Charged compounds of the glomerular filter and their role in normal and disordered permselectivity.

Abstract:

:Infusion into rats of the polycation hexadimethrine (HDM) leads to onset of massive proteinuria, which recovers when the infusion is stopped. Several lines of evidence indicate that the proteinuria results from binding of HDM to polyanions of the glomerular filter, with neutralization of shielding of their charges. To determine the mechanism of this proteinuria, we measured the glomerular sieving coefficients of anionic and neutral forms of albumin and IgG in control and proteinuric rats. Surprisingly, these studies revealed a marked defect in size dependence, but not in charge dependence, of glomerular permselectivity in hexadimethrine-treated animals, indicating that binding of HDM induces a structural change in the glomerular filter. In vitro studies of binding of tritiated HDM and cationized ferritin to glomerular basement membrane (GBM) indicate that the binding is not dependent on proteoglycans such as heparan sulfate, nor on sialoproteins such as podocalyxin, but is dependent on charged carboxyl groups of GBM.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Hunsicker LG,Bertolatus JA

doi

10.1111/j.1525-1594.1987.tb02712.x

subject

Has Abstract

pub_date

1987-12-01 00:00:00

pages

468-77

issue

6

eissn

0160-564X

issn

1525-1594

journal_volume

11

pub_type

杂志文章
  • Nonsymmetric leaflet motion of St. Jude Medical mitral valves simulated with a computer-controlled hydraulic mock circulator.

    abstract::Since the introduction of high-performance prosthetic heart valves, particularly bileaflet valves and monoleaflet valves with larger opening angles, we have observed in vivo complex leaflet motion which has not been experimentally confirmed yet. We developed a computer-controlled hydraulic mock circulator to study the...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb00373.x

    authors: Ohta Y,Okamoto K,Sonderegger M,Dohi T,Matsumoto H,Horiuchi T

    更新日期:1997-04-01 00:00:00

  • Bacterial and fungal infection in neonates undergoing venoarterial extracorporeal membrane oxygenation: an analysis of the registry data of the extracorporeal life support organization.

    abstract::A review and analysis of 5,001 neonatal venoarterial (VA) extracorporeal membrane oxygenation (ECMO) cases showed that bacterial and fungal infection occurred in 147 (2.9%) and 26 (0.6%) patients, respectively, with an overall incidence of 3.5%. Bivariate analysis was used to compare infected infants with controls, ba...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1996.tb04428.x

    authors: Douglass BH,Keenan AL,Purohit DM

    更新日期:1996-03-01 00:00:00

  • Pseudoendothelium formation in expanded polytetrafluoroethylene grafts implanted in the inferior vena cava of normal and defibrinogenated dogs.

    abstract::The outgrowth of endothelial cells in an expanded polytetrafluoroethylene graft implanted in the canine inferior vena cava was studied by scanning electron microscopy. The adjacent endothelial cells of the vena cava started to invade the anastomotic area three days after the implantation and reached approximately the ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1981.tb04020.x

    authors: Ishimaru S,Berglin E,Hansson HA,Teger-Nilsson AC,William-Olsson G

    更新日期:1981-11-01 00:00:00

  • Mathematical modeling of fluid dynamics in pulsatile cardiopulmonary bypass.

    abstract::The design criteria of an extracorporeal circuit suitable for pulsatile flow are quite different and more entangled than for steady flow. The time and costs of the design process could be reduced if mutual influences between the pulsatile pump and other extracorporeal devices were considered without experimental trial...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2003.47197.x

    authors: Pennati G,Fiore GB,Laganà K,Fumero R

    更新日期:2004-02-01 00:00:00

  • Intravenous prostacyclin mitigates inhaled nitric oxide rebound effect: A case control study.

    abstract::Although extracorporeal membrane oxygenation (ECMO) improves oxygenation, pulmonary vascular resistance may be increased due to endothelial function impairment. Inhaled nitric oxide (iNO) is increasingly used for treatment of pulmonary hypertension after surgical repair of congenital heart defects, with or without ECM...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06448.x

    authors: Hermon M,Golej J,Burda G,Marx M,Trittenwein G,Pollak A

    更新日期:1999-11-01 00:00:00

  • Evaluation of chitosan-alginate-hyaluronate complexes modified by an RGD-containing protein as tissue-engineering scaffolds for cartilage regeneration.

    abstract::In this study, a series of natural biodegradable materials in the form of chitosan (C)-alginate (A)-hyaluronate (H) complexes are evaluated as tissue-engineering scaffolds. The weight ratio of C/A is 1 : 1 or 1 : 2. Sodium hyaluronate is mixed in 2%. The complexes can be cast into films or fabricated as scaffolds. The...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2004.00046.x

    authors: Hsu SH,Whu SW,Hsieh SC,Tsai CL,Chen DC,Tan TS

    更新日期:2004-08-01 00:00:00

  • Investigation of the inherent left-right flow balancing of rotary total artificial hearts by means of a resistance box.

    abstract::With the incidence of end-stage heart failure steadily increasing, the need for a practical total artificial heart (TAH) has never been greater. Continuous flow TAHs (CFTAH) are being developed using rotary blood pumps (RBPs), leveraging their small size, mechanical simplicity, and excellent durability. To completely ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13631

    authors: Nestler F,Timms DL,Stevens M,Bradley AP,Wilson SJ,Kleinheyer M,Lovell N,Frazier OH,Cohn WE

    更新日期:2020-06-01 00:00:00

  • Hemolysis Related to Turbulent Eddy Size Distributions Using Comparisons of Experiments to Computations.

    abstract::Turbulent blood flow in medical devices contributes to blood trauma, yet the exact mechanism(s) have not been fully elucidated. Local turbulent stresses, viscous stresses, and the rate of dissipation of the turbulent kinetic energy have been proffered as hypotheses to describe and predict blood damage. In this work, s...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12572

    authors: Ozturk M,O'Rear EA,Papavassiliou DV

    更新日期:2015-12-01 00:00:00

  • A preliminary study of microcapsule suspension for hemolysis evaluation of artificial organs.

    abstract::A microcapsule suspension, a substitute for animal blood in hemolysis tests, has been developed for evaluation of the absolute hemolytic properties of circulatory artificial organs. The microcapsule suspension was made by dispersing microcapsule slurry into an ethylene glycol sodium chloride solution. The microcapsule...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06316.x

    authors: Maruyama O,Yamane T,Tsunemoto N,Nishida M,Tsutsui T,Jikuya T

    更新日期:1999-03-01 00:00:00

  • The human genome efforts and the cDNA project.

    abstract::Molecular biology has been moving swiftly toward clarifying the entire genome of organisms, including human. The human genome efforts that promote this transaction are characterized by the large-scale, high throughput production of data about the structure of the genome of the molecular level and its computer-assisted...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1111/j.1525-1594.1996.tb04553.x

    authors: Matsubara K

    更新日期:1996-08-01 00:00:00

  • Pulsatile flow and simple flow control method during weaning period in centrifugal pump: toward more expanded usage in open heart surgery.

    abstract::To expand the usage of the centrifugal pump (CP) in open heart surgery, we performed two studies. In the first, we evaluated pulsatile flow in the CP. In vitro pump performance of the Terumo Capiox pump (TCP) and the Sarns Delphin pump (SDP) and increase of free hemoglobin (mg/dl) after driving 6 h were investigated u...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1994.tb03393.x

    authors: Nishida H,Koyanagi H,Endo M,Suzuki S,Oshiyama H,Nojiri C,Fukasawa H,Akutsu T

    更新日期:1994-09-01 00:00:00

  • Selective inhibition of resistance to hemopoietic allografts but not rejection to a natural killer cell sensitive tumor in transgenic mice for granulocyte colony stimulating factor.

    abstract::Transplanted allogeneic marrow grafts often fail to engraft in a lethally irradiated host. Resistance to hemopoietic allograft is a complexed phenomenon involving multiple components. To study the involvement of a hemopoietic cytokine, which was known to play a role for stem cell function, we established lines of mice...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1996.tb04563.x

    authors: Kokai Y,Kimura H,Matsuura A,Fujimoto J

    更新日期:1996-08-01 00:00:00

  • Pump power loss and heat generation in a pivot bearing-supported Gyro centrifugal pump (C1E3).

    abstract::Pump power loss is defined as input power that is not used for the output work of the pump. Less pump power loss means a higher pump efficiency. A common opinion is that the pump power loss is closely related to heat generation of the pump, which may affect not only the endurance of pump materials, but also blood dama...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1996.tb04542.x

    authors: Takami Y,Nakazawa T,Makinouchi K,Glueck J,Ohara Y,Benkowski RJ,Nosé Y

    更新日期:1996-07-01 00:00:00

  • Flow balance between the left and right cardiac output of an eccentric roller type total artificial heart.

    abstract::We have made an eccentric roller type total artificial heart (ERTAH). The ERTAH is a positive-displacement device comparable to a DeBakey roller pump. Its left and right outputs are determined by the size of its blood chambers, and the ratio of its left and right output is almost constant. We focused on an interatrial...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06414.x

    authors: Wada H,Fukunaga S,Watari M,Sakai H,Sugawara Y,Ochikubo H,Imai K,Shibamura H,Orihashi K,Sueda T,Matsuura Y

    更新日期:1999-08-01 00:00:00

  • PEGylated carboxyhemoglobin bovine (SANGUINATE) ameliorates myocardial infarction in a rat model.

    abstract::Artificial oxygen (O2 ) carriers were reported to be protective in ischemia/reperfusion (I/R) in various organs including the heart. In the current study, 20 rats underwent ligation (MI) of the left anterior descending artery, were treated with 10 mL/kg of PEGylated carboxyhemoglobin bovine (SANGUINATE, S+, n = 10) or...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13384

    authors: Kawaguchi AT,Salybekov AA,Yamano M,Kitagishi H,Sekine K,Tamaki T

    更新日期:2018-12-01 00:00:00

  • A nonsurgical technique for blood access in extracorporeal affinity adsorption of antibodies in rats.

    abstract::Monoclonal antibodies for targeting cytotoxic conjugates to tumor cells are currently being evaluated together with extracorporeal affinity adsorption. The aim of the adsorption was to reduce undesired side effects in normal organs and to increase the tumor-to-normal tissue ratios. This technique is also applicable to...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2007.00380.x

    authors: Mårtensson L,Nilsson R,Sjögren HO,Strand SE,Tennvall J

    更新日期:2007-04-01 00:00:00

  • Role of the BioMedicus pump and distal aortic perfusion in thoracoabdominal aortic aneurysm repair.

    abstract::We reviewed the role of the BioMedicus pump in the reduction of neurologic complications following the repair of Type 1 and Type 2 thoracoabdominal aortic aneurysms. Since 1991, we have used several different methods for the repair of thoracoabdominal aortic aneurysms including simple cross-clamping, selective use of ...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:

    authors: Safi HJ

    更新日期:1996-06-01 00:00:00

  • Development of integrated electronics unit for drive and control of undulation pump-left ventricular assist device.

    abstract::In this study, we have developed an implantable electronics unit (IEU) for driving an undulation pump-left ventricular assist device (UP-LVAD). The IEU consists of a pump driver, three series-connected lithium ion batteries (1800 mAh), a charger, and a transcutaneous information transmission system. These electronic s...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2006.00233.x

    authors: Okamoto E,Makino T,Inoue Y,Tanaka S,Yasuda T,Nakamura M,Saito I,Abe Y,Chinzei T,Isoyama T,Mochiizuki S,Imachi K,Mitamura Y

    更新日期:2006-05-01 00:00:00

  • Recharging the battery of implantable biomedical devices by light.

    abstract::This article describes a new powering system for implantable medical devices that could significantly increase their lifetime. The idea is based on the substitution of the usual implantable device battery for an electric accumulator (rechargeable battery), which is fed by the electric power generated by a photovoltaic...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00803.x

    authors: Algora C,Peña R

    更新日期:2009-10-01 00:00:00

  • Clinical experience with BioMedicus centrifugal ventricular support in 172 patients.

    abstract::One hundred and seventy-two patients at The Methodist Hospital in Houston, Texas, were placed on BioMedicus centrifugal ventricular support. One hundred thirty-nine patients were male and 33 were female with a mean age of 59.7 years. Reasons for support were postcardiotomy cardiac failure (129 patients), cardiac allog...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1995.tb02419.x

    authors: Noon GP,Ball JW Jr,Papaconstantinou HT

    更新日期:1995-07-01 00:00:00

  • Magnetic suspension of the rotor of a ventricular assist device of mixed flow type.

    abstract::This work presents results of preliminary studies concerning application of magnetic bearing in a ventricular assist device (VAD) being developed by Dante Pazzanese Institute of Cardiology-IDPC (São Paulo, Brazil). The VAD-IDPC has a novel architecture that distinguishes from other known VADs. In this, the rotor has a...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00551.x

    authors: Horikawa O,de Andrade AJ,da Silva I,Bock EG

    更新日期:2008-04-01 00:00:00

  • Heparin-coated cardiopulmonary bypass circuits in coronary bypass surgery.

    abstract::Cardiopulmonary bypass (CPB) is a nonphysiologic environment for an organism. The damage of blood components may also lead to organ dysfunction, some-times recognized as postperfusion syndrome. One possible way to diminish the risk of these complications would be to reduce the thorombogenicity and to improve the bioco...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1525-1594.1996.tb04573.x

    authors: Horimoto H,Kondo K,Asada K,Sasaki S

    更新日期:1996-08-01 00:00:00

  • Renal osteodystrophy in dialysis patients: diagnosis and treatment.

    abstract::This article reviews the clinical, biological, radiological, and pathological procedures and their respective indications for the practical diagnosis of the following various histological patterns of renal osteodystrophy: osteitis fibrosa due to parathyroid hormone (PTH) hypersecretion: osteomalacia or rickets due to ...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1046/j.1525-1594.1998.06198.x

    authors: Fournier A,Oprisiu R,Hottelart C,Yverneau PH,Ghazali A,Atik A,Hedri H,Said S,Sechet A,Rasolombololona M,Abighanem O,Sarraj A,El Esper N,Moriniere P,Boudailliez B,Westeel PF,Achard JM,Pruna A

    更新日期:1998-07-01 00:00:00

  • Cell investigation into the biocompatibility of adult human dermal fibroblasts with PCL nanofibers/TiO2 nanotubes on the surface of Ti-30Ta alloy for biomedical applications.

    abstract::The polymer poly(ε-caprolactone) (PCL) has been used in the biomaterial field for its relatively inexpensive price and suitability for modification. Also, its chemical and biological properties are desirable for biomedical applications. The electrospinning process has been used for producing polymer fibers of PCL due ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13713

    authors: Capellato P,Silva G,Popat K,Simon-Walker R,Alves Claro AP,Zavaglia C

    更新日期:2020-08-01 00:00:00

  • Effects of hemodynamic conditions and valve sizing on leaflet bending stress in self-expanding transcatheter aortic valve: An in vitro study.

    abstract::Transcatheter aortic valve (TAV) replacement has become a viable alternative to surgery for high and intermediate risk patients with severe aortic stenosis. This technology may extend to the younger and lower risk patients. In this population, long-term durability of the TAV is key. Increased leaflet mechanical stress...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13654

    authors: Stanová V,Zenses AS,Thollon L,Kadem L,Barragan P,Rieu R,Pibarot P

    更新日期:2020-07-01 00:00:00

  • Permanent cardiac pacing after cardiac operations.

    abstract::From January 1980 through December 1990, implantation of a permanent pacemaker was performed in 34 patients following open heart surgery. The patients were divided into two groups according to the clinical indications for implantation of permanent pacemakers. Group 1 (9 patients) had surgical atrioventricular block, a...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1993.tb00591.x

    authors: Otaki M

    更新日期:1993-05-01 00:00:00

  • Hepatocyte culture between woven capillary networks: a microscopy study.

    abstract::A multi-compartment capillary membrane culture model with independently perfused three-dimensionally woven capillaries was developed for immobilization of hepatocytes in bioreactors. This enables spatial restructuring of cells and enhanced mass transfer performance with more efficient oxygenation and metabolite exchan...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1994.tb02181.x

    authors: Gerlach J,Schnoy N,Smith MD,Neuhaus P

    更新日期:1994-03-01 00:00:00

  • Impact of hemoglobin concentration and affinity for oxygen on tissue oxygenation: the case of hemoglobin-based oxygen carriers.

    abstract::In patients undergoing exchange-transfusion with hemoglobin (Hb)-based oxygen (O₂) carriers (HBOC), native Hb coexists with newly transfused Hb. The two Hb types share the same arterial and venous PO₂, but their affinities for O₂ vary. A simple spreadsheet model is described aiming at evaluating the contribution of ea...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2011.01296.x

    authors: Samaja M,Terraneo L

    更新日期:2012-02-01 00:00:00

  • Constraint stress, microstructural characteristics, and enhanced mechanical properties of a special fibroblast-embedded collagen construct.

    abstract::Cell-contracted collagen gels could provide rejection-free biomaterials for tissue engineering, but their application is limited by relatively low mechanical strength. We developed a special type I collagen construct (based on embedded fibroblasts) that was formed into a gel thread by using two anchors to constrain ge...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2006.00314.x

    authors: Feng Z,Ishibashi M,Nomura Y,Kitajima T,Nakamura T

    更新日期:2006-11-01 00:00:00

  • Survival of patients on chronic hemodialysis: single center experience.

    abstract::Patient survival from our hemodialysis (HD) center over the past 11 years was analyzed. Four hundred four patients, 212 female and 192 male, were treated by chronic intermittent HD. Patients were offered standard acetate-cellulosic membranes of 1.0-1.3 m2. During this period 181 patients died. One hundred three patien...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06291.x

    authors: Polenakovik M,Sikole A,Stojcev N,Spasovski G,Amitov V,Nikolov V,Masin G,Klinkmann H

    更新日期:1999-01-01 00:00:00