Abstract:
:Following implantation of a left ventricular assist device (LVAD), acceptable functional performance is now being achieved; however, peak VO2 and peak work load (watts) remain considerably limited. Maximum physical capacity is essentially dependent on generated cardiac output (CO) and arteriovenous oxygen difference (avDO2 ). We investigated the changes in CO and avDO2 during exercise in LVAD patients with an HVAD pump (HeartWare Inc., Framingham, MA, USA). Approximately 6 weeks after implantation, 20 patients (100% male, 60.8 ± 7.3 years old, BMI 25.7 ± 3.3) underwent a six-minute walk test (6MWT), a cardiopulmonary exercise test (CPET), and noninvasive hemodynamic measurement. The mean six-minute walking distance (6MWD) was 403 m (68% of predicted), and mean peak VO2 was 10.9 mL/kg/min (39% of predicted). Mean total CO improved from 3.8 L at rest to 7.0 L at maximum exercise. The mean avDO2 increased from 7.4 mL/dL (44% of oxygen content) at rest to 13.2 mL/dL (75% of oxygen content) at maximum exercise. There was a significant increase in both total CO (P < 0.01) and avDO2 (P < 0.05) between rest and sub-maximum exercise. As exercise levels increased, however, no further significant changes were achieved. Long-term studies, especially in combination with exercise programs, would be desirable in order to observe the development of these parameters.
journal_name
Artif Organsjournal_title
Artificial organsauthors
Schmidt T,Bjarnason-Wehrens B,Mommertz S,Hannig M,Schulte-Eistrup S,Willemsen D,Reiss Ndoi
10.1111/aor.13102subject
Has Abstractpub_date
2018-07-01 00:00:00pages
686-694issue
7eissn
0160-564Xissn
1525-1594journal_volume
42pub_type
杂志文章abstract::In patients undergoing exchange-transfusion with hemoglobin (Hb)-based oxygen (O₂) carriers (HBOC), native Hb coexists with newly transfused Hb. The two Hb types share the same arterial and venous PO₂, but their affinities for O₂ vary. A simple spreadsheet model is described aiming at evaluating the contribution of ea...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2011.01296.x
更新日期:2012-02-01 00:00:00
abstract::Although extracorporeal membrane oxygenation (ECMO) improves oxygenation, pulmonary vascular resistance may be increased due to endothelial function impairment. Inhaled nitric oxide (iNO) is increasingly used for treatment of pulmonary hypertension after surgical repair of congenital heart defects, with or without ECM...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.1999.06448.x
更新日期:1999-11-01 00:00:00
abstract::Liposome-encapsulated hemoglobin (LEH) was proven to be protective in cerebral ischemia/reperfusion injury. The present study evaluated LEH in a rat model of permanent middle cerebral artery (MCA) occlusion to clarify its effect during ischemia and reperfusion. Five minutes after thread occlusion of the MCA, rats were...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2008.00700.x
更新日期:2009-02-01 00:00:00
abstract::EXTEND (EXTra-uterine Environment for Neonatal Development) is a novel system for supporting extremely premature infants that replicates in utero conditions by maintaining a sterile fluid environment and providing gas exchange via a pumpless arteriovenous oxygenator circuit connected to the umbilical vessels. Target g...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.13524
更新日期:2019-12-01 00:00:00
abstract::The aim of this study was to evaluate the efficiency of hemoperfusion (HP) through coated resin adsorbent Synachrom E-5 in animal intoxications with organophosphate inhibitors of cholinesterases type of nerve agents. Five anesthetized dogs were intoxicated with 2 to 6 LD50 of VX substance and another 4 with 2 to 3 LD5...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1994.tb03317.x
更新日期:1994-10-01 00:00:00
abstract::Cardiopulmonary bypass (CPB) requirement in infants presents a unique challenge because of the large prime volume-to-blood volume ratio. Packed red blood cells (PRBCs) tend to deteriorate with long-term storage owing to their unphysiological composition and osmolality. Given that blood priming is inevitable in neonate...
journal_title:Artificial organs
pub_type: 杂志文章,随机对照试验
doi:10.1111/aor.13559
更新日期:2020-03-01 00:00:00
abstract::Doppler ultrasound is a noninvasive technique for monitoring moving objects such as flowing blood while ignoring stationary objects such as shunt tubing. A Doppler system was investigated to determine its sensitivity in detecting particulate release in blood during hemodialysis. Seven hemodialysis procedures with dogs...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1984.tb04275.x
更新日期:1984-05-01 00:00:00
abstract::Ventricular assist devices have been shown to be effective in advanced heart failure selected patients. They often have borderline end-organ function, what facilitates organ dysfunction. Liver failure is difficult to manage and leads to increased morbidity and mortality. We report a case of ductular cholestasis, an un...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2009.00760.x
更新日期:2010-02-01 00:00:00
abstract::To evaluate the potential clinical usefulness of a modified hemoglobin, pyridoxalated hemoglobin polyoxyethylene conjugate (PHP), the hindlimb vascular bed was perfused with PHP solution while monitoring tissue oxygen tension (PtO2) in anesthetized dogs. The hindlimb region was perfused through the external iliac arte...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1995.tb02371.x
更新日期:1995-06-01 00:00:00
abstract::In vitro cardiovascular device performance evaluation in a mock circulation loop (MCL) is a necessary step prior to in vivo testing. A MCL that accurately represents the physiology of the cardiovascular system accelerates the assessment of the device's ability to treat pathological conditions. To serve this purpose, a...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2010.01088.x
更新日期:2011-04-01 00:00:00
abstract::Centrifugal pumps are generally employed as nonpulsatile blood flow pumps; however, these pumps can produce pulsatile flow by periodically alternating the impeller rotation speed. This study investigates blood trauma due to the effect of pulse frequency and various ranges of pump speed. The hemolysis tests were conduc...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1997.tb00489.x
更新日期:1997-12-01 00:00:00
abstract::To provide percutaneous access, a new circulatory assist system was developed. We call this newly developed system the modified assist device (MAD). The system is composed of a sac-type blood pump and cannula. Inflow and outflow valves are mounted in the apex and at the side wall 10 cm from the apex of the cannula, re...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1996.tb00718.x
更新日期:1996-02-01 00:00:00
abstract::A pneumatically driven artificial heart with a tubular silicone rubber membrane and disc valves was used for functional heart replacement in the paracorporeal mode. A fluidic drive system allows adjustment of the heart rate, positive and negative pressures and systole/diastole ratio. Since August, 1977, the artificial...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1978.tb03465.x
更新日期:1978-08-01 00:00:00
abstract::Widespread use of heart transplantation is limited by the scarcity of donor organs. Total artificial heart (TAH) development has been pursued to address this shortage, especially to treat patients who require biventricular support. We have developed a novel TAH that utilizes a continuously spinning rotor that shuttles...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.12959
更新日期:2017-10-01 00:00:00
abstract::The aim of this study was to develop procedures for the diagnosis and nonsurgical management of decreased insulin flow in an implantable programmable pump for long-term intraperitoneal or intravenous insulin delivery featuring a sideport. Patency of the catheter lumen was tested by measuring the time needed for sidepo...
journal_title:Artificial organs
pub_type: 临床试验,杂志文章
doi:10.1111/j.1525-1594.1996.tb04586.x
更新日期:1996-09-01 00:00:00
abstract::A dynamic flow type testing to study calcification was self-designed to investigate calcification in bioprosthetic heart valves. The apparatus consists of a container into which leaflets from a porcine aortic valve are placed, a chamber that contains calcium solution, and a peristaltic pump that provides a continuous ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.2000.06482-2.x
更新日期:2000-02-01 00:00:00
abstract::The use of and demand for functional electrical stimulation (FES) systems and conventional orthoses in the spinal cord lesioned population was assessed. The assessment was conducted by a postal survey of the members of the spinal injury associations in the U.K. Out of all the respondents, only 2% had used an FES syste...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.1999.06361.x
更新日期:1999-05-01 00:00:00
abstract::Replacing the renal excretion of low molecular weight proteins (LMWP) by extracorporeal dialysis (dialysis) treatment poses technological challenges. Hemodialyzers with sieving coefficients for LMWP that match or even exceed those of the glomerular membrane barrier are commercially available; however, the associated l...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.13835
更新日期:2020-10-01 00:00:00
abstract::Only a small number of English hospitals provide postcardiotomy venoarterial extracorporeal membrane oxygenation (VA-ECMO) and there are doubts about its efficacy and safety. The aim of this service evaluation was to determine local survival rates and report on patient demographics. This was a retrospective service ev...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.13647
更新日期:2020-07-01 00:00:00
abstract::We assessed the relationship of certain clinical variables (including bradykinin [BK] release and dialysis membrane) to initial mean arterial pressure (MAP) reduction in 47 patients requiring continuous renal replacement therapy (CRRT) in an intensive care unit. The pretreatment MAP was 84 +/- 14 mm Hg for the group a...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.2001.06703.x
更新日期:2001-12-01 00:00:00
abstract::We aimed to determine the effect of elective left heart decompression at the time of initiation of central venoarterial extracorporeal membrane oxygenation (VA ECMO) on VA ECMO duration and clinical outcomes in children in a single tertiary ECMO referral center with a large pediatric population from a national referra...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/aor.12390
更新日期:2015-04-01 00:00:00
abstract::The vibrating flow pump (VFP) can generate high frequency oscillated blood flow. Because of the high frequency driving with short stroke volume, the pump system can be small. The disposable type VFP (D-VFP) was developed for use for extracorporeal circulation. The electromagnetic actuator was detached from the vibrati...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1997.tb03724.x
更新日期:1997-07-01 00:00:00
abstract::A surgical method for the implantation of a mechanical right ventricular assist device which avoids resternotomy/thoracotomy and related complications at the time of explantation is presented. In order to support the failing right heart, a Dacron vascular graft was sewn to the pulmonary artery. For venous drainage, a ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2012.01520.x
更新日期:2012-08-01 00:00:00
abstract::Hypertension is an important primary etiology of end-stage renal disease as well as a major factor responsible for progression of renal disease due to other causes. Multiple genetic and environmental factors are responsible for the variable prevalence of hypertension in various parts of the world. Although the frequen...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.2002.07067.x
更新日期:2002-09-01 00:00:00
abstract::For the last few years we have attempted to separate and isolate from biological fluids the uremic Middle Molecules (MM). The first step in the treatment of plasma is an ultrafiltration through AN69 membrane. The samples are fractionated by Sephadex G-15 chromatography into 9 peaks "a" to "i' under precise conditions ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:
更新日期:1981-01-01 00:00:00
abstract::This paper discussed issues of ethical assessment and moral concern associated with organ replacement and physical enhancement: research, allocation, organ donation, artificial organs, xenografts, biomaterials, and neuromaterials. While emphasizing the medical and moral benefits over associated risks, it calls for a b...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.1995.tb02362.x
更新日期:1995-05-01 00:00:00
abstract::In this study two aspects of hybrid functional electrical stimulation (FES) orthoses were investigated: joint motion constraints and FES control strategies. First, the effects of joint motion constraints on the gait of normal subjects were investigated using modern motion analysis systems, including electromyogram (EM...
journal_title:Artificial organs
pub_type: 临床试验,杂志文章
doi:10.1111/j.1525-1594.1997.tb04648.x
更新日期:1997-03-01 00:00:00
abstract::The objectives of this study were: (i) to evaluate the effects of perfusion modes (pulsatile vs. nonpulsatile) on vital organs recovery and (ii) to investigate the influences of two different perfusion modes on the homeostasis of thyroid hormones in pediatric patients undergoing cardiopulmonary bypass (CPB) procedures...
journal_title:Artificial organs
pub_type: 杂志文章,随机对照试验
doi:10.1111/j.1525-1594.2010.01159.x
更新日期:2010-11-01 00:00:00
abstract::Renal Solutions Allient Sorbent Hemodialysis System utilizes a two-chambered pneumatic pump (Pulsar Blood Pump, Renal Solutions, Inc., Warrendale, PA, USA) to avoid limitations associated with peristaltic pumping systems. Single-needle access is enabled by counter-pulsing the two pump chambers, thereby obviating compl...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1111/j.1525-1594.2009.00724.x
更新日期:2009-04-01 00:00:00
abstract::The rotary blood pump will be an implantable left ventricular assist device (LVAD) in the near future. However, the best control method and the interrelationship between the rotary blood pump and native heart functions are unclear. An estimation was made of the native heart cardiac output from the change of an LVAD's ...
journal_title:Artificial organs
pub_type: 杂志文章
doi:10.1046/j.1525-1594.1998.06127.x
更新日期:1998-05-01 00:00:00