Technical feasibility of umbilical cannulation in midgestation lambs supported by the EXTra-uterine Environment for Neonatal Development (EXTEND).

Abstract:

:EXTEND (EXTra-uterine Environment for Neonatal Development) is a novel system for supporting extremely premature infants that replicates in utero conditions by maintaining a sterile fluid environment and providing gas exchange via a pumpless arteriovenous oxygenator circuit connected to the umbilical vessels. Target gestational age (GA) for EXTEND support in human infants is 23-27 weeks, when immature lungs are most susceptible to injury in the setting of air ventilation. We previously demonstrated physiologic support of premature lambs cannulated at 105-117 days GA (lungs developmentally analogous to the 23-27 week GA human infant) for up to 28 days on EXTEND. In the present study, we sought to determine the technical feasibility of umbilical vessel cannulation in 85-96 days GA lambs delivered to EXTEND at weights equivalent to the 23-27 week GA human infant (500-850 g). Five preterm lambs were cannulated at 85-96 days GA (term 145 days) and supported on EXTEND for 4-7 days. All lambs underwent umbilical artery and umbilical vein cannulation. Circuit flows and pressures were monitored continuously, and blood gases were obtained at regular intervals for assessment of oxygen parameters. Systemic pH and lactate were measured at least once daily. Mean body weight at cannulation was 641 ± 71 g (range 480-850 g). All lambs were cannulated successfully (cannula size varied from 8 to 12 Fr), and mean survival on EXTEND was 140 ± 7 hours. Mean circuit flow was 213 ± 15 mL/kg*min, mean pH was 7.37 ± 0.01, and mean lactate was 1.6 ± 0.2 mmol/L. During the initial 120 hours after EXTEND cannulation, there were no significant differences between 85-96 days GA lambs and 105-117 days GA lambs in weight-adjusted circuit flows, oxygen delivery, pH, or lactate levels. This study demonstrates successful umbilical cord cannulation and adequate circuit flows and oxygen delivery in midgestation lambs size-matched to the 23-27 week GA human fetus, which represents an important step in the translation of EXTEND to clinical practice.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Hornick MA,Mejaddam AY,McGovern PE,Hwang G,Han J,Peranteau WH,Partridge EA,Davey MG,Flake AW

doi

10.1111/aor.13524

subject

Has Abstract

pub_date

2019-12-01 00:00:00

pages

1154-1161

issue

12

eissn

0160-564X

issn

1525-1594

journal_volume

43

pub_type

杂志文章
  • Comparison of a New Miniaturized Extracorporeal Membrane Oxygenation System With Integrated Rotary Blood Pump to a Standard System in a Porcine Model of Acute Lung Injury.

    abstract::Extracorporeal membrane oxygenation (ECMO) is used for severe acute respiratory distress syndrome. However, available ECMO systems are large and not well designed for fast delivery, emergency implantation, and interhospital transfer. Therefore, a new miniaturized oxygenator with integrated rotary blood pump (ILIAS) wa...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12611

    authors: Pilarczyk K,Heckmann J,Lyskawa K,Strauß A,Haake N,Wiese I,Jakob H,Kamler M,Pizanis N

    更新日期:2016-07-01 00:00:00

  • Flow pattern analysis of the Baylor total artificial heart.

    abstract::To obtain an optimal design of the left blood chamber of the total artificial heart (TAH), flow visualization studies were performed. Information on velocities in critical areas of the left chamber was gathered using sectional pulsed laser light. The flow patterns on the entire pumping duration were photographed frame...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1994.tb03345.x

    authors: Meier D,Wernicke JT,Orime Y,Takatani S,Tasai K,Damm G,Naito K,Mizuguchi K,Makinouchi K,Glueck J

    更新日期:1994-12-01 00:00:00

  • Bioengineered cartilage in a scaffold-free method by human cartilage-derived progenitor cells: a comparison with human adipose-derived mesenchymal stromal cells.

    abstract::The objective of our study was to investigate chondrogenesis potential of human adipose-derived mesenchymal stromal cells (MSCs), using as a positive control a human source of cartilage-derived progenitor cells (PCs). This source of PCs was recently described by our group and dwells on the surface of nasoseptal cartil...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12121

    authors: Baptista LS,Silva KR,Pedrosa CS,Amaral RJ,Belizário JV,Borojevic R,Granjeiro JM

    更新日期:2013-12-01 00:00:00

  • Differences in intravenous and subcutaneous application of recombinant human erythropoietin: a multicenter trial.

    abstract::The aims of this clinical study were to compare the maintenance doses for intravenous (i.v.) and subcutaneous (SC) administration of recombinant human erythropoietin (rhEPO) and to investigate whether there is any difference in the increase of the packed cellular volume (PCV) per week under i.v. and SC administration ...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章,多中心研究,随机对照试验

    doi:10.1111/j.1525-1594.1994.tb03378.x

    authors: Schaller R,Sperschneider H,Thieler H,Dutz W,Hans S,Voigt D,Marx M,Engelmann J,Schöter KH,Scigalla P

    更新日期:1994-08-01 00:00:00

  • Is serum albumin a marker of nutritional status in hemodialysis patients without evidence of inflammation?

    abstract::Hypoalbuminemia, a strong predictor of morbidity and mortality in hemodialysis patients, can be a consequence of a combination of malnutrition and inflammatory reactions. The purpose of this study was to analyze serum albumin as a marker of nutritional status in maintenance hemodialysis patients with no signs of infla...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2003.07273.x

    authors: Santos NS,Draibe SA,Kamimura MA,Canziani ME,Cendoroglo M,Júnior AG,Cuppari L

    更新日期:2003-08-01 00:00:00

  • Computational flow optimization of rotary blood pump components.

    abstract::In an effort to improve and automate the fluid dynamic design of rotary blood pumps, a coupled computational fluid dynamics (CFD) shape optimization methodology has been developed and implemented. This program couples a finite element flow simulation with a gradient-based optimization routine to modify automatically t...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1995.tb02389.x

    authors: Antaki JF,Ghattas O,Burgreen GW,He B

    更新日期:1995-07-01 00:00:00

  • Electrochemical and Electrophysiological Performance of Platinum Electrodes Within the Ninety-Nine-Electrode Stimulating Nerve Cuff.

    abstract::The trend in neural prostheses using selective nerve stimulation for electrical stimulation therapies is headed toward single-part systems having a large number of working electrodes (WEs), each of which selectively stimulate neural tissue or record neural response (NR). The present article reviews the electrochemical...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1111/aor.12625

    authors: Pečlin P,Mehle A,Karpe B,Rozman J

    更新日期:2015-10-01 00:00:00

  • In vivo characterization of a decellularized dermis-polymer complex for use in percutaneous devices.

    abstract::To develop a method for making percutaneous devices that have high biocompatibility and do not induce downgrowth of epidermal cells, we prepared a partial decellularized dermis (DD)/poly(methyl methacrylate) (PMMA) complex (PDPC) with a PMMA rod firmly stabilized inside. The porcine decellularized tissue was chosen be...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12330

    authors: Nam K,Matsushima R,Kimura T,Fujisato T,Kishida A

    更新日期:2014-12-01 00:00:00

  • End-point temperature of rewarming after hypothermic cardiopulmonary bypass in pediatric patients.

    abstract::In an attempt to find an adequate end-point rewarming temperature after hypothermic cardiopulmonary bypass (CPB), 50 pediatric patients who underwent cardiac surgery were randomly assigned for the end-point rectal rewarming temperature at either 35.5 (Group 1) or 37.0 degrees C (Group 2). The patients' rectal temperat...

    journal_title:Artificial organs

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/j.1525-1594.2005.00149.x

    authors: Kim WG,Yang JH

    更新日期:2005-11-01 00:00:00

  • Effects of inhaled nitric oxide on postoperative pulmonary circulation in patients with congenital heart disease.

    abstract::We studied 22 patients with residual pulmonary hypertension or symptoms of postoperative pulmonary hypertensive crisis. They received low-dose inhalation (10 ppm) of nitric oxide (NO), a selective pulmonary vasodilator, after total correction for congenital heart anomalies. Fifteen minutes of NO inhalation improved th...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1525-1594.1997.tb00692.x

    authors: Matsui J,Yahagi N,Kumon K,Hayashi H,Watanabe Y,Haruna M,Tanigami H,Yagihara T,Takamoto S,Kamiya T

    更新日期:1997-01-01 00:00:00

  • Computational fluid dynamics prediction of blood damage in a centrifugal pump.

    abstract::This study explores a quantitative evaluation of blood damage that occurs in a continuous flow left ventricular assist device due to fluid stress. Computational fluid dynamics (CFD) analysis is used to track the shear stress history of 388 particle streaklines. The accumulation of shear and exposure time is integrated...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2003.00026.x

    authors: Song X,Throckmorton AL,Wood HG,Antaki JF,Olsen DB

    更新日期:2003-10-01 00:00:00

  • Phosphorylcholine and poly(D,L-lactic acid) containing copolymers as substrates for cell adhesion.

    abstract::Fibroblast cell culture was performed to evaluate cell adhesion and cell morphology on novel hydrolyzable copolymers composed of poly(D,L-lactic acid) (PDLA) macromonomer, 2-methacryloyloxyethyl phosphorylcholine (MPC), and n-butyl methacrylate. The copolymers were used as cell culture materials for regulating the int...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2003.07015.x

    authors: Watanabe J,Ishihara K

    更新日期:2003-03-01 00:00:00

  • Use of Bedside Ultrasonography and Saline Flush Technique for Evaluation of Central Venous Catheter Placement in Children.

    abstract::Our study investigated the reliability of appearance of rapid atrial swirl flow (RASF) by ultrasonography (US) in the right atrium (RA), which occurred as a result of rapid isotonic saline infusion (RISI) into the central venous catheter (CVC), in predicting catheter tip position. This prospective observational study ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13281

    authors: Yesilbas O,Sevketoglu E,Kihtir HS,Talip Petmezci M,Akcay N,Kocoglu Barlas U,Palabiyik F

    更新日期:2018-12-01 00:00:00

  • HandS ECMO: Preliminary Experience With "Hub and Spoke" Model in Neonates With Meconium Aspiration Syndrome.

    abstract::We aim to evaluate clinical outcomes of emergent extracorporeal membrane oxygenation (ECMO) implantation in newborns with life-threatening meconium aspiration syndrome (MAS) in peripheral hospitals with Hub and Spoke (HandS) setting. We retrospectively reviewed all neonates presenting with MAS, with no other comorbidi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13270

    authors: Fichera D,Zanella F,Fabozzo A,Doglioni N,Trevisanuto D,Lolli E,Vida V,Ceccherini E,Ebraico A,Stellin G,Padalino M

    更新日期:2019-01-01 00:00:00

  • Analysis of left ventricular impedance in comparison with ultrasound images.

    abstract::Cardiac monitoring of ventricular assist devices (VADs) is important for detecting heart failure risks, such as critical arrhythmia and ventricular fibrillation, and for supplying data that are useful for hemodynamic control. Specifically, impedance cardiograms (ICGs) are especially beneficial because they have no eff...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2011.01381.x

    authors: Choi SW,Park SM

    更新日期:2012-05-01 00:00:00

  • Liposome encapsulated hemoglobin as a resuscitation fluid for hemorrhagic shock.

    abstract::The effectiveness of the blood substitute neo red cells (NRC) on hemorrhagic shock was evaluated in dogs. Shock was induced by bloodletting, and NRC was infused immediately until the dogs recovered from shock; the process was repeated 3 times (mild shock), or NRC was infused after shock was maintained for 30 min, and ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors: Usuba A,Osuka F,Kimura T,Sato R,Fujita Y,Yamashita M,Hoshino C

    更新日期:1998-02-01 00:00:00

  • Extracorporeal Life Support in Out-of-Hospital Refractory Cardiac Arrest.

    abstract::Out-of-Hospital refractory Cardiac Arrest (OHrCA) has a mortality rate between 90 and 95%. Since 2009, French medical academic societies have recommended the use of extracorporeal life support (ECLS) for OHrCA. According to these guidelines, patients were eligible for ECLS support if vital signs were still present dur...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12655

    authors: Rousse N,Robin E,Juthier F,Hysi I,Banfi C,Al Ibrahim M,Coadou H,Goldstein P,Wiel E,Vincentelli A

    更新日期:2016-09-01 00:00:00

  • Eccentric roller type total artificial heart creating interatrial shunt.

    abstract::Creating an interatrial shunt to achieve left-right flow balance and modification of the blood chambers to improve the basic performance of the device were performed in developing an eccentric roller type total artificial heart (ERTAH). Smaller blood chambers reduce friction loss and increase durability and energy eff...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06602.x

    authors: Wada H,Fukunaga S,Watari M,Imai K,Sakai H,Shibamura H,Sueda T,Matsuura Y

    更新日期:2000-08-01 00:00:00

  • Automatic Control of Veno-Venous Extracorporeal Lung Assist.

    abstract::Veno-venous extracorporeal lung assist (ECLA) can provide sufficient gas exchange even in most severe cases of acute respiratory distress syndrome. Commercially available systems are manually controlled, although an automatically controlled ECLA could allow individualized and continuous adaption to clinical requiremen...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12664

    authors: Kopp R,Bensberg R,Stollenwerk A,Arens J,Grottke O,Walter M,Rossaint R

    更新日期:2016-10-01 00:00:00

  • Research of flow dynamics and occlusion condition in roller pump systems used for ventricular assist.

    abstract::Roller pumps have been widely used in the ventricular assist field for many years, while the significant hemolysis caused by its mechanical stress is still a fundamental problem. Although the usual under-occlusion setting was considered as an effective method to reduce the hemolysis rate, its nonocclusive condition of...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13790

    authors: Zhou Y,Sun B,Chen M,Cui C

    更新日期:2020-07-31 00:00:00

  • Double-blind evaluation of plasmapheresis in schizophrenic patients: a pilot study.

    abstract::Interest in the effects and possible mechanisms of hemodialysis on schizophrenic patients has led to a double-blind evaluation of the effects of plasmapheresis on symptoms of schizophrenia. Also, plasmapheresis was felt to be an invaluable tool for investigating the autoimmune theory of schizophrenia. Patients (n = 10...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1111/j.1525-1594.1983.tb04203.x

    authors: Schulz SC,van Kammen DP,Waters R,Klein HG,Balow JE,Bunney WE Jr

    更新日期:1983-08-01 00:00:00

  • Effect of heparin, platelets, activated platelets, platelet fragments, and hematocrit on activated clotting time.

    abstract::Activated clotting time (ACT) is the most commonly used laboratory test to control the heparin effect during extracorporeal techniques. The study was undertaken in order to test in vitro the influence of heparin, platelet count, hematocrit, platelet fragmentation, and platelet activation on ACT. Blood was drawn from v...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06552.x

    authors: Girardi L,Sudi K,Muntean W

    更新日期:2000-07-01 00:00:00

  • Unsteady fluid dynamics of several mechanical prosthetic heart valves using a two component laser Doppler anemometer system.

    abstract::Five typical mechanical heart valves (Starr-Edwards, Björk-Shiley convexo-concave (c-c), Björk-Shiley monostrut, Bicer-Val, and St. Jude Medical) were tested in the mitral position under the pulsatile flow condition. The test program included measurements of velocity and turbulent stresses at 5 downstream locations. T...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb00451.x

    authors: Akutsu T,Modi VJ

    更新日期:1997-10-01 00:00:00

  • Usability and safety of ventricular assist devices: human factors and design aspects.

    abstract::The purpose of this study was the investigation of the usability and ergonomics of ventricular assist devices (VADs) in everyday usage. Patients with four different VAD types were observed. After implantation, instruction, and discharge from the hospital, the patients returned on a regular basis to the outpatient clin...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00844.x

    authors: Geidl L,Zrunek P,Deckert Z,Zimpfer D,Sandner S,Wieselthaler G,Schima H

    更新日期:2009-09-01 00:00:00

  • Development and clinical assay of the BCM ventricular assist device.

    abstract::The development of a ventricular assist device is depicted. The seven subprograms that make up the project are described briefly. Results obtained during the clinical assay showed that the new design of the input cannula working as a false auricle provides better efficiency, as well as a certain level of autoregulatio...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1994.tb03364.x

    authors: del Cañizo JF,Antoranz JC,Desco MM,Alvarez-Valdivielso JM,Fernandez-Caleya D,López M,Garcia-Barreno P,Duarte J

    更新日期:1994-07-01 00:00:00

  • Thromboembolic complications of the Symbion AVAD System.

    abstract::The Symbion Acute Ventricular Assist Device (AVAD) System is an experimental paracorporeal pulsatile ventricular assist device (VAD) for single or biventricular assist. Eleven patients were implanted but 2 died within 24 h and were excluded from the study. Nine patients, four with left ventricular assist devices (LVAD...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1525-1594.1989.tb01575.x

    authors: Icenogle TB,Smith RG,Cleavinger M,Vasu MA,Williams RJ,Sethi GK,Copeland JG

    更新日期:1989-12-01 00:00:00

  • The design modification of advanced ventricular assist device to enhance pulse augmentation and regurgitant flow shut-off.

    abstract::The new Advanced ventricular assist device (Advanced VAD) has many features such as improving pulsatility and preventing regurgitant flow during pump stoppage. The purpose of this study was to evaluate the effects of design modifications of the Advanced VAD on these features in vitro. Bench testing of four versions of...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13484

    authors: Miyamoto T,Byram N,Karimov JH,Adams J,Dessoffy R,Kuban BD,Gao S,Horvath DJ,Fukamachi K

    更新日期:2019-10-01 00:00:00

  • Totally Endoscopic Robotic-Assisted Cardiac Surgery in Children.

    abstract::Robotic surgery for intracardiac pathologies in children is relatively uncommon. This study presents our initial experience with robotic-assisted cardiac surgery in children. We also present the feasibility and safety of robotic surgery in children. From May 2013 to June 2018, 30 children underwent totally endoscopic ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13357

    authors: Onan B,Aydin U,Kadirogullari E,Onan IS,Sen O

    更新日期:2019-04-01 00:00:00

  • Pathways for water absorption and physiological role of the lateral interspaces in the kidney tubule.

    abstract::Possible routes for water and salt flow and the most likely theories that describe coupling between water and salt flow across leaky epithelia are presented. The osmotic theories seem the most likely ones. However, several of the theories have weaknesses that render them unsatisfactory, in particular because of the po...

    journal_title:Artificial organs

    pub_type: 杂志文章,评审

    doi:10.1111/j.1525-1594.1987.tb02713.x

    authors: Whittembury G,Carpi-Medina P,González E,Linares H

    更新日期:1987-12-01 00:00:00

  • Serum hyaluronic acid and interleukin-6 as possible markers of carpal tunnel syndrome in chronic hemodialysis patients.

    abstract::To elucidate the precise mechanism of carpal tunnel syndrome (CTS), serum hyaluronic acid (HA), interleukin-1 beta (IL-1 beta), interleukin-6 (IL-6), and tumor necrosis factor-alpha (TNF-alpha) were measured in 71 chronic hemodialysis patients with or without CTS and/or shoulder pain. Patients were divided into two gr...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1994.tb02227.x

    authors: Takasu S,Takatsu S,Kunitomo K,Kokumai Y

    更新日期:1994-06-01 00:00:00