Effects of pK variability on bicarbonate balance evaluation in dialysis patients.

Abstract:

:Bicarbonate balance is usually calculated from the Henderson-Hasselbalch equation under the assumption that pK is constant. To evaluate the pK variability and its effects on bicarbonate computed with autoanalyzers in dialysis patients, we studied 44 patients on maintenance hemodialysis. The pH, PCO2, total CO2, and pK were determined in each patient before and after the dialysis session. The mean total CO2 calculated (22.5 +/- 2.7 meq/L) from pH and PCO2 values was significantly higher (p less than 0.001) than that directly measured (20.4 +/- 3.0 meq/L) with total CO2 analyzer. The mean (+/- SD) pK value was 6.14 +/- 0.06 (range 6.05-6.28). The percentage error in computed bicarbonate due to pK variations from the traditional pK value of 6.1 ranged between -11% and 52%. The pK value changed during dialysis in the majority of our patients, thereby confirming that pK consistency does indeed vary. Thus, investigation of acid-base balance based on pH and PCO2 determination may lead to erroneous results determined by pK abnormalities.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Santoro A,Ferrari G,Spongano M,Cavalli F,Zucchelli P

doi

10.1111/j.1525-1594.1987.tb02715.x

subject

Has Abstract

pub_date

1987-12-01 00:00:00

pages

491-5

issue

6

eissn

0160-564X

issn

1525-1594

journal_volume

11

pub_type

杂志文章
  • Differentiation pattern of Vero cells cultured on poly(L-lactic acid)/poly(hydroxybutyrate-co-hydroxyvalerate) blends.

    abstract::This study evaluates the effect of poly(L-lactic acid) (PLLA) and poly(hydroxybutyrate-cohydroxyvalerate) (PHBV) bioabsorbable polymers and their blends on the induction of alteration of cell growth pattern in vitro. Vero cells were cultured on PLLA, PHBV, and different blends (100/0, 60/40, 50/50, 40/60, and 0/100). ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2004.47199.x

    authors: Santos AR Jr,Ferreira BM,Duek EA,Dolder H,Wada RS,Wada ML

    更新日期:2004-04-01 00:00:00

  • In vitro generation of atrioventricular heart valve neoscaffolds.

    abstract::Tissue engineering of cardiovascular structures represents a novel approach to improve clinical strategies in heart valve disease treatment. The aim of this study was to engineer decellularized atrioventricular heart valve neoscaffolds with an intact ultrastructure and to reseed them with umbilical cord-derived endoth...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12321

    authors: Weymann A,Radovits T,Schmack B,Li S,Korkmaz S,Soós P,Istók R,Veres G,Chaimow N,Karck M,Szabó G

    更新日期:2014-07-01 00:00:00

  • Dialysis reduces portal pressure in patients with chronic hepatitis C.

    abstract::The purpose of this study was to characterize changes in hepatic venous pressures in patients with chronic hepatitis C. The histology and laboratory data from patients with chronic hepatitis C who underwent a transjugular liver biopsy (TJLB) and hepatic venous pressure gradient measurement were analyzed. Portal hypert...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00925.x

    authors: Khurana S,Simcox T,Twaddell W,Drachenberg C,Flasar M

    更新日期:2010-07-01 00:00:00

  • The roles of vascular smooth muscle cells in the aortic wall thinness under prolonged continuous flow left heart bypass.

    abstract::Aortic wall thinness was one of the most characteristic changes observed in experimental animals under prolonged continuous flow left heart bypass. The goal of this study was to determine the roles of smooth muscle cells in the vascular remodeling process in cases demonstrating aortic wall thinness under prolonged con...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2003.00022.x

    authors: Mizuno T,Nishinaka T,Ohnishi H,Tatsumi E,Tsukiya T,Oshikawa M,Shioya K,Takewa Y,Homma A,Takano H,Kitamura S,Taenaka Y

    更新日期:2003-10-01 00:00:00

  • Ductular cholestasis, an unusual form of intrahepatic cholestasis, associated with cardiogenic shock and ventricular assist device.

    abstract::Ventricular assist devices have been shown to be effective in advanced heart failure selected patients. They often have borderline end-organ function, what facilitates organ dysfunction. Liver failure is difficult to manage and leads to increased morbidity and mortality. We report a case of ductular cholestasis, an un...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00760.x

    authors: Mohedano-Gómez A,Pérez-Vela JL,Renes-Carreño E,De-Andrés CI,Corres-Peiretti MA,Arribas-López P,Gutierrez-Rodriguez J,Perales-Rodríguez-De-Viguri N

    更新日期:2010-02-01 00:00:00

  • Effects of hemodynamic conditions and valve sizing on leaflet bending stress in self-expanding transcatheter aortic valve: An in vitro study.

    abstract::Transcatheter aortic valve (TAV) replacement has become a viable alternative to surgery for high and intermediate risk patients with severe aortic stenosis. This technology may extend to the younger and lower risk patients. In this population, long-term durability of the TAV is key. Increased leaflet mechanical stress...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13654

    authors: Stanová V,Zenses AS,Thollon L,Kadem L,Barragan P,Rieu R,Pibarot P

    更新日期:2020-07-01 00:00:00

  • Device exchange versus nonexchange modalities in left ventricular assist device-specific infections: A systematic review and meta-analysis.

    abstract::No standardized treatment algorithm exists for the management of continuous-flow left ventricular assist device (CF-LVAD)-specific infections. The aim of this systematic review and meta-analysis was to compare the outcomes of CF-LVAD-specific infections as managed by device exchange to other treatment modalities not i...

    journal_title:Artificial organs

    pub_type: 杂志文章,meta分析

    doi:10.1111/aor.13378

    authors: Bauer TM,Choi JH,Luc JGY,Weber MP,Moncho Escrivá E,Patel S,Maynes EJ,Boyle AJ,Samuels LE,Entwistle JW,Morris RJ,Massey HT,Tchantchaleishvili V

    更新日期:2019-05-01 00:00:00

  • Surgical use of fluosol-DA in Jehovah's Witness patients.

    abstract::The effects of Fluosol-DA 20% on circulating blood cells, hemodynamic parameters, blood gases, and organs are described and compared with the results of phase I human studies and animal experiments. Bleeding of preoperative anemia and/or surgical bleeding, Fluosol-DA 20% was administered to 7 of 10 Jehovah's Witness p...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1984.tb04238.x

    authors: Ohyanagi H,Nakaya S,Okumura S,Saitoh Y

    更新日期:1984-02-01 00:00:00

  • Cerebral oxygen metabolism during total body flow and antegrade cerebral perfusion at deep and moderate hypothermia.

    abstract::The aim of this study is to evaluate the effect of temperature on cerebral oxygen metabolism at total body flow bypass and antegrade cerebral perfusion (ACP). Neonatal piglets were put on cardiopulmonary bypass (CPB) with the initial flow rate of 200mL/kg/min. After cooling to 18°C (n=6) or 25°C (n=7), flow was reduce...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2010.01131.x

    authors: Sasaki T,Boni L,Riemer RK,Yeung JT,Ramamoorthy C,Beckman R,Gisner C,Shuttleworth P,Hanley FL,Reddy VM

    更新日期:2010-11-01 00:00:00

  • Cerebral and lower limb near-infrared spectroscopy in adults on extracorporeal membrane oxygenation.

    abstract::Percutaneous femoral venoarterial (VA) or jugular venovenous (VV) extracorporeal membrane oxygenation (ECMO) can result in delivery of hypoxic blood to the brain, coronaries, and upper extremities. Additionally, VA-ECMO by percutaneous femoral artery cannulation may compromise perfusion to the lower limbs. Use of near...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2012.01496.x

    authors: Wong JK,Smith TN,Pitcher HT,Hirose H,Cavarocchi NC

    更新日期:2012-08-01 00:00:00

  • The SlideReactor--a simple hollow fiber based bioreactor suitable for light microscopy.

    abstract::Most bioartificial liver support systems are based on hollow fiber capillaries within modified dialysis cartridges or more sophisticated bioreactor constructions. Due to their design microscopic follow-up of reorganization and growth of tissue between the hollow fibers is not possible. The SlideReactor is a simple hol...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2005.29049.x

    authors: Sauer IM,Schwartlander R,Schmid J,Efimova E,Vondran FW,Kehr D,Pless G,Spinelli A,Brandenburg B,Hildt E,Neuhaus P

    更新日期:2005-03-01 00:00:00

  • Pump power loss and heat generation in a pivot bearing-supported Gyro centrifugal pump (C1E3).

    abstract::Pump power loss is defined as input power that is not used for the output work of the pump. Less pump power loss means a higher pump efficiency. A common opinion is that the pump power loss is closely related to heat generation of the pump, which may affect not only the endurance of pump materials, but also blood dama...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1996.tb04542.x

    authors: Takami Y,Nakazawa T,Makinouchi K,Glueck J,Ohara Y,Benkowski RJ,Nosé Y

    更新日期:1996-07-01 00:00:00

  • Optimal continuous retrograde coronary perfusion flow rate with beating heart in normal temperature.

    abstract:PURPOSE:We were led to the premise that with retrograde oxygenated blood perfusion, it would be possible to perform operations on the beating heart. METHODS:The experiment consisted of two stages: procedure 1 and 2. In procedure 1, six pigs were used. Retrograde perfusion flow was controlled to be in the range of 5.0-...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2004.47279.x

    authors: Tsukioka T,Tomita S,Watanabe G,Takemura H

    更新日期:2004-03-01 00:00:00

  • Flow pattern analysis of the Baylor total artificial heart.

    abstract::To obtain an optimal design of the left blood chamber of the total artificial heart (TAH), flow visualization studies were performed. Information on velocities in critical areas of the left chamber was gathered using sectional pulsed laser light. The flow patterns on the entire pumping duration were photographed frame...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1994.tb03345.x

    authors: Meier D,Wernicke JT,Orime Y,Takatani S,Tasai K,Damm G,Naito K,Mizuguchi K,Makinouchi K,Glueck J

    更新日期:1994-12-01 00:00:00

  • Long-term performance of homograft and autograft valves.

    abstract::Five hundred and eighty homograft valves have been inserted into the aortic position as isolated valve replacements, and followed up for 7--14 years. After ten years 90% of frozen homografts, 80% of autografts and 70% of freeze-dried homografts were free of valve-related death. There was only one embolism reported giv...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1980.tb03894.x

    authors: Bodnar E,Wain WH,Martelli V,Ross DN

    更新日期:1980-02-01 00:00:00

  • Assessment of skeletal muscle ventricle tissue blood flow using positron emission tomography.

    abstract::In this pilot study, we assessed the feasibility of using positron emission tomography (PET) imaging for in vivo measurement of skeletal muscle ventricle (SMV) tissue blood flow. In 4 dogs, with SMVs prepared from their latissimus dorsi muscle, we quantified SMV tissue blood flow by PET and related it to the tissue fl...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors: Singh TP,Greer K,Muzik O,Hammond RL,Stephenson LW,Di Carli MF

    更新日期:2001-04-01 00:00:00

  • Sensitivity of the primary stability of a cementless hip stem to its position and orientation.

    abstract::Using computed tomography (CT)-based preoperative planning software, we can define with good accuracy the position of a cementless hip stem inside the host bone, but previous studies suggest that the pose the surgeon achieves during freehand surgery may differ from the planned one even by some millimeters. Advances in...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00577.x

    authors: Reggiani B,Cristofolini L,Taddei F,Viceconti M

    更新日期:2008-07-01 00:00:00

  • Control systems for the electric heart.

    abstract::Methods to predict and control cardiac output (CO) accurately in total artificial heart (TAH) recipients have varied significantly in the last few decades. Early models exhibited minimal control mechanisms and involved fixed pumping parameters. Elaborate electromechanical systems that have recently evolved require int...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors: White RK,Olsen DB

    更新日期:1991-10-01 00:00:00

  • A bridge from short-term to long-term left ventricular assist device--experimental verification of a physiological controller.

    abstract::A physiological controller is a key component to optimize the performance of left ventricular assist devices (LVADs) from short term to long term (10-20 years). The difficulties of its design lie in the inaccurate modeling of any particular human cardiovascular system because of limited knowledge, the large fluctuatio...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2004.07381.x

    authors: Wu Y,Allaire PE,Tao G,Adams M,Liu Y,Wood H,Olsen DB

    更新日期:2004-10-01 00:00:00

  • A nonsurgical technique for blood access in extracorporeal affinity adsorption of antibodies in rats.

    abstract::Monoclonal antibodies for targeting cytotoxic conjugates to tumor cells are currently being evaluated together with extracorporeal affinity adsorption. The aim of the adsorption was to reduce undesired side effects in normal organs and to increase the tumor-to-normal tissue ratios. This technique is also applicable to...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2007.00380.x

    authors: Mårtensson L,Nilsson R,Sjögren HO,Strand SE,Tennvall J

    更新日期:2007-04-01 00:00:00

  • Bacterial and fungal infection in neonates undergoing venoarterial extracorporeal membrane oxygenation: an analysis of the registry data of the extracorporeal life support organization.

    abstract::A review and analysis of 5,001 neonatal venoarterial (VA) extracorporeal membrane oxygenation (ECMO) cases showed that bacterial and fungal infection occurred in 147 (2.9%) and 26 (0.6%) patients, respectively, with an overall incidence of 3.5%. Bivariate analysis was used to compare infected infants with controls, ba...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1996.tb04428.x

    authors: Douglass BH,Keenan AL,Purohit DM

    更新日期:1996-03-01 00:00:00

  • Evaluation of Combined Extracorporeal Life Support and Continuous Renal Replacement Therapy on Hemodynamic Performance and Gaseous Microemboli Handling Ability in a Simulated Neonatal ECLS System.

    abstract::The objective of this study was to evaluate the hemodynamic performance and gaseous microemboli (GME) handling ability of a simulated neonatal extracorporeal life support (ECLS) circuit with an in-line continuous renal replacement therapy (CRRT) device. The circuit consisted of a Maquet RotaFlow centrifugal pump or HL...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12987

    authors: Shank KR,Profeta E,Wang S,O'Connor C,Kunselman AR,Woitas K,Myers JL,Ündar A

    更新日期:2018-04-01 00:00:00

  • Effect of heparin, platelets, activated platelets, platelet fragments, and hematocrit on activated clotting time.

    abstract::Activated clotting time (ACT) is the most commonly used laboratory test to control the heparin effect during extracorporeal techniques. The study was undertaken in order to test in vitro the influence of heparin, platelet count, hematocrit, platelet fragmentation, and platelet activation on ACT. Blood was drawn from v...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06552.x

    authors: Girardi L,Sudi K,Muntean W

    更新日期:2000-07-01 00:00:00

  • Clinical indications for the use of the "Poisk-IOM" total artificial heart: the experience of 13 implantations in humans.

    abstract::Success of total artificial heart (TAH) implantation as a temporary measure depends on three factors: proper patient selection, adequate surgical technique, and safe cardiac prostheses. From 1986 until March 1990, 237 patients with stagnant heart failure were examined. Sixty-one patients (27%) were put on a waiting li...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1991.tb00745.x

    authors: Shumakov V,Zimin N,Kazakov E,Kormer A,Vorontsov S,Nikolaenko E,Kozlov I,Drobyshev A

    更新日期:1991-10-01 00:00:00

  • Association among serum fetuin-A level, coronary artery calcification, and bone mineral densitometry in maintenance hemodialysis patients.

    abstract::Patients with end-stage renal disease have a very high prevalence and extent of arterial calcification. A number of studies suggest that similar pathophysiologic mechanisms are responsible for development and progression of calcification of atherosclerotic plaque and bone formation. Fetuin-A is a potent calcification ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00814.x

    authors: Kirkpantur A,Altun B,Hazirolan T,Akata D,Arici M,Kirazli S,Turgan C

    更新日期:2009-10-01 00:00:00

  • Wear-Resistant, Hemocompatible Ti-Nb-Zr and Zr-Nb Alloys to Improve Blood Pump Design and Performance.

    abstract::Over the past several years, we have developed novel titanium-niobium-zirconium (Ti-Nb-Zr) alloys to address the long-term performance needs of orthopedic implants. The unique properties of these alloys also render them promising candidates for blood pumps. These properties include excellent biocompatibility in combin...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1996.tb04473.x

    authors: Davidson JA,Daigle KP,Kovacs P

    更新日期:1996-05-01 00:00:00

  • Estimation of the native cardiac output from a rotary blood pump flow: in vitro study.

    abstract::The rotary blood pump will be an implantable left ventricular assist device (LVAD) in the near future. However, the best control method and the interrelationship between the rotary blood pump and native heart functions are unclear. An estimation was made of the native heart cardiac output from the change of an LVAD's ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.06127.x

    authors: Nakata K,Ohashi Y,Tayama E,Ohtsuka G,Takami Y,Mueller J,Glueck J,Nosé Y

    更新日期:1998-05-01 00:00:00

  • Elective decompression of the left ventricle in pediatric patients may reduce the duration of venoarterial extracorporeal membrane oxygenation.

    abstract::We aimed to determine the effect of elective left heart decompression at the time of initiation of central venoarterial extracorporeal membrane oxygenation (VA ECMO) on VA ECMO duration and clinical outcomes in children in a single tertiary ECMO referral center with a large pediatric population from a national referra...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12390

    authors: Hacking DF,Best D,d'Udekem Y,Brizard CP,Konstantinov IE,Millar J,Butt W

    更新日期:2015-04-01 00:00:00

  • Tissue-engineered skin containing mesenchymal stem cells improves burn wounds.

    abstract::There is increasing evidence showing that adult stem cells are useful for tissue regeneration. Bone marrow mesenchymal stem cells (MSCs) are self-renewing and are potent in differentiating into multiple cells and tissues. To investigate the practicability of repairing burn wounds with tissue-engineered (TE) skin combi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00654.x

    authors: Liu P,Deng Z,Han S,Liu T,Wen N,Lu W,Geng X,Huang S,Jin Y

    更新日期:2008-12-01 00:00:00

  • Technical aspects on middle molecules: separation, isolation, and identification.

    abstract::For the last few years we have attempted to separate and isolate from biological fluids the uremic Middle Molecules (MM). The first step in the treatment of plasma is an ultrafiltration through AN69 membrane. The samples are fractionated by Sephadex G-15 chromatography into 9 peaks "a" to "i' under precise conditions ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors: Cueille G,Man NK,Sausse A,Farges JP,Funck-Brentano JL

    更新日期:1981-01-01 00:00:00