Experimental investigation of pulsatility effect on the deformability and hemolysis of blood cells.

Abstract:

:In this study, we investigated the differences between pulsatile cardiopulmonary bypass (CPB) procedure and nonpulsatile CPB procedure in terms of their effects on hemolysis and deformability of red blood cells (RBCs) under various shear stress conditions. In order to research the effects on hemolysis and deformability, four parameters--free hemoglobin (fHb) concentration, normalized index of hemolysis (NIH), deformability index (DI) of RBCs, and elongation index of RBCs--have been deeply investigated. For these investigations, two randomly assigned adult mongrel dog groups-nonpulsatile group (NP, n = 6) and pulsatile group (P, n = 6)--were examined. According to our results, both types of perfusion did not show any statistical differences in terms of the concentrations of fHb as well as NIH. In addition, there were no significant differences in RBC deformability between perfusion types within an operation time of 3 h. Therefore, our studies suggest that pulsatile perfusion has no significant difference from nonpulsatile perfusion in terms of hemolysis and deformability of RBCs.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Kang YJ,Kim MG,Son KH,Lim CH,Son HS,Yoon SY,Kwon HS,Yang S

doi

10.1111/j.1525-1594.2009.00974.x

subject

Has Abstract

pub_date

2010-04-01 00:00:00

pages

E103-9

issue

4

eissn

0160-564X

issn

1525-1594

pii

AOR974

journal_volume

34

pub_type

杂志文章
  • Evaluation of chitosan-alginate-hyaluronate complexes modified by an RGD-containing protein as tissue-engineering scaffolds for cartilage regeneration.

    abstract::In this study, a series of natural biodegradable materials in the form of chitosan (C)-alginate (A)-hyaluronate (H) complexes are evaluated as tissue-engineering scaffolds. The weight ratio of C/A is 1 : 1 or 1 : 2. Sodium hyaluronate is mixed in 2%. The complexes can be cast into films or fabricated as scaffolds. The...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2004.00046.x

    authors: Hsu SH,Whu SW,Hsieh SC,Tsai CL,Chen DC,Tan TS

    更新日期:2004-08-01 00:00:00

  • The type of aortic cannula and membrane oxygenator affect the pulsatile waveform morphology produced by a neonate-infant cardiopulmonary bypass system in vivo.

    abstract::Although the debate still continues over the effectiveness of pulsatile versus nonpulsatile perfusion, it has been clearly proven that there are several significant physiological benefits of pulsatile perfusion during cardiopulmonary bypass (CPB) compared to nonpulsatile perfusion. However, the components of the extra...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.06017.x

    authors: Undar A,Lodge AJ,Daggett CW,Runge TM,Ungerleider RM,Calhoon JH

    更新日期:1998-08-01 00:00:00

  • Surface modification of silicone rubber membrane by plasma induced graft copolymerization as artificial cornea.

    abstract::In this study a highly biocompatible polymer membrane was prepared by surface modification. An artificial cornea was also developed for clinical applications. Silicone rubber (SR) membrane was grafted with hydrophilic monomers such as 2-hydroxyethyl methacrylate (HEMA) and acrylic acid by plasma induced grafted polyme...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1996.tb00661.x

    authors: Hsiue GH,Lee SD,Chang PC

    更新日期:1996-11-01 00:00:00

  • Physical testing of elastomers for cardiovascular applications.

    abstract::There are presently no short-term in vitro fatigue tests available that can predict long-term in vivo performance of elastomers in physiological environments. Thus, the introduction of new and better elastomers for cardiovascular applications is hampered in the development stage by lack of data about which materials s...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1983.tb04162.x

    authors: McMillin CR

    更新日期:1983-02-01 00:00:00

  • A pilot study of piracetam in cuprophan hemodialysis.

    abstract::Twelve patients, 8 male and 4 female, aged from 26 to 70 years were studied. They were on hemodialysis (HD) 4 h three times weekly with cuprophan hollow fiber dialyzers (Gambro 120M) and dialysate containing 35 mEq/L of acetate. The study compares two random HD sessions on each patient. Sixty minutes prior to one rand...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1111/j.1525-1594.1989.tb01551.x

    authors: Grekas D,Alivanis P,Karamouzis M,Pyrpasopoulos M,Tourkantonis A

    更新日期:1989-10-01 00:00:00

  • Experimental setup to evaluate the performance of percutaneous pulmonary valved stent in different outflow tract morphologies.

    abstract::Percutaneous pulmonary valve implantation is a potential treatment for right ventricular outflow tract (RVOT) dysfunction. However, RVOT implantation site varies among subjects and the success of the procedure depends on RVOT morphology selection. The aim of this study was to use in vitro testing to establish percutan...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00673.x

    authors: Vismara R,Laganà K,Migliavacca F,Schievano S,Coats L,Taylor A,Bonhoeffer P

    更新日期:2009-01-01 00:00:00

  • Dispersive aortic cannulas reduce aortic wall shear stress affecting atherosclerotic plaque embolization.

    abstract::Neurologic complications during on-pump cardiovascular surgery are often induced by mobilization of atherosclerotic plaques, which is directly related to enhanced wall shear stress. In the present study, we numerically evaluated the impact of dispersive aortic cannulas on aortic blood flow characteristics, with specia...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12359

    authors: Assmann A,Gül F,Benim AC,Joos F,Akhyari P,Lichtenberg A

    更新日期:2015-03-01 00:00:00

  • Development of an atraumatic small centrifugal pump for second-generation cardiopulmonary bypass.

    abstract::A small and light direct-drive centrifugal pump has been developed for cardiopulmonary bypass. In the development process, blood compatibility studies including a hemolysis study, an in vitro fluid dynamic performance study, and in vivo durability and feasibility studies were performed. The centrifugal pump with a 50 ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1992.tb00558.x

    authors: Jikuya T,Sasaki T,Aizawa T,Shiono M,Glueck JA,Smith CP,Feldman L,Sakuma I,Sekela ME,Noda T

    更新日期:1992-12-01 00:00:00

  • Oral treatment for jaundice using immobilized bilirubin oxidase.

    abstract::Jaundice is characterized by an excessive accumulation of bilirubin in the blood and tissues. A novel approach to reduce plasma levels of bilirubin by blocking its enterohepatic circulation was investigated. The treatment consisted of oral administration of immobilized bilirubin oxidase, which could oxidize bilirubin ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1992.tb00527.x

    authors: Soltys PJ,Mullon C,Langer R

    更新日期:1992-08-01 00:00:00

  • Nonsymmetric leaflet motion of St. Jude Medical mitral valves simulated with a computer-controlled hydraulic mock circulator.

    abstract::Since the introduction of high-performance prosthetic heart valves, particularly bileaflet valves and monoleaflet valves with larger opening angles, we have observed in vivo complex leaflet motion which has not been experimentally confirmed yet. We developed a computer-controlled hydraulic mock circulator to study the...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb00373.x

    authors: Ohta Y,Okamoto K,Sonderegger M,Dohi T,Matsumoto H,Horiuchi T

    更新日期:1997-04-01 00:00:00

  • Biodegradation and biocompatibility of polyorganophosphazene.

    abstract::We investigated biodegradation and biocompatibility of poly(organophosphazenes). We prepared poly(organophosphazenes) having different side chain groups. The blood compatibility of poly(organophosphazenes) containing fluorinated side groups, poly(bis[trifluoroethoxy]phosphazene) (PbFP) and poly([trifluoroethoxy][ethyl...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2002.07029.x

    authors: Kawakami H,Kanezaki S,Sudo M,Kanno M,Nagaoka S,Kubota S

    更新日期:2002-10-01 00:00:00

  • In Vitro Assessment of Electric Currents Increasing the Effectiveness of Vancomycin Against Staphylococcus epidermidis Biofilms.

    abstract::Biofilms are communities of bacteria that can cause infections which are resistant to the immune system and antimicrobial treatments, posing a significant threat for patients with implantable and indwelling medical devices. The purpose of our research was to determine if utilizing specific parameters for electric curr...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12678

    authors: Haddad PA,Mah TF,Mussivand T

    更新日期:2016-08-01 00:00:00

  • Selective Cerebro-Myocardial Perfusion in Complex Neonatal Aortic Arch Pathology: Midterm Results.

    abstract::Aortic arch repair in newborns and infants has traditionally been accomplished using a period of deep hypothermic circulatory arrest. To reduce neurologic and cardiac dysfunction related to circulatory arrest and myocardial ischemia during complex aortic arch surgery, an alternative and novel strategy for cerebro-myoc...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13128

    authors: Hoxha S,Abbasciano RG,Sandrini C,Rossetti L,Menon T,Barozzi L,Linardi D,Rungatscher A,Faggian G,Luciani GB

    更新日期:2018-04-01 00:00:00

  • Hemoperfusion and DNA synthesis in the rat liver. Part I: the effect of hemoperfusion on the rate of DNA synthesis.

    abstract::An investigation has been made into whether charcoal hemoperfusion stimulates a hyperplastic response in the liver of the normal rat. Animals underwent hemoperfusion over Norit RBX1 (Strathclyde, Glasgow, U.K.) charcoal granules using a technique which allowed perfusion in the unrestrained and conscious state. Control...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1982.tb04080.x

    authors: Ryan CJ,Courtney JM,Wood CB,Blumgart LH

    更新日期:1982-05-01 00:00:00

  • A hemoglobin-based multifunctional therapeutic: polynitroxylated pegylated hemoglobin.

    abstract::Polynitroxylated pegylated hemoglobin (PNPH) as a multifunctional therapeutic takes advantage of the ability of hemoglobin (Hb) to transport oxygen, the antioxidative stress activities from the redox coupling of nitroxide and heme iron, and the hypercolloid properties of pegylation. The published preclinical data demo...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2011.01307.x

    authors: Hsia CJ,Ma L

    更新日期:2012-02-01 00:00:00

  • Treatment of thyrotoxic crisis with plasmapheresis and single pass albumin dialysis: a case report.

    abstract::Thyrotoxic crisis (thyroid storm) is a life-threatening condition. Standard therapy is based on thiamazole, prednisolone, and nonselective beta-blockers. Extracorporeal plasmapheresis is an additional tool for removing circulating thyroxine in patients who do not respond quickly to conventional standard therapy. As th...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00924.x

    authors: Koball S,Hickstein H,Gloger M,Hinz M,Henschel J,Stange J,Mitzner S

    更新日期:2010-02-01 00:00:00

  • Kinetics of group IB and IIA phospholipase A2 during low-volume continuous hemodiafiltration in severe acute pancreatitis.

    abstract::Continuous hemodiafiltration (CHDF) has been performed for the treatment of severe acute pancreatitis. Phospholipase A2 (PLA2) is one of the important mediators which exacerbate acute pancreatitis, but whether PLA2 can be removed by CHDF is unclear. In this study, the kinetics of group IB and group IIA PLA2 was examin...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1525-1594.2007.00398.x

    authors: Suzuki M,Okahisa T,Sogabe M,Iwaki H,Okita Y,Ohnishi Y,Ito S

    更新日期:2007-05-01 00:00:00

  • Ethylene oxide sensitivity in hemodialysis patients.

    abstract::Sera from 138 patients who had experienced hypersensitivity-type reactions while on hemodialysis (reactors) were examined retrospectively by the radioallergosorbent test (RAST) for specific IgE antibody to ethylene oxide (ETO). Seventy-eight hemodialysis patients without a history of reaction were also evaluated as co...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1987.tb02638.x

    authors: Pearson F,Bruszer G,Lee W,Sagona M,Sargent H,Woods E,Dolovich J,Caruana R

    更新日期:1987-04-01 00:00:00

  • Development of a composite degradable/nondegradable tissue-engineered vascular graft.

    abstract::The present study aimed to determine the feasibility of constructing a reinforced autologous vascular graft by combining the advantages of fibrin gel as an autologous cell carrier material with the inherent mechanical strength of an integrated mesh structure. It was hypothesized that the mesh and dynamic culture condi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00601.x

    authors: Tschoeke B,Flanagan TC,Cornelissen A,Koch S,Roehl A,Sriharwoko M,Sachweh JS,Gries T,Schmitz-Rode T,Jockenhoevel S

    更新日期:2008-10-01 00:00:00

  • Partial artificial heart (ALVAD) use with subsequent cardiac and renal allografting in a patient with stone heart syndrome.

    abstract::The abdominal left ventricular assist device (ALVAD) is an order of magnitude more effective than conventional intra-aortic balloon pumping (IABP) in unloading and providing circulatory support to the failing left ventricle. This is a report of a unique case which demonstrates that in the absence of pulmonary vascular...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1978.tb01632.x

    authors: Norman JC,Dacso CC,Reul GJ,Massin EK,Klima T,Kahan BD,Keiser JT,Cooley DA

    更新日期:1978-11-01 00:00:00

  • End-point temperature of rewarming after hypothermic cardiopulmonary bypass in pediatric patients.

    abstract::In an attempt to find an adequate end-point rewarming temperature after hypothermic cardiopulmonary bypass (CPB), 50 pediatric patients who underwent cardiac surgery were randomly assigned for the end-point rectal rewarming temperature at either 35.5 (Group 1) or 37.0 degrees C (Group 2). The patients' rectal temperat...

    journal_title:Artificial organs

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/j.1525-1594.2005.00149.x

    authors: Kim WG,Yang JH

    更新日期:2005-11-01 00:00:00

  • The ethics of technology introduction.

    abstract::The rapid acceleration of technology development is outpacing our ability to assess it objectively and competently. Our challenge is to develop new assessment methods that take into account the fast moving nature of technology development while still protecting the patients' and the public interest. ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.06020.x

    authors: Abele JE

    更新日期:1998-01-01 00:00:00

  • A bridge from short-term to long-term left ventricular assist device--experimental verification of a physiological controller.

    abstract::A physiological controller is a key component to optimize the performance of left ventricular assist devices (LVADs) from short term to long term (10-20 years). The difficulties of its design lie in the inaccurate modeling of any particular human cardiovascular system because of limited knowledge, the large fluctuatio...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2004.07381.x

    authors: Wu Y,Allaire PE,Tao G,Adams M,Liu Y,Wood H,Olsen DB

    更新日期:2004-10-01 00:00:00

  • A compact mock circulation loop for the in vitro testing of cardiovascular devices.

    abstract::In vitro cardiovascular device performance evaluation in a mock circulation loop (MCL) is a necessary step prior to in vivo testing. A MCL that accurately represents the physiology of the cardiovascular system accelerates the assessment of the device's ability to treat pathological conditions. To serve this purpose, a...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2010.01088.x

    authors: Timms DL,Gregory SD,Greatrex NA,Pearcy MJ,Fraser JF,Steinseifer U

    更新日期:2011-04-01 00:00:00

  • The use of an approved biodegradable polymer scaffold as a solid support system for improvement of islet engraftment.

    abstract::The aim of this study was to investigate whether the use of a medically approved biodegradable scaffold as a solid support system would enhance graft survival following transplantation into the omental pouch in a preclinical large animal model. Six beagle dogs underwent total pancreatectomy followed by islet autotrans...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00688.x

    authors: Kin T,O'Neil JJ,Pawlick R,Korbutt GS,Shapiro AM,Lakey JR

    更新日期:2008-12-01 00:00:00

  • Extracorporeal life support during and after bilateral sequential lung transplantation in patients with pulmonary artery hypertension.

    abstract::The use of extracorporeal membrane oxygenator instead of standard cardiopulmonary bypass during lung transplantation is debatable. Moreover, recently, the concept of prolonged postoperative extracorporeal membrane oxygenator (ECMO) support has been introduced in many transplant centers to prevent primary graft dysfunc...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13628

    authors: Dell'Amore A,Campisi A,Congiu S,Mazzarra S,Pastore S,Dolci G,Baiocchi M,Frascaroli G

    更新日期:2020-06-01 00:00:00

  • Evaluation of the thrombogenicity of selected microporous oxygenator membranes.

    abstract::A comparative study of the thrombogenicity of several microporous membranes was performed using an ex vivo system simulating the conditions in an artificial lung. A study of platelet adhesion and adsorbed protein layer indicated that the membranes separated into three groups. Copolyurethane membranes adsorbed very few...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1985.tb04343.x

    authors: Knight PM,Lyman DJ

    更新日期:1985-02-01 00:00:00

  • Replacing cardiopulmonary bypass with extracorporeal membrane oxygenation in lung transplantation operations.

    abstract::Cardiopulmonary bypass (CPB) is required in some lung transplantation (LTx) operations. However, it increases risks of bleeding and early graft dysfunction. We report our experiences of replacing CPB with heparin-bound extracorporeal membrane oxygenation (ECMO) in LTx operations. If extracorporeal circulation was anti...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2001.025008607.x

    authors: Ko WJ,Chen YS,Lee YC

    更新日期:2001-08-01 00:00:00

  • The SlideReactor--a simple hollow fiber based bioreactor suitable for light microscopy.

    abstract::Most bioartificial liver support systems are based on hollow fiber capillaries within modified dialysis cartridges or more sophisticated bioreactor constructions. Due to their design microscopic follow-up of reorganization and growth of tissue between the hollow fibers is not possible. The SlideReactor is a simple hol...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2005.29049.x

    authors: Sauer IM,Schwartlander R,Schmid J,Efimova E,Vondran FW,Kehr D,Pless G,Spinelli A,Brandenburg B,Hildt E,Neuhaus P

    更新日期:2005-03-01 00:00:00

  • Microcirculation and artificial heart research.

    abstract::Small blood vessels may play a more important role in artificial heart (AH) recipients than ever suspected before. Observations of elevated total peripheral resistance, low hematocrit, reduced oncotic pressure, high circulating blood volume, and arterial pulsations with nonpulsatile devices require consideration of pe...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1988.tb01529.x

    authors: Lübbe AS

    更新日期:1988-02-01 00:00:00