Clinical Assessment of Histidine-Tryptophan-Ketoglutarate Solution and Modified St. Thomas' Solution in Pediatric Cardiac Surgery of Tetralogy of Fallot.

Abstract:

:The objective of this study is to compare the myocardium protective effect of Bretschneider's histidine-tryptophan-ketoglutarate (HTK) solution versus Modified St. Thomas' (STH) solution in pediatric cardiac surgery of Tetralogy of Fallot (TOF). Seventy-seven pediatric patients of TOF who received the total surgical repair were reviewed, from January 2014 to October 2015. A horizontal comparison between HTK solution and modified STH solution has been made since the HTK solutions were started to be used in our hospital. The patients were divided into the HTK group (n = 35) and the STH group (n = 33). The perioperative values of the groups were assessed in this study. The primary endpoints including spontaneous cardiac re-beating time, intensive care unit (ICU) stay, overall stay, mechanical ventilation postoperation, postoperation stay, overall stay, and perioperative echocardiographic results were analyzed in this study. We found that spontaneous cardiac re-beating time of the HTK group was significantly shorter than that of the STH group (0.26 min ± 0.56 vs. 1.33 ± 1.02, P < 0.001). There were no significant differences between the two groups in ICU stay (P = 0.29), postoperative mechanical ventilation time (P = 0.84), overall stay (0.73); and the mortalities of the two groups were similar (2.9 vs. 3.0%). Aimed at pediatric cardiac surgery of TOF, this study suggests that with similar aorta cross-clamping time, modified STH solution is as safe as HTK solution.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Wang ZH,An Y,Du MC,Qin TJ,Liu YB,Xu HZ,Yang LQ

doi

10.1111/aor.12771

subject

Has Abstract

pub_date

2017-05-01 00:00:00

pages

470-475

issue

5

eissn

0160-564X

issn

1525-1594

journal_volume

41

pub_type

杂志文章
  • The effects of homologous cross-circulation and in situ liver perfusion on fulminant hepatic failure rats.

    abstract::A galactosamine-induced fulminant hepatic failure (FHF) rat model was used to study the effects of homologous cross-circulation and in situ liver perfusion. Cross-circulation with homologous donors did not significantly improve the survival time or recovery rate of grade II hepatic coma rats. Homologous in situ liver ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1980.tb03929.x

    authors: Mohsini K,Lister C,Chang TM

    更新日期:1980-08-01 00:00:00

  • Surgical use of fluosol-DA in Jehovah's Witness patients.

    abstract::The effects of Fluosol-DA 20% on circulating blood cells, hemodynamic parameters, blood gases, and organs are described and compared with the results of phase I human studies and animal experiments. Bleeding of preoperative anemia and/or surgical bleeding, Fluosol-DA 20% was administered to 7 of 10 Jehovah's Witness p...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1984.tb04238.x

    authors: Ohyanagi H,Nakaya S,Okumura S,Saitoh Y

    更新日期:1984-02-01 00:00:00

  • Control systems for the electric heart.

    abstract::Methods to predict and control cardiac output (CO) accurately in total artificial heart (TAH) recipients have varied significantly in the last few decades. Early models exhibited minimal control mechanisms and involved fixed pumping parameters. Elaborate electromechanical systems that have recently evolved require int...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors: White RK,Olsen DB

    更新日期:1991-10-01 00:00:00

  • Dialyzer reuse: interaction between dialyzer membrane, disinfectant (formalin), and blood during dialyzer reprocessing.

    abstract::The growing practice of dialyzer reuse in recent years is mainly based on medical and economic considerations. However, adverse reactions such as immunohemolytic anemia due to anti-Nform antibody associated with dialyzer reuse have been reported. In this study, scanning electron microscopy and cytologic staining were ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1996.tb04418.x

    authors: Ng YY,Yang AH,Wong KC,Lan HY,Hung TL,Kerr PG,Huang TP

    更新日期:1996-01-01 00:00:00

  • Prevention of right heart failure after left ventricular assist device implantation by phosphodiesterase 5 inhibitor.

    abstract::Right ventricular (RV) function immediately after left ventricular assist device (LVAD) implantation is a crucial prognostic factor. RV failure is linked to increased mortality and worse outcome. A phosphodiesterase 5 inhibitor, sildenafil, was shown to decrease pulmonary vascular resistance and pulmonary artery press...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12277

    authors: Hamdan R,Mansour H,Nassar P,Saab M

    更新日期:2014-11-01 00:00:00

  • Modeling the transfer of low molecular weight plasma proteins during hemodialysis and online hemodiafiltration.

    abstract::Replacing the renal excretion of low molecular weight proteins (LMWP) by extracorporeal dialysis (dialysis) treatment poses technological challenges. Hemodialyzers with sieving coefficients for LMWP that match or even exceed those of the glomerular membrane barrier are commercially available; however, the associated l...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13835

    authors: Glancey G

    更新日期:2020-10-01 00:00:00

  • Effects of pyridoxalated hemoglobin polyoxyethylene conjugate and other hemoglobin-related substances on arterial blood pressure in anesthetized and conscious rats.

    abstract::The effects of pyridoxalated hemoglobin polyoxyethylene conjugate (PHP) and other hemoglobin-related substances on arterial blood pressure (ABP) and heart rate (HR) were examined. Infusion of PHP and other hemoglobin-related substances elevated ABP and increased HR. The degree of the increase in ABP and HR did not dif...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1995.tb02300.x

    authors: Kida Y,Maeda M,Iwata S,Iwashita Y,Goto K,Nishi K

    更新日期:1995-02-01 00:00:00

  • Evidence of absence of porcine endogenous retrovirus (PERV) infection in patients treated with a bioartificial liver support system.

    abstract::Porcine endogenous retrovirus (PERV) genomes are present in all pig cells. In this retrospective study, we assessed PERV infectivity in 28 patients treated with an extracorporeal bioartificial liver (HepatAssist system) that includes a membrane device containing porcine hepatocytes. All patients tested negative for PE...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06444.x

    authors: Pitkin Z,Mullon C

    更新日期:1999-09-01 00:00:00

  • Bacterial and fungal infection in neonates undergoing venoarterial extracorporeal membrane oxygenation: an analysis of the registry data of the extracorporeal life support organization.

    abstract::A review and analysis of 5,001 neonatal venoarterial (VA) extracorporeal membrane oxygenation (ECMO) cases showed that bacterial and fungal infection occurred in 147 (2.9%) and 26 (0.6%) patients, respectively, with an overall incidence of 3.5%. Bivariate analysis was used to compare infected infants with controls, ba...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1996.tb04428.x

    authors: Douglass BH,Keenan AL,Purohit DM

    更新日期:1996-03-01 00:00:00

  • Cadaver fitting study of the DexAide right ventricular assist device.

    abstract::The DexAide right ventricular assist device (RVAD) has been developed to provide an implantable RVAD option to surgeons. The aim of this study was to determine the optimal cannula design and optimal implantation location of the DexAide RVAD in preparation for its clinical use. Separately, a HeartMate XVE left ventricu...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2007.00438.x

    authors: Ootaki Y,Ootaki C,Kamohara K,Akiyama M,Cingoz F,Kopcak MW Jr,Dessoffy R,Liu J,Massiello A,Horvath D,Chen JF,Zhou Q,Benefit S,Golding LA,Fukamachi K

    更新日期:2007-08-01 00:00:00

  • Development of a flow estimation and control system of an implantable centrifugal blood pump for circulatory assist.

    abstract::A bypass flow rate estimation and control system (BECS) for an implantable centrifugal blood pump (ICBP) has been developed in our institute. The estimated flow rate (EF) of the ICBP was derived from the electric power consumption, the rotating speed of a motor, and the blood viscosity presumed by the hematocrit and b...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1998.06130.x

    authors: Wakisaka Y,Okuzono Y,Taenaka Y,Chikanari K,Endo S,Masuzawa T,Takano H

    更新日期:1998-06-01 00:00:00

  • Measurement of the closing behavior of the björk-shiley monoleaflet mechanical heart valve with an electrohydraulic total artificial heart.

    abstract::When cavitation occurs near a material surface of a mechanical heart valve (MHV), pits on the surface of the MHV and hemolysis are caused. Therefore, it is very important to investigate the possibility of the occurrence of cavitation in an MHV. To study the possibility of cavitation occurrence in a 25 mm Björk-Shiley ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2003.06981.x

    authors: Lee H,Tsukiya T,Homma A,Taenaka Y,Tatsumi E,Takano H

    更新日期:2003-08-01 00:00:00

  • Femoro-femoral versus atrio-aortic extracorporeal membrane oxygenation: selecting the ideal cannulation technique.

    abstract::Veno-arterial extracorporeal membrane oxygenation (ECMO) may be implanted using peripheral ECMO (pECMO) or central ECMO (cECMO) cannulation techniques. The aim of this study was to compare the outcome between these two cannulation techniques. A retrospective study was performed at Düsseldorf University Hospital from O...

    journal_title:Artificial organs

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/aor.12245

    authors: Saeed D,Stosik H,Islamovic M,Albert A,Kamiya H,Maxhera B,Lichtenberg A

    更新日期:2014-07-01 00:00:00

  • Effect of age on calcification of poly(hydroxyethyl methacrylate) in animals.

    abstract::The effect of age on the calcification of biomaterials was studied by the subcutaneous implantation of poly(hydroxyethyl methacrylate) hydrogel in rats. The hydrogel sheets were implanted in rats 6, 12, 24, and 52 weeks (1 year) of age. The retrieved implants were compared and the percentage weight increase by mineral...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1985.tb04388.x

    authors: Imai Y

    更新日期:1985-08-01 00:00:00

  • Reversal of experimental posthepatectomy liver failure in pigs: a new application of hepatocyte bioreactors.

    abstract::Postoperative liver failure remains a major cause of morbidity and mortality after extensive hepatectomies. This study aims to evaluate the effectiveness of a hepatocyte bioreactor in the treatment of experimental post-hepatectomy liver failure. Our experimental model included a combination of a side-to-side portacava...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2010.01016.x

    authors: Arkadopoulos N,Kostopanagiotou G,Nastos C,Papalois A,Papoutsidakis N,Kalimeris K,Defterevos G,Kanna T,Polyzois K,Kampouroglou G,Kypriotis D,Costopanagiotou C,Pafiti A,Tzanatos H,Smyrniotis V

    更新日期:2011-01-01 00:00:00

  • Outcome analysis for prediction of intraaortic balloon pump support failure and long-term survival in high-risk patients undergoing mitral valve surgery.

    abstract::The outcome predictors of intra-aortic balloon pump (IABP) in patients who undergo mitral valve surgery remain unknown. This study aimed to retrospectively review valvular surgery in patients who received an IABP to identify the predictors of failure of IABP support and anticipate the necessary therapy. This retrospec...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13669

    authors: Liang M,Wang C,Feng K,Chen G,Wang K,Wu Z

    更新日期:2020-08-01 00:00:00

  • Hemodynamic Evaluation of a Biological and Mechanical Aortic Valve Prosthesis Using Patient-Specific MRI-Based CFD.

    abstract::Modeling different treatment options before a procedure is performed is a promising approach for surgical decision making and patient care in heart valve disease. This study investigated the hemodynamic impact of different prostheses through patient-specific MRI-based CFD simulations. Ten time-resolved MRI data sets w...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12955

    authors: Hellmeier F,Nordmeyer S,Yevtushenko P,Bruening J,Berger F,Kuehne T,Goubergrits L,Kelm M

    更新日期:2018-01-01 00:00:00

  • Detection of suction and regurgitation of the implantable centrifugal pump based on the motor current waveform analysis and its application to optimization of pump flow.

    abstract::In this study, a detection algorithm for suction and regurgitation of the centrifugal pump during left heart bypass without relying on external flow or pressure sensors was developed and evaluated in acute studies using adult goats. The detection scheme relies on power spectral density (PSD) analysis of the motor curr...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.1999.06397.x

    authors: Yuhki A,Hatoh E,Nogawa M,Miura M,Shimazaki Y,Takatani S

    更新日期:1999-06-01 00:00:00

  • Relation between echinocytosis and erythrocyte calcium content in hemodialyzed uremic patients.

    abstract::A rise in intracellular calcium concentration in erythrocytes has multiple effects on these cells. The purpose of this study was to determine the changes of calcium content in red blood cells (RBCs) and of echinocyte percentages in uremic patients during hemodialysis sessions. In 30 uremic patients under hemodialysis,...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2001.025006486.x

    authors: Agroyannis B,Kopelias I,Fourtounas C,Paraskevopoulos A,Tzanatos H,Dalamangas A,Mallas E

    更新日期:2001-06-01 00:00:00

  • Influence of growth hormone on maintenance of capillary-like structures in an in vitro model of stromal vascular tissue--results from morphometric analysis.

    abstract::The in vitro development of a vascular stroma might be a solution for the engineering of vascularized tissues, however, in vitro stability of capillary-like structures is limited. In order to test the influence on maintenance of capillary-like structures, human growth hormone (hGH) was added in concentrations of 0.5, ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2005.29057.x

    authors: Frerich B,Kurtz-Hoffmann J,Lindemann N

    更新日期:2005-04-01 00:00:00

  • Plasmapheresis-related hypotension.

    abstract::Hypotension is an uncommon complication of procedures involving extracorporeal circulation, including plasmapheresis. From November 1993 to March 1999, we treated 139 patients who underwent a total of 1,137 sessions of double filtration plasmapheresis (DFP). Hypotension was defined as a systolic blood pressure (BP) < ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06521.x

    authors: Yeh JH,Chiu HC

    更新日期:2000-09-01 00:00:00

  • Oral treatment for jaundice using immobilized bilirubin oxidase.

    abstract::Jaundice is characterized by an excessive accumulation of bilirubin in the blood and tissues. A novel approach to reduce plasma levels of bilirubin by blocking its enterohepatic circulation was investigated. The treatment consisted of oral administration of immobilized bilirubin oxidase, which could oxidize bilirubin ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1992.tb00527.x

    authors: Soltys PJ,Mullon C,Langer R

    更新日期:1992-08-01 00:00:00

  • Reduction of early postoperative morbidity in cardiac surgery patients treated with continuous veno-venous hemofiltration during cardiopulmonary bypass.

    abstract::Cardiac surgery with cardiopulmonary bypass is associated with a systemic inflammatory response syndrome. The major clinical features of this include a reduction of pulmonary compliance and increased extracellular fluids, with increased pulmonary shunt fraction similar to acute respiratory distress syndrome, thus resu...

    journal_title:Artificial organs

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/j.1525-1594.2009.00777.x

    authors: Luciani R,Goracci M,Simon C,Principe F,Fazzari L,Punzo G,Menè P

    更新日期:2009-08-01 00:00:00

  • Are standard human coagulation tests suitable in pigs and calves during extracorporeal circulation?

    abstract::The thrombogenicity of membrane oxygenators as well as clotting parameters profiles, using standard human clotting tests, was analyzed in calves and pigs during 6 h perfusion. Three calves and 3 pigs were connected to extracorporeal circulation with standard heparinization. Blood samples were taken for coagulation var...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2001.025007579.x

    authors: Mueller XM,Tevaearai HT,Jegger D,Tucker O,von Segesser LK

    更新日期:2001-07-01 00:00:00

  • Intravascular micropump for augmented liver perfusion: first in vivo experience.

    abstract::The aim of this study was to assess the in vivo performance of a new microaxial rotary blood pump developed for long-term intraportal implantation. The pump, measuring 7 mm in diameter, has a single stage impeller and is powered by a microelectric motor. The pump was implanted into the portal vein in 13 large white pi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2001.06772.x

    authors: Havlík R,Kerkhoffs W,Jiao LR,Schumacher O,Reul H,Habib N

    更新日期:2001-05-01 00:00:00

  • The bradykinin response and early hypotension at the introduction of continuous renal replacement therapy in the intensive care unit.

    abstract::We assessed the relationship of certain clinical variables (including bradykinin [BK] release and dialysis membrane) to initial mean arterial pressure (MAP) reduction in 47 patients requiring continuous renal replacement therapy (CRRT) in an intensive care unit. The pretreatment MAP was 84 +/- 14 mm Hg for the group a...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2001.06703.x

    authors: Stoves J,Goode NP,Visvanathan R,Jones CH,Shires M,Will EJ,Davison AM

    更新日期:2001-12-01 00:00:00

  • Multimodal flow visualization and optimization of pneumatic blood pump for sorbent hemodialysis system.

    abstract::Renal Solutions Allient Sorbent Hemodialysis System utilizes a two-chambered pneumatic pump (Pulsar Blood Pump, Renal Solutions, Inc., Warrendale, PA, USA) to avoid limitations associated with peristaltic pumping systems. Single-needle access is enabled by counter-pulsing the two pump chambers, thereby obviating compl...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00724.x

    authors: Shu F,Parks R,Maholtz J,Ash S,Antaki JF

    更新日期:2009-04-01 00:00:00

  • How to comply with the Food and Drug Administration's "Investigational Device Exemption (IDE)" regulations including an application form (revised January 1982).

    abstract::This is a revision of the IDE Application Form, "How to Comply with the Food and Drug Administration's New 'Investigational Device Exemption (IDE)' Regulations, Including an Application Form" originally published in Artificial Organs, Volume 4, Number 4, November 1980. This publication updates the IDE application form...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:

    authors:

    更新日期:1982-02-01 00:00:00

  • Effects of customized bicarbonate buffered solutions for continuous renal replacement therapies on polymorphonuclear leukocytes function and viability.

    abstract::It has previously been shown that the mixture of bicarbonate and calcium in the solutions used for continuous renal replacement therapy led to crystallization and significant changes in calcium concentration and pH. The aim of this study was to investigate the impact of bicarbonate/calcium and lactate/calcium solution...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2004.07284.x

    authors: Maccariello E,Dalboni MA,Draibe SA,Rocha E,Pavão dos Santos OF,Santos B,Cendoroglo M

    更新日期:2004-06-01 00:00:00

  • Development of high-efficiency molecular adsorbent recirculating system: preliminary report.

    abstract::Molecular Adsorbent Recirculating System (MARS) is a liver support system widely employed in the treatment of liver failure. The method is normally well tolerated. To develop a liver support system combining high efficiency and tolerability, we modified the MARS albumin circuit with the insertion of double adsorption ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12250

    authors: Marangoni R,Bellati G,Castelli A,Romagnoli E