Computational flow optimization of rotary blood pump components.

Abstract:

:In an effort to improve and automate the fluid dynamic design of rotary blood pumps, a coupled computational fluid dynamics (CFD) shape optimization methodology has been developed and implemented. This program couples a finite element flow simulation with a gradient-based optimization routine to modify automatically the shape of an initial candidate blood path, according to a variety of desired fluid dynamic criteria, including shear stress, vorticity/circulation, and viscous dissipation. Preliminary results have led to both intuitive and nonintuitive transformations of the initial blood flow paths for both internal and external flows. This application of computer design optimization offers the ability to explore a much broader design space much more efficiently than would be possible with traditional parametric methods. It is believed that this computer tool can assist developers of rotary blood pumps in designing blood-wetted components that minimize thrombosis and hemolysis while simultaneously providing maximum flow performance.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Antaki JF,Ghattas O,Burgreen GW,He B

doi

10.1111/j.1525-1594.1995.tb02389.x

subject

Has Abstract

pub_date

1995-07-01 00:00:00

pages

608-15

issue

7

eissn

0160-564X

issn

1525-1594

journal_volume

19

pub_type

杂志文章
  • Bulk mass transport limitations during high-flux hemodialysis.

    abstract::Solute clearance during high-flux hemodialysis is determined by the combined effects of solute convection and diffusion in the membrane, blood, and dialysate. Previous studies have focused almost entirely on the membrane transport phenomena, largely ignoring the potential contribution from bulk mass transport across t...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1993.tb00403.x

    authors: Zydney AL

    更新日期:1993-11-01 00:00:00

  • Use of Bedside Ultrasonography and Saline Flush Technique for Evaluation of Central Venous Catheter Placement in Children.

    abstract::Our study investigated the reliability of appearance of rapid atrial swirl flow (RASF) by ultrasonography (US) in the right atrium (RA), which occurred as a result of rapid isotonic saline infusion (RISI) into the central venous catheter (CVC), in predicting catheter tip position. This prospective observational study ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13281

    authors: Yesilbas O,Sevketoglu E,Kihtir HS,Talip Petmezci M,Akcay N,Kocoglu Barlas U,Palabiyik F

    更新日期:2018-12-01 00:00:00

  • Reduction of driveline infections through doubled driveline tunneling of left ventricular assist devices.

    abstract::The durability of ventricular assist device (VAD) therapy improved steadily over the past years. However, driveline infections remain a challenge. To test whether an improved surgical implantation technique may lower the incidence of infections, we analyzed all patients receiving a VAD implantation in the years 2008 a...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12036

    authors: Fleissner F,Avsar M,Malehsa D,Strueber M,Haverich A,Schmitto JD

    更新日期:2013-01-01 00:00:00

  • The use of an approved biodegradable polymer scaffold as a solid support system for improvement of islet engraftment.

    abstract::The aim of this study was to investigate whether the use of a medically approved biodegradable scaffold as a solid support system would enhance graft survival following transplantation into the omental pouch in a preclinical large animal model. Six beagle dogs underwent total pancreatectomy followed by islet autotrans...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00688.x

    authors: Kin T,O'Neil JJ,Pawlick R,Korbutt GS,Shapiro AM,Lakey JR

    更新日期:2008-12-01 00:00:00

  • Intravenous prostacyclin mitigates inhaled nitric oxide rebound effect: A case control study.

    abstract::Although extracorporeal membrane oxygenation (ECMO) improves oxygenation, pulmonary vascular resistance may be increased due to endothelial function impairment. Inhaled nitric oxide (iNO) is increasingly used for treatment of pulmonary hypertension after surgical repair of congenital heart defects, with or without ECM...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06448.x

    authors: Hermon M,Golej J,Burda G,Marx M,Trittenwein G,Pollak A

    更新日期:1999-11-01 00:00:00

  • The OregonHeart Total Artificial Heart: Design and Performance on a Mock Circulatory Loop.

    abstract::Widespread use of heart transplantation is limited by the scarcity of donor organs. Total artificial heart (TAH) development has been pursued to address this shortage, especially to treat patients who require biventricular support. We have developed a novel TAH that utilizes a continuously spinning rotor that shuttles...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12959

    authors: Glynn J,Song H,Hull B,Withers S,Gelow J,Mudd J,Starr A,Wampler R

    更新日期:2017-10-01 00:00:00

  • Experimental setup to evaluate the performance of percutaneous pulmonary valved stent in different outflow tract morphologies.

    abstract::Percutaneous pulmonary valve implantation is a potential treatment for right ventricular outflow tract (RVOT) dysfunction. However, RVOT implantation site varies among subjects and the success of the procedure depends on RVOT morphology selection. The aim of this study was to use in vitro testing to establish percutan...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00673.x

    authors: Vismara R,Laganà K,Migliavacca F,Schievano S,Coats L,Taylor A,Bonhoeffer P

    更新日期:2009-01-01 00:00:00

  • A bedside micromethod for the determination of total carbon dioxide in biological fluids.

    abstract::The quality control of bicarbonate hemodialysis requires the determination of TCO2, either in blood or in dialysate. The use of the M + D TCO2 kit, a bedside micromethod, gave the authors an economical and reliable solution to this problem. ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1985.tb04404.x

    authors: Canaud B,Araujo A,Nguyen QV,Flavier JL,Mion C

    更新日期:1985-11-01 00:00:00

  • Investigation of the inherent left-right flow balancing of rotary total artificial hearts by means of a resistance box.

    abstract::With the incidence of end-stage heart failure steadily increasing, the need for a practical total artificial heart (TAH) has never been greater. Continuous flow TAHs (CFTAH) are being developed using rotary blood pumps (RBPs), leveraging their small size, mechanical simplicity, and excellent durability. To completely ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13631

    authors: Nestler F,Timms DL,Stevens M,Bradley AP,Wilson SJ,Kleinheyer M,Lovell N,Frazier OH,Cohn WE

    更新日期:2020-06-01 00:00:00

  • Improved liver function following treatment with an extracorporeal liver assist device.

    abstract::A 68-year-old woman with fulminant hepatic failure of unknown etiology was treated with a bioartificial liver assist device. Prior to treatment, she had a number of clinical and laboratory features that suggested a hopeless outcome. Treatment was associated with a dramatic change in her mental status, and her clinical...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1993.tb00381.x

    authors: Sussman NL,Kelly JH

    更新日期:1993-01-01 00:00:00

  • Pump power loss and heat generation in a pivot bearing-supported Gyro centrifugal pump (C1E3).

    abstract::Pump power loss is defined as input power that is not used for the output work of the pump. Less pump power loss means a higher pump efficiency. A common opinion is that the pump power loss is closely related to heat generation of the pump, which may affect not only the endurance of pump materials, but also blood dama...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1996.tb04542.x

    authors: Takami Y,Nakazawa T,Makinouchi K,Glueck J,Ohara Y,Benkowski RJ,Nosé Y

    更新日期:1996-07-01 00:00:00

  • Clinical long-term results of vascular prosthesis sealed with fragmented autologous adipose tissue.

    abstract::Tissue engineering can improve the former limitations of artificial organs. This article reports the long-term clinical results of grafts constructed with fragmented autologous adipose tissue. We did a retrospective analysis of a series of 53 patients with lower leg ischemia that received 69 fragmented adipose tissue ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2001.025003218.x

    authors: Karube N,Soma T,Noishiki Y,Yamazaki I,Kosuge T,Ichikawa Y,Takanashi Y

    更新日期:2001-03-01 00:00:00

  • Plasma middle molecules in asymptomatic and "sick" uremic patients.

    abstract::By using high speed gel filtration combined with ion exchange gradient elution chromatography, the concentrations of plasma (p) middle molecules (MM) were determined in 126 samples from 90 non-dialyzed azotemic patients and in 210 pre-dialysis samples from 53 regular hemodialysis and 24 intermittent peritoneal dialysi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors: Asaba H,Bergström J,Fürst P,Johnson C,Yahiel V

    更新日期:1981-01-01 00:00:00

  • The human genome efforts and the cDNA project.

    abstract::Molecular biology has been moving swiftly toward clarifying the entire genome of organisms, including human. The human genome efforts that promote this transaction are characterized by the large-scale, high throughput production of data about the structure of the genome of the molecular level and its computer-assisted...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1111/j.1525-1594.1996.tb04553.x

    authors: Matsubara K

    更新日期:1996-08-01 00:00:00

  • Heat exchangers for cardioplegia systems: in vitro study of four different concepts.

    abstract::The aim of this work is the evaluation of four different heat exchangers used for myocardium during cardioplegic system in cardiac surgeries. Four types of shell and tube heat exchangers made of different exchange elements were constructed, as follows: stainless steel tubes, aluminium tubes, polypropylene hollow fiber...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2003.07240.x

    authors: Drummond M,Novello WP,de Arruda AC,Braile DM

    更新日期:2003-05-01 00:00:00

  • Paracorporeal assistance system for restoring cardiac activity.

    abstract::Two series of experiments were conducted to assess the potential of artificial ventricular bypass in restoring cardiac activity. One series evaluated use of a paracorporeal left ventricle in 17 calves; the other evaluated biventricular bypass in 11 calves. Module pumps with a seamless blood chamber of polyurethane wer...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1987.tb02622.x

    authors: Tolpekin VE,Koblov LF,Kuvaev AE,Gasanov EK

    更新日期:1987-02-01 00:00:00

  • Surgical use of fluosol-DA in Jehovah's Witness patients.

    abstract::The effects of Fluosol-DA 20% on circulating blood cells, hemodynamic parameters, blood gases, and organs are described and compared with the results of phase I human studies and animal experiments. Bleeding of preoperative anemia and/or surgical bleeding, Fluosol-DA 20% was administered to 7 of 10 Jehovah's Witness p...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1984.tb04238.x

    authors: Ohyanagi H,Nakaya S,Okumura S,Saitoh Y

    更新日期:1984-02-01 00:00:00

  • A Meta-Analysis of Renal Function After Adult Cardiac Surgery With Pulsatile Perfusion.

    abstract::The aim of this meta-analysis was to determine whether pulsatile perfusion during cardiac surgery has a lesser effect on renal dysfunction than nonpulsatile perfusion after cardiac surgery in randomized controlled trials. MEDLINE, EMBASE, and the Cochrane Central Register of Controlled Trials were used to identify ava...

    journal_title:Artificial organs

    pub_type: 杂志文章,meta分析

    doi:10.1111/aor.12452

    authors: Nam MJ,Lim CH,Kim HJ,Kim YH,Choi H,Son HS,Lim HJ,Sun K

    更新日期:2015-09-01 00:00:00

  • Feasibility of extracorporeal on-line large-scale plasma adsorptions on protein A-sepharose columns in cancer patients.

    abstract::The feasibility of extracorporeal adsorption of 1.5-3 L plasma on protein A-Sepharose was investigated in six patients with advanced cancer. Anticoagulation with heparin was associated with respiratory distress syndrome in two patients, most likely caused by complement activation as indicated by a transient leukopenia...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1984.tb04247.x

    authors: Wallmark A,Grubb A,Freiburghaus C,Flodgren P,Husberg B,Lindholm T,Lindström C,Thysell H,Sjögren HO

    更新日期:1984-02-01 00:00:00

  • Uremic neuropathy: evidence of middle molecule toxicity.

    abstract::Ten dialysis patients were followed in a prospective study to determine the neurotoxicity of metabolites in the middle molecule (MM) molecular weight (mol wt) range of 500-200 daltons/molecule. In the absence of readily available direct serum measurements of MM concentrations, a theoretically calculated dialysis index...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1978.tb01002.x

    authors: Milutinovic J,Babb AL,Eschbach JW,Follette WC,Graefe U,Strand MJ,Scribner BH

    更新日期:1978-02-01 00:00:00

  • Prediction of mechanical hemolysis in medical devices via a Lagrangian strain-based multiscale model.

    abstract::This work introduces a new Lagrangian strain-based model to predict the shear-induced hemolysis in biomedical devices. Current computational models for device-induced hemolysis usually utilize empirical fitting of the released free hemoglobin (Hb) in plasma from damaged red blood cells (RBCs). These empirical correlat...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13663

    authors: Nikfar M,Razizadeh M,Zhang J,Paul R,Wu ZJ,Liu Y

    更新日期:2020-08-01 00:00:00

  • Extracorporeal membrane oxygenator compatible with centrifugal blood pumps.

    abstract::Coil-type silicone membrane oxygenators can only be used with roller blood pumps due to the resistance from the high blood flow. Therefore, during extracorporeal membrane oxygenation (ECMO) treatment, the combination of a roller pump and an oxygenator with a high blood flow resistance will induce severe hemolysis, whi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2002.07117.x

    authors: Motomura T,Maeda T,Kawahito S,Matsui T,Ichikawa S,Ishitoya H,Kawamura M,Nishimura I,Shinohara T,Oestmann D,Glueck J,Kawaguchi Y,Sato K,Nosé Y

    更新日期:2002-11-01 00:00:00

  • A novel method to evaluate thromboresistance of drip chambers with filter used in extracorporeal blood circuits for hemodialysis.

    abstract::We have developed a novel method to simultaneously evaluate thromboresistance of two different types of drip chambers with a filter used in extracorporeal blood circuits for hemodialysis using canine arteriovenous shunt models. Bilateral bypasses between the femoral artery and vein on both sides of the animal were for...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb00354.x

    authors: Yamazaki M,Kobayashi K,Mori Y,Satoh T,Kubota S

    更新日期:1997-02-01 00:00:00

  • Immunologic studies of hollow-fiber dialyzer extracts.

    abstract::Testing failed to detect free isocyanates in dialyzer rinses or significant levels of immunoglobulin E antibodies to isocyanate-protein conjugates in the serum of individuals reacting during hemodialysis with dialyzers containing Cuprophan membranes. Extended immunization of rabbits with Limulus lysate-reactive materi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1984.tb04298.x

    authors: Butcher BT,Reed MA,O'Neil CE,Leech S,Pearson FC

    更新日期:1984-08-01 00:00:00

  • Pulsatile flow and simple flow control method during weaning period in centrifugal pump: toward more expanded usage in open heart surgery.

    abstract::To expand the usage of the centrifugal pump (CP) in open heart surgery, we performed two studies. In the first, we evaluated pulsatile flow in the CP. In vitro pump performance of the Terumo Capiox pump (TCP) and the Sarns Delphin pump (SDP) and increase of free hemoglobin (mg/dl) after driving 6 h were investigated u...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1994.tb03393.x

    authors: Nishida H,Koyanagi H,Endo M,Suzuki S,Oshiyama H,Nojiri C,Fukasawa H,Akutsu T

    更新日期:1994-09-01 00:00:00

  • Experimental study on shear stress distributions in a centrifugal blood pump.

    abstract::Wall shear stress on the pump casing cover was measured using a surface-mounted hot-film sensor. In addition, the shear stress distribution in the pump was qualitatively investigated by means of oil-film visualization. The characteristics of shear stress in the pump are discussed, including the results on the oil-film...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2007.00421.x

    authors: Mizunuma H,Nakajima R

    更新日期:2007-07-01 00:00:00

  • Peritoneal dialysis solutions for the 21st century.

    abstract::Existing peritoneal dialysis (PD) solutions were formulated for the maintenance of fluid and electrolyte balance, correction of metabolic acidosis, and the removal of metabolic waste products. Solutions currently in development are designed to improve biocompatibility by neutralizing pH and reducing glucose degradatio...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1046/j.1525-1594.1998.06022.x

    authors: Martis L,Chen C,Moberly JB

    更新日期:1998-01-01 00:00:00

  • Permanent cardiac pacing after cardiac operations.

    abstract::From January 1980 through December 1990, implantation of a permanent pacemaker was performed in 34 patients following open heart surgery. The patients were divided into two groups according to the clinical indications for implantation of permanent pacemakers. Group 1 (9 patients) had surgical atrioventricular block, a...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1993.tb00591.x

    authors: Otaki M

    更新日期:1993-05-01 00:00:00

  • Comparison of four methods of cleaning hollow-fiber dialyzers for reuse.

    abstract::Four methods of cleaning hollow-fiber artificial kidneys (HFAKs) for reuse were compared in a prospective study. Each cleaning method was randomly assigned and HFAKs were reused until volume loss was greater than or equal to 15 ml, unless discarded for other reasons. HFAKs cleaned with 0.3 M sodium hydroxide averaged ...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1111/j.1525-1594.1986.tb02602.x

    authors: Dennis MB Jr,Vizzo JE,Cole JJ,Westendorf DL,Ahmad S

    更新日期:1986-12-01 00:00:00

  • Clinical evaluation of a new type of centrifugal pump.

    abstract::The major problems with existing centrifugal pumps are leakage, mechanical trauma, and thrombus formation. In consideration of these problems, a new compact centrifugal pump system was developed. The purpose of this study was to evaluate the new centrifugal pump system clinically. Ten patients underwent open heart sur...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1994.tb03403.x

    authors: Ninomiya J,Shoji T,Tanaka S,Ikeshita M,Ochi M,Yamauchi S,Yajima T,Yamauchi H,Sugimoto T,Aizawa T

    更新日期:1994-09-01 00:00:00