 years (3.6 + or - 1.6; range, 0.2-6.8 years) with low-density lipoprotein (LDL) apheresis. Three different systems were used; the dextran sulfate adsorption system (Kaneka) for 27 of...
journal_title:Artificial organs
pub_type: 临床试验,杂志文章
doi:10.1111/j.1525-1594.1996.tb04455.x
更新日期:1996-04-01 00:00:00
abstract::An increasing amount of evidence points to cerebral embolization during cardiopulmonary bypass (CPB) as the principal etiologic factor of neurologic complications. In this study, the capability of capturing and classification of gaseous emboli and pressure drop of three different membrane oxygenators (Sorin Apex, Teru...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2009.00955.x
更新日期:2009-11-01 00:00:00
abstract::Tissue responses to various percutaneous materials with different surface properties and structures were investigated. Dense hydroxyapatite (HA), tricalcium phosphate (TCP), glassy carbon (GC), and 2 types of porous HA were used. Cutaneous and subcutaneous tissues were tightly attached to the surface of the penetratin...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1997.tb00514.x
更新日期:1997-09-01 00:00:00
abstract::Growth factors and morphogens secreted by bone marrow mesenchymal stem cells (BMSCs) of bone marrow fluid may promote tooth regeneration. Accordingly, a tissue engineering approach was utilized to develop an economical strategy for obtaining the growth factors and morphogens from BMSCs. Unerupted second molar tooth bu...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2010.01064.x
更新日期:2011-02-01 00:00:00
abstract::Hemodynamic control of left ventricular assist devices (LVADs) is generally a complicated problem due to diverse operating environments and the variability of the patients: both the changes in the circulatory and metabolic parameters as well as disturbances that require adjustment to the operating point. This challeng...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2007.00350.x
更新日期:2007-02-01 00:00:00
abstract::No standardized treatment algorithm exists for the management of continuous-flow left ventricular assist device (CF-LVAD)-specific infections. The aim of this systematic review and meta-analysis was to compare the outcomes of CF-LVAD-specific infections as managed by device exchange to other treatment modalities not i...
journal_title:Artificial organs
pub_type: 杂志文章,meta分析
doi:10.1111/aor.13378
更新日期:2019-05-01 00:00:00
abstract::Extracorporeal life support (ECLS) has been increasingly utilized to manage cardiac and pulmonary dysfunction. The impact of obesity on outcomes of ECLS is poorly defined. The purpose of the study was to compare in-hospital mortality, resource use, complications, and readmissions in obese versus non-obese patients rec...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.13752
更新日期:2020-11-01 00:00:00
abstract::The aim of this work is to construct a computational fluid dynamics model capable of simulating the transient non-Newtonian process of apheresis. A Lagrangian-Eulerian model has been developed which tracks the blood particles within a two-dimensional flow configuration. Within the Eulerian method, the fluid mass and m...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2005.00164.x
更新日期:2005-12-01 00:00:00