The use of electrolyzed solutions for the cleaning and disinfecting of dialyzers.

Abstract:

:Recently, the use of electrolyzed solutions has attracted considerable interest in Japan. This study investigates the efficiency of electrolyzed solutions as disinfecting agents (DA) in the reuse of dialyzers and compares their efficiency to that of other disinfectants currently in use. The following 3 methods were employed. First, the rinsing time and rebound release of reused dialyzers were measured and compared after electrolyzed solutions, electrolyzed strong acid aqueous solution (ESAAS) and electrolyzed strong basic aqueous solution (ESBAS), made from reverse osmosis (RO) water (ESAAS, ESBAS; Generating apparatuses: Super Oxseed alpha 1000, Amano Corporation, Yokohama, Japan), 2% Dialox-cj (Teijin Gambro Medical, Tokyo, Japan), and 3.8% formalin were used as DAs. This involved performing dialysis with 2 types of dialyzers: a cellulose acetate membrane (CAM) dialyzer and a polysulfone membrane (PSM) dialyzer. The dialyzers were cleaned and disinfected using the different DA and left for 48 h. Next, after performing dialysis the dialyzer membranes were cleaned with a saline solution (0.9% NaCl) and RO water and then cleaned with the various DA. These membranes were observed using a scanning electron microscope (SEM) to check for the presence of physical and biological contaminants. Finally, in vitro tests were performed to determine the level of dialyzer clearance when PSM dialyzers were reused after having been cleaned and disinfected with the electrolyzed solutions. The rinsing time results for both the CAM and PSM dialyzers showed the electrolyzed solutions (ESBAS and ESAAS) as being undetectable within 10 min. With regard to the rebound release, for both the CAM and PSM dialyzers, the electrolyzed solutions were undetectable at all checking times between 30 and 240 min. Observation by SEM showed that cleaning with both ESAAS and ESBAS left the fewest contaminants, and cleaning with 2% Dialox-cj left the highest level of contaminants in the CAM dialyzers. With regard to experiments concerning use in vitro, no major changes in the dialyzer clearance were noticed after 6 uses. In every experiment, the previous investigations showed the electrolyzed solutions to be superior to 3. 8% formalin and 2% Dialox-cj DA for the reuse of dialyzers.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Tanaka N,Tanaka N,Fujisawa T,Daimon T,Fujiwara K,Yamamoto M,Abe T

doi

10.1046/j.1525-1594.2000.06611.x

subject

Has Abstract

pub_date

2000-12-01 00:00:00

pages

921-8

issue

12

eissn

0160-564X

issn

1525-1594

pii

aor6611

journal_volume

24

pub_type

杂志文章
  • Development and clinical assay of the BCM ventricular assist device.

    abstract::The development of a ventricular assist device is depicted. The seven subprograms that make up the project are described briefly. Results obtained during the clinical assay showed that the new design of the input cannula working as a false auricle provides better efficiency, as well as a certain level of autoregulatio...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1994.tb03364.x

    authors: del Cañizo JF,Antoranz JC,Desco MM,Alvarez-Valdivielso JM,Fernandez-Caleya D,López M,Garcia-Barreno P,Duarte J

    更新日期:1994-07-01 00:00:00

  • Acellular Endocardium as a Novel Biomaterial for the Intima of Tissue-Engineered Small-Caliber Vascular Grafts.

    abstract::We aimed to investigate whether acellular endocardium can be used as a useful biomaterial for the intima of engineered small-caliber vascular grafts. Fresh endocardium was harvested from the swine left atrium and was decellularized by digestion with the decellularization solution of Triton X-100 and SDS containing DNa...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12814

    authors: Wang F,Guan X,Wu T,Qiao J,Han Z,Wu J,Yu X,You Q

    更新日期:2016-12-01 00:00:00

  • Paracorporeal artificial heart in postoperative heart failure.

    abstract::A pneumatically driven artificial heart with a tubular silicone rubber membrane and disc valves was used for functional heart replacement in the paracorporeal mode. A fluidic drive system allows adjustment of the heart rate, positive and negative pressures and systole/diastole ratio. Since August, 1977, the artificial...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1978.tb03465.x

    authors: Turina MT,Bosio R,Senning A

    更新日期:1978-08-01 00:00:00

  • Extracorporeal endotoxin removal by immobilized polyethylenimine.

    abstract::The neutralization of bacterial endotoxins (ET) is still an unsolved problem in therapeutic medicine. The efficacy of anti-endotoxin antibodies or receptor antagonists and other substances interfering with the endotoxin-induced pathomechanisms is dependent on an intact cellular degradation system of the host. However,...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1993.tb00630.x

    authors: Mitzner S,Schneidewind J,Falkenhagen D,Loth F,Klinkmann H

    更新日期:1993-09-01 00:00:00

  • The monomeric formulation optimization of dental composite: mechanical and kinetic studies.

    abstract::The optimization of the monomer composition, using a polymerization kinetic study and the mechanical behavior study of the composites, was the principal objective of this work. The monomeric mixture analyzed is a part of the composite that has been in development at the University of Campinas, Brazil. Parameters such ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2003.07250.x

    authors: López Palacio RE,de Carvalho Zavaglia CA

    更新日期:2003-05-01 00:00:00

  • The impact of obesity on outcomes in patients receiving extracorporeal life support.

    abstract::Extracorporeal life support (ECLS) has been increasingly utilized to manage cardiac and pulmonary dysfunction. The impact of obesity on outcomes of ECLS is poorly defined. The purpose of the study was to compare in-hospital mortality, resource use, complications, and readmissions in obese versus non-obese patients rec...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13752

    authors: Christian-Miller N,Hadaya J,Nakhla M,Sanaiha Y,Madrigal J,Emami S,Cale M,Sareh S,Benharash P

    更新日期:2020-11-01 00:00:00

  • Treatment of thyrotoxic crisis with plasmapheresis and single pass albumin dialysis: a case report.

    abstract::Thyrotoxic crisis (thyroid storm) is a life-threatening condition. Standard therapy is based on thiamazole, prednisolone, and nonselective beta-blockers. Extracorporeal plasmapheresis is an additional tool for removing circulating thyroxine in patients who do not respond quickly to conventional standard therapy. As th...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00924.x

    authors: Koball S,Hickstein H,Gloger M,Hinz M,Henschel J,Stange J,Mitzner S

    更新日期:2010-02-01 00:00:00

  • Circulatory loop design and components introduce artifacts impacting in vitro evaluation of ventricular assist device thrombogenicity: A call for caution.

    abstract::Mechanical circulatory support (MCS) devices continue to be hampered by thrombotic adverse events (AEs), a consequence of device-imparted supraphysiologic shear stresses, leading to shear-mediated platelet activation (SMPA). In advancing MCS devices from design to clinical use, in vitro circulatory loops containing th...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13626

    authors: Li M,Walk R,Roka-Moiia Y,Sheriff J,Bluestein D,Barth EJ,Slepian MJ

    更新日期:2020-06-01 00:00:00

  • Combining novel biomolecules and stimuli-sensitive biomaterials into new recognition-response biomaterial systems.

    abstract::An important present and emerging trend in biomaterials development is the synthesis of polymers which combine capabilities of biologic recognition ("biomimetic") with sensitivity to small environmental changes ("stimuli-responsive"). This short article highlights some of the many opportunities and challenges in this ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1988.tb02813.x

    authors: Hoffman AS

    更新日期:1988-12-01 00:00:00

  • Effect of a balanced biventricular bypass system on left ventricular energies.

    abstract::Left dominant biventricular failure is a common type of heart failure after cardiac surgery. We developed a biventricular bypass (BVB) system for treatment of postcardiotomy ventricular failure, and we previously reported that the clinical results of the BVB system were superior to those obtained with venoarterial byp...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.06015.x

    authors: Kodera K,Kitamura M,Shibuya M,Kurihara H,Koyanagi H

    更新日期:1998-09-01 00:00:00

  • A bedside micromethod for the determination of total carbon dioxide in biological fluids.

    abstract::The quality control of bicarbonate hemodialysis requires the determination of TCO2, either in blood or in dialysate. The use of the M + D TCO2 kit, a bedside micromethod, gave the authors an economical and reliable solution to this problem. ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1985.tb04404.x

    authors: Canaud B,Araujo A,Nguyen QV,Flavier JL,Mion C

    更新日期:1985-11-01 00:00:00

  • Termination of extracorporeal membrane oxygenation for cardiac support.

    abstract::The determination of when to stop extracorporeal membrane oxygenation (ECMO) rests upon demonstration of the return of adequate cardiac function to support vital organs and permit subsequent recovery. In general, patients with myocardial stun will recover function within several days. Factors that limit recovery inclu...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06445.x

    authors: Steinhorn DM

    更新日期:1999-11-01 00:00:00

  • Outcomes with ventricular assist device versus extracorporeal membrane oxygenation as a bridge to pediatric heart transplantation.

    abstract::Extracorporeal membrane oxygenation (ECMO) has long been the sole means of mechanical support for pediatric patients with end-stage cardiac failure, but has a high waitlist mortality and a reported survival to hospital discharge of less than 50%. The purpose of this study was to compare waitlist mortality and survival...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00969.x

    authors: Jeewa A,Manlhiot C,McCrindle BW,Van Arsdell G,Humpl T,Dipchand AI

    更新日期:2010-12-01 00:00:00

  • Coronary artery anatomy of the goat.

    abstract::The coronary arteries of the goat heart were studied using angiographic techniques and molds of the coronary vessel trees. Blood supplies to the left and right ventricles, interventricular septum, atrioventricular node, and apex of the caprine heart were studied. The goat possesses a left dominant pattern of coronary ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1983.tb04192.x

    authors: Lipovetsky G,Fenoglio JJ,Gieger M,Srinivasan MR,Dobelle WH

    更新日期:1983-05-01 00:00:00

  • Adult polycystic kidney disease: who needs hospital follow-up?

    abstract::Clinical data from 120 adult patients with genetically undifferentiated polycystic kidney disease who had been followed up for more than 3 months (range 3-172) were reviewed in order to try to identify clinical indicators that might predict deterioration in renal function. They were split into two groups dependent on ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2012.01441.x

    authors: Griveas I,Bishop K,World M

    更新日期:2012-07-01 00:00:00

  • Estimation of maximum ventricular elastance under assistance with a rotary blood pump.

    abstract::The maximum ventricular elastance is a reliable index for assessing the cardiac function from changes in its pressure-volume relationship. The advantage of this index is that it can represent the contractility of either unassisted hearts or native hearts assisted with rotary blood pumps. However, there are situations ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00876.x

    authors: Sugai TK,Tanaka A,Yoshizawa M,Shiraishi Y,Yambe T,Nitta S,Baba A

    更新日期:2010-05-01 00:00:00

  • A new smartphone-based method for wound area measurement.

    abstract::Proper wound healing can be assessed by monitoring the wound surface area. Its reduction by 10 or 50% should be achieved after 1 or 4 weeks, respectively, from the start of the applied therapy. There are various methods of wound area measurement, which differ in terms of the cost of the devices and their accuracy. Thi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12169

    authors: Foltynski P,Ladyzynski P,Wojcicki JM

    更新日期:2014-04-01 00:00:00

  • Intestinal tissue oxygenation and tumor necrosis factor-alpha release during systemic blood flow changes in pigs with left ventricular assist devices.

    abstract::We previously demonstrated that tumor necrosis factor-alpha (TNF-alpha) increased following a reduction in systemic blood flow to 60% or less of the original cardiac output using a left ventricular assist device (LVAD). The aim of this study was to investigate the effect of reducing systemic blood flow on tissue oxyge...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2001.025001053.x

    authors: Uozaki Y,Dihmis WC,Yamauchi H,Moczar M,Miyama M,Pasteau F,Tixier D,Bambang SL,Loisance DY

    更新日期:2001-01-01 00:00:00

  • Prediction of postdialysis serum sodium concentration and transcellular fluid shift without measuring body fluid volumes.

    abstract::The postdialysis levels of serum sodium concentration, urea concentration, and osmolality, as well as the magnitude of both transcellular fluid shifts and sodium removal, were predicted based on computer modeling without measuring body fluid volumes. A 4-h hemodialysis was performed in five patients at a constant ultr...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1983.tb04219.x

    authors: Kimura G,Van Stone JC,Bauer JH

    更新日期:1983-11-01 00:00:00

  • Extracorporeal Life Support in Out-of-Hospital Refractory Cardiac Arrest.

    abstract::Out-of-Hospital refractory Cardiac Arrest (OHrCA) has a mortality rate between 90 and 95%. Since 2009, French medical academic societies have recommended the use of extracorporeal life support (ECLS) for OHrCA. According to these guidelines, patients were eligible for ECLS support if vital signs were still present dur...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12655

    authors: Rousse N,Robin E,Juthier F,Hysi I,Banfi C,Al Ibrahim M,Coadou H,Goldstein P,Wiel E,Vincentelli A

    更新日期:2016-09-01 00:00:00

  • Computational simulation of a non-newtonian model of the blood separation process.

    abstract::The aim of this work is to construct a computational fluid dynamics model capable of simulating the transient non-Newtonian process of apheresis. A Lagrangian-Eulerian model has been developed which tracks the blood particles within a two-dimensional flow configuration. Within the Eulerian method, the fluid mass and m...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2005.00164.x

    authors: De Gruttola S,Boomsma K,Poulikakos D

    更新日期:2005-12-01 00:00:00

  • Bioengineered cartilage in a scaffold-free method by human cartilage-derived progenitor cells: a comparison with human adipose-derived mesenchymal stromal cells.

    abstract::The objective of our study was to investigate chondrogenesis potential of human adipose-derived mesenchymal stromal cells (MSCs), using as a positive control a human source of cartilage-derived progenitor cells (PCs). This source of PCs was recently described by our group and dwells on the surface of nasoseptal cartil...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12121

    authors: Baptista LS,Silva KR,Pedrosa CS,Amaral RJ,Belizário JV,Borojevic R,Granjeiro JM

    更新日期:2013-12-01 00:00:00

  • The influence of the dialysate flow rate on hollow fiber hemodialyzer performance.

    abstract::The clearance characteristics of two sizes of hemodialyzers (0.9 m2 and 1.5 m2) from the same range of products have been studied over the dialysate flow range of 500-3,000 ml/min to establish the device's overall mass transfer resistance characteristics. The results obtained demonstrate a difference in the overall ma...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1995.tb02279.x

    authors: Allen R,Frost TH,Hoenich NA

    更新日期:1995-11-01 00:00:00

  • Reversal of experimental posthepatectomy liver failure in pigs: a new application of hepatocyte bioreactors.

    abstract::Postoperative liver failure remains a major cause of morbidity and mortality after extensive hepatectomies. This study aims to evaluate the effectiveness of a hepatocyte bioreactor in the treatment of experimental post-hepatectomy liver failure. Our experimental model included a combination of a side-to-side portacava...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2010.01016.x

    authors: Arkadopoulos N,Kostopanagiotou G,Nastos C,Papalois A,Papoutsidakis N,Kalimeris K,Defterevos G,Kanna T,Polyzois K,Kampouroglou G,Kypriotis D,Costopanagiotou C,Pafiti A,Tzanatos H,Smyrniotis V

    更新日期:2011-01-01 00:00:00

  • Microcirculation and artificial heart research.

    abstract::Small blood vessels may play a more important role in artificial heart (AH) recipients than ever suspected before. Observations of elevated total peripheral resistance, low hematocrit, reduced oncotic pressure, high circulating blood volume, and arterial pulsations with nonpulsatile devices require consideration of pe...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1988.tb01529.x

    authors: Lübbe AS

    更新日期:1988-02-01 00:00:00

  • The compliance problem: a major obstacle in the development of implantable blood pumps.

    abstract::The compliance problem represents a major obstacle in the development of implantable blood pumps. The motor-driven pumps are enclosed in an airtight casing with gas in the motor space. The trapped gas in the motor space either increases the load on the motor during systole or impedes blood sac filling. Potential solut...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1984.tb04248.x

    authors: Lee S,Rosenberg G,Donachy JH,Wisman CB,Pierce WS

    更新日期:1984-02-01 00:00:00

  • Are standard human coagulation tests suitable in pigs and calves during extracorporeal circulation?

    abstract::The thrombogenicity of membrane oxygenators as well as clotting parameters profiles, using standard human clotting tests, was analyzed in calves and pigs during 6 h perfusion. Three calves and 3 pigs were connected to extracorporeal circulation with standard heparinization. Blood samples were taken for coagulation var...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2001.025007579.x

    authors: Mueller XM,Tevaearai HT,Jegger D,Tucker O,von Segesser LK

    更新日期:2001-07-01 00:00:00

  • Re-endothelialization of non-detergent decellularized porcine vessels.

    abstract::Tissue engineering utilizes an interdisciplinary approach to generate constructs for the treatment and repair of diseased organs. Generation of small vessels as vascular grafts or as envisioned central vessel for vascularized constructs is still a challenge. Here, the decellularization of porcine vessels by a non-dete...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13836

    authors: Eyre K,Samper E,Haverich A,Hilfiker A,Andrée B

    更新日期:2020-10-01 00:00:00

  • Intermittent stops of shear reduce the mechanical damage of red blood cells.

    abstract::Continuous and intermittent high shear were loaded to red blood cells in a cone and a plate rheoscope. The mechanical damage to red cells was compared for continuous and intermittent shear. The intermittent shear was achieved by alternately starting and stopping shear repeatedly. In the case of intermittent shear load...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2007.00408.x

    authors: Mizunuma H,Sakai S

    更新日期:2007-06-01 00:00:00

  • A New 2D Echocardiographic Approach to Evaluate the Membrane and Valve Movement of the Berlin Heart EXCOR VAD Chamber in Pediatric VAD Patients.

    abstract::The use of Berlin Heart EXCOR VAD (BH) is a validated therapy to bridge pediatric patients to heart transplant. Serial echocardiographic (ECHO) assessment of VAD patients is necessary to support patients' management. This work aims at developing an innovative strategy to evaluate the BH device functioning by ECHO and ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13122

    authors: Di Molfetta A,Iacobelli R,Ferrari G,Filippelli S,Perri G,Toscano A,Adorisio R,Guccione P,Amodeo A

    更新日期:2018-04-01 00:00:00