Pre- and postoperative magnetic resonance imaging in neonatal arterial switch operation using warm perfusion.

Abstract:

:Neurological morbidity is a major concern in pediatric cardiac surgery. Cardiopulmonary bypass is one of the few modifiable factors affecting neurodevelopmental outcome. This study aimed to measure the incidence of abnormalities apparent by magnetic resonance imaging (MRI) after neonatal arterial switch operation using warm surgery. Neonates admitted for transposition of the great arteries underwent pre- and postoperative brain MRI. They were operated on using a warm perfusion method. The data collected included antenatal diagnosis, place of birth, gestational age, total maturation score as described by Childs, weight, cyanosis as assessed by minimal SpO(2) sustained for at least 10 min, balloon atrial septostomy, prostaglandin E1 infusion, need for neonatal intensive care, bypass time, time to extubation, and length of stay in intensive care. All of the MRI results were interpreted by the same senior specialist in pediatric neuroimaging, and lesions were classified as white matter injury, infarct, or hemorrhage. On preoperative exam, nine patients (42%) had one or more lesions, with infarct in four patients, white matter injury in four patients, and hemorrhage in five. We were unable to find any correlation between the data collected and brain injury. On postoperative exam, there was one new infarct, two new cases of white matter injury, and three cases of hemorrhage but no worsening of the preoperative lesions. Based on this initial experience with brain imaging, there is no deleterious effect of warm perfusion and no rationale to postpone surgery in neonates with "subclinical" brain injury.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Durandy Y,Rubatti M,Couturier R,Rohnean A

doi

10.1111/j.1525-1594.2011.01325.x

subject

Has Abstract

pub_date

2011-11-01 00:00:00

pages

1115-8

issue

11

eissn

0160-564X

issn

1525-1594

journal_volume

35

pub_type

杂志文章
  • Anionic collagen: polymer composites with improved dielectric and rheological properties.

    abstract::This work describes the preparation and characterization of anionic collagen composites with rhamsan and vinylidene fluoride-trifluorethylene with improved rheological and dielectric properties without loss of collagen secondary structure with an interaction occurring between both macromolecules of the composites. On ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.06109.x

    authors: Goissis G,Piccirili L,Goes JC,de Guzzi Plepis AM,Das-Gupta DK

    更新日期:1998-03-01 00:00:00

  • General planning of an artificial organ center.

    abstract::There is an increasing need for research and development centers to deal with design and evaluation of organ replacement systems, the improvement of older devices, and the study of biocompatibility problems. Special attention, in this article, is focused on the determinant role of the background of the investigators i...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1989.tb01579.x

    authors: Vanholder R,Ringoir S

    更新日期:1989-12-01 00:00:00

  • Prolonged left ventricular dysfunction induced by sequential multifocal ischemic infarcts in dogs.

    abstract::A method of creating multifocal ischemia in animals leading to left ventricular (LV) functional impairment is described. In a series of 10 mongrel dogs, electrodes were implanted in multiple branches of the coronary arteries. Subsequently, in seven animals, an 800-microA anodal current was applied for 3 h repeatedly o...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1984.tb04321.x

    authors: Polanski J,Mandell G,Wasfie T,Freed PS,Yoshizu H,Stein PD,Sabbah HN,Kantrowitz A

    更新日期:1984-11-01 00:00:00

  • The use of an approved biodegradable polymer scaffold as a solid support system for improvement of islet engraftment.

    abstract::The aim of this study was to investigate whether the use of a medically approved biodegradable scaffold as a solid support system would enhance graft survival following transplantation into the omental pouch in a preclinical large animal model. Six beagle dogs underwent total pancreatectomy followed by islet autotrans...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00688.x

    authors: Kin T,O'Neil JJ,Pawlick R,Korbutt GS,Shapiro AM,Lakey JR

    更新日期:2008-12-01 00:00:00

  • Computational simulation of a non-newtonian model of the blood separation process.

    abstract::The aim of this work is to construct a computational fluid dynamics model capable of simulating the transient non-Newtonian process of apheresis. A Lagrangian-Eulerian model has been developed which tracks the blood particles within a two-dimensional flow configuration. Within the Eulerian method, the fluid mass and m...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2005.00164.x

    authors: De Gruttola S,Boomsma K,Poulikakos D

    更新日期:2005-12-01 00:00:00

  • Effect of moisture on and kinetic features of the ultrafiltration rate of dialysis membrane.

    abstract::The kinetic features of ultrafiltration of cellulose dialysis membrane stored under various humidity and temperature conditions were studied to obtain basic information of shelf-life characteristics of dialyzers. The ultrafiltration rate (UFR) decreased with time and the UFR-time curve suggested that the UFR would app...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1981.tb04003.x

    authors: Sato H,Kidaka T

    更新日期:1981-08-01 00:00:00

  • Device exchange versus nonexchange modalities in left ventricular assist device-specific infections: A systematic review and meta-analysis.

    abstract::No standardized treatment algorithm exists for the management of continuous-flow left ventricular assist device (CF-LVAD)-specific infections. The aim of this systematic review and meta-analysis was to compare the outcomes of CF-LVAD-specific infections as managed by device exchange to other treatment modalities not i...

    journal_title:Artificial organs

    pub_type: 杂志文章,meta分析

    doi:10.1111/aor.13378

    authors: Bauer TM,Choi JH,Luc JGY,Weber MP,Moncho Escrivá E,Patel S,Maynes EJ,Boyle AJ,Samuels LE,Entwistle JW,Morris RJ,Massey HT,Tchantchaleishvili V

    更新日期:2019-05-01 00:00:00

  • Clinical use of low porosity woven ultrafine polyester fiber grafts.

    abstract::A woven fabric graft made of ultrafine polyester fibers (UFPF) (Toray Graft, water porosity: 100 ml/min/cm2:120 mm Hg H2O) was clinically applied in 81 cases (28 thoracic aortic aneurysms, 6 thoracoabdominal aortic aneurysms, 42 abdominal aortic aneurysms, and 5 atherosclerotic obstructions of the peripheral arteries)...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1995.tb02245.x

    authors: Satoh S,Niu S,Kanda K,Hirai J,Nakazima S,Wada Y,Oka T,Noishiki Y

    更新日期:1995-01-01 00:00:00

  • Double filtration plasmapheresis for the treatment of rheumatoid arthritis: a study of 21 cases.

    abstract::The treatment of rheumatoid arthritis remains difficult and often controversial. Plasma exchange has been advocated in some cases. In the present study 71 sessions of double filtration plasmapheresis (DFPP) were performed in 21 patients with rheumatoid arthritis in an average of 3.7 +/- 1.1 sessions per patient within...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb00344.x

    authors: Liu JD,Zhang C,Li WS,Lun LD

    更新日期:1997-02-01 00:00:00

  • Lipid apheresis: from a heroic treatment to routine clinical practice.

    abstract::Lipid apheresis has developed from a heroic treatment into a routine clinical therapy and currently is the major indication for performing extracorporeal plasma therapy. Whereas it was once reserved for patients with homozygous familial hypercholesterolemia, today it has a place in the secondary prevention of severe c...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1111/j.1525-1594.1996.tb04525.x

    authors: Bosch T

    更新日期:1996-05-01 00:00:00

  • Assessment of skeletal muscle ventricle tissue blood flow using positron emission tomography.

    abstract::In this pilot study, we assessed the feasibility of using positron emission tomography (PET) imaging for in vivo measurement of skeletal muscle ventricle (SMV) tissue blood flow. In 4 dogs, with SMVs prepared from their latissimus dorsi muscle, we quantified SMV tissue blood flow by PET and related it to the tissue fl...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors: Singh TP,Greer K,Muzik O,Hammond RL,Stephenson LW,Di Carli MF

    更新日期:2001-04-01 00:00:00

  • The influence of the dialysate flow rate on hollow fiber hemodialyzer performance.

    abstract::The clearance characteristics of two sizes of hemodialyzers (0.9 m2 and 1.5 m2) from the same range of products have been studied over the dialysate flow range of 500-3,000 ml/min to establish the device's overall mass transfer resistance characteristics. The results obtained demonstrate a difference in the overall ma...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1995.tb02279.x

    authors: Allen R,Frost TH,Hoenich NA

    更新日期:1995-11-01 00:00:00

  • A compact mock circulation loop for the in vitro testing of cardiovascular devices.

    abstract::In vitro cardiovascular device performance evaluation in a mock circulation loop (MCL) is a necessary step prior to in vivo testing. A MCL that accurately represents the physiology of the cardiovascular system accelerates the assessment of the device's ability to treat pathological conditions. To serve this purpose, a...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2010.01088.x

    authors: Timms DL,Gregory SD,Greatrex NA,Pearcy MJ,Fraser JF,Steinseifer U

    更新日期:2011-04-01 00:00:00

  • Pulse conductance and flow-induced hemolysis during pulsatile cardiopulmonary bypass.

    abstract::In this study, the hypothesis was tested that a low-resistant, high-compliant oxygenator provides better pulse conductance and less hemolysis than a high-resistant, low-compliant oxygenator during pulsatile cardiopulmonary bypass. Forty adults undergoing coronary artery bypass surgery were randomly divided into two gr...

    journal_title:Artificial organs

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/j.1525-1594.2009.00853.x

    authors: Simons AP,Wortel P,van Kan RA,van der Veen FH,Weerwind PW,Maessen JG

    更新日期:2010-04-01 00:00:00

  • Clinical experience with BioMedicus centrifugal ventricular support in 172 patients.

    abstract::One hundred and seventy-two patients at The Methodist Hospital in Houston, Texas, were placed on BioMedicus centrifugal ventricular support. One hundred thirty-nine patients were male and 33 were female with a mean age of 59.7 years. Reasons for support were postcardiotomy cardiac failure (129 patients), cardiac allog...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1995.tb02419.x

    authors: Noon GP,Ball JW Jr,Papaconstantinou HT

    更新日期:1995-07-01 00:00:00

  • Effects of atrial arrhytmias on the regurgitation of a monoleaflet prosthetic heart valve.

    abstract::Many patients who receive a prosthetic heart valve also have or acquire cardiac arrhythmias. However, most in vitro studies of prosthetic valves examine them under normal rhythms. In this study, a monoleaflet prosthetic heart valve was tested in vitro under conditions that simulated normal sinus rhythm, first degree a...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2005.29101.x

    authors: Zapanta CM

    更新日期:2005-08-01 00:00:00

  • Selective inhibition of resistance to hemopoietic allografts but not rejection to a natural killer cell sensitive tumor in transgenic mice for granulocyte colony stimulating factor.

    abstract::Transplanted allogeneic marrow grafts often fail to engraft in a lethally irradiated host. Resistance to hemopoietic allograft is a complexed phenomenon involving multiple components. To study the involvement of a hemopoietic cytokine, which was known to play a role for stem cell function, we established lines of mice...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1996.tb04563.x

    authors: Kokai Y,Kimura H,Matsuura A,Fujimoto J

    更新日期:1996-08-01 00:00:00

  • Wear-Resistant, Hemocompatible Ti-Nb-Zr and Zr-Nb Alloys to Improve Blood Pump Design and Performance.

    abstract::Over the past several years, we have developed novel titanium-niobium-zirconium (Ti-Nb-Zr) alloys to address the long-term performance needs of orthopedic implants. The unique properties of these alloys also render them promising candidates for blood pumps. These properties include excellent biocompatibility in combin...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1996.tb04473.x

    authors: Davidson JA,Daigle KP,Kovacs P

    更新日期:1996-05-01 00:00:00

  • Single axis controlled hybrid magnetic bearing for left ventricular assist device: hybrid core and closed magnetic circuit.

    abstract::In previous studies, we presented main strategies for suspending the rotor of a mixed-flow type (centrifugal and axial) ventricular assist device (VAD), originally presented by the Institute Dante Pazzanese of Cardiology (IDPC), Brazil. Magnetic suspension is achieved by the use of a magnetic bearing architecture in w...

    journal_title:Artificial organs

    pub_type: 杂志文章,多中心研究

    doi:10.1111/j.1525-1594.2011.01265.x

    authors: da Silva I,Horikawa O,Cardoso JR,Camargo FA,Andrade AJ,Bock EG

    更新日期:2011-05-01 00:00:00

  • Substitution of acetic acid for hydrochloric acid in the bicarbonate buffered dialysate.

    abstract::In a multicenter study including 5 dialysis units, blood acetate changes during 4 h dialysis sessions in 141 patients treated with a 4 mM acetate-containing bicarbonate dialysate (ABD) were evaluated and compared to the values of 114 patients using an acetate-free bicarbonate dialysate (AFD). Acetate-free bicarbonate ...

    journal_title:Artificial organs

    pub_type: 杂志文章,多中心研究

    doi:10.1046/j.1525-1594.1998.06205.x

    authors: Fournier G,Potier J,Thébaud HE,Majdalani G,Ton-That H,Man NK

    更新日期:1998-07-01 00:00:00

  • Beyond the VAD: Human Factors Engineering for Mechanically Assisted Circulation in the 21st Century.

    abstract::Thousands of ventricular assist devices (VADs) currently provide circulatory support to patients worldwide, and dozens of heart pump designs for adults and pediatric patients are under various stages of development in preparation for translation to clinical use. The successful bench-to-bedside development of a VAD inv...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1111/aor.12600

    authors: Throckmorton AL,Patel-Raman SM,Fox CS,Bass EJ

    更新日期:2016-06-01 00:00:00

  • Miniaturized centrifugal ventricular assist device for bridge to decision: Preclinical chronic study in a bovine model.

    abstract::We developed a novel miniaturized extracorporeal centrifugal pump "BIOFLOAT NCVC (Nipro Corporation Osaka, Japan) as a ventricular assist device (VAD) and performed a preclinical study that is part of the process for its approval as a bridge to decision by the pharmaceutical and medical device agencies. The aim of thi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13459

    authors: Shimamura J,Mizuno T,Takewa Y,Tsukiya T,Naito N,Akiyama D,Iizuka K,Katagiri N,Nishimura T,Ono M,Tatsumi E

    更新日期:2019-09-01 00:00:00

  • Low-intensity ultrasound stimulation enhances chondrogenic differentiation in alginate culture of mesenchymal stem cells.

    abstract::Mesenchymal stem cells (MSCs) are regarded as a potential autologous source for cartilage repair, because they can differentiate into chondrocytes by transforming growth factor-beta (TGF-beta) treatment under the 3-dimensional (3-D) culture condition. However, more efficient and versatile methods for chondrogenic diff...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2006.00288.x

    authors: Lee HJ,Choi BH,Min BH,Son YS,Park SR

    更新日期:2006-09-01 00:00:00

  • What Is the Optimal Setting for a Continuous-Flow Left Ventricular Assist Device in Severe Mitral Regurgitation?

    abstract::Excessive left ventricular (LV) volume unloading can affect right ventricular (RV) function by causing a leftward shift of the interventricular septum in patients with mitral regurgitation (MR) receiving left ventricular assist device (LVAD) support. Optimal settings for the LVAD should be chosen to appropriately cont...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12702

    authors: Naito N,Nishimura T,Takewa Y,Kishimoto S,Date K,Umeki A,Ando M,Ono M,Tatsumi E

    更新日期:2016-11-01 00:00:00

  • The analysis of driving mode influence on energy dissipation in pneumatic artificial heart chambers.

    abstract::The energy dissipated in blood or on a total artificial heart (TAH) chamber's elements directly or indirectly decreases the biological or technical safety of the TAH's work. The energetic analysis of the Polish total artificial heart (POLTAH) external work with the objective of estimating the valve and membrane roles ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.05074.x

    authors: Nawrat Z,Malota Z

    更新日期:1998-10-01 00:00:00

  • Development of an intravascular pumping oxygenator using a new silicone membrane.

    abstract::A new intravascular pumping oxygenator (IVPO) was developed for intravascular gas exchange and circulatory assistance in critically ill patients with respiratory and circulatory failure. The IVPO utilizes new silicone hollow fibers (diameter, 1 mm; membrane width, 50 microns) and consists of two driving tubes for the ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb00703.x

    authors: Sueda T,Fukunaga S,Morita S,Sueshiro M,Hirai S,Okada K,Orihashi K,Matsuura Y

    更新日期:1997-01-01 00:00:00

  • In Vitro Assessment of Electric Currents Increasing the Effectiveness of Vancomycin Against Staphylococcus epidermidis Biofilms.

    abstract::Biofilms are communities of bacteria that can cause infections which are resistant to the immune system and antimicrobial treatments, posing a significant threat for patients with implantable and indwelling medical devices. The purpose of our research was to determine if utilizing specific parameters for electric curr...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12678

    authors: Haddad PA,Mah TF,Mussivand T

    更新日期:2016-08-01 00:00:00

  • Technical aspects on middle molecules: separation, isolation, and identification.

    abstract::For the last few years we have attempted to separate and isolate from biological fluids the uremic Middle Molecules (MM). The first step in the treatment of plasma is an ultrafiltration through AN69 membrane. The samples are fractionated by Sephadex G-15 chromatography into 9 peaks "a" to "i' under precise conditions ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors: Cueille G,Man NK,Sausse A,Farges JP,Funck-Brentano JL

    更新日期:1981-01-01 00:00:00

  • Selective Cerebro-Myocardial Perfusion in Complex Neonatal Aortic Arch Pathology: Midterm Results.

    abstract::Aortic arch repair in newborns and infants has traditionally been accomplished using a period of deep hypothermic circulatory arrest. To reduce neurologic and cardiac dysfunction related to circulatory arrest and myocardial ischemia during complex aortic arch surgery, an alternative and novel strategy for cerebro-myoc...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13128

    authors: Hoxha S,Abbasciano RG,Sandrini C,Rossetti L,Menon T,Barozzi L,Linardi D,Rungatscher A,Faggian G,Luciani GB

    更新日期:2018-04-01 00:00:00

  • Cell investigation into the biocompatibility of adult human dermal fibroblasts with PCL nanofibers/TiO2 nanotubes on the surface of Ti-30Ta alloy for biomedical applications.

    abstract::The polymer poly(ε-caprolactone) (PCL) has been used in the biomaterial field for its relatively inexpensive price and suitability for modification. Also, its chemical and biological properties are desirable for biomedical applications. The electrospinning process has been used for producing polymer fibers of PCL due ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13713

    authors: Capellato P,Silva G,Popat K,Simon-Walker R,Alves Claro AP,Zavaglia C

    更新日期:2020-08-01 00:00:00